|
“Structural features of human tooth tissues affected by high dose of external ionizing radiation after nuclear catastrophe of Chernobyl plant”. Darchuk LA, Zaverbna LV, Worobiec A, Van Grieken R, Microchemical journal 97, 282 (2011). http://doi.org/10.1016/J.MICROC.2010.09.016
Abstract: The application of micro-Raman spectroscopy is discussed for the analysis of structural features of human tooth tissues affected by high doses of external ionizing radiation (0.51.7 Gy) after the nuclear plant catastrophe in Chernobyl in 1986. The results have shown significant changes in the mineral matrix of dental enamel that lead to the decrease of tooth enamel hardness. Destruction of the collagen chain of the organic matrix has been observed for dentin and cementum.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.MICROC.2010.09.016
|
|
|
“Microneedle array-based electrochemical sensor functionalized with SWCNTs for the highly sensitive monitoring of MDMA in interstitial fluid”. Drăgan A-M, Parrilla M, Cambré, S, Domínguez-Robles J, Detamornrat U, Donnelly RF, Oprean R, Cristea C, De Wael K, Microchemical journal 193, 109257 (2023). http://doi.org/10.1016/J.MICROC.2023.109257
Abstract: Illicit drug consumption constitutes a great concern worldwide due to its increased spread and abuse, and the negative consequences exerted on society. For instance, 3,4-methylenedioxymethamphetamine (MDMA), a synthetic amphetamine-type substance, was abused by 20 million people worldwide in 2020. This psychoactive substance exerts a myriad of effects on the human body being dangerous for the consumer’s health. Besides, MDMA has been used in the treatment of some psychiatric conditions. Therefore, the development of wearable devices for MDMA sensing in biological fluids is of great importance for forensic toxicology (e.g., monitoring of patients with suspected or known MDMA consumption) as well as for therapeutic management of patients. Herein, we report the development of a wearable electrochemical platform based on a hollow microneedle (MN) array sensor for the monitoring of MDMA in the interstitial fluid by square-wave voltammetry. First, the holes of the MN array were modified with conductive pastes to devise a MN patch with a three-electrode system. Subsequently, the functionalization of the working electrode with nanomaterials enhanced MDMA detection. Thereafter, analytical parameters were evaluated exhibiting a slope of 0.05 µA µM−1 within a linear range from 1 to 50 µM and a limit of detection of 0.75 µM in artificial interstitial fluid. Importantly, critical parameters such as selectivity, piercing capability, temperature, reversibility and stability were assessed. Overall, the obtained MN sensor exhibited excellent analytical performance, making it a promising tool for MDMA tracking in interstitial fluid for individuals on probation or under therapeutic treatment.
Keywords: A1 Journal article; Pharmacology. Therapy; Nanostructured and organic optical and electronic materials (NANOrOPT); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.8
DOI: 10.1016/J.MICROC.2023.109257
|
|
|
“NanoMIPs-based electrochemical sensors for selective detection of amphetamine”. Truta F, Cruz AG, Tertis M, Zaleski C, Adamu G, Allcock NS, Suciu M, Stefan M-G, Kiss B, Piletska E, De Wael K, Piletsky SA, Cristea C, Microchemical journal 191, 108821 (2023). http://doi.org/10.1016/J.MICROC.2023.108821
Abstract: A highly sensitive and portable electrochemical sensor based on molecularly imprinted nanoparticles (nanoMIPs) was developed. NanoMIPs were computationally designed for specific recognition of amphetamine, and then synthetized using solid phase synthesis. NanoMIPs were immobilized onto screen-printed carbon electrodes using a composite film comprising chitosan, nanoMIPs, and graphene oxide.Ferrocenylmethyl methacrylate was incorporated in nanoMIPs allowing electrochemical detection. The signal recorded for the electrochemical oxidation of ferrocene has proven to be dependent on the presence of amphetamine interacting with nanMIPs. The sensor was tested successfully with street samples, with high sensitivity and satisfactory recoveries (from 100.9% to 107.6%). These results were validated with UPL-MS/MS. The present technology is suitable for forensic applications in selective determination of amphetamine in street samples.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.8
