“Methods of structural analysis of modulated structures and quasicrystals”. van Landuyt J, Kuypers S, van Heurck C, Van Tendeloo G, Amelinckx S s.l., page 205 (1993).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
“Radiation defects and ordered radiation patterns in Ni and Ni4Mo: a study by electron microscopy”. De Meulenaere P, Van Tendeloo G, van Landuyt J, Mommaert C, Severne G, Philosophical magazine: A: physics of condensed matter: defects and mechanical properties 67, 745 (1993). http://doi.org/10.1080/01418619308207187
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 1
DOI: 10.1080/01418619308207187
|
“Round-robin investigation of silicon-oxide on silicon reference materials for ellipsometry”. Vanhellemont J, Maes HE, Schaekers M, Armigliato A, Cerva H, Cullis A, de Sande J, Dinges H, Hallais J, Nayar V, Pickering C, Stehlé, JL, Van Landuyt J, Walker C, Werner H, Salieri P;, Applied surface science
T2 –, SYMP ON DIAGNOSTIC TECHNIQUES FOR SEMICONDUCTOR MATERIALS ANALYSIS AND, FABRICATION PROCESS CONTROL, AT THE 1992 SPRING CONF OF THE EUROPEAN, MATERIALS RESEARCH SOC, JUN 02-05, 1992, STRASBOURG, FRANCE 63, 45 (1993). http://doi.org/10.1016/0169-4332(93)90062-G
Abstract: The main results and conclusions are presented of a round robin study of silicon oxide on silicon reference samples for ellipsometry. The oxide films with nominal thicknesses of 10, 50 and 120 nm are grown by thermal oxidation. The oxide film thicknesses have been determined by single wavelength ellipsometry (SWE), by spectroscopic ellipsometry (SE) and by cross-sectional conventional and high-resolution transmission electron microscopy (TEM and HREM) in different laboratories. The main conclusions are that special precautions have to be taken in order to use TEM as a reliable thickness measurement technique; that single wavelength ellipsometry can be used with great accuracy and reproducibility for the 50 and 120 nm film thicknesses but that it shows some inherent problems for the 10 nm films; and that spectroscopic ellipsometry showed for all film thicknesses an accuracy and reproducibility which is clearly superior to that of SWE.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.711
Times cited: 13
DOI: 10.1016/0169-4332(93)90062-G
|
“Structural effects of element substitution in the CuO plane of the 1-2-3 YBCO superconductor”. Krekels T, Van Tendeloo G, Amelinckx S, van Landuyt J, Acta crystallographica: section A: foundations of crystallography 49, 287 (1993)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.307
Times cited: 56
|
“The study of partially ordered 11/20 alloys by HREM”. De Meulenaere P, Van Tendeloo G, van Landuyt J, Microscopy research and technique 25, 169 (1993). http://doi.org/10.1002/jemt.1070250208
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.154
DOI: 10.1002/jemt.1070250208
|
“Superlattice variants in Sr2CuO2(CO3): an electron microscopy study”. Milat O, Van Tendeloo G, van Landuyt J, Amelinckx S, Acta crystallographica: section A: foundations of crystallography 49, 357 (1993)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.307
|
“SO4-chain formation and ordering in [YSrCa]Sr2Cu2.78(SO4)0.22O7-\delta”. Krekels T, Milat O, Van Tendeloo G, van Landuyt J, Amelinckx S, Slater PR, Greaves C, Physica: C : superconductivity 210, 439 (1993). http://doi.org/10.1016/0921-4534(93)90988-3
Abstract: YBCO-based materials containing SO4-tetrahedra centered on the Cu(1)-sites of the CuO-chain plane have been examined by means of electron diffraction and high resolution electron microscopy. An incommensurate modulation is observed and attributed to the ordering of b-oriented SO4-rich chains in the Cu(1)-S-O-layer, described in terms of an SO4-concentration wave.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.942
Times cited: 18
DOI: 10.1016/0921-4534(93)90988-3
|
“Crystallography of fullerites and related graphene textures”. van Landuyt J, Van Tendeloo G, Amelinckx S, Zhang XF, Zhang XB, Luyten W, Materials science forum 150/151, 53 (1994)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
