“Similarities and differences between direct current and radio-frequency glow discharges: a mathematical simulation”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 1191 (2000). http://doi.org/10.1039/b000519n
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 25
DOI: 10.1039/b000519n
|
“Hybrid Monte Carlo-fluid model for a microsecond pulsed glow discharge”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 895 (2000). http://doi.org/10.1039/b003398g
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/b003398g
|
“Unveiling the composition of sulphur sensitization specks by their interactions with TAI”. Charlier E, van Doorselaer M, Gijbels R, de Keyzer R, Geuens I, Journal Of Imaging Science And Technology 44, 235 (2000)
Abstract: A two-step process for the formation of sensitivity centers different from earlier described two-step processes was found for sulfur sensitized emulsions. After deposition of sulfur in the first step, it was found that the second step does not consist of rearrangement of sulfur over the surface, but of the supply of silver interstitial ions towards the deposited sulfur clusters. The two processes could be separated by adsorbing and desorbing TAI (4-hydroxy-1, 3,3a, 7-tetraazaindene) at/from the silver halide surface. When 1.5 mmol TAI/mol Ag is added before the sulfur reaction, the silver interstitials are immobilized but sulfur still can be deposited at the same level. By lowering the pH to 2.50 after this sulfur reaction, TAI is desorbed from the surface and the released interstitials then cause a restoration of the properties of a sulfur system without TAI. These effects could be demonstrated via diffuse reflectance spectroscopy (DRS), sensitometry and dielectric loss measurements. We could also confirm the isolation of silver sulfide clusters by TAI from other chemicals in the solution, by adsorption of TAI on the clusters.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 0.348
Times cited: 16
|
“Calculation of gas heating in direct current argon glow discharges”. Bogaerts A, Gijbels R, Serikov VV, Journal of applied physics 87, 8334 (2000). http://doi.org/10.1063/1.373545
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 63
DOI: 10.1063/1.373545
|
“Evaluation of time-of-flight secondary ion mass spectrometry for metal contamination monitoring on wafer surfaces”. de Witte H, de Gendt S, Douglas M, Conard T, Kenis K, Mertens PW, Vandervorst W, Gijbels R, Journal of the electrochemical society 147, 13 (2000). http://doi.org/10.1149/1.1393457
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.259
Times cited: 14
DOI: 10.1149/1.1393457
|
“Behavior of the sputtered copper atoms, ions and excited species in a radio-frequency and direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 55, 279 (2000). http://doi.org/10.1016/S0584-8547(00)00142-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 17
DOI: 10.1016/S0584-8547(00)00142-7
|
“Description of the argon-excited levels in a radio-frequency and direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 55, 263 (2000). http://doi.org/10.1016/S0584-8547(00)00143-9
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 24
DOI: 10.1016/S0584-8547(00)00143-9
|
“Effects of adding hydrogen to an argon glow discharge: overview of relevant processes and some qualitative explanations”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 441 (2000). http://doi.org/10.1039/a909779a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 58
DOI: 10.1039/a909779a
|
“Molecular information in static SIMS for the speciation of inorganic compounds”. van Ham R, Adriaens A, van Vaeck L, Gijbels R, Adams F, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 161/163, 245 (2000). http://doi.org/10.1016/S0168-583X(99)00750-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.109
Times cited: 19
DOI: 10.1016/S0168-583X(99)00750-8
|
“Spatial behavior of energy relaxation of electrons in capacitively coupled discharges: comparison between Ar and SiH4”. Yan M, Bogaerts A, Gijbels R, Goedheer WJ, Journal of applied physics 87, 3628 (2000). http://doi.org/10.1063/1.372392
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 14
DOI: 10.1063/1.372392
|
“Electron Boltzmann kinetic equation averaged over fast electron bouncing and pitch-angle scattering for fast modeling of electron cyclotron resonance discharge”. Kaganovich I, Misina M, Berezhnoi S, Gijbels R, Physical review : E : statistical, nonlinear, and soft matter physics 61, 1875 (2000). http://doi.org/10.1103/PhysRevE.61.1875
Abstract: The electron distribution function (EDF) in an electron cyclotron resonance (ECR) discharge is far from Maxwellian. The self-consistent simulation of ECR discharges requires a calculation of the EDF on every magnetic line for various ion density profiles. The straightforward self-consistent simulation of ECR discharges using the Monte Carlo technique for the EDF calculation is very computer time expensive, since the electron and ion time scales are very different. An electron Boltzmann kinetic equation averaged over the fast electron bouncing and pitch-angle scattering was derived in order to develop an effective and operative tool for the fast modeling (FM) of low-pressure ECR discharges. An analytical solution for the EDF in a loss cone was derived. To check the validity of the FM, one-dimensional (in coordinate) and two-dimensional (in velocity) Monte Carlo simulation codes were developed. The validity of the fast modeling method is proved by comparison with the Monte Carlo simulations. The complete system of equations for FM is presented and ready for use in a comprehensive study of ECR discharges. The variations of plasma density and of wall and sheath potentials are analyzed by solving a self-consistent set of equations for the EDF.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 31
