“Visualization of As(III) and As(V) distributions in degraded paint micro-samples from Baroque- and Rococo-era paintings”. Vermeulen M, Nuyts G, Sanyova J, Vila A, Buti D, Suuronen J-P, Janssens K, Journal of analytical atomic spectrometry 31, 1913 (2016). http://doi.org/10.1039/C6JA00134C
Abstract: Orpiment and realgar, both arsenic sulfide pigments respectively used for their vivid yellow and red-orange hues, are two of many artists' pigments that appear not to be stable upon light exposure, quickly degrading to arsenic trioxide and arsenate. This often results in whitening or transparency in the painted surfaces. While conventional techniques such as microscopic Raman (mu-RS) and microscopic Fourier transform infrared (mu-FTIR) spectroscopies can allow a quick and relatively easy identification of the orpiment, realgar, artificial arsenic sulfide glass and, to some extent, arsenic oxide, the identification and visualization of distributions of the degradation products – and especially arsenate compounds – in the paint micro-samples is generally more challenging. This challenge is due to the rather unfavorable limit of detection and low spectral resolution of such conventional spectroscopic techniques. This restricts the conclusions that can be drawn regarding the conservation state of valuable works of art. In this paper, we present how synchrotron radiation (SR) based techniques can overcome this challenge while working on painting cross-sections taken from a 17th-century painting by the Flemish artist Daniel Seghers (oil on canvas, Statens Museum for Kunst, Denmark) and an 18th-century French Chinoiserie (private collection, France). SR micro-X-ray fluorescence (m-XRF) mapping analysis performed on a visually degraded orpiment-containing paint stratigraphy reveals that arsenic is distributed throughout the entire cross-section, while X-ray absorption near edge structure (mu-XANES) demonstrated that the arsenic is present in both arsenite (As-III) and arsenate (As-V) forms. The latter compound(s), despite being barely identifiable by means of FTIR, were not only located at the surface of large and partially altered grains of arsenic sulfide but also spread throughout the entire paint stratigraphy. Their presence and distribution are attributed either to the complete degradation of smaller arsenic sulfide grains or to migration of the arsenates within the paint layer away from their original location of formation. The combination of mu-XRF and mu-XANES was very useful for the characterization of the advanced degradation state of the arsenic-containing pigments in paint systems; this type of information could not be obtained by means of conventional spectroscopic methods of microanalysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 20
DOI: 10.1039/C6JA00134C
|
|
|
“Air particulate emissions in developing countries : a case study in South Africa”. Worobiec A, Potgieter-Vermaak SS, Berghmans P, Winkler H, Burger R, Van Grieken R, Analytical letters 44, 1907 (2011). http://doi.org/10.1080/00032719.2010.539734
Abstract: Atmospheric aerosols were collected during the winter in Bethlehem, South Africa. The particulate mass concentrations, ambient carbon mass concentrations, and chemical composition of various particulate fractions showed that the area is highly polluted. The fine particle mass concentrations peaked at 1000 µg/m3 for PM2.5. Ambient carbon mass concentrations ranged from 20 to 40 µg/m3. Single particle analysis confirmed that the fine particle fraction was dominated by organic particles. The topographical conditions, causing a low inversion, together with the high amounts of emissions from biomass burning, result in unacceptable levels of air pollution and pose a considerable health threat to the population.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1080/00032719.2010.539734
|
|
|
“Enhancement of X-ray fluorescence intensity from an ultra-thin sandwiched layer at grazing-emission angles”. Tsuji K, Takenaka H, Wagatsuma K, de Bokx PK, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1881 (1999). http://doi.org/10.1016/S0584-8547(99)00143-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00143-3
|
|
|
“Absorption correction via scattered radiation in energy-dispersive X-ray fluorescence analysis for samples of variable composition and thickness”. Van Dyck PM, Van Grieken RE, Analytical chemistry 52, 1859 (1980). http://doi.org/10.1021/AC50062A020
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50062A020
