|
“Soil analysis by thin-film energy-dispersive X-ray fluorescence”. Van Grieken R, Van 't dack L, Costa Dantas C, Da Silveira Dantas H, Analytica chimica acta 108, 93 (1979). http://doi.org/10.1016/S0003-2670(01)93044-2
Abstract: Energy-dispersive x-ray fluorescence is advantageous for trace analysis of soils present as thin films. A target thickness of about 2 mg cm-2 provides a compromise between optimal sensitivity and minimal absorption effect or optimal accuracy. Sample preparation involves only suspending the finely ground soil in water and drying this suspension on a thin mylar foil glued on a ring that fits into the x.r.f. spectrometer. The effective sample weight present in the exciting beam area is computed from the scatter peaks, a method that cancels out target heterogeneity problems. High accuracy is demonstrated for many elements in reference soil and rock materials; a precision around 5% and a detection limit around 10 ppm can be achieved. As an illustration, results for 16 trace elements and preliminary interpretation are given for a series of pedologically important soil samples from Brasil.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93044-2
|
|
|
“Spark-source mass-spectrometric sensitivity factors for elements in a graphite matrix”. Vanderborght B, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 26, 461 (1979). http://doi.org/10.1016/0039-9140(79)80111-3
Abstract: Relative sensitivity factors for determination of 41 elements by spark-source mass-spectrometry have been measured. The samples were pressed into graphite electrodes and ionized with a radiofrequency spark. The mass spectra were recorded on a photoplate and the resulting data processed by a computer. Indium was used as standard and the relative sensitivity factors for both singly- and doubly-charged ions were determined with reference to the singly-charged indium ion, with an overall error of 30%. The mean analysis precision was 16%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(79)80111-3
|
|
|
“Trace analysis of estuarine brown algae by energy-dispersive X-ray fluorescence”. Sauter L, Van der Ben D, Van Grieken R, X-ray spectrometry 8, 159 (1979). http://doi.org/10.1002/XRS.1300080405
Abstract: Brown algae, which are good indicators for estuarine metal pollution, can advantageously be analysed by energy-dispersive X-ray fluorescence. The use of thin film samples and samples of intermediate thickness has several advantages over the conventional thick pellet procedure. A quite homogeneous thin target is prepared by suspending 15 mg of dried and ground seaweed powder in bi-distilled water and evaporating the slurry on a 10 cm2 Mylar foil held in a Teflon ring. The effective sample weight in the beam is calculated by a procedure based on the scatter peaks in the spectrum. Sensitivities are typically in the 215 ppm range. The coefficient of variation per analysis averaged over ten elements amounts to 10%. The natural concentration variation in seaweed specimens at one location is 13%. Samples from locations in the more polluted western Scheldt estuary yield significantly higher values for several elements, relative to the eastern Scheldt sites. Possible trace element variations between the top and base of plants, and between different seaweed specimens and sampling seasons, are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300080405
|
|
|
“Absorption correction via scattered radiation in energy-dispersive X-ray fluorescence analysis for samples of variable composition and thickness”. Van Dyck PM, Van Grieken RE, Analytical chemistry 52, 1859 (1980). http://doi.org/10.1021/AC50062A020
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50062A020
|
|
|
“Automatic absorption correction in x-ray fluorescence analysis of intermediate thickness samples using a dual external reference signal”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 9, 70 (1980). http://doi.org/10.1002/XRS.1300090209
Abstract: A method has been investigated which allows calculations from the X-ray fluorescence spectra of the absorption coefficients at any energy for any sample, without any additional measurement. Use is made of the ratio of the characteristic X-ray signals from a Zr wire positioned in front of the sample and from a Pd foil placed behind the sample, both in a fixed geometry. From the experimentally measured absorption coefficient at the Pd L energy (2.9 keV), the coefficients for higher energies are calculated. By the use of an iterative computer routine in which corrections for the enhancement of the Pd foil by the sample are also included, an accuracy of 2% or better on the absorption coefficient determination can be reached for homogenous samples in one measurement. Grain-size and heterogeneity effects induce inaccuracies on the absorption coefficient determinations which might well reach 20% for particulate samples like intermediate thickness deposits of geological materials. This approach thus has the same limitations as the classical transmission method for such heterogeneous samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300090209
