|
“Kinetics of iron(II) oxidation in seawater of various pH”. Roekens EJ, Van Grieken RE, Marine chemistry 13, 195 (1983). http://doi.org/10.1016/0304-4203(83)90014-2
Abstract: The rate of iron(II) oxidation in North Sea water of pH 5.510 in the range 1025°C has been studied. The oxygenation rate depends linearly on the iron(II) and dissolved oxygen concentrations. The second-order dependence on [OH−], found by several investigators for synthetic solutions, was confirmed in seawater, but only for pOH > 6.9. For pOH < 5.9 the rate appeared to be independent of the pOH. In the intermediate range, pOH 5.96.9, corresponding to the natural pH of seawater, a first-order dependence on the pOH is obeyed. The important discrepancy in the literature between the second-order rate constant for NaCHO3 solutions and for seawater can be attributed predominantly to the incorrect assumption of a second-order pOH dependence in natural seawater. The results can be useful, for example, in predicting the effect of dumping acidic iron waste from the titanium-dioxide industry into the ocean.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(83)90014-2
|
|
|
“Trace-elemental anomalies in surface water near a small lead-zinc mineralization at Menez-Albot (Brittany, France)”. Vandelannoote R, Blommaert W, Sadurski A, Van 'T Dack L, Gijbels R, Van Grieken R, Bosch B, Leleu M, Rochon J, Sarcia C, Sureau JF;, Journal of geochemical exploration 20, 33 (1984). http://doi.org/10.1016/0375-6742(84)90088-8
Abstract: Sensitive multi-element analysis techniques were applied to water samples collected in the vicinity of a small Zn-Pb-Cu sulfide mineralization in the region of Menez-Albot (Finistère, France). The variation of the trace-element content along a local stream shows the presence of the mineralization, mainly through a simultaneous positive anomaly in solution for a group of about 10 elements (e.g. Ni, Cu, Zn, As, Sb) which are connected with this type of mineralization. The anomaly decreases steeply due to the influx of swamp water rich in Fe, Mn and organic matter. The precipitation barrier is reflected in the stream sediment composition. Contamination from fertilizers was observed in some samples.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.747
Times cited: 4
DOI: 10.1016/0375-6742(84)90088-8
|
|
|
“2,2′-Diaminodiethylamine cellulose powder for trace metal preconcentrations from water”. Reggers C, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 317, 520 (1984). http://doi.org/10.1007/BF00511918
Abstract: Cellulose powder with 2,2′-diaminodiethylamine (DEN) functional groups exhibits efficient complexation of transition metal cations. Collection yields above 85 % are obtained up to a chelation capacity of 1.5 meq per gram. Since a good collection is obtained for a pH up from 5, no pH adjustments have to be made for natural water samples. The cellulose-DEN powder is insensitive to abundant substances like alkali and alkaline earth ions, and humic matter. Some cations can be eluted efficiently in a small volume of HNO3. Blank concentration levels from the cellulose-DEN powder are reported.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00511918
|
|
|
“Atomic number correction in electron probe X-ray microanalysis of curved samples and particles”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2798 (1984). http://doi.org/10.1021/AC00278A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00278A036
|
|
|
“Composition dependence of Bremsstrahlung background in electron-probe x-ray microanalysis”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2049 (1984). http://doi.org/10.1021/AC00276A016
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00276A016
|
|
|
“Embedded ion exchange beads as standards for laser microprobe mass analysis of biological specimens”. Verbueken AH, Van Grieken RE, Paulus GJ, De Bruijn WC, Analytical chemistry 56, 1362 (1984). http://doi.org/10.1021/AC00272A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00272A036
|
|
|
“Kinetics of iron(II) oxidation in seawater of various pH : reply”. Roekens EJ, Van Grieken RE, Marine chemistry 15, 281 (1984). http://doi.org/10.1016/0304-4203(84)90025-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(84)90025-2
|
|
|
“Laser microprobe mass spectrometric identification of sulfur species in single micrometer-size particles”. Bruynseels FJ, Van Grieken RE, Analytical chemistry 56, 871 (1984). http://doi.org/10.1021/AC00270A004
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00270A004
|
|
|
“Ultrastructural localization of aluminum in patients with dialysis-associated osteomalacia”. Verbueken AH, van de Vijver FL, Van Grieken RE, Paulus GJ, Visser WJ, d'Haese P, de Broe ME, Clinical chemistry : international journal of laboratory medicine and molecular diagnostics 30, 763 (1984)
Abstract: Using laser microprobe mass analysis, we studied the ultrastructural localization of aluminum in liver and bone tissue of chronic-hemodialysis patients with proven aluminum-induced osteomalacia. In the liver, aluminum was observed to be almost exclusively associated with iron. Detectable aluminum and large amounts of iron were found in lysosomes of both hepatocytes and Kupffer cells. In bone, aluminum was localized at the osteoid/calcified-bone interface and also was associated with iron in some cases.
