“Collisional-radiative model for the sputtered copper atoms and ions in a direct current argon glow discharge”. Bogaerts A, Gijbels R, Carman RJ, Spectrochimica acta: part B : atomic spectroscopy 53, 1679 (1998). http://doi.org/10.1016/S0584-8547(98)00201-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 71
DOI: 10.1016/S0584-8547(98)00201-8
|
|
|
“Comprehensive description of a Grimm-type glow discharge source used for optical emission spectrometry: a mathematical simulation”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 53, 437 (1998). http://doi.org/10.1016/S0584-8547(97)00148-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 46
DOI: 10.1016/S0584-8547(97)00148-1
|
|
|
“Comprehensive three-dimensional modeling network for a dc glow discharge plasma”. Bogaerts A, Gijbels R, Plasma physics reports 24, 573 (1998)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 0.984
Times cited: 8
|
|
|
“Fundamental aspects and applications of glow discharge spectrometric techniques”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 53, 1 (1998). http://doi.org/10.1016/S0584-8547(97)00122-5
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 49
DOI: 10.1016/S0584-8547(97)00122-5
|
|
|
“Influence of sticking coefficients on the behavior of sputtered atoms in an argon glow discharge: modeling and comparison with experiment”. Bogaerts A, Naylor J, Hatcher M, Jones WJ, Mason R, Journal of vacuum science and technology: A: vacuum surfaces and films 16, 2400 (1998). http://doi.org/10.1116/1.581359
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.374
Times cited: 12
DOI: 10.1116/1.581359
|
|
|
“Modeling of argon direct current glow discharges and comparison with experiment: how good is the agreement?”.Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 13, 945 (1998). http://doi.org/10.1039/a800329g
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 24
DOI: 10.1039/a800329g
|
|
|
“Modeling of glow discharge optical emission spectrometry: calculation of the argon atomic optical emission spectrum”. Bogaerts A, Gijbels R, Vlcek J, Spectrochimica acta: part B : atomic spectroscopy 53, 1517 (1998). http://doi.org/10.1016/S0584-8547(98)00139-6
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 44
DOI: 10.1016/S0584-8547(98)00139-6
|
|
|
“Comparison between a radio-frequency and direct current glow discharge in argon by a hybrid Monte Carlo-fluid model for electrons, argon ions and fast argon atoms”. Bogaerts A, Gijbels R, Goedheer W, Spectrochimica acta: part B : atomic spectroscopy 54, 1335 (1999). http://doi.org/10.1016/S0584-8547(99)00080-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 11
DOI: 10.1016/S0584-8547(99)00080-4
|
|
|
“Comprehensive modelling network for dc glow discharges in argon”. Bogaerts A, Plasma sources science and technology 8, 210 (1999). http://doi.org/10.1088/0963-0252/8/2/003
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 27
DOI: 10.1088/0963-0252/8/2/003
|
|
|
“The glow discharge: an exciting plasma”. Bogaerts A, Journal of analytical atomic spectrometry 14, 1375 (1999). http://doi.org/10.1039/a900772e
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 29
DOI: 10.1039/a900772e
|
|
|
“Hybrid modeling of a capacitively coupled radio frequency glow discharge in argon: combined Monte Carlo and fluid model”. Bogaerts A, Gijbels R, Goedheer W, Japanese journal of applied physics 38, 4404 (1999). http://doi.org/10.1143/JJAP.38.4404
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.384
Times cited: 45
DOI: 10.1143/JJAP.38.4404
|
|
|
“Investigation of the electron distribution functions in low pressure electron cyclotron resonance discharges”. Kaganovich I, Misina M, Bogaerts A, Gijbels R Kluwer Academic, Dordrecht, page 543 (1999).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Modeling of ionization of argon in an analytical capacitively coupled radio-frequency glow discharge”. Bogaerts A, Yan M, Gijbels R, Goedheer W, Journal of applied physics 86, 2990 (1999). http://doi.org/10.1063/1.371159
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 18
DOI: 10.1063/1.371159
|
|
|
“Modelling of radio frequency capacitively coupled plasma at intermediate pressures”. Berezhnoi S, Kaganovich I, Bogaerts A, Gijbels R Kluwer Academic, Dordrecht, page 525 (1999).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Monte Carlo model for the argon ions and fast argon atoms in a radio-frequency discharge”. Bogaerts A, Gijbels R, IEEE transactions on plasma science 27, 1406 (1999). http://doi.org/10.1109/27.799819