|
|
|
“Effects of a constructional intervention on airborne and deposited particulate matter in the Portuguese National Tile Museum, Lisbon”. Anaf W, Horemans B, Madeira TI, Carvalho ML, De Wael K, Van Grieken R, Environmental Science and Pollution Research 20, 1849 (2013). http://doi.org/10.1007/S11356-012-1086-7
Abstract: In the 1970s, a large ambulatory of the National Tile Museum, Lisbon, was closed with glass panes on both ground and first floor. Although this design was meant to protect the museum collection from ambient air pollutants, small openings between the glass panes remain, creating a semi-enclosed corridor. The effects of the glass panes on the indoor air quality were evaluated in a comparative study by monitoring the airborne particle concentration and the extent of particle deposition at the enclosed corridor as well as inside the museum building. Comparison of the indoor/outdoor ratio of airborne particle concentration demonstrated a high natural ventilation rate in the enclosed corridor as well as inside the museum building. PM10 deposition velocities on vertical surfaces were estimated in the order of 3 × 10−4 m s−1 for both indoor locations. Also, the deposition rates of dark-coloured and black particles in specific were very similar at both indoor locations, causing visual degradation. The effectiveness of the glass panes in protecting the museum collection is discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.741
Times cited: 15
DOI: 10.1007/S11356-012-1086-7
|
|
|
“Intercalation of proflavine in ssDNA aptamers : effect on binding of the specific target chloramphenicol”. Pilehvar S, Jambrec D, Gebala M, Schuhmann W, De Wael K, Electroanalysis 27, 1836 (2015). http://doi.org/10.1002/ELAN.201500192
Abstract: The structural modification of ssDNA-based aptamers upon specific binding of its target molecule leads to changes of the charge-transfer resistance (Rct) of a negatively-charged free-diffusing redox probe. The aptamer adopts a structure due to self-hybridization which is stabilized using profalvine as intercalator. The pre-organized aptamer structure is used to detect chloramphenicol (CAP) requiring a substantial change of the aptamer structure indicated by a CAP concentration dependent increase in the Rct values. Pre-incubation of the aptamer-modified electrode with an intercalator allows for the modulation of the aptamer/target interaction and hence for a modulation of the CAP-dependent variation of the Rct values.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.851
Times cited: 5
DOI: 10.1002/ELAN.201500192
|
|
|
“The electrochemistry of a gelatin modified gold electrode”. De Wael K, Verstraete A, van Vlierberghe S, Dejonghe W, Dubruel P, Adriaens A, International journal of electrochemical science 6, 1810 (2011)
Abstract: This paper discusses the electrochemical behaviour of gelatin coated gold electrodes in physiological pH conditions in a potential window −1.5 till 1.0 V vs SCE by performing cyclic voltammetry. A comparison is made between gelatin A and gelatin B, which have respectively a positive and a negative net charge at physiological pH. The deposition of gelatin onto the gold surface is confirmed by means of attenuated total reflection-infrared (ATR-IR) spectroscopic analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.469
|
|
|
“Investigation of volatile organic compounds in museum storage areas”. Alvarez-Martin A, Wilcop M, Anderson R, Wendt D, Barden R, Kavich GM, Air Quality Atmosphere And Health 14, 1797 (2021). http://doi.org/10.1007/S11869-021-01054-2
Abstract: This study investigates the complex mixture of volatile organic compounds (VOCs) released by and accumulated within a collection of historic medicinal, pharmaceutical, and cosmetic artifacts housed at the National Museum of American History (Smithsonian Institution). In recent years, staff have become concerned, both for the safety of the objects and for personnel working in the collection, about strong unremediated odors accumulating within several storage cabinets. Museum staff also wondered if non-odorous off-gassing might need remediation. Solid-phase microextraction combined with gas chromatography–mass spectrometry analysis (SPME–GC–MS) was used to identify VOCs present in the storage room housing the collection. Over 160 compounds were detected and identified overall. Among these, 49 appeared to be directly related to ingredients used in the manufacture of many collection items. The results of the study suggest that SPME–GC–MS can be a strong tool for the rapid screening of multicomponent museum collections exhibiting off-gassing problems, before the pursuit of other more tedious analytical approaches. Additionally, the study reveals valuable insight into the characteristic volatile emission of historic medicinal, pharmaceutical, and cosmetic artifacts, increasing understanding of, and decision-making for, similar collections of objects. Eventually, it is hoped that this information can be used to inform mitigation strategies for the capture and reduction of VOCs in collections storage areas.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 3.184