|
“Direct observation of clusters in some FCC alloys by HREM”. De Meulenaere P, Van Tendeloo G, van Landuyt J, Icem 13, 447 (1994)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
|
“Direct observation of laser-induced crystallization of a-C : H films”. Nistor LC, van Landuyt J, Ralchenko VG, Kononenko TV, Obraztsova ED, Strelnitsky VE, Applied physics A : materials science &, processing 58, 137 (1994). http://doi.org/10.1007/BF00332170
Abstract: The post-growth modification of diamond-like amorphous hydrogenated carbon a-C:H films by laser treatment has been studied by transmission electron microscopy and Raman spectroscopy. a-C:H films grown on Si substrates by benzene decomposition in a rf glow discharge were irradiated with 15 ns pulses of a KrF-excimer laser with fluences in the ran e of E = 50-700 mJ/cm(2). At fluences below 100 mJ/cm(2) an increase in the number of graphitic clusters and in their ordering was evidenced from Raman spectra, while the film structure remained amorphous according to electron microscopy and electron diffraction observations. At higher fluences the appearance of diamond particles of 2-7 nm size, embedded into the lower crystallized graphitic matrix, was observed and simultaneously a progressive growth of graphite nanocrystals with dimensions from 2 nm to 4 nm was deduced from Raman measurements. The maximum thickness of the crystallized surface layer (approximate to 400 nm) and the degree of laser annealing are limited by the film ablation which starts at E > 250 mJ/cm(2). The laser-treated areas lose their chemical inertness. In particular, chemical etching in chromium acid becomes possible, which may be used for patterning the highly inert carbon films.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 73
DOI: 10.1007/BF00332170
|
“Electron diffraction evidence for ordering of interstitial silver ions in silver bromide microcrystals”. Goessens C, Schryvers D, van Dyck D, van Landuyt J, de Keyzer R, Icem 13 (1994)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
|
“Electron-diffraction evidence for ordering of interstitial silver ions in silver bromide microcrystals”. Goessens C, Schryvers D, van Dyck D, van Landuyt J, de Keyzer R, Physica status solidi: A 143, 277 (1994). http://doi.org/10.1002/pssa.2211430211
Abstract: The occurrence and origin of diffuse intensity contours in electron micrographs of AgBr crystals are investigated. The observations are interpreted in terms of a model, which attributes diffuse scattering to the presence of predominant atom or vacancy clusters of a particular polyhedral type. It is shown that irrespective of the crystal morphology, interstitial Ag ions order in AgBr material in clusters of finite size along 001 type planes. A different geometry of the diffuse intensity locus observed for triangular and hexagonal tabular grains is explained in terms of the different twin plane morphology of these grains.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Times cited: 7
DOI: 10.1002/pssa.2211430211
|
“Electron microscopy of fullerenes and fullerene related structures”. Van Tendeloo G, van Landuyt J, Amelinckx S, , 498 (1994)
Keywords: P3 Proceeding; Electron microscopy for materials research (EMAT)
|
“EM study of sensitisation of silver halide grains”. Buschmann V, Schryvers D, van Landuyt J, van Roost C, Icem 13 (1994)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
|
“Formation of diamond nanocrystals in laser-irradiated amorphous carbon films”. Nistor LC, van Landuyt J, Ralchenko VG, Kononenko TV, Obraztsova ED, Strelnitsky VE, International Conference on the New Diamond Science and Technology 4, 25 (1994)
Keywords: P3 Proceeding; Electron microscopy for materials research (EMAT)
|
“High-resolution electron microscopy for semiconducting materials science”. van Landuyt J, Vanhellemont J Elsevier, Amsterdam, page 1109 (1994).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
