“The effect of the buffer solution on the adsorption and stability of horse heart myoglobin on commercial mesoporous titanium dioxide : a matter of the right choice”. Loreto S, Cuypers B, Brokken J, Van Doorslaer S, De Wael K, Meynen V, Physical chemistry, chemical physics 19, 13503 (2017). http://doi.org/10.1039/C6CP08585G
Abstract: Despite the numerous studies on the adsorption of different proteins onto mesoporous titanium dioxide and indications on the important role of buffer solutions in bioactivity, a systematic study on the impact of the buffer on the protein incorporation into porous substrates is still lacking. We here studied the interaction between a commercial mesoporous TiO2 and three of the most used buffers for protein incorporation, i.e. HEPES, Tris and phosphate buffer. In addition, this paper analyzes the adsorption of horse heart myoglobin (hhMb) onto commercial mesoporous TiO2 as a model system to test the influence of buffers on the protein incorporation behavior in mesoporous TiO2. N2 sorption analysis, FT-IR and TGA/DTG measurements were used to evaluate the interaction between the buffers and the TiO2 surface, and the effect of such an interaction on hhMb adsorption. Cyclic voltammetry (CV) and electron paramagnetic resonance (EPR) were used to detect changes in the microenvironment surrounding the heme. The three buffers show a completely different interaction with the TiO2 surface, which drastically affects the adsorption of myoglobin as well as its structure and electrochemical activity. Therefore, special attention is required while choosing the buffer medium to avoid misguided evaluation of protein adsorption on mesoporous TiO2.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.123
Times cited: 2
DOI: 10.1039/C6CP08585G
|
|
|
“The electrochemistry of tetrapropylammonium perruthenate, its role in the oxidation of primary alcohols and its potential for electrochemical recycling”. Lybaert J, Maes BUW, Tehrani KA, De Wael K, Electrochimica acta 182, 693 (2015). http://doi.org/10.1016/J.ELECTACTA.2015.09.107
Abstract: The search for strategies aiming at more sustainable (oxidation) reactions has led to the application of electrochemistry for recycling the spent catalyst. In this work, an electrochemical study of the tetrapropylammonium perruthenate catalyst (TPAP) and its activity towards a primary alcohol, n-butanol, has been carried out as well as a control study with tert-butanol. The redox chemistry of TPAP and the transition between the perruthenate anion and ruthenium tetroxide in a non-aqueous solvent have been, for the first time, investigated in depth. The oxidation reaction of n-butanol in the presence of TPAP has been electrochemically elucidated by performing potentiostatic experiments and registration of the corresponding oxidation current. Furthermore, it was shown that, by applying a specific potential, the reoxidized TPAP is able to oxidize/convert the primary alcohol, paving the way for practical applications using TPAP in electrochemical synthesis. The conversion of n-butanol into n-butanal was proven by the use of GC-MS.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Organic synthesis (ORSY)
Impact Factor: 4.798
Times cited: 2
DOI: 10.1016/J.ELECTACTA.2015.09.107
|
|
|
“Mediated electrolysis of vicinal diols by neocuproine palladium catalysts”. Lybaert J, Tehrani KA, De Wael K, Electrochimica acta 247, 685 (2017). http://doi.org/10.1016/J.ELECTACTA.2017.07.044
Abstract: Synthetic electrochemistry agrees well with the principles of sustainable chemistry, therefore it is considered as a more environmentally friendly approach than some current synthetic methods Here, we present a new strategy for the chemoselective oxidation of vicinal diols, viz. the integration of neocuproine palladium catalysts and electrosynthesis. Benzoquinones are used as an effective mediator as the reduced species (hydroquinones) can be easily reoxidized at relative low potentials at an electrode surface. NeocuproinePd(OAc)2 efficiently works as a catalyst in an electrolysis reaction for vicinal diols at room temperature. This is a remarkable observation given the fact that aerobic oxidation reactions of alcohols typically need a more complex catalyst, i.e. [neocuproinePdOAc]2[OTf]2. In this article we describe the optimization of the electrolysis conditions for the neocuproinePd(OAc)2 catalyst to selectively oxidize diols. The suggested approach leads to conversion of alcohols with high yields and provides an interesting alternative to perform oxidation reactions under mild conditions by the aid of electrochemistry.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Organic synthesis (ORSY)