DOI: 10.1007/S11869-021-01054-2
|
|
|
“Measurements of air pollution emission factors for marine transportation in SECA”. Alföldy B, Lööv JB, Lagler F, Bencs L, Horemans B, Van Grieken R, et al, Atmospheric measurement techniques 6, 1777 (2013). http://doi.org/10.5194/AMT-6-1777-2013
Abstract: The chemical composition of the plumes of seagoing ships was measured during a two week long measurement campaign in the port of Rotterdam, Hoek van Holland The Netherlands, in September 2009. Altogether, 497 ships were monitored and a statistical evaluation of emission factors (g kg−1 fuel) was provided. The concerned main atmospheric components were SO2, NO2, NOx and the aerosol particle number. In addition, the elemental and water-soluble ionic composition of the emitted particulate matter was determined. Emission factors were expressed as a function of ship type, power and crankshaft rotational speed. The average SO2 emission factor was found to be roughly half of what is allowed in sulphur emission control areas (16 vs. 30 g kg−1 fuel), and exceedances of this limit were rarely registered. A significant linear relationship was observed between the SO2 and particle number emission factors. The intercept of the regression line, 4.8 × 1015 (kg fuel)−1, gives the average number of particles formed during the burning of 1 kg zero sulphur content fuel, while the slope, 2 × 1018, provides the average number of particles formed with 1 kg sulphur burnt with the fuel. Water-soluble ionic composition analysis of the aerosol samples from the plumes showed that ~144 g of particulate sulphate was emitted from 1 kg sulphur burnt with the fuel. The mass median diameter of sulphate particles estimated from the measurements was ~42 nm.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.5194/AMT-6-1777-2013
|
|
|
“Absorption correction for X-ray-fluorescence analysis of aerosol loaded filters”. Adams FC, Van Grieken RE, Analytical chemistry 47, 1767 (1975). http://doi.org/10.1021/AC60361A040
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60361A040
|
|
|
“Enhancement effect in X-ray fluorescence analysis of environmental samples of medium thickness”. Van Dyck PM, Török SB, Van Grieken RE, Analytical chemistry 58, 1761 (1986). http://doi.org/10.1021/AC00121A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00121A036
|
|
|
“Multiscale modeling of radiation damage and annealing in Si samples implanted with 57-Mn radioactive ions”. Abreu Y, Cruz CM, van Espen P, Piñera I, Leyva A, Cabal AE, IEEE conference record
T2 –, IEEE Nuclear Science Symposium/Medical Imaging Conference (NSS/MIC)/18th, International Workshop on Room-Temperature Semiconductor X-Ray and, Gamma-Ray Detectors, OCT 23-29, 2011, Valencia, SPAIN , 1754 (2011)
Abstract: The radiation damage created in silicon materials by Mn-57 -> Fe-57 ion implantation has been studied and characterized by Mossbauer spectroscopy showing four main lines, assigned to: substitutional, interstitial and damaged configuration sites of the implanted ions. Nevertheless, the Mossbauer spectrum of Fe-57 in this materials remains with some ambiguous identification regarding the implantation configurations before and after annealing, specially the damaged configurations and its evolution. In the present work some possible implantation configurations are suggested and evaluated using a multiscale approach by Monte Carlo ion transport and electronic structure calculations within DFT. The proposed implantation environments were evaluated in terms of stability and the Fe-57 hyperfine parameters were calculated to establish the connections with the experimental observations. Good agreement was found between the experimental and the calculated hyperfine parameters for some configurations; suggesting which ones could be the implantation environments before and after sample annealing.