“HREM imaging analysis in the study of pretransition and nucleation phenomena in alloys”. Schryvers D, Van Tendeloo G, van Landuyt J, Tanner LE, Icem 13, 659 (1994)
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT)
|
“HREM imaging analysis in the study of pretransition and nucleation phenomena in alloys (Invited)”. Schryvers D, Van Tendeloo G, van Landuyt J, Le Tanner, , 659 (1994)
Keywords: P1 Proceeding; Electron microscopy for materials research (EMAT)
|
“HREM study of Rb6C60 and helical carbon nanotubules”. Bernaerts D, Zhang XB, Zhang XF, Van Tendeloo G, van Landuyt J, Amelinckx S, Icem 13, 305 (1994)
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT)
|
“Laser induced phase transition in iron thin films”. Teodorescu VS, Mihailescu IN, Dinescu M, Chitica N, Nistor LC, van Landuyt J, Barborica A, Journal de physique: 3: applied physics, materials science, fluids, plasma and instrumentation 4, 127 (1994). http://doi.org/10.1051/jp4:1994427
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 2
DOI: 10.1051/jp4:1994427
|
“Ordering and defects in BanTaxTiyO3n ternary oxides”. Nistor L, Van Tendeloo G, Amelinckx S, Shpanchenko RV, van Landuyt J, Electron Microscopy 1994, Vols 2a And 2b: Applications In Materials Sciences , 869 (1994)
Keywords: P1 Proceeding; Electron microscopy for materials research (EMAT)
|
“The reciprocal space of carbon tubes: a detailed interpretation of the electron diffraction effects”. Zhang XB, Zhang XF, Amelinckx S, Van Tendeloo G, van Landuyt J, Ultramicroscopy 54, 237 (1994). http://doi.org/10.1016/0304-3991(94)90123-6
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 59
DOI: 10.1016/0304-3991(94)90123-6
|
“A simple preparation method for air-sensitive specimens for transmission electron microscopy demonstrated by Rb6C60”. Zhang XF, Zhang XB, Bernaerts D, Van Tendeloo G, Amelinckx S, van Landuyt J, Werner H, Ultramicroscopy 55, 25 (1994). http://doi.org/10.1016/0304-3991(94)90077-9
Abstract: In this paper a particularly simple but efficient method is presented by which samples of alkali-doped C-60 materials or other air-sensitive materials can be prepared and transferred into a transmission electron microscope for direct observations and investigations. Flexible, transparent glove bags are used which are filled to a slight overpressure with dry nitrogen. Under this protective atmosphere, the air-sensitive sample is mounted in the specimen holder and inserted in the vacuum of the electron microscope. Rb6C60 which is prepared and transferred into the microscope in this way has been investigated by transmission electron microscopy (TEM). The results confirm the bcc structure and especially the location of the rubidium atoms.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 2
DOI: 10.1016/0304-3991(94)90077-9
|
“The study of carbon nanotubes produced by catalytic method”. Ivanov V, Nagy JB, Lambin P, Lucas A, Zhang XB, Zhang XF, Bernaerts D, Van Tendeloo G, Amelinckx S, van Landuyt J, Chemical physics letters 223, 329 (1994)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.897
Times cited: 405
|
“TEM study of laser induced phase transition in iron thin films”. Teodorescu VS, Nistor LC, van Landuyt J, Dinescu M, Materials research bulletin 29, 63 (1994). http://doi.org/10.1016/0025-5408(94)90106-6
Abstract: Laser induced phase transition from b.c.c.(alpha) to f.c.c.(gamma) iron thin films is studied by high resolution TEM. The iron film has been covered on both sides with carbon layers to protect it against oxidation. Single pulse, tau FWHM = 20ns KrF (lambda = 248nm) excimer laser irradiation was performed in air with the film on the substrate. The laser pulse acts like a heat pulse followed by a rapid quenching revealing sequential aspects of the phase transition process. The presence of a fine mixture of the alpha + gamma phases between the alpha and gamma regions of the film has been interpreted as an incomplet transformation. The results are explained by assuming that the transformation took place via a phonon drag mechanism.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.288
