“Background aerosol composition at Gobabeb, South West Africa”. Annegarn H, Van Grieken R, van Espen P, von Blottnitz F, Sellschop J, Winchester J, Maenhaut W, Madoqua , 107 (1976)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Effective sample weight from scatter peaks in energy-dispersive x-ray fluorescence”. van Espen P, Van 't dack L, Adams F, Van Grieken R, Analytical chemistry 51, 961 (1979). http://doi.org/10.1021/AC50043A042
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1021/AC50043A042
|
|
|
“Sulfur and heavy metals over the Atlantic Ocean : comparison with other marine data”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester JW, (1980)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Pixe analysis of aerosol samples collected over the atlantic-ocean from a sailboat”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester WJ, Nuclear instruments and methods 181, 399 (1981). http://doi.org/10.1016/0029-554X(81)90640-6
Abstract: Size-fractionated aerosol samples, collected over the Atlantic Ocean, were analyzed for up to 20 elements by PIXE. Using a sailboat as sampling platform, duplicate samples were taken for two-day periods by means of battery operated 6-stage cascade impactors, positioned about 8 m above the sea surface. In the PIXE analysis of the fine particle stages (stages 3 to 5) a 5 times smaller beam size was used than for stages 1 and 2. This led to significant improvement in the detection limits for the former stages. The results from the duplicate impactor samples were normally in good agreement, indicating that the combined uncertainty of sampling and PIXE analysis was of the order of 20%. The precision of the PIXE analysis alone was investigated by rebombarding some samples six months after the first analysis. The trends with time of the fine particle sulfur and the coarse particle iron concentrations are discussed in some detail.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0029-554X(81)90640-6
|
|
|
Gijbels R, van Grieken R, Blommaert W, Van 't dack L, van Espen P, Nullens H, Saelens R (1983) Application of analytical methods for trace elements in geothermal waters : part 2 : Plombières, Bains-les-Bains, Bourbonne (Vosges). S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“AXIL-PC, software for the analysis of complex-x-ray spectra”. van Espen P, Janssens K, Nobels J, Chemometrics and intelligent laboratory systems 1, 109 (1986). http://doi.org/10.1016/0169-7439(86)80031-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(86)80031-4
|
|
|
“Evaluation of energy-dispersive x-ray-spectra with the aid of expert systems”. Janssens K, van Espen P, Analytica chimica acta 191, 169 (1986). http://doi.org/10.1016/S0003-2670(00)86306-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86306-0
|
|
|
“Implementation of an expert system for the qualitative interpretation of x-ray-fluorescence spectra”. Janssens K, van Espen P, Analytica chimica acta 184, 117 (1986). http://doi.org/10.1016/S0003-2670(00)86475-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86475-2
|
|
|
“A general-purpose interface between fortran and the low-level functions of the ibm-pc”. Janssens K, van Espen P, Trends in analytical chemistry 7, 128 (1988). http://doi.org/10.1016/0165-9936(88)87009-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0165-9936(88)87009-2
|
|
|
“Increased accuracy in the automated interpretation of large epma data sets by the use of an expert system”. Janssens K, Vanborm W, van Espen P, Journal of research of the National Bureau of Standards (1934) 93, 260 (1988). http://doi.org/10.6028/JRES.093.037
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.6028/JRES.093.037
|
|
|
“PC-MCA : a software package for the acquisition and processing of spectral data”. Janssens K, Nobels J, van Espen P, Chemometrics and intelligent laboratory systems 3, 335 (1988). http://doi.org/10.1016/0169-7439(88)80033-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80033-9
|
|
|
“The development process of an expert system for the automated interpretation of large epma data sets”. Janssens K, Dorrine W, van Espen P, Chemometrics and intelligent laboratory systems 4, 147 (1988). http://doi.org/10.1016/0169-7439(88)80086-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80086-8
|
|
|
“The elemental composition of airborne particulate matter in the Atacama desert, Chile”. Rojas CM, Figueroa L, Janssens KH, Van Espen PE, Adams FC, Van Grieken RE, The science of the total environment 91, 251 (1990). http://doi.org/10.1016/0048-9697(90)90302-B
Abstract: Air particulate samples were collected at Chapiquiña near Arica (Chile) with a six-stage cascade impactor for about 17-day periods during a 31 month interval. Sixteen elements were determined by energy dispersive X-ray fluorescence analysis, and the elemental concentrations were subjected to principal factor analysis. The variability with time of the coarse particles was described by two factors both related to soil dispersion, whereas the fine particle variations could be explained by a third factor related to marine influence. Enrichment factors were compared with those obtained in other remote continental areas, in particular those of air particulate matter sampled at Chacaltaya, Bolivia. Results point to a negligible anthropogenic influence.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90302-B
|
|
|
“Determination of sample thickness via scattered radiation in X-ray fluorescence spectrometry with filtered continuum excitation”. Araujo MF, van Espen P, Van Grieken R, X-ray spectrometry 19, 29 (1990). http://doi.org/10.1002/XRS.1300190107
Abstract: A semi-empirical approach is described for determining the mass per unit area of a sample being analysed. The method can be used to estimate the concentration of minor and trace elements in matrices containing a substantial amount of light elements. The procedure utilizes the coherently and incoherently scattered radiation induced in the sample by the filtered continuum radiation of a rhodium x-ray tube. The relationship between the intensity of the scattered radiation per unit mass and the average atomic number of the sample is established via calibration graphs, which can be applied for different x-ray tube voltages and for different primary beam filters. The overall procedure was validated by the analysis of several geological standards, deposited as thin slurries of unknown thickness either on Mylar foil or on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300190107