Impact Factor: 4.798
DOI: 10.1016/J.ELECTACTA.2017.07.044
|
|
|
“Cooperative electrocatalytic and chemoselective alcohol oxidation by Shvo's catalyst”. Lybaert J, Trashin S, Maes BUW, De Wael K, Abbaspour Tehrani K, Advanced synthesis and catalysis 359, 919 (2017). http://doi.org/10.1002/ADSC.201600783
Abstract: A new electrocatalytic conversion of alcohols to ketones and aldehydes was developed based on an electrochemical study of Shvos complex. The oxidation of secondary alcohols was efficiently performed under mild conditions using a catalytic amount of Shvos catalyst, in combination with a sub-stoichiometric amount of 2,6-dimethoxy-1,4- benzoquinone in N,N-dimethylformamide at 80 8C. The hydroquinone thus formed is continuously reoxidized with the aid of an electrochemical device. Excellent yields for different ketones, aromatic as well as aliphatic and a,b-unsaturated ketones, are obtained. In addition, chemoselectivity towards oxidation of the secondary alcohol is achieved when converting vicinal diols such as 1,2-octanediol and 1,2-decanediol.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Organic synthesis (ORSY)
Impact Factor: 5.646
Times cited: 4
DOI: 10.1002/ADSC.201600783
|
|
|
“Revealing the distribution of metal carboxylates in oil paint from the micro- to nanoscale”. Ma X, Beltran V, Ramer G, Pavlidis G, Parkinson DY, Thoury M, Meldrum T, Centrone A, Berrie BH, Angewandte Chemie: international edition in English 58, 11652 (2019). http://doi.org/10.1002/ANIE.201903553
Abstract: Oil paints comprise pigments, drying oils, and additives that together confer desirable properties, but can react to form metal carboxylates (soaps) that may damage artworks over time. To obtain information on soap formation and aggregation, we introduce a new tapping-mode measurement paradigm for the photothermal induced resonance (PTIR) technique that enables nanoscale IR spectroscopy and imaging on highly heterogenous and rough paint thin sections. PTIR is used in combination with mu-computed tomography and IR microscopy to determine the distribution of metal carboxylates in a 23-year old oil paint of known formulation. Results show that heterogeneous agglomerates of Al-stearate and a Zn-carboxylate complex with Zn-stearate nano-aggregates in proximity are distributed randomly in the paint. The gradients of zinc carboxylates are unrelated to the Al-stearate distribution. These measurements open a new chemically sensitive nanoscale observation window on the distribution of metal soaps that can bring insights for understanding soap formation in oil paint.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/ANIE.201903553
|
|
|
“Geoquimica dos microclasticos da Bacio do Parnaiba”. Mabesoone JM, Duarte PJ, Van Grieken R, Delgao A, Freire EMP page 30 (1985).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Parnaiba Basin shales (Northeast Brazil)”. Mabesoone JM, Farias CC, Van Grieken R, Duarte PJ, Delgado A, Freira EMP, Anais da Academia Brasileira de Ciências 57, 481 (1985)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Rembrandt's An Old Man in Military Costume : combining hyperspectral and MA-XRF imaging to understand how two paintings were painted on a single panel”. MacLennan D, Trentelman K, Szafran Y, Woollett AT, Delaney JK, Janssens K, Dik J, Journal of the American Institute for Conservation 58, 54 (2019). http://doi.org/10.1080/01971360.2018.1540245
Abstract: Over the past several decades the painting An Old Man in Military Costume by Rembrandt Harmensz van Rijn (ca. 1630-31; J. Paul Getty Museum, 78.PB.246) has been the subject of a number of investigations carried out in order to better visualize a second painting beneath the surface figure. The underlying image – the head and shoulders of a man wearing a cloak – is oriented 180 degrees from the upper image and appears to be fairly complete. Scanning macro x-ray fluorescence (XRF) spectroscopy reveals the face is painted with lead white and a mercury-containing pigment (likely vermilion), and the cloak is painted with a copper-containing pigment. Following the revelation and digital color reconstruction of the underlying figure, a