“Accurate evaluation of \mu-PIXE and \mu-XRF spectral data through iterative least squares fitting”. Janssens K, Vekemans B, Adams F, van Espen P, Mutsaers P, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms
T2 –, 7th International Conference on Particle Induced X-ray Emission and Its Analytical Applications, MAY 26-30, 1995, Abano Terme, Italy 109, 179 (1996). http://doi.org/10.1016/0168-583X(95)01211-7
Abstract: The integration of the nonlinear least squares X-ray spectrum evaluation progam AXIL. into a mu-PIXE and a mu-XRF setup is discussed. The use of the software when procesing data sets derived from biological and geological samples is described.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0168-583X(95)01211-7
|
“A laboratory mu-XRF spectrometer employing capillary optics”. Janssens K, Vekemans B, Rindby A, Vincze L, Adams F, , 159 (1995)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Estimation of relative Fe2+ and Fe3+ contents of original manuscript fragments by means of μ-XANES and Mössbauer spectrometry”. Janssens K, Vekemans B, Rouchon-Quillet V (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“A micro XRF spectrometer based on rotating anode generator and capillary optics”. Janssens K, Vekemans B, Vincze L, Adams F, Rindby A, Spectrochimica acta: part B : atomic spectroscopy 51, 1661 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Synchrotron radiation-induced X-ray microanalysis”. Janssens K, Vincze L, Adams F, Jones KW, Analytica chimica acta 283, 98 (1993). http://doi.org/10.1016/0003-2670(93)85213-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(93)85213-4
|
“Microscopic synchroton radiation induced X-ray fluorescence analysis”. Janssens K, Vincze L, Aerts A, Vekemans B, Adams F, Jones K, Knöchel A, Mikrochimica acta: supplementum , 87 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Microscopic X-ray fluorescence analysis”. Janssens K, Vincze L, Rubio J, Bernasconi G, Adams F, Journal of analytical atomic spectrometry 9, 151 (1994). http://doi.org/10.1039/JA9940900151
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/JA9940900151
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
“Evaluation and calibration of micro-XRF data”. Janssens K, Vincze L, Vekemans B page 155 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“The use of lead-glass capillaries for microfocusing of highly energetic (0-60 KeV) synchrotron radiation”. Janssens K, Vincze L, Vekemans B, Adams F, Haller M, Knöchel A, Journal of analytical atomic spectrometry 13, 339 (1998). http://doi.org/10.1039/A707700I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A707700I
|
“Synchrotron radiation induced X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Aerts A, Adams F, Jones KW, Knöchel A, Microchimica acta
T2 –, 4th Workshop of the European-Microanalysis-Society on Modern, Developments and Applications in Microbeam Analysis, MAY, 1995, ST MALO, FRANCE , 87 (1996)
Abstract: mu-XRF is the microscopic equivalent of the well-established multielement analytical technique. In this paper, after comparing the interaction of X-ray photons, electrons and protons with matter and an introduction to synchrotron rings and microfocussing of X-rays, the instrumentation for mu-XRF is discussed, both for laboratory source and synchrotron based setups and the analytical characteristics of mu-XRF are contrasted to that of other microanalytical techniques, Also, this issue of quantification of mu-XRF data is addressed; the applicability of the method in archeological and geological analysis is illustrated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Williams CT, Radtke M, Haller M, Knöchel A, Fresenius' journal of analytical chemistry 363, 413 (1999). http://doi.org/10.1007/S002160051212
Abstract: The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051212
|
“Feasibility of (trace-level) micro-XANES at Beamline L”. Janssens K, Vincze L, Wei F, Proost K, Vekemans B, Vittiglio G, Yan Y, Falkenberg G (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Use of microscopic XRF for non-destructive analysis in art an archaeometry”. Janssens K, Vittiglio G, Deraedt I, Aerts A, Vekemans B, Vincze L, Wei F, de Ryck I, Schalm O, Adams F, Rindby A, Knöchel A, Simionovici AS, Snigirev A, X-ray spectrometry 29, 73 (2000). http://doi.org/10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
|
“Comparison of synchrotron X-ray microanalysis with electron and proton microscopy for individual particle analysis”. Janssens KH, Adams FC, van Langevelde F, Vis RD, Jones KW, Rivers M, Sutton S, Advances in X-ray analysis 35, 1265 (1992)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Composition of 15-17th century archaeological glass vessels excavated in Antwerp, Belgium”. Janssens KH, Deraedt I, Schalm O, Veeckman J, Mikrochimica acta: supplementum 15, 253 (1998)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Janssens KHA, Adams FCV, Rindby A (2000) Microscopic X-ray fluorescence analysis. 419 p