|
|
|
“Characterization of a 2,2'-diaminodiethylamine-cellulose filter toward metal cation extraction”. Smits JA, Van Grieken RE, Analytical chemistry 52, 1479 (1980). http://doi.org/10.1021/AC50059A022
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50059A022
|
|
|
“Radiometric diameter concept and exact intensities for spherical particles in x-ray fluorescence analysis”. Markowicz A, Van Dyck P, Van Grieken R, X-ray spectrometry 9, 52 (1980). http://doi.org/10.1002/XRS.1300090205
Abstract: In X-ray fluorescence analysis the concept of radiometric diameter, d, is often introduced in considerations of the fluorescent intensity from a particulate sample. It represents the mean geometric path of the X-rays through one particle and is usually simply taken to be equal to the volume-to-area ratio of the particle. The effective radiometric path is, however, itself dependent on geometry and absorption effects. Rigorous calculations of the fluorescent intensity from a particle in the π and π/2 geometries were carried out to evaluate the errors involved. It appears that, for π geometry, the discrepancy between these exact results and the intensity calculated via the use of d does not exceed 5.2%. For the π/2 geometry, the errors are much larger and can amount to 50% in realistic cases of X-ray fluorescence analysis. These conclusions are also applicable to monolayers. The effective radiometric diameter approaches d only when absorption effects become negligible, but is smaller in other cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300090205
|
|
|
“Sample contamination from a commercial grinding unit”. Van Grieken R, Van de Velde R, Robberecht H, Analytica chimica acta 118, 137 (1980). http://doi.org/10.1016/S0003-2670(01)93724-9
Abstract: The contamination of ground samples by a commercially available Lovibond McCrone Micronizing Mill is discussed. Tracer and weighing experiments showed that abrasion of corundum grinding elements was important, introducing 620 mg of abrasion products per minute of wet grinding. Agate grinding elements were abraded at ⩽6 mg min-1. The abrasion products and grinding elements were analyzed by x-ray fluorescence, spark-source mass spectrometry and neutron activation analysis. Contamination in trace element analysis of geological materials is likely to be negligible for agate grinding elements and, except for a few transition metals, also for corundum grinding elements. Contamination of typical biological samples is significant for a few elements even when agate elements are used, and is absolutely prohibitive for trace analysis when corundum elements are used.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93724-9
|
|
|
“Sub-part-per-billion determination of total dissolved selenium and selenite in environmental waters by X-ray fluorescence spectrometry”. Robberecht HJ, Van Grieken RE, Analytical chemistry 52, 449 (1980). http://doi.org/10.1021/AC50053A017
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50053A017
|
|
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
|
|
“Hard-spere model for hydrodynamic chromatography systems”. Tavernier SMF, Nies E, Gijbels R, Analytical proceedings 18, 31 (1981). http://doi.org/10.1039/AP9811800031
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1039/AP9811800031
|
|
|
“Analise de solos por meio de fluorescencia de raios-X nao-dispersiva”. Costa Dantas C, Da Silveira Dantas H, Van 't dack L, Van Grieken R, Química nova 4, 110 (1981)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Chelating 2,2′-diaminodiethylamine cellulose filters and X-ray fluorescence for preconcentration and trace analysis of natural waters”. Smits J, Van Grieken R, International journal of environmental analytical chemistry 9, 81 (1981). http://doi.org/10.1080/03067318108071902
Abstract: The 2,2′-diaminodiethylamine (DEN) functional group can be expected to have ideal properties for the chelation of transition metals and their collection from aqueous solutions, independent of the alkali and alkaline earth ions concentration. Introducing DEN into cellulose filters allows straightforward preconcentration of trace cations by a simple filtration step, and the DEN-filter constitutes a suitable target for X-ray fluorescence (XRF) analysis. The linearity between the XRF-response on the loaded DEN-filter and the trace cation concentration in the solution appears excellent, up to a total filter capacity of ca. 3 μeq.cm−2. The detection limits are around 0.5 μg. l−1 in most practical cases. Accuracy and precision are around 10%. The applicability of the proposed procedure is illustrated on a comparative basis by XRF-analysis of drinking water and surface water, after preconcentration by DEN-filtration and by alternative procedures.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318108071902