Times cited: 2
DOI: 10.1016/0025-5408(94)90106-6
|
“The texture of catalytically grown coil-shaped carbon nanotubes”. Zhang XB, Zhang XF, Bernaerts D, Van Tendeloo G, Amelinckx S, van Landuyt J, Ivanov V, Nagy JB, Lambin P, Lucas AA, Europhysics letters 27, 141 (1994). http://doi.org/10.1209/0295-5075/27/2/011
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.095
Times cited: 168
DOI: 10.1209/0295-5075/27/2/011
|
“The study of carbon nanotubules produced by catalytic method”. Ivanov V, Nagy JB, Lambin P, Lucas A, Zhang XB, Zhang XF, Bernaerts D, Van Tendeloo G, Amelinckx S, van Landuyt J, Chemical physics letters 223, 329 (1994). http://doi.org/10.1016/0009-2614(94)00467-6
Abstract: Catalytic methods for the production of carbon nanotubules have been developed based on the decomposition of acetylene on well-dispersed metal particles strongly adsorbed on a support. Cobalt on silica was found to be the best catalyst-support combination for the production of graphitic tubules. The method for the catalyst preparation and the reaction conditions were optimized. Straight and coiled carbon tubules were obtained with inner and outer diameter of 3-7 and 15-20 nm, respectively, and up to 30 mum in length. These nanotubules were not coated by amorphous carbon. Traces of amorphous carbon could be removed by hydrogen. High resolution electron microscopy images and electron diffraction patterns of the straight nanotubules were similar to those obtained by the arc-discharge method. Coiled nanotubules were revealed by TEM to be regular polygonized helices where the bends are caused by pairs of pentagon-heptagon carbon rings among the hexagonal network.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.897
Times cited: 405
DOI: 10.1016/0009-2614(94)00467-6
|
“A transmission electron-microscopy study of crystalline surface domains on al-co decagonal quasi-crystals and the \tau2-Al13CO4 approximant”. Zhang Z, Ma LN, Liao XZ, van Landuyt J, Philosophical magazine letters 70, 303 (1994). http://doi.org/10.1080/09500839408240991
Abstract: Twin-domains of a b.c.c. crystalline phase with a = 0.29 nm have been found in a surface layer on surfaces of Al-Co decagonal quasicrystals and the coexisting tau(2)-Al13Co4 crystalline approximant. These surface layer domains are introduced during the preparation of electron microscopy thin films by ion milling.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.087
Times cited: 4
DOI: 10.1080/09500839408240991
|
“Up close: Center for Electron Microscopy of Materials Science at the University of Antwerp”. Van Tendeloo G, Schryvers D, van Dyck D, van Landuyt J, Amelinckx S, MRS bulletin , 57 (1994)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 5.667
|
“Dynamical electron diffraction in substitutionally disordered column structures”. De Meulenaere P, van Dyck D, Van Tendeloo G, van Landuyt J, Ultramicroscopy 60, 171 (1995). http://doi.org/10.1016/0304-3991(95)00040-8
Abstract: For column structures, such as fee-based alloys viewed along the cube direction, the concept of electron channelling through the atom columns is more and more used to interpret the corresponding HREM images. In the case of(partially) disordered columns, the projected potential approach which is used in the channelling description must be questioned since the arrangement of the atoms along the beam direction might affect the exit wave of the electrons. In this paper, we critically inspect this top-bottom effect using multi-slice calculations. A modified channelling theory is introduced which turns out to be very appropriate for the interpretation of these results. For substitutionally disordered column structures, it is also discussed how to link the chemical composition of the material to statistical data of the HREM image. This results in a convenient tool to discern images taken at different thicknesses and focus values.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 14
DOI: 10.1016/0304-3991(95)00040-8
|