number of questions still remained. Here, through the use of infrared reflectance imaging spectroscopy (i.e., hyperspectral imaging) and macro-XRF imaging spectroscopy, together with cross-sections taken from targeted areas, the sequence of painting in both compositions was explored. Of particular interest was the discovery of evidence of multiple attempts to situate the lower figure, and the subsequent application of a blocking-out layer over the lower figure before the artist rotated the panel and executed the upper figure. In addition, examination of the placement of the two images on the panel adds to our understanding of the subtle complexities of Rembrandt's working process. RESUMEAu cours des dernieres decennies, la peinture Le vieil homme en costume militaire de Rembrandt Harmensz van Rijn (ca. 1630-31; J. Paul Getty Museum, 78.PB.246) a fait l'objet de nombreuses investigations menees dans le but de mieux visualiser une seconde peinture dissimulee sous la surface. L'image sous-jacente – la tete et les epaules d'un homme vetu d'une cape – est orientee a 180 degres de de l'image du vieil homme, et elle semble assez complete. La spectroscopie a macro-balayage de fluorescence X (MA-XRF) revele que le visage est peint avec du blanc de plomb et un pigment contenant du mercure (comme le vermillon), et que la cape est peinte avec un pigment a base de cuivre. Plusieurs questions restaient en suspens suite a cette decouverte et a la reconstruction numerique en couleur de l'image sous-jacente. Grace a l'emploi de techniques d'imagerie comme la spectroscopie proche infrarouge (ex., imagerie hyperspectrale) et l'imagerie MA-XRF, combinees a l'analyse de coupes stratigraphiques prelevees a des endroits cibles, on a pu explorer la sequence d'application des couches picturales de chacune des deux compositions. Une decouverte particulierement interessante est la preuve que l'artiste a fait plusieurs tentatives pour positionner la figure sous-jacente puis, a ensuite applique une couche pour la recouvrir completement avant de faire pivoter le panneau et peindre la figure du vieil homme. De plus, l'examen du positionnement des deux images sur le panneau ajoute a notre comprehension de la subtile complexite du processus de creation de Rembrandt. Traduit par Elisabeth Forest. RESUMONas ultimas decadas, a pintura Um Velho em Traje Militar, de Rembrandt Harmensz van Rijn (ca. 1630-31; J. Paul Getty Museum, 78.PB.246), foi objeto de uma serie de investigacoes realizadas para visualizar melhor uma segunda pintura abaixo da figura aparente. A imagem subjacente – a cabeca e os ombros de um homem usando uma capa – e orientada a 180 graus da imagem superior e parece estar bastante completa. O macro mapeamento de imagem por espectroscopia de fluorescencia de raios X (FRX) revela que a face e pintada com branco de chumbo e um pigmento contendo mercurio (provavelmente vermelhAo), e a capa e pintada com um pigmento contendo cobre. Apos a descoberta e reconstrucAo digital da cor da figura subjacente, uma serie de questoes ainda permanecem. EntAo, atraves da utilizacAo do mapeamento por imagem de espectroscopia de refletancia por infravermelhos (i.e. mapeamento hiperespectral) e macro mapeamento por imagem de FRX, juntamente com cortes estratigraficos de amostras retiradas de areas de interesse, a pintura em ambas as composicoes foi explorada. De particular interesse foi a descoberta de evidencias de multiplas tentativas de posicionar a figura subjacente, e a subsequente aplicacAo de uma camada intermediaria de separacAo sobre a figura inferior antes do artista girar o painel e executar a figura superior. Alem disso, o exame da colocacAo das duas imagens no painel aumenta nossa compreensAo das sutis complexidades do processo de trabalho de Rembrandt. Traduzido por Marcia Rozzi e Beatriz Haspo. RESUMENA lo largo de las ultimas decadas, la pintura Un anciano con traje militar de Rembrandt Harmensz van Rijn (ca. 1630-31; J. Paul Getty Museum, 78.PB.246) ha sido objeto de varias investigaciones realizadas con el fin de visualizar mejor una segunda pintura debajo de la figura de la superficie. La imagen subyacente, la cabeza y los hombros de un hombre que lleva una capa, esta orientada a 180 grados de la imagen superior y parece estar bastante completa. La espectroscopia de fluorescencia de rayos X (XRF) de barrido revela que la cara esta pintada con blanco de plomo y un pigmento que contiene