|
|
|
“The primary energy dependence of backscattered electron images up to 100 keV”. Geuens I, Nys B, Naudts J, Gijbels R, Jacob W, van Espen P, Scanning microscopy 5, 339 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Times cited: 3
|
|
|
“Spectrum evaluation”. van Espen P, Janssens K (1992).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Prediction of Mα/L&alpha, intensity ratios and the use in the spectra evaluation”. Trincavelli J, Montoro S, Van Grieken R, van Espen P, (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Size-differentiated composition of aerosols in Khartoum, Sudan”. Eltayeb MAH, van Espen PJ, Cafmeyer J, Van Grieken RE, Maenhaut W, The science of the total environment 120, 281 (1992). http://doi.org/10.1016/0048-9697(92)90062-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0048-9697(92)90062-W
|
|
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
|
|
“Studying aerosol samples by non-linear mapping of electron probe microanalysis data”. Treiger B, van Malderen H, Bondarenko I, van Espen P, Van Grieken R, Analytica chimica acta 284, 119 (1993). http://doi.org/10.1016/0003-2670(93)80014-C
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0003-2670(93)80014-C
|
|
|
“M\alpha/L\alpha intensity ratios for Ta, W, Pt, Au, Pb and Bi for electron energies in the 11-40 keV range”. Trincavelli J, Montoro S, van Espen P, Van Grieken R, X-ray spectrometry 22, 372 (1993). http://doi.org/10.1002/XRS.1300220510
Abstract: Both energy- and wavelength-dispersive systems were used to obtain Malpha/Lalpha intensity ratios for Ta, W, Pt, Au, Pb and Bi at various overvoltages. A table of these ratios corrected for matrix absorption and detector efficiency is presented, in addition to an interpolatory function of Malpha/Lalpha generated ratios vs. overvoltage, for each element. In addition, three different ZAF correction models were used to predict both detected and generated ratios. Finally, experimental Mbeta/Malpha ratios measured at different overvoltages are presented for the six elements considered.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220510
|
|
|
“Analysis of X-ray spectra by iterative least squares (AXIL): new developments”. Vekemans B, Janssens K, Vincze L, Adams F, van Espen P, X-ray spectrometry 23, 278 (1994). http://doi.org/10.1002/XRS.1300230609
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300230609
|
|
|
“Classification of coal mine dust particles through fuzzy clustering of their energy-dispersive electron microprobe X-ray spectra”. Bondarenko I, van Espen P, Treiger B, Van Grieken R, Adams F, Microbeam analysis 3, 33 (1994)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Classification of mineral particles by nonlinear mapping of electron microprobe energy-dispersive X-ray spectra”. Treiger B, Bondarenko I, van Espen P, Van Grieken R, Adams F, The analyst 119, 971 (1994). http://doi.org/10.1039/AN9941900971
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1039/AN9941900971
|
|
|
“Fractal dimensional classification of aerosol particles by computer-controlled scanning electron microscopy”. Kindratenko VV, van Espen PJM, Treiger BA, Van Grieken RE, Environmental science and technology 28, 2197 (1994). http://doi.org/10.1021/ES00061A031
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1021/ES00061A031
|
|
|
“Non-linear mapping of microbeam proton-induced X-ray emission data for source identification of North Sea aerosols”. Treiger B, Injuk J, Bondarenko I, van Espen P, Van Grieken R, Breitenbach L, Wätjen U, Spectrochimica acta: part B : atomic spectroscopy 49, 345 (1994). http://doi.org/10.1016/0584-8547(94)80029-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0584-8547(94)80029-4
|
|
|
“IDAS: a new Windows based software for multivariate analysis of atmospheric aerosol composition data bases”. Bondarenko I, Treiger B, Van Grieken R, van Espen P page 308 (1995).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Quantitative surface analysis of silver halide microcrystals using scanning ion microprobe and scanning Auger microprobe”. Janssens G, Geuens I, de Keyzer R, van Espen P, Gijbels R, Hubin A, Terryn H, Vereecken J Wiley, Chichester, page 161 (1996).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
|
|
|
“Study of quasi-fractal many-particle-systems and percolation networks by zero-loss spectroscopic imaging, electron energy-loss spectroscopy and digital image analysis”. Oleshko V, Kindratenko V, Gijbels R, van Espen P, Jacob W, Mikrochimica acta: supplementum 13, 443 (1996)
Abstract: Submicron colloidal Ag particles and nano-sized filaments forming a statistical percolation network during ''in situ'' development of double structure tabular microcrystals of AgRr(I) emulsions have been studied by electron energy-loss spectroscopy and zero-loss electron spectroscopic imaging (EELS/ZLESI). Image analysis has shown that random quasi-fractal clusters were formed in the colloid. ZLESI has been applied to characterise the morphology and defect structure of aggregated particles and filaments. Their energy-loss spectra revealed plasmon excitations and interband 4d electron transitions between 4-32 eV energy-loss. To study the cluster structure and its relation to the physical properties, fractal analysis including estimations of cluster fractal dimensions and of density autocorrelation functions has been performed. Mechanisms of fractal aggregation based on known models of diffusion limited aggregation, cluster-cluster aggregation and percolation are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
|
|
|
“Accurate evaluation of \mu-PIXE and \mu-XRF spectral data through iterative least squares fitting”. Janssens K, Vekemans B, Adams F, van Espen P, Mutsaers P, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms
T2 –, 7th International Conference on Particle Induced X-ray Emission and Its Analytical Applications, MAY 26-30, 1995, Abano Terme, Italy 109, 179 (1996). http://doi.org/10.1016/0168-583X(95)01211-7
Abstract: The integration of the nonlinear least squares X-ray spectrum evaluation progam AXIL. into a mu-PIXE and a mu-XRF setup is discussed. The use of the software when procesing data sets derived from biological and geological samples is described.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0168-583X(95)01211-7
|
|