DOI: 10.1016/J.MICROC.2023.108821
|
|
|
“Novel (photo)electrochemical analysis of aqueous industrial samples containing phenols”. Neven L, Barich H, Rutten R, De Wael K, Microchemical journal 181, 107778 (2022). http://doi.org/10.1016/J.MICROC.2022.107778
Abstract: Phenols are considered as toxic pollutants and their discharge into the environment by industries is regulated by a concentration limit. As these limits are in the low mg L−1 to µg L−1-range, sensitive methods are necessary to detect these phenols. Here, aqueous industrial phenolic samples throughout a cleaning process were analyzed by two novel electrochemical sensors. Both the photoelectrochemical (PEC) sensor and the square wave voltammetric (SWV) sensor could successfully follow the decrease of the concentration of phenols along the industrial cleaning process. The discharge sample (μg L−1) could only be analyzed by the PEC sensor and not by the SWV sensor, as the phenolic concentration was close to the LOD of the latter. With HPLC-diode array detector (DAD) measurements, classical phenols such as phenol (PHOH), hydroquinone, resorcinol and o-cresol could be identified in the industrial samples, and their presence could be linked to the electrochemical responses. At last, the performance of the PEC and SWV sensors were compared with commercial colorimetric and chemical oxygen demand (COD) test kits. This comparison demonstrated the high sensitivity of the PEC sensor in the μg L−1 concentrated phenolic samples. Together with the identification of the redox peaks through HPLC-DAD analysis, the SWV sensor can be a powerful tool in the qualitative analysis of mg L−1 concentrated phenolic samples due to its speed, simplicity and absence of laborious sample pre-treatment steps.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.MICROC.2022.107778
|
|
|
“Paraformaldehyde-coated electrochemical sensor for improved on-site detection of amphetamine in street samples”. Schram J, Parrilla M, Slosse A, Van Durme F, Åberg J, Björk K, Bijvoets SM, Sap S, Heerschop MWJ, De Wael K, Microchemical journal 179, 107518 (2022). http://doi.org/10.1016/J.MICROC.2022.107518
Abstract: The increasing illicit production, distribution and abuse of amphetamine (AMP) poses a challenge for law enforcement worldwide. To effectively combat this issue, fast and portable tools for the on-site screening of suspicious samples are required. Electrochemical profile (EP)-based sensing of illicit drugs has proven to be a viable option for this purpose as it allows rapid voltammetric measurements via the use of disposable and low-cost graphite screen-printed electrodes (SPEs). In this work, a highly practical paraformaldehyde (PFA)-coated sensor, which unlocks the detectability of primary amines through derivatization, is developed for the on-site detection of AMP in seized drug samples. A potential interval was defined at the sole AMP peak (which is used for identification of the target analyte) to account for potential shifts due to fluctuations in concentration and temperature, which are relevant factors for on-site use. Importantly, it was found that AMP detection was not hindered by the presence of common diluents and adulterants such as caffeine, even when present in high amounts. When inter-drug differentiation is desired, a simultaneous second test with the same solution on an unmodified electrode is introduced to provide the required additional electrochemical information. Finally, the concept was validated by analyzing 30 seized AMP samples (reaching a sensitivity of 96.7 %) and comparing its performance to that of commercially available Raman and Fourier Transform Infrared (FTIR) devices.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.MICROC.2022.107518
|
|
|
“Validated portable device for the qualitative and quantitative electrochemical detection of MDMA ready for on-site use”. Van Echelpoel R, Parrilla M, Sleegers N, Thiruvottriyur Shanmugam S, van Nuijs ALN, Slosse A, Van Durme F, De Wael K, Microchemical journal 190, 108693 (2023). http://doi.org/10.1016/J.MICROC.2023.108693