mercurio (probablemente bermellon), y la capa esta pintada con un pigmento que contiene cobre. Tras la revelacion y la reconstruccion digital del color de la figura subyacente, aun quedaban algunas preguntas. Aqui, por medio del uso de la espectroscopia de imagenes de reflectancia infrarroja (es decir, imagenes hiperespectrales) e imagenes macro-XRF, junto con las secciones transversales tomadas de areas especificas, se exploro la secuencia de pintura en ambas composiciones. De particular interes fue el descubrimiento de evidencia de multiples intentos de situar la figura inferior, y la aplicacion posterior de una capa de bloqueo sobre la figura inferior antes de que el artista rotara el panel y ejecutara la figura superior. Ademas, el examen de la colocacion de las dos imagenes en el panel contribuye a nuestra comprension de las sutiles complejidades del proceso de trabajo de Rembrandt. Traduccion: Amparo Rueda.
Keywords: A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 2
DOI: 10.1080/01971360.2018.1540245
|
|
|
“Characterization of the atmospheric aerosol over the eastern equatorial Pacific”. Maenhaut W, Raemdonck H, Selen A, Van Grieken R, Winchester JW, Journal of geophysical research 88, 5353 (1983). http://doi.org/10.1029/JC088IC09P05353
Abstract: By using a polyester sailboat as sampling platform, a series of duplicate aerosol samples was collected by cascade impactors on a trip from Panama to Tahiti in 1979. Elemental analysis mainly by particle-induced X ray emission (PIXE) indicated, in the samples collected between Panama and the Galapagos Islands, the presence of a substantial crustal component (∼0.4 μg/m3), fine Cu (∼0.4 ng/m3) and Zn (∼0.6 ng/m3), and excess fine S and K (∼100 and ∼2.4 ng/m3, respectively) in addition to the major sea salt elements. The crustal component and fine Cu and Zn are suggested to result from natural continental sources (i.e., eolian dust transport from the American continents and perhaps geothermal emissions). Samples collected west of the Galapagos Islands in the southern trades showed significantly lower concentrations for the nonseawater components. The average Si and Fe levels were as low as 4.8 and 3.3 ng/m3, corresponding to a maximum of 0.066 μg/m3 for an assumed mineral dust component, whereas heavy metal concentrations were all below the detection limits (typically ranging from 0.05 to 0.15 ng/m3 for V, Cr, Mn, Ni, Cu, Zn, and Se). Excess fine S decreased to a mean of 46 ng/m3, a level similar to those reported for other remote marine and continental locations. This all indicates that the marine atmosphere west of the Galapagos was little influenced by natural continental source processes or by anthropogenic emissions. Under these truly marine conditions, several concentration ratios of the major seawater elements were significantly different from those in bulk seawater. Ca, Sr, and S in >1 μm diameter particles were enriched relative to K and Na, with the enrichment being substantially more pronounced (up to 50% or higher) for l4-μm diameter particles than for particles >4 μm. Comparison of these data with a similar data set from samples collected over the Atlantic indicates that the departures from seawater composition are significantly larger for the Pacific. Differences in sea-to-air fractionation processes, probably involving binding of divalent cations to organic matter in the oceanic surface microlayer, are suggested as being responsible for these observations.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1029/JC088IC09P05353
|
|
|
“Sulfur and heavy metals over the Atlantic Ocean : comparison with other marine data”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester JW, (1980)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Pixe analysis of aerosol samples collected over the atlantic-ocean from a sailboat”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester WJ, Nuclear instruments and methods 181, 399 (1981). http://doi.org/10.1016/0029-554X(81)90640-6
