“Static secondary ion mass spectrometry (S-SIMS): part 1: methodology and structural interpretation”. van Vaeck L, Adriaens A, Gijbels R, Mass spectrometry reviews 18, 1 (1999)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 9.373
Times cited: 112
|
“Structural aspects of CVD idamond wafers grown at different hydrogen flow rates”. Nistor L, van Landuyt J, Ralchenko V, Physica status solidi: A: applied research 171, 5 (1999). http://doi.org/10.1002/(SICI)1521-396X(199907)174:1<5::AID-PSSA5>3.3.CO;2-3
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 15
DOI: 10.1002/(SICI)1521-396X(199907)174:1<5::AID-PSSA5>3.3.CO;2-3
|
“Structural determination of the charge ordering process in Nd0.5Ca0.5Mn1-xCrxO3 manganites”. Schuddinck W, Van Tendeloo G, Barnabé, A, Hervieu M, Raveau B, Journal of solid state chemistry 148, 333 (1999). http://doi.org/10.1006/jssc.1999.8457
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.299
Times cited: 12
DOI: 10.1006/jssc.1999.8457
|
“Structural transformations in the fluorinated T* phase”. Hadermann J, Abakumov AM, Lebedev OI, Van Tendeloo G, Rozova MG, Shpanchenko RV, Pavljuk BP, Kopnin EM, Antipov EV, Journal of solid state chemistry 147, 647 (1999). http://doi.org/10.1006/jssc.1999.8438
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.299
Times cited: 8
DOI: 10.1006/jssc.1999.8438
|
“A study of the domain structure of epitaxial (La-Ca)MnO3 films by high-resolution transmission electron microscopy”. Lebedev OI, Van Tendeloo G, Abakumov AM, Amelinckx S, Leibold B, Habermeier H-U, Philosophical magazine: A: physics of condensed matter: defects and mechanical properties 79, 1461 (1999). http://doi.org/10.1080/01418619908210372
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 27
DOI: 10.1080/01418619908210372
|
“Surface analysis of halide distributions in complex AgX microcrystals by imaging time-of-flight SIMS (TOF-SIMS)”. Verlinden G, Gijbels R, Geuens I, de Keyzer R, Journal of analytical atomic spectrometry 14, 429 (1999). http://doi.org/10.1039/a807276k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 10
DOI: 10.1039/a807276k
|
“Synthesis of single wall carbon nanotubes by catalytic decomposition of hydrocarbons”. Colomer J-F, Bister G, Willems I, Konya Z, Fonseca A, Van Tendeloo G, Nagy JB, Chemical communications , 1343 (1999). http://doi.org/10.1039/a903142a
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 6.319
Times cited: 110
DOI: 10.1039/a903142a
|
“_Fe2O3 nanoparticles with mesoporous MCM-48 silica: in situ formation and characterisation”. Fröba M, Köhn R, Bouffaud G, Richard O, Van Tendeloo G, Chemistry of materials 11, 2858 (1999). http://doi.org/10.1021/cm991048i
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 9.466
Times cited: 202
DOI: 10.1021/cm991048i
|
“YBa2Cu3O7-x Josephson junctions and dc SQUIDs based on 45\text{\textdegree} a-axis tilt and twist grain boundaries : atomically clean interfaces for applications”. Tafuri F, Carillo F, Lombardi F, Granozio FM, dii Uccio US, Testa G, Sarnelli E, Verbist K, Van Tendeloo G, Superconductor science and technology
T2 –, International Superconductive Electronics Conference, JUN 21-25, 1999, BERKELEY, CALIFORNIA 12, 1007 (1999). http://doi.org/10.1088/0953-2048/12/11/393
Abstract: YBa2Cu3O7-x artificial grain boundary Josephson junctions have been fabricated, employing a recently implemented biepitaxial technique. The grain boundaries can be obtained by controlling the orientation of the MgO seed layer and are characterized by a misalignment of the c-axes (45 degrees a-axis tilt or 45 degrees a-axis twist). These types of grain boundaries are still mostly unexplored. We carried out a complete characterization of their transport properties and microstructure. Junctions and de SQUIDs associated with these grain boundaries exhibit an excellent Josephson phenomenology and high values of the ICRN product and of the magnetic flux-to-voltage transfer parameter respectively. Remarkable differences in the transport parameters of tilt and twist junctions have been observed, which can be of interest for several applications. A maximum speed of Josephson vortices as calculated from the voltage step values of the order of 2 x 10(6) m s(-1) is obtained. These devices could also have some impact on experiments designed to study the symmetry of the order parameter, exploiting their microstructure and anisotropic properties. High-resolution electron microscopy showed the presence of perfect basal plane faced boundaries in the cross sections of tilt boundaries.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.878
Times cited: 3
DOI: 10.1088/0953-2048/12/11/393
|
“The two electron artificial molecule”. Partoens B, Matulis A, Peeters FM, Physical review : B : condensed matter and materials physics 59, 1617 (1999). http://doi.org/10.1103/PhysRevB.59.1617
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 34
DOI: 10.1103/PhysRevB.59.1617
|
“Weakly localized biexcitons in quantum wells”. Mayrock O, Wünsche H-J, Henneberger F, Riva C, Schweigert VA, Peeters FM, Physical review : B : condensed matter and materials physics 60, 5582 (1999). http://doi.org/10.1103/PhysRevB.60.5582
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 17
DOI: 10.1103/PhysRevB.60.5582
|
“XPS and TOFSIMS studies of shallow Si/Si1-xGex/Si layers”. Conard T, de Witte H, Loo R, Verheyen P, Vandervorst W, Caymax M, Gijbels R, Thin solid films : an international journal on the science and technology of thin and thick films 343/344, 583 (1999). http://doi.org/10.1016/S0040-6090(99)00122-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.879