Keywords: A1 Journal article; Pharmacology. Therapy; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Reviews in analytical chemistry 56, 241r (1984)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Bremsstrahlung background in electron-probe X-ray-microanalysis of thin films”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 57, 2885 (1985). http://doi.org/10.1021/AC00291A032
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00291A032
|
|
|
“Characterization of individual particle types in coastal air by laser microprobe mass analysis”. Bruynseels F, Storms H, Tavares T, Van Grieken R, International journal of environmental analytical chemistry 23, 1 (1985). http://doi.org/10.1080/03067318508076430
Abstract: Laser Microprobe Mass Analysis (LAMMA) was used in a preliminary study to characterize aerosol particles from a beach and inland sites and from a heavily industrialized area. As many as six types of both positive and negative mass spectra with different inorganic and organic signals could be distinguished in the different particle size ranges. Information about the elemental composition and the speciation of S and N was obtained. With increasing distance from sea, progressive uptake of nitrate in seasalt particles was found. Complex particles, containing soot and organic ammonium sulfate, were also detected.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318508076430
|
|
|
“Chemical composition of river sediments from the Indian sub-continent”. Subramanian V, Van 't dack L, Van Grieken R, Chemical geology 48, 271 (1985). http://doi.org/10.1016/0009-2541(85)90052-X
Abstract: River sediments from all of the major drainage basins (except the Indus) in the Indian sub-continent were collected and analysed by thin-film X-ray fluorescence technique (XRF) to determine their chemical composition. On the basis of analysis of more than 120 samples, average chemical compositions of river-borne sediments from the Indian sub-continent have been calculated. Also, average concentration values for sediments from each of the river basins, and the sub-continent average and the inter-basin differences are discussed in relation to weathering processes in the drainage basins. Comparisons have been made with the chemistry of sediments from the Bay of Bengal (which receives the bulk of sediments delivered by Indian rivers). Our observations are discussed in the light of average chemical composition of world-river sediments and the world surface rock exposed for continental weathering.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0009-2541(85)90052-X
|
|
|
“Investigation of heterogeneous reactions of PAH's on particle surfaces using laser microprobe mass analysis”. Niessner R, Klockow D, Bruynseels F, Van Grieken R, International journal of environmental analytical chemistry 22, 281 (1985). http://doi.org/10.1080/03067318508076427
Abstract: Artificially generated NaCl particles were coated with PAH's by using a condensation technique. These particles were exposed to reactive gases like ozone, bromine and nitrogen dioxide. The original as well as the exposed particles were investigated by fluorimetric analysis and by LAMMA (Laser Microprobe Mass Analysis) in the desorption mode, which allows the evaporation and characterization of surfaces of single particles. The results are interpreted in terms of possible heterogeneous atmospheric reactions. The reactivity of the considered PAH's towards nitrogen dioxide was found to be negligible. The structure of the reaction products formed with ozone was partially elucidated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318508076427
|
|
|
van de Vijver FL, Verbueken AH, Van Grieken RE, de Broe ME, Visser WJ (1985) Laser microprobe mass analysis : a tool for evaluating histochemical staining of trace elements. 351–352
Keywords: L1 Letter to the editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Matrix effects and analysis of biological material by spark source mass spectrometry”. Vos L, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 321, 32 (1985). http://doi.org/10.1007/BF00464483
Abstract: Spark-source mass spectrometric analyses of synthetic simulated biological samples were performed to determine the importance of matrix effects. A correlation between the variation of the relative sensitivity coefficients (RSC's) and the spark plasma composition, hence plasma temperature, was found. The determined RSC's were used in the analysis of four biological standard reference materials. An accuracy of 1013% and detection limits between 0.005 and 0.5 ppm were obtained during analysis under normal conditions.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00464483
|
|
|
“Hydrogeochemistry in the zinclead mining district of Les Malines (Gard, France)”. Bosch B, Leleu M, Oustrière P, Sarcia C, Sureau JF, Blommaert W, Gijbels R, Sadurski A, Vandelannoote R, Van Grieken R, Van 'T Dack L;, Chemical geology 55, 31 (1986). http://doi.org/10.1016/0009-2541(86)90125-7
Abstract: Sensitive multi-element analysis techniques together with major-element and isotopic analyses were applied to spring, mine and surface waters in the vicinity of an important known zinclead deposit in a carbonate environment, in the Les Malines area (Gard, France). Both the dissolved and suspended phases were investigated, and concretions and sediments were also considered in some cases. This methodological test shows that the ore body leaves various clear fingerprints, such as the Zn, As, Sb, Pb and U levels in the dissolved phase, the sulfate increment and the δ 34S. Some of the elements in solution are controlled by slightly soluble compounds, e.g. Zn by smithsonite and hydrozincite, Ba by barite, and Pb by hydrocerussite. Mapping the saturation indices for these elements appears useful for displaying the hydrogeochemical anomaly.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.524