Keywords: P1 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Elemental compositions of comet 81P/Wild 2 samples collected by Stardust”. Flynn GJ, Janssens K, Vekemans B, [et al], Science 314, 1731 (2006). http://doi.org/10.1126/SCIENCE.1136141
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 37.205
Times cited: 174
DOI: 10.1126/SCIENCE.1136141
|
|
|
“Methods for the determination of platinum group elements originating from the abrasion of automotive catalytic converters”. Bencs L, Ravindra K, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 58, 1723 (2003). http://doi.org/10.1016/S0584-8547(03)00162-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(03)00162-9
|
|
|
“Application of combined micro-proton-induced X-ray emission and micro-synchrotron radiation X-ray fluorescence techniques for the characterization of impact materials around Barringer Meteor Crater”. Uzonyi I, Szöör G, Vekemans B, Vincze L, Rozsa P, Szabo G, Somogyi A, Adams F, Kiss ÁZ, Spectrochimica acta: part B : atomic spectroscopy 59, 1717 (2004). http://doi.org/10.1016/J.SAB.2004.05.030
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2004.05.030
|
|
|
“Monte Carlo simulation of X-ray fluorescence spectra: part 4: photon scattering at high X-ray energies”. Vincze L, Janssens K, Vekemans B, Adams F, Spectrochimica acta: part B : atomic spectroscopy , 1711 (1999). http://doi.org/10.1016/S0584-8547(99)00094-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00094-4
|
|
|
“Elemental x-ray images obtained by grazing-exit electron probe microanalysis (GE-EPMA)”. Tsuji K, Nullens R, Wagatsuma K, Van Grieken RE, Journal of analytical atomic spectrometry 14, 1711 (1999). http://doi.org/10.1039/A905301H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A905301H
|
|
|
“X-ray diffraction mapping for cultural heritage science : a review of experimental configurations and applications”. Gonzalez V, Cotte M, Vanmeert F, de Nolf W, Janssens K, Chemistry: a European journal 26, 1703 (2019). http://doi.org/10.1002/CHEM.201903284
Abstract: X-ray diffraction (XRD) mapping consists in the acquisition of XRD patterns at each pixel (or voxel) of an area (or volume). The spatial resolution ranges from the micrometer (mu XRD) to the millimeter (MA-XRD) scale, making the technique relevant for tiny samples up to large objects. Although XRD is primarily used for the identification of different materials in (complex) mixtures, additional information regarding the crystallite size, their orientation, and their in-depth distribution can also be obtained. Through mapping, these different types of information can be located on the studied sample/object. Cultural heritage objects are usually highly heterogeneous, and contain both original and later (degradation, conservation) materials. Their structural characterization is required both to determine ancient manufacturing processes and to evaluate their conservation state. Together with other mapping techniques, XRD mapping is increasingly used for these purposes. Here, the authors review applications as well as the various configurations for XRD mapping (synchrotron/laboratory X-ray source, poly-/monochromatic beam, micro/macro beam, 2D/3D, transmission/reflection mode). On-going hardware and software developments will further establish the technique as a key tool in heritage science.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 5.317
DOI: 10.1002/CHEM.201903284
|
|
|
“Localised and non-destructive analysis of metallic artefacts from ancient Egypt by means of a compact μ-XRF instrument”. Vittiglio G, Janssens K, Adams F, Oost A, Spectrochimica acta: part B : atomic spectroscopy 54, 1697 (1999). http://doi.org/10.1016/S0584-8547(99)00100-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00100-7
|
|
|
“Organic and inorganic compounds in limestone weathering crusts from cathedrals in Southern and Western Europe”. Fobe BO, Vleugels GJ, Roekens EJ, Van Grieken RE, Hermosin B, Ortega-Calvo JJ, Sanchez del Junco A, Saiz-Jimenez C, Environmental science and technology 29, 1691 (1995). http://doi.org/10.1021/ES00006A038
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES00006A038
|
|
|
“A micro XRF spectrometer based on rotating anode generator and capillary optics”. Janssens K, Vekemans B, Vincze L, Adams F, Rindby A, Spectrochimica acta: part B : atomic spectroscopy 51, 1661 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“2θ-resolution obtainable during – XRPD experiments at Beamline L”. de Nolf W, Jaroszewicz J, Janssens K, Falkenberg G page 1655 (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Chemical composition and deterioration of glass excavated in the 15th-16th century fishermen town of Raversijde (Belgium)”. Schalm O, Caluwé, D, Wouters H, Janssens K, Verhaeghe F, Pieters M, Spectrochimica acta: part A: molecular and biomolecular spectroscopy 59, 1647 (2004). http://doi.org/10.1016/J.SAB.2004.07.012