Abstract: Identifying and quantifying 3,4-methylenedioxymethamphetamine (MDMA) on-site in suspected illicit drug samples, whether it be at recreational settings or manufacturing sites, is a major challenge for law enforcement agencies (LEAs). Various analytical techniques exist to fulfil this goal, e.g. colourimetry and portable spectroscopic techniques, each having its specific limitations (e.g. low accuracy, fluorescence, no quantification) and strengths (e.g. fast, easy to use). In this work, for the first time, an electrochemical MDMA sensor is presented to become a detection tool that can realistically be used on-site. More specifically, the use of a single buffer solution and an unmodified screen-printed electrode, along with the integration of a data analysis algorithm and mobile application permits the straightforward on-site identification and quantification of MDMA in suspicious samples. Multiple studies investigating different parameters, including pH, concentration, reproducibility, temperature and binary mixture analyses, were executed. To fully understand all the occurring redox processes, liquid chromatography coupled with high-resolution mass spectrometry analysis of partially electrolyzed MDMA samples was performed unravelling oxidation of the methylenedioxy group. Validation of the methodology was executed on 15 MDMA street samples analysed by gas chromatography coupled with mass spectrometry and compared with the performance of a commercial portable Raman and Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR) device. The novel methodology outperformed the spectroscopic techniques, correctly identifying all 15 street samples. Additionally, the electrochemical sensor predicted the purity of the tablets with a mean absolute error of 2.3%. Overall, this new, electrochemical detection strategy provides LEAs the rapid, low-cost, on-site detection and quantification of MDMA in suspicious samples, without requiring specialized training.
Keywords: A1 Journal article; Engineering sciences. Technology; Toxicological Centre; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.8
DOI: 10.1016/J.MICROC.2023.108693
|
|
|
“Darkening of lead white in old master drawings and historic prints : a multi-analytical investigation”. Pastorelli G, Miranda ASO, Avranovich Clerici E, d'Imporzano P, Hansen BV, Janssens K, Davies GR, Borring N, Microchemical journal 199, 109912 (2024). http://doi.org/10.1016/J.MICROC.2024.109912
Abstract: Old master drawings and historic prints often feature white highlights, which are typically painted using lead white, one of the most widely used historical white pigments. However, it has been observed that many of these highlights discolour over time, becoming dark brown or black due to unclear degradation processes. This phenomenon not only misrepresents the original artefacts, threatening their suitability for public display, but also diminishes their longevity. To ensure their preservation, it is essential to determine why some lead white highlights in these museum objects retain their light tones while others are prone to darkening. The objective of this study was to identify the relationships between the composition, provenance, and production methods of lead white pigments, and their role in the discolouration observed on drawings, lithographs and early photographs. Selected samples and artefacts were examined using a range of analytical techniques, namely X-ray fluorescence spectroscopy (XRF), X-ray powder diffraction (XRPD), and lead isotope analysis. While XRF analyses confirmed the presence of lead as the primary element in the majority of the highlights, XRPD measurements identified a variety of lead compounds such as the carbonates cerussite and hydrocerussite alongside galena-a black crystalline sulfide-and lead sulfates. Additionally, isotope analyses classified the lead raw materials into five main groups. Through these measurements, the examined lead white pigments were categorised based on their compositional properties in relation to the raw materials used, as well as their geographical and temporal origin. A significant finding is that lead white pigments from different production periods, spanning from older to more modern, may be characterised by varying proneness to discolouration irrespective of their provenance.