DOI: 10.1103/PhysRevE.61.1875
|
“Monte Carlo model for the argon ions and fast argon atoms in a radio-frequency discharge”. Bogaerts A, Gijbels R, IEEE transactions on plasma science 27, 1406 (1999). http://doi.org/10.1109/27.799819
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 15
DOI: 10.1109/27.799819
|
“Semianalytical description of nonlocal secondary electrons in a radio-frequency capacitively coupled plasma at intermediate pressures”. Berezhnoi S, Kaganovich I, Misina M, Bogaerts A, Gijbels R, IEEE transactions plasma science 27, 1339 (1999). http://doi.org/10.1109/27.799810
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 7
DOI: 10.1109/27.799810
|
“Analytical electron microscopy of silver halide photographic systems”. Oleshko VP, Gijbels RH, Jacob WA, Micron 31, 55 (2000). http://doi.org/10.1016/S0968-4328(99)00055-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.98
Times cited: 8
DOI: 10.1016/S0968-4328(99)00055-4
|
“The glow discharge: an exciting plasma”. Bogaerts A, Journal of analytical atomic spectrometry 14, 1375 (1999). http://doi.org/10.1039/a900772e
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 29
DOI: 10.1039/a900772e
|
“Hybrid modeling of a capacitively coupled radio frequency glow discharge in argon: combined Monte Carlo and fluid model”. Bogaerts A, Gijbels R, Goedheer W, Japanese journal of applied physics 38, 4404 (1999). http://doi.org/10.1143/JJAP.38.4404
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.384
Times cited: 45
DOI: 10.1143/JJAP.38.4404
|
“Role of Ar2+ and Ar+2 ions in a direct current argon glow discharge: a numerical description”. Bogaerts A, Gijbels R, Journal of applied physics 86, 4124 (1999). http://doi.org/10.1063/1.371337
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 50
DOI: 10.1063/1.371337
|
“Quantitative secondary ion mass spectrometry depth profiling of surface layers of cubic silver halide microcrystals”. Verlinden G, Gijbels R, Geuens I, Journal of the American Society for Mass Spectrometry 10, 1016 (1999). http://doi.org/10.1016/S1044-0305(99)00064-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.786
Times cited: 4
DOI: 10.1016/S1044-0305(99)00064-1
|
“Comparison between a radio-frequency and direct current glow discharge in argon by a hybrid Monte Carlo-fluid model for electrons, argon ions and fast argon atoms”. Bogaerts A, Gijbels R, Goedheer W, Spectrochimica acta: part B : atomic spectroscopy 54, 1335 (1999). http://doi.org/10.1016/S0584-8547(99)00080-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 11
DOI: 10.1016/S0584-8547(99)00080-4
|
“Static secondary ion mass spectrometry (S-SIMS): part 1: methodology and structural interpretation”. van Vaeck L, Adriaens A, Gijbels R, Mass spectrometry reviews 18, 1 (1999)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 9.373
Times cited: 112
|
“Capabilities of TOF-SIMS to study the influence of different oxidation conditions on metal contamination redistribution”. de Witte H, de Gendt S, Douglas M, Conard T, Kenis K, Mertens PW, Vandervorst W, Gijbels R s.n., Leuven, page 147 (1999).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Modeling of ionization of argon in an analytical capacitively coupled radio-frequency glow discharge”. Bogaerts A, Yan M, Gijbels R, Goedheer W, Journal of applied physics 86, 2990 (1999). http://doi.org/10.1063/1.371159
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 18
DOI: 10.1063/1.371159
|
“New developments and applications in GDMS”. Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 364, 367 (1999). http://doi.org/10.1007/s002160051352
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 17
DOI: 10.1007/s002160051352
|
“Investigation of the electron distribution functions in low pressure electron cyclotron resonance discharges”. Kaganovich I, Misina M, Bogaerts A, Gijbels R Kluwer Academic, Dordrecht, page 543 (1999).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Modelling of radio frequency capacitively coupled plasma at intermediate pressures”. Berezhnoi S, Kaganovich I, Bogaerts A, Gijbels R Kluwer Academic, Dordrecht, page 525 (1999).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“XPS and TOFSIMS studies of shallow Si/Si1-xGex/Si layers”. Conard T, de Witte H, Loo R, Verheyen P, Vandervorst W, Caymax M, Gijbels R, Thin solid films : an international journal on the science and technology of thin and thick films 343/344, 583 (1999). http://doi.org/10.1016/S0040-6090(99)00122-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.879
Times cited: 1
DOI: 10.1016/S0040-6090(99)00122-4
|
“Comprehensive modelling network for dc glow discharges in argon”. Bogaerts A, Plasma sources science and technology 8, 210 (1999). http://doi.org/10.1088/0963-0252/8/2/003
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 27
DOI: 10.1088/0963-0252/8/2/003
|
“Structural and analytical characterization of Ag(Br,I) nanocrystals by cryo-AEM techniques”. Oleshko VP, van Daele A, Gijbels RH, Jacob WA, Journal of nanostructured materials 10, 1225 (1998). http://doi.org/10.1016/S0965-9773(99)00003-3
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 5
DOI: 10.1016/S0965-9773(99)00003-3
|
“Characterization of AgxAuy nano particles by TEM and STEM”. de Vyt A, Gijbels R, Davock H, van Roost C, Geuens I, Journal of analytical atomic spectrometry 14, 499 (1999). http://doi.org/10.1039/a807695b
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 2
DOI: 10.1039/a807695b
|
“Surface analysis of halide distributions in complex AgX microcrystals by imaging time-of-flight SIMS (TOF-SIMS)”. Verlinden G, Gijbels R, Geuens I, de Keyzer R, Journal of analytical atomic spectrometry 14, 429 (1999). http://doi.org/10.1039/a807276k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 10
DOI: 10.1039/a807276k
|