Abstract: Size-fractionated aerosol samples, collected over the Atlantic Ocean, were analyzed for up to 20 elements by PIXE. Using a sailboat as sampling platform, duplicate samples were taken for two-day periods by means of battery operated 6-stage cascade impactors, positioned about 8 m above the sea surface. In the PIXE analysis of the fine particle stages (stages 3 to 5) a 5 times smaller beam size was used than for stages 1 and 2. This led to significant improvement in the detection limits for the former stages. The results from the duplicate impactor samples were normally in good agreement, indicating that the combined uncertainty of sampling and PIXE analysis was of the order of 20%. The precision of the PIXE analysis alone was investigated by rebombarding some samples six months after the first analysis. The trends with time of the fine particle sulfur and the coarse particle iron concentrations are discussed in some detail.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0029-554X(81)90640-6
|
|
|
“Atmospheric trace element concentrations in Jerusalem, Israel”. Malenky B, Van Grieken R, Van 't dack L, Luria M, Atmospheric environment 17, 819 (1983). http://doi.org/10.1016/0004-6981(83)90432-8
Abstract: Trace elements found in aerosols were monitored in Jerusalem during the 1979 winter season utilizing an X-ray fluoresence technique. Most of the particulate mass was associated with the natural soil elements, such as Ca, Fe, K and Ti. Only a small fraction of the mass was comprised of elements clearly emitted from human sources, e.g. Pb, Br, V, Ni and Zn. An excellent correspondence was found between the enrichment factors observed in this study and those postulated for other parts of the world. However, the concentration of Ca and Sr in the Jerusalem suspended dust is substantially higher when compared with world averages of urban aerosols.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0004-6981(83)90432-8
|
|
|
Marchetti A (2021) Novel insights and approaches for the analytical characterization of tangible cultural heritage objects. 333 p
Abstract: Cultural heritage represents the vehicle of our cultural identity, handed over from past to future generations throughout human history. As a repository of fundamental cultural and social values, the preservation of all forms of cultural heritage is a responsibility of every society and of humankind as a whole. When it comes to tangible cultural heritage, preservation of heritage translates into preservation of objects and, therefore, of the materials they are constituted of. This crucial task relies heavily on the application of scientific analytical methods to answer material and conservation-related questions. The fundamental contribution of this analytical approach led, in the past decades, to an ever-deepening understanding of the factors governing the degradation of cultural heritage. However, the extreme complexity of the heritage object-environment system results in a massive research field, which inevitably presents relevant open questions. This is where the present PhD work comes into play, attempting to fill knowledge gaps in literature by starting from specific case studies and un-answered research questions. The multianalytical research conducted during this PhD unraveled fundamental information on the properties governing the reactivity and long-term behavior of different classes of materials, from α-brass in an indoor environment to artists’ pigments in the presence of light, moisture and soluble particulate matter (PM). The paramount importance of the synthesis conditions on the composition, physical properties and reactivity of heritage materials was also demonstrated, in particular for stable lead pyroantimonate and unstable Geranium lake artists’ pigments. Moreover, the study and characterization of specific heritage objects, namely a series of 16th century reliquary altarpieces and the painting L’Arlesienne, by Vincent Van Gogh, allowed to obtain relevant insights into their composition and on potential risks for their conservation. The challenging nature of the samples considered, created the perfect opportunity to test an innovative spectroscopic technique, optical photo-thermal IR (O-PTIR), for the characterization of heritage materials. Striking results were obtained, highlighting a great potential for the application of this non-destructive sub-micron molecular spectroscopy to the analysis of cultural heritage. Finally, in the last section of this work, strategies to implement the continuous monitoring of PM levels in indoor environmental quality studies were also considered, with a particular focus on the identification of environmental hazards for the collections housed in specific conservation environments (War Heritage Institute in Brussels and St. Martin’s church in Aalst, BE).