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 15
DOI: 10.1109/27.799819
|
|
|
“New developments and applications in GDMS”. Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 364, 367 (1999). http://doi.org/10.1007/s002160051352
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 17
DOI: 10.1007/s002160051352
|
|
|
“Role of Ar2+ and Ar+2 ions in a direct current argon glow discharge: a numerical description”. Bogaerts A, Gijbels R, Journal of applied physics 86, 4124 (1999). http://doi.org/10.1063/1.371337
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 50
DOI: 10.1063/1.371337
|
|
|
“A self-consistent mathematical model of a hollow cathode glow discharge”. Baguer N, Bogaerts A, Gijbels R, , 157 (1999)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Semianalytical description of nonlocal secondary electrons in a radio-frequency capacitively coupled plasma at intermediate pressures”. Berezhnoi S, Kaganovich I, Misina M, Bogaerts A, Gijbels R, IEEE transactions plasma science 27, 1339 (1999). http://doi.org/10.1109/27.799810
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 7
DOI: 10.1109/27.799810
|
|
|
“Simulation of plasma processes in plasma assisted CVD reactors”. Herrebout D, Bogaerts A, Goedheer W, Dekempeneer E, Gijbels R, , 213 (1999)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Behavior of the sputtered copper atoms, ions and excited species in a radio-frequency and direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 55, 279 (2000). http://doi.org/10.1016/S0584-8547(00)00142-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 17
DOI: 10.1016/S0584-8547(00)00142-7
|
|
|
“Calculation of gas heating in direct current argon glow discharges”. Bogaerts A, Gijbels R, Serikov VV, Journal of applied physics 87, 8334 (2000). http://doi.org/10.1063/1.373545
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 63
DOI: 10.1063/1.373545
|
|
|
“Comparison of calculated and measured optical emission intensities in a direct current argon-copper glow discharge”. Bogaerts A, Donko Z, Kutasi K, Bano G, Pinhao N, Pinheiro M, Spectrochimica acta: part B : atomic spectroscopy 55, 1465 (2000). http://doi.org/10.1016/S0584-8547(00)00253-6
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 33
DOI: 10.1016/S0584-8547(00)00253-6
|
|
|
“Description of the argon-excited levels in a radio-frequency and direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 55, 263 (2000). http://doi.org/10.1016/S0584-8547(00)00143-9
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 24
DOI: 10.1016/S0584-8547(00)00143-9
|
|
|
“Effects of adding hydrogen to an argon glow discharge: overview of relevant processes and some qualitative explanations”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 441 (2000). http://doi.org/10.1039/a909779a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 58
DOI: 10.1039/a909779a
|
|
|
“Electron energy distribution function in capacitively coupled RF discharges: differences between electropositive Ar and electronegative SiH4 discharges”. Yan M, Bogaerts A, Goedheer WJ, Gijbels R, Plasma sources science and technology 9, 583 (2000). http://doi.org/10.1088/0963-0252/9/4/314
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 21
DOI: 10.1088/0963-0252/9/4/314
|
|
|
“An extended RF methane plasma 1D fluid model of interest in deposition of diamond-like carbon layers”. Herrebout D, Bogaerts A, Yan M, Goedheer W, Dekempeneer E, Gijbels R, , 399 (2000)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Glow discharge mass spectrometry, methods”. Bogaerts A Academic Press, San Diego, Calif., page 669 (2000).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Hybrid Monte Carlo-fluid model for a microsecond pulsed glow discharge”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 895 (2000). http://doi.org/10.1039/b003398g
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/b003398g
|
|
|
“Modeling network for argon glow discharges: the output cannot be better than the input”. Bogaerts A, Gijbels R American Institute of Physics, Melville, N.Y., page 49 (2000).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 1
|
|