|
|
|
“Enrichment of trace anions from water with 2,2'-diaminodiethylamine cellulose filters”. Smits J, Van Grieken R, Analytica chimica acta 123, 9 (1981). http://doi.org/10.1016/S0003-2670(01)83152-4
Abstract: Cellulose filters with immobilized 2,2'-diaminodiethylamine (DEN) functional groups are studied for trace anion preconcentration from aqueous solution, with subsequent x-ray fluorescence measurements. For most oxoanions with a central metal atom, nearly quantitative collection can be achieved by 10-cm2 DEN filters under the following optimized conditions: pH 36, filtration rate up to 0.5 ml cm-2 min-1, and sample volume up to 100 ml cm-2. The collection yield is independent of the trace oxoanion concentration up to at least 1.5 μmol cm-2. Although the DEN filter exhibits some selectivity towards oxoanions with a central metal atom, ionic strength affects the results; the collection efficiency is strongly depressed with salt (e.g. NaCl) concentrations above 0.01 M. The applicability of the DEN filter in anion collection is therefore limited to dilute solutions.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)83152-4
|
|
|
“Influence on photoplate evaluation parameters in spark source mass spectrometric analysis”. Verbueken A, Van Grieken R, Bulletin des sociétés chimiques belges 90, 331 (1981)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Multi-element analysis of urine by energy-dispersive x-ray fluorescence spectrometry”. Vos L, Robberecht H, Van Dyck P, Van Grieken R, Analytica chimica acta 130, 167 (1981). http://doi.org/10.1016/S0003-2670(01)84161-1
Abstract: For multi-element analysis of human urine, 25-ml samples doped with yttrium as internal standard are evaporated gently and then ashed up to 460°C overnight. The residue is pelletized and analysed by energy-dispersive x-ray fluorescence. Acid addition to facilitate the digestion is not mandatory. Recoveries are nearly quantitative for traces of Fe, Ni, Cu, Zn and Sr, to a lesser extent for lead, but not for arsenic or selenium. The standard deviation per measurement is typically around 6%. The detection limits are such that some 10 elements can be determined simultaneously in normal urine, and possibly more in cases of importance to toxicology or industrial hygiene.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84161-1
|
|
|
“Pixe analysis of aerosol samples collected over the atlantic-ocean from a sailboat”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester WJ, Nuclear instruments and methods 181, 399 (1981). http://doi.org/10.1016/0029-554X(81)90640-6
Abstract: Size-fractionated aerosol samples, collected over the Atlantic Ocean, were analyzed for up to 20 elements by PIXE. Using a sailboat as sampling platform, duplicate samples were taken for two-day periods by means of battery operated 6-stage cascade impactors, positioned about 8 m above the sea surface. In the PIXE analysis of the fine particle stages (stages 3 to 5) a 5 times smaller beam size was used than for stages 1 and 2. This led to significant improvement in the detection limits for the former stages. The results from the duplicate impactor samples were normally in good agreement, indicating that the combined uncertainty of sampling and PIXE analysis was of the order of 20%. The precision of the PIXE analysis alone was investigated by rebombarding some samples six months after the first analysis. The trends with time of the fine particle sulfur and the coarse particle iron concentrations are discussed in some detail.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0029-554X(81)90640-6
|
|
|
“Co-precipitation with iron hydroxide and X-ray fluorescence analysis of trace metals in water”. Chakravorty R, Van Grieken R, International journal of environmental analytical chemistry 11, 67 (1982). http://doi.org/10.1080/03067318208071563
Abstract: Preconcentration of transition trace ions by coprecipitation on iron-hydroxide has been combined with energy-dispersive X-ray fluorescence for environmental water analysis. The optimized preconcentration procedure implies adding 2 mg of iron to a 200 ml water sample, adding dilute NaOH up to pH 9, filtering off on a Nuclepore membrane after a 1 h equilibration time, and analyzing. Quantitative recoveries could then be obtained for Ni, Cu, Zn and Pb, e.g. at the 10 μg/l level in waters of varying salinity while Mn was partially collected. (In fact, for a given problem the iron carrier amount can be adjusted to obtain a satisfactory compromise between high recovery and low detection limit). The precision is 7-8% at the 10 μg/l level, and the detection limits are in the 0.5-1 μg/l range. Various environmental water samples are analysed by way of illustration.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318208071563
