|
Records |
Links |
|
Author |
Van Dyck, P.M.; Van Grieken, R.E. |
|
|
Title |
Absorption correction via scattered radiation in energy-dispersive X-ray fluorescence analysis for samples of variable composition and thickness |
Type |
A1 Journal article |
|
Year |
1980 |
Publication |
Analytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
52 |
Issue |
12 |
Pages |
1859-1864 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1980KJ65700021 |
Publication Date |
2005-03-08 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116516 |
Serial |
7410 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanderborght, B.M.; Van Grieken, R.E. |
|
|
Title |
Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon |
Type |
A1 Journal article |
|
Year |
1980 |
Publication |
Talanta : the international journal of pure and applied analytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
27 |
Issue |
5 |
Pages |
417-422 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1980JR07800006 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0039-9140; 1873-3573 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116557 |
Serial |
8746 |
|
Permanent link to this record |
|
|
|
|
Author |
Duarte, P.J.; Mabesoone, J.M.; Van Grieken, R.; Delgado, A. |
|
|
Title |
Aspectos geoquimicos da Formaçao Longa (Devoniano Superior do Piaui-Maranhao) |
Type |
A3 Journal article |
|
Year |
1979 |
Publication |
Estudos geologicos |
Abbreviated Journal |
|
|
|
Volume |
3 |
Issue |
3 |
Pages |
79-96 |
|
|
Keywords |
A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116689 |
Serial |
7494 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanderstappen, M.G.; Van Grieken, R.E. |
|
|
Title |
Co-crystallization with 1-(2-pyridylazo)-2-naphthol, and X-ray fluorescence, for trace metal analysis of water |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
Talanta : the international journal of pure and applied analytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
25 |
Issue |
11/12 |
Pages |
653-658 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Adding 20mg of 1-(2-pyridylazo)-2-naphthol (PAN) to a water sample at 70°, and filtering off the precipitate after cooling, gives efficient preconcentration prior to X-ray fluorescence analysis of water. Up to the capacity of about 100 μeq of PAN used, the trace metal recoveries are around 90% or higher for Cr3+, Mn2+, Ni2+, Cu2+, Zn2+, Hg2+ and Eu3+, and above 70% for many other ions. The recovery yields usually do not vary critically with pH in the neutral pH-range, and are practically independent of the sample salinity, sample volume and trace-metal concentration. Enrichment factors as high as 2 × 105 can be achieved. Counting statistics would then allow detection limits of 0.03 ppM. The blank levels in commercial PAN, however, lead to typical detection limits of about 1 ppm. The coefficient of variation is typically in the 510% range at the 10-ppM level. The accuracy and applicability of the procedure are illustrated by comparative analyses on samples of synthetic solutions, river and drinking water. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1978GG18200005 |
Publication Date |
2002-07-25 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0039-9140; 1873-3573 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116556 |
Serial |
7675 |
|
Permanent link to this record |
|
|
|
|
Author |
Martin, J.-M.; Thomas, A.J.; Van Grieken, R.E. |
|
|
Title |
Trace element composition of Zaire suspended sediments |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
Netherlands journal of sea research |
Abbreviated Journal |
|
|
|
Volume |
12 |
Issue |
3/4 |
Pages |
414-420 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2003-08-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0077-7579; 1873-1406 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116609 |
Serial |
8688 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanderborght, B.M.; Van Grieken, R.E. |
|
|
Title |
Trace metal analysis of water containing humic substances by X-ray fluorescence |
Type |
A1 Journal article |
|
Year |
1978 |
Publication |
International journal of environmental analytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
5 |
Issue |
3 |
Pages |
221-237 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1978FR88000005 |
Publication Date |
2007-07-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0306-7319 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116570 |
Serial |
8692 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R.E.; Bresseleers, C.M.; Vanderborght, B.M. |
|
|
Title |
Chelex-100 ion-exchange filter membranes for preconcentration in x-ray-fluorescence analysis of water |
Type |
A1 Journal article |
|
Year |
1977 |
Publication |
Analytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
49 |
Issue |
9 |
Pages |
1326-1331 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1977DP25600011 |
Publication Date |
2005-03-08 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:113632 |
Serial |
7639 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanderborght, B.M.; Van Grieken, R.E. |
|
|
Title |
Enrichment of trace metals in water by adsorption on activated carbon |
Type |
A1 Journal article |
|
Year |
1977 |
Publication |
Analytical chemistry |
Abbreviated Journal |
|
|
|
Volume |
49 |
Issue |
2 |
Pages |
311-316 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700; 5206-882x |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116513 |
Serial |
7923 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R.; Bresseleers, K.; Smits, J.; Vanderborght, B.; Vanderstappen, M. |
|
|
Title |
Enrichment procedures for water analysis by X-ray energy spectrometry |
Type |
P3 Proceeding |
|
Year |
1976 |
Publication |
|
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
|
|
|
Keywords |
P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:113634 |
Serial |
7924 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanderstappen, M.; Van Grieken, R. |
|
|
Title |
Trace metal analysis of sediments and particulate matter in sea water by energy-dispersive X-ray fluorescence |
Type |
A3 Journal article |
|
Year |
1976 |
Publication |
Fresenius' Zeitschrift für analytische Chemie |
Abbreviated Journal |
|
|
|
Volume |
282 |
Issue |
1 |
Pages |
25-30 |
|
|
Keywords |
A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The capability of energy-dispersive X-ray fluorescence was investigated for fast and simple chemical analysis of trace elements in sediments and particulate matter in sea water. Nuclepore 0.4 μm pore-size membranes are recommended as optimal filters for a straightforward collection of suspended material. The collection of suspended trace metals by filtration seemed to give a sufficiently homogeneous filter load (s% <2.5). Data are presented on the concentrations of K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Rb and Sr with a fair precision (s% < 5.6) and accuracy. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2004-11-12 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0016-1152 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116637 |
Serial |
8691 |
|
Permanent link to this record |