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Indoor environmental quality index for conservation environments : the importance of including particulate matter”. Marchetti A, Pilehvar S, 't Hart L, Leyva Pernia D, Voet O, Anaf W, Nuyts G, Otten E, Demeyer S, Schalm O, De Wael K, Building and environment 126, 132 (2017). http://doi.org/10.1016/J.BUILDENV.2017.09.022
Abstract: It is commonly known that the conservation state of works of arts exhibited inside museums is strongly influenced by the indoor environmental quality (IEQ). Heritage institutions traditionally record and evaluate their IEQ by monitoring temperature, relative humidity, and -more rarely-light. However, smart use of technology enables monitoring other parameters that give a more complete insight in environmental air aggressiveness. One of this parameters is particulate matter (PM) and especially its concentration, size distribution and chemical composition. In this work, we present a selection of data sets which were obtained in a measuring campaign performed in the War Heritage Institute in Brussels, Belgium. A continuous monitoring of PM concentration with a light scattering based particle counter was performed. In addition the daily mass concentration and size distribution of airborne PM was monitored by means of Harvard impactors. The chemical composition of sampled PM was inferred from the results of XRF and IC analysis. The insights from these datasets are combined with the results of traditional environmental monitoring (temperature, relative humidity and light intensity), and assessed against the recommended guidelines for conservation environments. By using an integrated approach based on the calculation of an IEQ-index, we present a straightforward methodology to evaluate and visualize the IEQ including also continuous PM monitoring. It is clear from the results of this study how including PM in IEQ analysis allows to identify potential risks for museum collections that remain invisible when only traditional parameters are considered.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Systems and software Modelling (AnSyMo); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 4.053
Times cited: 10
DOI: 10.1016/J.BUILDENV.2017.09.022
|
|
|
“Unraveling the Role of Lattice Substitutions on the Stabilization of the Intrinsically Unstable Pb2Sb2O7Pyrochlore: Explaining the Lightfastness of Lead Pyroantimonate Artists&rsquo, Pigments”. Marchetti A, Saniz R, Krishnan D, Rabbachin L, Nuyts G, De Meyer S, Verbeeck J, Janssens K, Pelosi C, Lamoen D, Partoens B, De Wael K, Chemistry Of Materials 32, 2863 (2020). http://doi.org/10.1021/acs.chemmater.9b04821
Abstract: The pyroantimonate pigments Naples yellow and lead tin antimonate yellow are recognized as some of the most stable synthetic yellow pigments in the history of art. However, this exceptional lightfastness is in contrast with experimental evidence suggesting that this class of mixed oxides is of semiconducting nature. In this study the electronic structure and light-induced behavior of the lead pyroantimonate pigments were determined by means of a combined multifaceted analytical and computational approach (photoelectrochemical measurements, UV-vis diffuse reflectance spectroscopy, STEM-EDS, STEM-HAADF, and density functional theory calculations). The results demonstrate both the semiconducting nature and the lightfastness of these pigments. Poor optical absorption and minority carrier mobility are the main properties responsible for the observed stability. In addition, novel fundamental insights into the role played by Na atoms in the stabilization of the otherwise intrinsically unstable Pb2Sb2O7 pyrochlore were obtained.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT)
Impact Factor: 8.6
Times cited: 8
DOI: 10.1021/acs.chemmater.9b04821
|
|
|
“X-ray fluorescence analysis, sample preparation for”. Margu'i' E, Queralt I, Van Grieken R page 1 (2009).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“High-energy polarized-beam energy-dispersive X-ray fluorescence analysis combined with activated thin layers for cadmium determination at trace levels in complex environmental liquid samples”. Marguí, E, Fontàs C, van Meel K, Van Grieken R, Queralt I, Hidalgo M, Analytical chemistry 80, 2357 (2008). http://doi.org/10.1021/AC7018427
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC7018427
|
|
|
“Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks”. Margui E, Hidalgo M, Queralt I, van Meel K, Fontas C, Spectrochimica acta: part B : atomic spectroscopy 67, 17 (2012). http://doi.org/10.1016/J.SAB.2011.12.004