|
|
|
“Evaluation of multi-element analysis of blood serum by energy-dispersive x-ray spectrometry”. Robberecht H, Van Grieken R, Shani J, Barak S, Analytica chimica acta 136, 285 (1982). http://doi.org/10.1016/S0003-2670(01)95388-7
Abstract: Conventional energy-dispersive x-ray fluorescence is applied in the analysis of blood serum to give the concentrations of 710 elements simultaneously with minimal manipulation of the samples. Simple spotting onto a Mylar carrier of 250 μl of serum, doped with two internal standards, was chosen as the sample preparation step. Some 200 serum samples, analyzed in replicate (n = 26), were used to evaluate this procedure. The detection limits are 4 μg ml-1 for K and Ca, 0.50.2 μg ml-1 for Fe, Cu, Pb and Zn, and less than 0.1 μg ml-1 for Se, Rb and Sr. Well above these limits, the standard deviation is around 10%. Comparison with the results of other measurements on the same samples indicates an accuracy of that order. The simplicity and high throughput, and the possibility of automating the x.r.f. measurements, make the proposed procedure suitable for screening large numbers of sera.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95388-7
|
|
|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
|
|
“Losses of metabolically incorporated selenium in common digestion procedures for biological material”. Robberecht HJ, Van Grieken RE, Van den Bosch PA, Deelstra H, vanden Berghe D, Talanta : the international journal of pure and applied analytical chemistry 29, 1025 (1982). http://doi.org/10.1016/0039-9140(82)80244-0
Abstract: Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80244-0
|
|
|
“Percentage selenium in consumed belgian feeding”. Robberecht H, Deelstra H, vanden Berghe D, Van Grieken R, Revue des fermentations et des industries alimentaires 37, 188 (1982)
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Preconcentration methods for the analysis of water by X-ray spectrometric techniques”. Van Grieken R, Analytica chimica acta 143, 3 (1982). http://doi.org/10.1016/S0003-2670(01)95486-8
Abstract: All published procedures for multi-element preconcentration of trace elements, prior to x-ray fluorescence analysis of water, are reviewed and critically evaluated. Most preconcentration methods applied to the determination of single elements in water are also listed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95486-8
|
|
|
“Selenium in environmental waters : determination, speciation and concentration levels”. Robberecht H, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 29, 823 (1982). http://doi.org/10.1016/0039-9140(82)80252-X
Abstract: This article reviews the different methods used for the determination of selenium species in all types of environmental waters. Basic difficulties are discussed and the efficiency of the methods is explained in view of the sub-μg/1. concentration levels. Special attention is paid to preconcentration steps. Published data on speciation and concentration levels in various water samples are critically reviewed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80252-X
|
|
|
“Selenium in the Belgian soils and its uptake by rye-grass”. Robberecht H, vanden Berghe D, Deelstra H, Van Grieken R, The science of the total environment 25, 61 (1982). http://doi.org/10.1016/0048-9697(82)90042-0
Abstract: Data obtained by atomic absorption spectroscopy showed a selenium concentration of only 0.11 ppm as an average value for the most representative agricultural soils in Belgium. The selenium content in rye-grass grown on different soil types was between 0.05 and 0.11 ppm, and positively correlated with the soil selenium level. Addition of selenium in the form of selenite to the different soil types resulted in an increased selenium uptake by the plant. The ultimate concentration in the plant depended on the structural and chemical composition of the soil. Twelve other elements were determined in the soils by energy-dispersive X-ray fluorescence; none showed a strong correlation with the soil selenium content or with the selenium uptake by ryegrass.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(82)90042-0
|
|
|
“Serum bromine levels in psoriasis”. Shani J, Barak S, Ram M, Levi D, Pfeifer Y, Schlesinger T, Avrach WW, Robberecht H, Van Grieken R, Pharmacology 25, 297 (1982). http://doi.org/10.1159/000137756