Keywords: A1 Journal article; Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 4.8
DOI: 10.1016/J.MICROC.2024.109912
|
|
|
“Synchrotron radiation induced X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Aerts A, Adams F, Jones KW, Knöchel A, Microchimica acta
T2 –, 4th Workshop of the European-Microanalysis-Society on Modern, Developments and Applications in Microbeam Analysis, MAY, 1995, ST MALO, FRANCE , 87 (1996)
Abstract: mu-XRF is the microscopic equivalent of the well-established multielement analytical technique. In this paper, after comparing the interaction of X-ray photons, electrons and protons with matter and an introduction to synchrotron rings and microfocussing of X-rays, the instrumentation for mu-XRF is discussed, both for laboratory source and synchrotron based setups and the analytical characteristics of mu-XRF are contrasted to that of other microanalytical techniques, Also, this issue of quantification of mu-XRF data is addressed; the applicability of the method in archeological and geological analysis is illustrated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“A mass spectrometric study of the dissolution behavior of sanidine”. Adriaens A, Van 't dack L, Adams F, Gijbels R, Microchimica acta 120, 139 (1995). http://doi.org/10.1007/BF01244427
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.741
Times cited: 1
DOI: 10.1007/BF01244427
|
|
|
“Model-based quantification of EELS: is standardless quantification possible?”.Verbeeck J, Bertoni G, Microchimica acta 161, 439 (2008). http://doi.org/10.1007/s00604-008-0948-7
Abstract: Electron energy loss spectroscopy (EELS) is an ideal tool to obtain chemical information from nanoscale volumes. Quantification of the experimental spectra however has prevented for a long time access to the available information in a reliable and reproducible way. We present recent advances in model-based quantification of EELS spectra and show that we obtain the best possible precision for a given dataset, as well as remarkably good accuracies when applied to three different materials. The results are shown to be far superior over conventional quantification techniques and could hold a promise for standardless quantification of EELS spectra.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 4.58
Times cited: 5
DOI: 10.1007/s00604-008-0948-7
|
|
|
“Modern developments and applications in microbeam analysis: proceedings of the 10th Workshop of the European Microbeam Analysis Society (EMAS), Antwerp, Belgium, May 6-10, 2007”. Van 't dack L, Gijbels R, Walker CT, Microchimica acta 161, 285 (2008). http://doi.org/10.1007/s00604-008-0958-5
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.58
Times cited: 1
DOI: 10.1007/s00604-008-0958-5
|
|
|
“Observation of Sb203 nanocrystals in SiO2 after Sb ion implantation”. Ignatova VA, Lebedev OI, Wätjen U, van Vaeck L, van Landuyt J, Gijbels R, Adams F, Microchimica acta 139, 77 (2002). http://doi.org/10.1007/s006040200043
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.58
Times cited: 3
DOI: 10.1007/s006040200043
|
|
|
“Complementary analysis of historical glass by scanning electron microscopy with energy dispersive X-ray spectroscopy and laser ablation inductiveley coupled plasma mass spectrometry”. Wagner B, Nowak A, Bulska E, Kunicki-Goldfinger J, Schalm O, Janssens K, schalm, Microchimica acta 162, 415 (2008). http://doi.org/10.1007/S00604-007-0835-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 28
DOI: 10.1007/S00604-007-0835-7
|
|
|
“Multianalytical study of patina formed on archaeological metal objects from Bliesbruck-Reinheim”. Wadsak M, Constantinides I, Vittiglio G, Adriaens A, Janssens K, Schreiner M, Adams FC, Brunella P, Wuttmann M, Microchimica acta 133, 159 (2000). http://doi.org/10.1007/S006040070086
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.58
DOI: 10.1007/S006040070086
|
|
|
“Application of EDXRF and thin window EPMA for the investigation of the influence of hot air heating on the generation and deposition of particulate matter”. Spolnik Z, Bencs L, Worobiec A, Kontozova V, Van Grieken R, Microchimica acta 149, 79 (2005). http://doi.org/10.1007/S00604-004-0299-Y