Abstract: We aimed to achieve improved instrumental sensitivity and detection limits for the analysis of several elements (Cu, Ni, Zn, Pb and Cd) in aqueous samples with energy dispersive X-ray fluorescence spectrometry (EDXRF). The metals were pre-concentrated from aqueous solutions using commercially available organic-based solid-phase extraction (SPE) disks functionalized with iminodiacetate groups. These thin-layer organic materials provide an ideal support for XRF analysis. The elements were collected on the SPE extraction disks using a simple filtration procedure (starting with 1 L of aqueous sample) that allows direct XRF measurements to be performed in the field (in situ). We evaluated the analytical possibilities and drawbacks of using this pre-concentration procedure in combination with the following XRF configurations: a handheld unit, a benchtop EDXRF system and a high-energy polarized-beam EDXRF instrument (HE-P-EDXRF). Using the HE-P-EDXRF system, the detection limits for all metals were more than one order of magnitude lower than those attained using handheld and benchtop EDXRF instrumentation. For the detection of metal concentrations higher than similar to 20 mu g/L, however, handheld or benchtop systems remain a very good option due to their extreme simplicity of operation and low-cost, compact design. We demonstrate the application of these methodologies, using the three equipment systems, to the analysis of trace concentrations of metals in different types of aqueous samples, including tap water and waste water. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2011.12.004
|
|
|
“High-energy polarized-beam EDXRF for trace metal analysis of vegetation samples in environmental studies”. Marguí, E, Padilla R, Hidalgo M, Queralt I, Van Grieken R, X-ray spectrometry 35, 169 (2006). http://doi.org/10.1002/XRS.890
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.890
|
|
|
“Overview of most commonly used analytical techniques for elemental analysis”. Margui E, Van Grieken R, Petro Industry News , 8 (2014)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“State-of-the-art X-ray fluorescence instrumentation for chemical analysis”. Margui E, Van Grieken R, Petro Industry News , 16 (2013)
Abstract: Nowadays, X-ray fluorescence spectrometry (XRF) is a well-established analytical technique for qualitative and quantitative elemental analysis (sometimes from Be to U) of a wide variety of samples. In particular, the truly multi-element character, acceptable speed and economy, ease of automation and the possibility to directly analyse solid samples are the most important features among the many that have made it a very mature analytical tool for routine quality controls in many industries, as well as for analytical support for the research laboratory.e recent technological advances, including the design of low-power micro-focus tubes and the novel X-ray optics and detectors have made it possible to extend XRF to the determination of low-Z elements and to obtain 2D or 3D information on a micrometre-scale. Furthermore, the recent development and commercialisation of benchtop and portable instrumentation, that offer extreme simplicity of operation in a low-cost design, have promoted even more the approach of XRF for many analytical problems.is article highlights this state-of-the art technique with regards to currently available XRF instrumentation on the market as well as recent applications in environmental and industrial fields.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Marguí, E, Van Grieken R (2013) X-ray fluorescence spectrometry and related techniques : an introduction. 148 p
Keywords: MA3 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Preconcentration methods for the analysis of liquid samples by X-ray fluorescence techniques”. Marguí, E, Van Grieken R, Fontàs C, Hidalgo M, Queralt I, Applied spectroscopy reviews 45, 179 (2010). http://doi.org/10.1080/05704920903584198
Abstract: This article gives an overview of the state-of-the-art of multi-element and single-element preconcentration procedures prior to X-ray fluorescence (XRF) analysis of liquid samples. Many of these preconcentration methods were developed long ago and the purpose of this review is to present some new efficient variations of these methods and new techniques extending the possibilities of XRF for liquid solutions analysis. In addition, trends and future perspectives in this domain are also commented on and discussed in the last section of the review.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/05704920903584198
|
|
|
“Method for the determination of Pd-catalyst residues in active pharmaceutical ingredients by means of high-energy polarized-beam energy dispersive X-ray fluorescence”. Marguí, E, van Meel K, Van Grieken R, Buendía A, Fontás C, Hidalgo M, Queralt I, Analytical chemistry 81, 1404 (2009). http://doi.org/10.1021/AC8021373