Times cited: 1
DOI: 10.1016/S0040-6090(99)00122-4
|
“Zr substituted bismuth uranate”. Vannier R-N, Théry O, Kinowski C, Huvé, M, Van Tendeloo G, Suard E, Abraham F, Journal of materials chemistry 9, 435 (1999). http://doi.org/10.1039/a805829f
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 4
DOI: 10.1039/a805829f
|
“Analyses of petrified wood by electron, X-ray and optical microprobes”. Kuczumov A, Vekemans B, Schalm O, Dorriné, W, Chevallier P, Dillmann P, Ro C-U, Janssens K, Van Grieken R, Journal of analytical atomic spectroscopy 14, 435 (1999). http://doi.org/10.1039/A806748A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A806748A
|
“Chemische en morfologische karakterisatie van de grissailles van Capronnier met behulp van EPXMA”. Schalm O, Janssens K, Caen J, Adams F, (1999)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Compositional distinctions between 16th century “Façon-de-Venise&rdquo, and Venetian glass vessels, excavated in Antwerp, Belgium”. Deraedt I, Janssens K, Veeckman J, Journal of analytical atomic spectroscopy 14, 483 (1999). http://doi.org/10.1039/A808385A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A808385A
|
“Echt of namaak? Venetiaans glas uit het oude Antwerpen”. de Raedt I, Janssens K, Veeckman J, De wetenschappelijke bibliotheek 67, 58 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Feasibility of (trace-level) micro-XANES at Beamline L”. Janssens K, Vincze L, Wei F, Proost K, Vekemans B, Vittiglio G, Yan Y, Falkenberg G (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Fluorescent tomography of phantom samples at the beamline L”. Vekemans B, Vincze L, Vittiglio G, Janssens K, Adams F, HASYLAB Jahresbericht (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Localised and non-destructive analysis of metallic artefacts from ancient Egypt by means of a compact μ-XRF instrument”. Vittiglio G, Janssens K, Adams F, Oost A, Spectrochimica acta: part B : atomic spectroscopy 54, 1697 (1999). http://doi.org/10.1016/S0584-8547(99)00100-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00100-7
|
“Micro-analysis of artists' pigments by grazing-emission X-ray fluorescence spectrometry”. Claes M, van Ham R, Janssens K, Van Grieken R, Klockenkämper R, von Bohlen A, Advances in X-ray analysis 41, 262 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Modeling of photon scattering at high X-ray energies : experiment versus simulation”. Vincze L, Vekemans B, Janssens K, Adams F, Journal of analytical atomic spectrometry
T2 –, 15th International Congress on X-Ray Optics and Microanalysis (ICXOM), AUG 24-27, 1998, ANTWERP, BELGIUM 14, 529 (1999). http://doi.org/10.1039/A808040B
Abstract: The use of a detailed Monte Carlo simulation code for X-ray fluorescence spectrometers is demonstrated for calculating the outcome of X-ray scattering experiments in the incident energy range 40-80 keV. The code was validated by comparisons of experimental and simulated spectral distributions in the case of thick, homogeneous samples in which multiple photon scattering occurs with high probability. The experimental spectral distributions were collected at beamline BW5 of HASYLAB, Germany, where a highly energetic, monochromatic synchrotron beam is available. With respect to heterogeneous samples, the code was employed to evaluate the use of Rayleigh and Compton scatter signals for obtaining three dimensional information on the sample dark matrix composition.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A808040B
|
“Monte Carlo simulation of X-ray fluorescence and scattering tomography experiments”. Vincze L, Janssens K, Vekemans B, Adams F page 328 (1999).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.363736
|
“Monte Carlo simulation of X-ray fluorescence spectra: part 4: photon scattering at high X-ray energies”. Vincze L, Janssens K, Vekemans B, Adams F, Spectrochimica acta: part B : atomic spectroscopy , 1711 (1999). http://doi.org/10.1016/S0584-8547(99)00094-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00094-4
|
“The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Williams CT, Radtke M, Haller M, Knöchel A, Fresenius' journal of analytical chemistry 363, 413 (1999). http://doi.org/10.1007/S002160051212
Abstract: The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051212
|
“Optimization of tapered capillary optics for use at the microfocus beamline (ID 13) at the European Synchroton Radiation Facility”. Vincze L, Janssens K, Adams F, Rindby A, Engström P, Riekel C, Advances in X-ray analysis 41, 252 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Special issue: Proceedings of the 15th International Congress on X-ray Optics and Microanalysis”. Janssens K, Journal of analytical atomic spectroscopy 14, 357 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace-level micro-XANES by means of bending magnets radiation focused with a polycapillary lens”. Vincze L, Janssens K, Wei F, Proost K, Vekemans B, Vittiglio G, Yan Y, Falkenberg G (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace-level microanalysis of Roman glass from Khirbet Qumran, Israel”. Aerts A, Janssens K, Adams F, Journal of archaeological science 26, 883 (1999). http://doi.org/10.1006/JASC.1999.0397
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.602
DOI: 10.1006/JASC.1999.0397
|
“The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials containing heavy metals”. Kempenaers L, Vincze L, Janssens K (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|