Times cited: 3
DOI: 10.1016/0009-2541(86)90125-7
|
|
|
“AXIL-PC, software for the analysis of complex-x-ray spectra”. van Espen P, Janssens K, Nobels J, Chemometrics and intelligent laboratory systems 1, 109 (1986). http://doi.org/10.1016/0169-7439(86)80031-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(86)80031-4
|
|
|
“Absorption correction in electron probe x-ray microanalysis of thin samples”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 58, 1282 (1986). http://doi.org/10.1021/AC00298A003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00298A003
|
|
|
“Energy-dispersive X-ray spectrometry : present state and trends”. Van Grieken R, Markowicz A, Török S, Fresenius' Zeitschrift für analytische Chemie 324, 825 (1986). http://doi.org/10.1007/BF00473177
Abstract: Recent development, present state and expected future developments in energy-dispersive X-ray spectrometry are discussed. Attention is paid to the improvements in analytical selectivity, sensitivity, detection limit, quantitative character and applicability range, which are the result of new or better excitation sources, detectors, instrument design, automation, computer software and theoretical developments.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00473177
|
|
|
“Enhancement effect in X-ray fluorescence analysis of environmental samples of medium thickness”. Van Dyck PM, Török SB, Van Grieken RE, Analytical chemistry 58, 1761 (1986). http://doi.org/10.1021/AC00121A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00121A036
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 58, 279r (1986). http://doi.org/10.1021/AC00296A019
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00296A019
|
|
|
“A general-purpose interface between fortran and the low-level functions of the ibm-pc”. Janssens K, van Espen P, Trends in analytical chemistry 7, 128 (1988). http://doi.org/10.1016/0165-9936(88)87009-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0165-9936(88)87009-2
|
|
|
“PC-MCA : a software package for the acquisition and processing of spectral data”. Janssens K, Nobels J, van Espen P, Chemometrics and intelligent laboratory systems 3, 335 (1988). http://doi.org/10.1016/0169-7439(88)80033-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80033-9
|
|
|
“The development process of an expert system for the automated interpretation of large epma data sets”. Janssens K, Dorrine W, van Espen P, Chemometrics and intelligent laboratory systems 4, 147 (1988). http://doi.org/10.1016/0169-7439(88)80086-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80086-8
|
|
|
“Characterization of individual estuarine and marine particles by LAMMA and EPXMA”. Wouters L, Bernard P, Van Grieken R, International journal of environmental analytical chemistry 34, 17 (1988). http://doi.org/10.1080/03067318808029918
Abstract: Laser microprobe mass analysis (LAMMA) was applied to particulate matter from the Atlantic Ocean. Inferring information about the surface layer by LAMMA was not probe X-ray microanalysis (EPXMA). Geochemically relevant groups of particles had been identified by EPXMA and cluster analysis. For both locations, the most abundant ones appeared to be those rich in silicon and the alumino-silicates. Afterwards LAMMA was applied to obtain more information about the trace element composition and surface characteristics. The iron-rich phase appeared to contain significant amounts of heavy metals and of phosphate. Lead appeared to be associated in detectable amounts with alumino-silicates in the Scheldt but not with those in the Atlantic Ocean. Inferring information about the surface layer by LAMMA was not always unambiguous.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318808029918
|
|
|
“Discrimination between coprecipitated and adsorbed lead on individual calcite particles using laser microprobe mass analysis”. Wouters LC, Van Grieken RE, Linton RW, Bauer CF, Analytical chemistry 60, 2218 (1988). http://doi.org/10.1021/AC00171A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00171A011
|
|
|
“A microanalytical study of the gills of aluminium-exposed rainbow trout (Salmo gairdneri)”. Goossenaerts C, Van Grieken R, Jacob W, Witters H, Vanderborght O, International journal of environmental analytical chemistry 34, 227 (1988). http://doi.org/10.1080/03067319808026840
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319808026840
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 60, 28r (1988). http://doi.org/10.1021/AC00163A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00163A002
|
|
|
“The elemental chemistry of sediments in the Krishna River basin, India”. Ramesh R, Subramanian V, Van Grieken R, Van 't dack L, Chemical geology 74, 331 (1989). http://doi.org/10.1016/0009-2541(89)90042-9
Abstract: Composition of bed, core and suspended sediments collected from Krishna River sediments were studied and the observations are discussed in the light of other Indian rivers, world's average river suspended particles, surficial rock and soils. The contents of V, Cr, Co, Ni, Cu and Zn in the suspended particles are higher in the Krishna River than in the world's average, indicating pollution inputs. Suspended sediments are enriched (5 to 10 times) in all the elements considered relative to bed sediments. Downstream profile and metal/Al ratios of the elements indicate that the mobility of elements within the basin is controlled by basin geology, size and mineralogical characteristics. Good correlations observed for a number of elements point out to their common sink in the clay fraction of the sediments. There is no systematic variation with depth for the major elements and most of the elements are considerably higher compared to estuarine or Bay of Bengal sediments.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0009-2541(89)90042-9
|
|