Abstract: The chemical composition, as determined by electron probe X-ray microanalysis of a series of ca. 100 archaeological glass fragments, excavated at the Raversijde site (Belgium) is discussed. In the 15th-16th century, Raversijde was a flourishing fishermen town located on the shore of the North Sea, close to the city of Ostend. As a consequence of several battles that were fought in its vicinity, the site was abandoned in the 16th century and was not occupied since then. It is one of the rare archaeological sites in Europe that contains a significant amount of information on the daily life inside a small but affluent medieval community. A comparison of the chemical composition of fragments of vessels and window glass encountered in Raversijde to those found in urban centres in Belgium and to literature date on German and French archaeological finds shows that glass made with wood ash dominates. Usually, it concerns artifacts with a predominantly utilitarian use. A few objects made with sodic (i.e., Na-rich) glass were also encountered, likely to have been imported from Venice during the 15th century or in later periods from an urban centre such as Antwerp, where Facon-de-Venice glass manufacturing activities were established near the start of the 16th century. (C) 2004 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.536
Times cited: 26
DOI: 10.1016/J.SAB.2004.07.012
|
|
|
“Confocal microscopic X-ray fluorescence at the HASYLAB microfocus beamline: characteristics and possibilities”. Janssens K, Proost K, Falkenberg G, Spectrochimica acta: part A: molecular and biomolecular spectroscopy 59, 1637 (2004). http://doi.org/10.1016/J.SAB.2004.07.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.536
Times cited: 102
DOI: 10.1016/J.SAB.2004.07.025
|
|
|
“Combined micro-XRF/XRPD tomography on historical and modern paint multilayer samples at Beamline L”. de Nolf W, Jaroszewicz J, van der Snickt G, Janssens K, Farnell S, Klaassen L page 1633 (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Electrocatalytic oxidation of water by OH- –, and H₂O-capped IrOx nanoparticles electrophoretically deposited on graphite and basal plane HOPG : effect of the substrate electrode”. Mirbagheri N, Campos R, Ferapontova EE, Chemelectrochem 8, 1632 (2021). http://doi.org/10.1002/CELC.202100317
Abstract: Iridium oxide (IrOx) is one of the most efficient electrocatalysts for water oxidation reaction (WOR). Here, WOR electrocatalysis by 1.6 nm IrOx nanoparticles (NPs) electrophoretically deposited onto spectroscopic graphite (Gr) and basal plane highly ordered pyrolytic graphite (HOPG) was studied as a function of NPs' capping ligands and electrodeposition substrate. On Gr, OH-- and H2O-capped NPs exhibited close sub-monolayer surface coverages and specific electrocatalytic activity of 18.9-23.5 mA nmol(-1) of Ir-IV/V sites, at 1 V and pH 7. On HOPG, OH--capped NPs produced films with a diminished WOR activity of 5.17 +/- 2.40 mA nmol(-1). Electro-wettability-induced changes impeded electrophoretic deposition of H2O-capped NPs on HOPG, WOR currents being 25-fold lower than observed for OH--capped ones. The electrocatalysis efficiency correlated with hydrophilic properties of the substrate electrodes, affecting morphological and as a result catalytic properties of the formed IrOx films. These results, important both for studied and related carbon nanomaterials systems, allow fine-tuning of electrocatalysis by a proper choice of the substrate electrode.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.136
DOI: 10.1002/CELC.202100317
|
|
|
“Composition of individual aerosol particles above the Israelian Mediterranean coast during the summer time”. Ganor E, Levin Z, Van Grieken R, Atmospheric environment : an international journal 32, 1631 (1998). http://doi.org/10.1016/S1352-2310(97)00397-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1352-2310(97)00397-X
|
|
|
“Preliminary experiment of total reflection x-ray fluorescence using two glancing x-ray beams excitation”. Tsuji K, Sato T, Wagatsuma K, Claes M, Van Grieken R, The review of scientific instruments 70, 1621 (1999). http://doi.org/10.1063/1.1149687
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1063/1.1149687
|
|
|
“Internal mixture of sea salt, silicates, and excess sulfate in marine aerosols”. Andreae MO, Charlson RJ, Bruynseels F, Storms H, Van Grieken R, Maenhaut W, Science 232, 1620 (1986). http://doi.org/10.1126/SCIENCE.232.4758.1620
Abstract: Individual aerosol particles from the remote marine atmosphere were investigated by scanning electron microscopy and electron microprobe analysis. A large fraction of the silicate mineral component of the aerosol was found to be internally mixed with sea-salt aerosol particles. This observation explains the unexpected similarity in the size distributions of silicates and sea salt that has been observed in remote marine aerosols. Reentrainment of dust particles previously deposited onto the sea surface and collision between aerosol particles can be excluded as possible source mechanisms for these internally mixed aerosols. The internal mixing could be produced by processes within clouds, including droplet coalescence. Cloud processes may also be responsible for the observed enrichment of excess (nonsea-salt) sulfate on sea-salt particles.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1126/SCIENCE.232.4758.1620
|
|
|
“Application of electron energy loss spectroscopy to aerosols”. Xhoffer C, Jacob W, Van Grieken R, Journal of aerosol science 20, 1617 (1989). http://doi.org/10.1016/0021-8502(89)90901-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0021-8502(89)90901-4
|
|