Abstract: Serum bromine levels in psoriatic Danes increased 2- to 3-fold during a 4-week bathing course in the Dead Sea. This increase correlated well with the improvement in their clinical and psychic condition. Serum bromine levels in psoriatic Danes were somewhat lower than those in healthy subjects residing in Denmark, but the difference was not significant. Israelis working in the open air in the Dead Sea area (air bromine 20-fold higher than in Jerusalem) had higher bromine levels than psoriatic or healthy Israelis residing in Jerusalem or healthy Israelis working in air-conditioned rooms in the Dead Sea area (p < 0.05), but those levels were still within the normal range. As our animal experimentation indicates that the skin is a major target organ for 82Br, applied either by bathing or as an aerosol, we conclude that the higher bromine levels noticed in the psoriatic Danes after their 4-week stay at the Dead Sea may be equally due to their contact with the bromine-containing aerosol and the high bromine level of the Dead Sea waters.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1159/000137756
|
|
|
“Equilibrium constants for trace elements in natural waters”. Van 't dack L, Blommaert W, Vandelannoote R, Gijbels R, van Grieken R, Reviews in analytical chemistry 7, 297 (1983)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace-element geochemistry of thermal water percolating through a karstic environment in the region of Saint Ghislain (Belgium)”. Blommaert W, Vandelannoote R, Sadurski A, Van 't dack L, Gijbels R, Journal of volcanology and geothermal research 19, 331 (1983). http://doi.org/10.1016/0377-0273(83)90117-8
Abstract: Five geothermal waters from the Mons area (southern Belgium) have been studied: one natural hot spring at Stambruges, one stagnant warm water from the inclined tunnels at Baudour, and three thermal waters from the drillholes at St. Ghislain, Ghlin and Douvrain, originating from the carbonate/anhydrite-bearing Visean strata, at depths of ca. 2600, 1550 and 1300 m, respectively. Multielement chemical analysis of the filtered water and its suspended matter > 0.4 μm) was carried out by instrumental neutron activation. Temperature in depth, calculated using the silica (chalcedony) chemical geothermometer, ranged from 75 to 88°C, in good agreement with experimentally determined values. Na/K and Na/K/Ca geothermometers yieilded erratic results, as expected from the geological environment in the aquifer. From the analytical data it can be calculated that the thermal waters of St. Ghislain, Ghlin and Douvrain are not only saturated with respect to chalcedony, but also to anhydrite, calcite, fluorite, barite, strontianite, and possibly zinc silicate, iron (III) hydroxide or siderite, albite, microcline, gibbsite and kaolinite. They are oversaturated with respect to muscovite. Data are also presented for the other thermal waters, and a cold spring water (Claire Fontaine, Stambruges). The similar trace-element composition of the thermal waters can be explained by percolation of the water in the same distant recharge zone, from where it descends, becomes heated at depth and rises along collapse breccia, and locally (Baudour, Stambruges) along fissures. The uptake of higher amounts of Ca, Mg, Sr and sulfate in St. Ghislain and Ghlin, as compared to Douvrain and Baudour is correlated with the boundary between the non-dissolved and dissolved evaporitic zones. This boundary is situated between St. Ghislain and Douvrain, and is roughly parallel with the direction of the groundwater flow (WNW).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.543
Times cited: 2
DOI: 10.1016/0377-0273(83)90117-8
|
|
|
“Atmospheric trace element concentrations in Jerusalem, Israel”. Malenky B, Van Grieken R, Van 't dack L, Luria M, Atmospheric environment 17, 819 (1983). http://doi.org/10.1016/0004-6981(83)90432-8
Abstract: Trace elements found in aerosols were monitored in Jerusalem during the 1979 winter season utilizing an X-ray fluoresence technique. Most of the particulate mass was associated with the natural soil elements, such as Ca, Fe, K and Ti. Only a small fraction of the mass was comprised of elements clearly emitted from human sources, e.g. Pb, Br, V, Ni and Zn. An excellent correspondence was found between the enrichment factors observed in this study and those postulated for other parts of the world. However, the concentration of Ca and Sr in the Jerusalem suspended dust is substantially higher when compared with world averages of urban aerosols.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0004-6981(83)90432-8
|
|
|
“Automated matrix-correction of line ratios in energy-dispersive x-ray fluorescence spectrum deconvolution”. Van Dyck P, Van Grieken R, X-ray spectrometry 12, 111 (1983). http://doi.org/10.1002/XRS.1300120306
Abstract: Most computer XRF-spectrum deconvolution routines make use of fixed intensity ratios for the lines from one element. The magnitude of the error that fixed ratios imply has been quantitatively evaluated for samples with a varible thickness or matrix. A procedure for routinely adapting the line ratios according to the matrix effect in every sample (by making use of the matrix information present in the scatter peaks) enhances the accuracy of the spectrum evaluation.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300120306
|
|