Abstract: In medicinal chemistry, Pd is perhaps the most-widely utilized precious metal, as catalyst in reactions which represent key transformations toward the synthesis of new active pharmaceutical ingredients (APIs). The disadvantage of this metal-catalyzed chemistry is that expensive and toxic metal residues are invariably left bound to the desired product. Thus, stringent regulatory guidelines exist for the amount of residual Pd that a drug candidate is allowed to contain. In this work, a rapid and simple method for the determination of Pd in API samples by high-energy polarized-beam energy dispersive X-ray fluorescence spectrometry has been developed and validated according to the specification limits of current legislation (10 mg kg−1 Pd) and the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH guidelines). Sample and calibration standards preparation includes a first step of homogenization and then, in a second step, the pressing of the powdered material into pellets without any chemical treatment. The use of several synthetic calibration standards made of cellulose to simulate the API matrix appears to be an effective means to obtain reliable calibration curves with a good spread of data points over the working range. With the use of the best measuring conditions, the limit of detection (0.11 mg kg−1 Pd) as well as the limit of quantitation (0.37 mg kg−1 Pd) achieved meet rigorous requirements. The repeatability of the XRF measurement appeared to be less than 2%, while the precision of the whole method was around 7%. Trueness was evaluated by analyzing spiked API samples at the level of the specification limit and calculating the recovery factor, which was better than 95%. To study the applicability of the developed methodology for the intended purpose, three batches of the studied API were analyzed for their Pd content, and the attained results were comparable to those obtained by the daily routine method (acid digestion plus atomic spectroscopy) used in most pharmaceutical laboratories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC8021373
|
|
|
“Analytical electron microscopy of single particles”. Markowicz A, Raeymaekers B, Van Grieken R, Adams F page 173 (1986).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
|
|
“A simple absorption correction for electron probe X-ray microanalysis of bulk samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 115 (1986). http://doi.org/10.1002/XRS.1300150209
Abstract: A simple procedure is proposed for the calculation of the absorption correction factor in electron-probe x-ray microanalysis. It is based on the concept of an effective depth of x-ray production, assuming a rectangular depth distribution function for x-ray generation. This effective x-ray production depth is expressed as a fraction of the x-ray excitation depth given by Whelan's expression. Adequate values for this fraction are presented. Two versions are considered. In the first the effective x-ray production is a function of both the characteristic x-ray energy and the atomic numbers of the matrix elements, whereas in the second one, which is indicated for routine use, the energy dependence is neglected. Calculations pointed to satisfactory results, even for low x-ray energies and high overvoltages.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150209
|
|
|
“Radiometric diameter concept and exact intensities for spherical particles in x-ray fluorescence analysis”. Markowicz A, Van Dyck P, Van Grieken R, X-ray spectrometry 9, 52 (1980). http://doi.org/10.1002/XRS.1300090205
Abstract: In X-ray fluorescence analysis the concept of radiometric diameter, d, is often introduced in considerations of the fluorescent intensity from a particulate sample. It represents the mean geometric path of the X-rays through one particle and is usually simply taken to be equal to the volume-to-area ratio of the particle. The effective radiometric path is, however, itself dependent on geometry and absorption effects. Rigorous calculations of the fluorescent intensity from a particle in the π and π/2 geometries were carried out to evaluate the errors involved. It appears that, for π geometry, the discrepancy between these exact results and the intensity calculated via the use of d does not exceed 5.2%. For the π/2 geometry, the errors are much larger and can amount to 50% in realistic cases of X-ray fluorescence analysis. These conclusions are also applicable to monolayers. The effective radiometric diameter approaches d only when absorption effects become negligible, but is smaller in other cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300090205
|
|
|
“Absorption correction in electron probe x-ray microanalysis of thin samples”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 58, 1282 (1986). http://doi.org/10.1021/AC00298A003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00298A003
|
|
|
“Bremsstrahlung background in electron-probe X-ray-microanalysis of thin films”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 57, 2885 (1985). http://doi.org/10.1021/AC00291A032
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00291A032
|
|