Keywords: MA1 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Effect of strain on the magnetoexciton ground state in InP/GaxIn1-xP quantum disks”. Janssens KL, Partoens B, Peeters FM, Physical review : B : condensed matter and materials physics 67, 235325 (2003). http://doi.org/10.1103/PhysRevB.67.235325
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 23
DOI: 10.1103/PhysRevB.67.235325
|
“Influence of strain on the magneto-exciton in single and coupled InP/GaInP quantum disks”. Janssens KL, Partoens B, Peeters FM, Physica. E: Low-dimensional systems and nanostructures 21, 349 (2004). http://doi.org/10.1016/j.physe.2003.11.269
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
DOI: 10.1016/j.physe.2003.11.269
|
“Magneto-exciton in single and coupled type II quantum dots”. Janssens KL, Partoens B, Peeters FM, Physica status solidi: A: applied research 190, 571 (2002). http://doi.org/10.1002/1521-396X(200204)190:2<571::AID-PSSA571>3.0.CO;2-K
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
DOI: 10.1002/1521-396X(200204)190:2<571::AID-PSSA571>3.0.CO;2-K
|
“Magneto-excitons in planar type II quantum dots”. Janssens KL, Partoens B, Peeters FM, Physical review : B : condensed matter and materials physics 64 (2001). http://doi.org/10.1103/PhysRevB.64.155324
Abstract: We study an exciton in a type-II quantum dot, where the electron is confined in the dot, but the hole is located in the barrier material. The exciton properties are studied as a function of a perpendicular magnetic field using a Hartree-Fock mesh calculation. Our model system consists of a planar quantum disk. Angular momentum (l) transitions are predicted with increasing magnetic field. We, also study the transition from a type-I to a type-H quantum dot which is induced by changing the confinement potential of the hole. For sufficiently large magnetic fields a reentrant behavior is found from l(h) = 0 to l(h) not equal 0 and back to l(h) = 0, which results in a transition from type II to type I.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 56
DOI: 10.1103/PhysRevB.64.155324
|
“Magnetoexciton in vertically coupled InP/GaInP quantum disks: effect of strain on the exciton ground state”. Janssens KL, Partoens B, Peeters FM, Physical review : B : condensed matter and materials physics 69, 235320 (2004). http://doi.org/10.1103/PhysRevB.69.235320
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 9
DOI: 10.1103/PhysRevB.69.235320
|
“Single and coupled type II quantum dots in magnetic and electric fields”. Janssens KL, Partoens B, Peeters FM, Physicalia magazine 24, 211 (2002)
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
|
“Single and vertically coupled type-II quantum dots in a perpendicular magnetic field: exciton ground-state properties”. Janssens KL, Partoens B, Peeters FM, Physical review : B : condensed matter and materials physics 66, 075314 (2002). http://doi.org/10.1103/PhysRevB.66.075314
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 38
DOI: 10.1103/PhysRevB.66.075314
|
“Stark shift in single and vertically coupled type-I and type-II quantum dots”. Janssens KL, Partoens B, Peeters FM, Physical review : B : condensed matter and materials physics 65, 233301 (2002). http://doi.org/10.1103/PhysRevB.65.233301
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 43
DOI: 10.1103/PhysRevB.65.233301
|
“Type II quantum dots in magnetic fields: excitonic behaviour”. Janssens KL, Partoens B, Peeters FM, Microelectronics journal 34, 347 (2003). http://doi.org/10.1016/S0026-2692(03)00023-5
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 1.163
Times cited: 1
DOI: 10.1016/S0026-2692(03)00023-5
|
“Monte-Carlo simulation of the coherent backscattering of electrons in a ballistic system”. Janssens KL, Peeters FM, Superlattices and microstructures 25, 615 (1999). http://doi.org/10.1006/spmi.1999.0697
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.123
DOI: 10.1006/spmi.1999.0697
|
“Magnetic field dependence of the exciton energy in a quantum disk”. Janssens KL, Peeters FM, Schweigert VA, Physical review : B : condensed matter and materials physics 63, 205311 (2001). http://doi.org/10.1103/PhysRevB.63.205311
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.836
Times cited: 81
DOI: 10.1103/PhysRevB.63.205311
|
“Magnetic field dependence of the properties of excitons confined in a quantum disk”. Janssens KL, Peeters FM, Schweigert VA, Physica status solidi: B: basic research 224, 763 (2001). http://doi.org/10.1002/(SICI)1521-3951(200104)224:3<763::AID-PSSB763>3.0.CO;2-9
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 1.674
Times cited: 1
DOI: 10.1002/(SICI)1521-3951(200104)224:3<763::AID-PSSB763>3.0.CO;2-9
|
“Magnetic field dependence of the xciton energy in type I and type II quantum disks”. Janssens KL, Peeters FM, Schweigert VA, Partoens B, Physica: B : condensed matter 298, 277 (2001). http://doi.org/10.1016/S0921-4526(01)00316-7
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 1.386
Times cited: 4
DOI: 10.1016/S0921-4526(01)00316-7
|