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S00604-004-0299-Y
|
|
|
“Application of EPMA and XRF for the investigation of particulate pollutants in the field of cultural heritage”. Kontozova-Deutsch V, Deutsch F, Godoi RHM, Spolnik Z, Wei W, Van Grieken R, Microchimica acta 161, 465 (2008). http://doi.org/10.1007/S00604-007-0917-6
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-007-0917-6
|
|
|
“Application of thin-window EPMA to environmental problems in Hungary”. Osán J, Kurunczi S, Török S, Worobiec A, Van Grieken R, Microchimica acta 139, 111 (2002). http://doi.org/10.1007/S006040200048
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040200048
|
|
|
“Applying digital image processing to SEM-EDX and BSE images to determine and quantify porosity and salts with depth in porous media”. Cardell C, Yebra A, Van Grieken RE, Microchimica acta 140, 9 (2002). http://doi.org/10.1007/S006040200063
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040200063
|
|
|
“Assessing the size-dependent chemical speciation of soil particles using electron probe X-ray microanalysis”. Semenov MY, Spolnik Z, Van Grieken R, Microchimica acta 157, 121 (2007). http://doi.org/10.1007/S00604-006-0637-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-006-0637-3
|
|
|
“Assessment of local analysis by Fourier transform laser microprobe mass spectrometry with external ion source”. van Roy W, Struyf H, Kennis P, Van Vaeck L, Van Grieken R, Andrle C, Microchimica acta 120, 121 (1995). http://doi.org/10.1007/BF01244426
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01244426
|
|
|
“Characterisation of sugar cane combustion particles in the Araraquara region, Southeast Brazil”. Godoi RHM, Godoi AFL, Worobiec A, Andrade SJ, de Hoog J, Santiago-Silva MR, Van Grieken R, Microchimica acta 145, 53 (2004). http://doi.org/10.1007/S00604-003-0126-X
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-003-0126-X
|
|
|
“Chemical characterization of airborne particles in St. Martinus Cathedral in Weert, The Netherlands”. Spolnik Z, Worobiec A, Injuk J, Neilen D, Schellen H, Van Grieken R, Microchimica acta 145, 223 (2004). http://doi.org/10.1007/S00604-003-0158-2
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-003-0158-2
|
|
|
“Computer aided processing of laser microprobe mass spectra”. Wouters L, Michaud D, Van Grieken R, Microchimica acta 110, 31 (1993). http://doi.org/10.1007/BF01243982
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01243982
|
|
|
“Detection limits of grazing-exit EPMA for particle analysis”. Tsuji K, Spolnik Z, Wagatsuma K, Nullens R, Van Grieken RE, Microchimica acta 132, 357 (2000). http://doi.org/10.1007/S006040050080
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040050080
|
|
|
“Determination of total selenium content in cereals and bakery products by flow injection hydride generation graphite furnace atomic absorption spectrometry applying in-situ trapping on iridium-treated graphite platforms”. Ajtony Z, Szoboszlai N, Bella Z, Bolla S, Szakál P, Bencs L, Microchimica acta 150, 1 (2005). http://doi.org/10.1007/S00604-005-0330-Y
Abstract: A flow injection hydride generation graphite furnace atomic absorption spectrometric (FI-HG-GFAAS) method was applied to the determination of Se in Se-doped and undoped cereals and bakery products. For the purpose of doping, the soils used for the cultivation of the cereals were dosed with Se- doped foliar fertilizers. The samples were dissolved in a mixture of HNO(3) and H(2)O(2) solutions using micro-waveassisted digestion. The decomposition of H(2)Se generated from the sample solutions and the trapping of elemental Se were performed at a temperature of 300 degrees C on an Ir-pretreated integrated graphite platform of a transversally heated graphite atomizer(THGA). For release of the trapped Se within a fairly short atomization time (5s), an atomization temperature of 2200 degrees C was observed to be optimal. The overall efficiency of hydride generation, transport and trapping was similar to 86%. The upper limit of the linear dynamic range of calibration was 10 mu gL(-1), which corresponds to 0.5 mu g g(-1) for solid samples. Recovery of the samples spiked with Se(VI) solutions was found to be 93 +/- 6% on average. The relative standard deviation of the determinations was less than 8%. The limit of detection was found to be 0.06 mu gL(-1), corresponding to 3 ng g(-1) for solid samples. The accuracy of the method was verified with the use of IAEA-155 ( whey powder) certified reference material. End-capped THGA tubes resulted in an extension of the linear calibration range compared to that of standard THGAs. The Se content in bakery products made of undoped cereals ranged from 7.7 to 68 ng g(-1) ( wet weight) in 18 samples, whereas the Se content of the corresponding cereals was found to be below 100 ng g(-1) ( wet weight). The Se level of cereals grown on soils treated with Se- doped fertilizers ranged from 128 to 1046 ng g(-1) ( wet weight), and it depended linearly on the Se concentration of the corresponding foliar fertilizer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-005-0330-Y
|
|
|
“Electron probe X-ray microanalysis for the assessment of homogeneity of candidate reference materials at the nanogram level”. Hoornaert S, Treiger B, Valkovic V, Van Grieken R, Microchimica acta 128, 207 (1998). http://doi.org/10.1007/BF01243051
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01243051
|
|
|
“Extraction of environmental information from large aerosol data sets through combined application of cluster and factor analysis”. de Bock LA, Treiger B, van der Auwera L, Van Grieken RE, Microchimica acta 128, 191 (1998). http://doi.org/10.1007/BF01243049
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01243049
|
|
|
“Flexible and integrated dual carbon sensor for multiplexed detection of nonylphenol and paroxetine in tap water samples”. Gomes NO, Mendonça CD, Machado SAS, Oliveira ON Jr, Raymundo-Pereira PA, Microchimica Acta 188, 359 (2021). http://doi.org/10.1007/S00604-021-05024-4
Abstract: Multiplex detection of emerging pollutants is essential to improve quality control of water treatment plants, which requires portable systems capable of real-time monitoring. In this paper we describe a flexible, dual electrochemical sensing device that detects nonylphenol and paroxetine in tap water samples. The platform contains two voltammetric sensors, with different working electrodes that were either pretreated or functionalized. Each working electrode was judiciously tailored to cover the concentration range of interest for nonylphenol and paroxetine, and square wave voltammetry was used for detection. An electrochemical pretreatment with sulfuric acid on the printed electrode enabled a selective detection of nonylphenol in 1.0-10 x 10(-6) mol L-1 range with a limit of detection of 8.0 x 10(-7) mol L-1. Paroxetine was detected in the same range with a limit of detection of 6.7 x 10(-7) mol L-1 using the printed electrode coated with a layer of carbon spherical shells. Simultaneous detection of the two analytes was achieved in tap water samples within 1 min, with no fouling and no interference effects. The long-term monitoring capability of the dual sensor was demonstrated in phosphate buffer for 45 days. This performance is statistically equivalent to that of high-performance liquid chromatography (HPLC) for water analysis. The dual-sensor platform is generic and may be extended to other water pollutants and clinical biomarkers in real-time monitoring of the environment and health conditions.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.58
DOI: 10.1007/S00604-021-05024-4
|
|
|
“Investigation of gaseous and particulate air pollutants at the Basilica Saint-Urbain in Troyes, related to the preservation of the medieval stained glass windows”. Kontozova-Deutsch V, Godoi RHM, Worobiec A, Spolnik Z, Krata A, Deutsch F, Van Grieken R, Microchimica acta 162, 425 (2008). http://doi.org/10.1007/S00604-007-0930-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S00604-007-0930-9
|
|
|
“Light element analysis of individual microparticles using thin-window EPMA”. Osán J, Szalóki I, Ro C-U, Van Grieken R, Microchimica acta 132, 349 (2000). http://doi.org/10.1007/S006040050079
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040050079
|
|