“Hydrogen addition to an argon glow discharge: a numerical simulation”. Bogaerts A, Journal of analytical atomic spectrometry 17, 768 (2002). http://doi.org/10.1039/b200025c
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 48
DOI: 10.1039/b200025c
|
“Effect of small amounts of hydrogen added to argon glow discharges: hybrid Monte-Carlo-fluid model”. Bogaerts A, Gijbels R, Physical review : E : statistical, nonlinear, and soft matter physics 65, 056402 (2002). http://doi.org/10.1103/PhysRevE.65.056402
Abstract: A hybrid Monte Carlofluid modeling network is developed for an argon-hydrogen mixture, to predict the effect of small amounts of hydrogen added to a dc argon glow discharge. The species considered in the model include the Ar gas atoms, electrons, Ar+ ions and fast Ar atoms, ArH+, H+, H+2 and H+3 ions, and H atoms and H2 molecules, as well as Ar metastable atoms, sputtered Cu atoms, and the corresponding Cu+ ions. Sixty-five reactions between these species are incorporated in the model. The effect of hydrogen on various calculation results is investigated, such as the species densities, the relative role of different production and loss processes for the various species, the cathode sputtering rate and contributions by different bombarding species, and the dissociation degree of H2 and the ionization degree of Ar and Cu. The calculation results are presented and discussed for 1% H2 addition, and comparison is also made with a pure argon discharge and with only 0.1% H2 addition.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 33
DOI: 10.1103/PhysRevE.65.056402
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 74, 2691 (2002). http://doi.org/10.1021/ac020190r
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 18
DOI: 10.1021/ac020190r
|
“Evolution of charged particle densities after laser-induced photodetachment in a strongly electronegative RF discharge”. Yan M, Bogaerts A, Gijbels R, IEEE transactions on plasma science 30, 132 (2002). http://doi.org/10.1109/TPS.2002.1003959
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
DOI: 10.1109/TPS.2002.1003959
|
“Gas discharge plasmas and their applications”. Bogaerts A, Neyts E, Gijbels R, van der Mullen J, Spectrochimica acta: part B : atomic spectroscopy 57, 609 (2002). http://doi.org/10.1016/S0584-8547(01)00406-2
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 462
DOI: 10.1016/S0584-8547(01)00406-2
|
“Comparison of a one-dimensional particle-in-cell-Monte Carlo model and a one-dimensional fluid model for a CH4/H2 capacitively coupled radio frequency discharge”. Ivanov V, Proshina O, Rakhimova T, Rakhimov A, Herrebout D, Bogaerts A, Journal of applied physics 91, 6296 (2002). http://doi.org/10.1063/1.1461895
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 26
DOI: 10.1063/1.1461895
|
“Observation of Sb203 nanocrystals in SiO2 after Sb ion implantation”. Ignatova VA, Lebedev OI, Wätjen U, van Vaeck L, van Landuyt J, Gijbels R, Adams F, Microchimica acta 139, 77 (2002). http://doi.org/10.1007/s006040200043
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.58
Times cited: 3
DOI: 10.1007/s006040200043
|
“Can plasma spectrochemistry assist in improving the accuracy of chemical analysis?”.Adams F, Adriaens A, Bogaerts A, Analytica chimica acta 456, 63 (2002). http://doi.org/10.1016/S0003-2670(02)00010-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.95
Times cited: 6
DOI: 10.1016/S0003-2670(02)00010-7
|
“Hybrid model for a cylindrical hollow cathode glow discharge and comparison with experiments”. Baguer N, Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 57, 311 (2002). http://doi.org/10.1016/S0584-8547(01)00385-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 31
DOI: 10.1016/S0584-8547(01)00385-8
|
“Electron anisotropic scattering in gases: a formula for Monte Carlo simulations”. Okhrimovskyy A, Bogaerts A, Gijbels R, Physical review : E : statistical, nonlinear, and soft matter physics 65, 037402 (2002). http://doi.org/10.1103/PhysRevE.65.037402
Abstract: The purpose of this Brief Report is to point out the mistake in a formula for anisotropic electron scattering, previously published in Phys. Rev. A 41, 1112 (1990), which is widely used in Monte Carlo models of gas discharges. Anisotropic electron scattering is investigated based on the screened Coulomb potential between electrons and neutral atoms. The approach is also applied for electron scattering by nonpolar neutral molecules. Differential cross sections for electron scattering by Ar, N2, and CH4 are constructed on the basis of momentum and integrated cross sections. The formula derived in this paper is useful for Monte Carlo simulations of gas discharges.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 57
DOI: 10.1103/PhysRevE.65.037402
|
“The ion- and atom-induced secondary electron emission yield: numerical study for the effect of clean and dirty cathode surfaces”. Bogaerts A, Gijbels R, Plasma sources science and technology 11, 27 (2002). http://doi.org/10.1088/0963-0252/11/1/303
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 51
DOI: 10.1088/0963-0252/11/1/303
|
“Comparison of modeling calculations with experimental results for rf glow discharge optical emission spectrometry”. Bogaerts A, Wilken L, Hoffmann V, Gijbels R, Wetzig K, Spectrochimica acta: part B : atomic spectroscopy 57, 109 (2002). http://doi.org/10.1016/S0584-8547(01)00357-3
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 14
DOI: 10.1016/S0584-8547(01)00357-3
|
“Local and fast relaxation phenomena after laser-induced photodetachment in a strongly electronegative rf discharge”. Yan M, Bogaerts A, Gijbels R, Goedheer WJ, Physical review : E : statistical, nonlinear, and soft matter physics 65, 016408 (2002). http://doi.org/10.1103/PhysRevE.65.016408
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 2
DOI: 10.1103/PhysRevE.65.016408
|
“Exchange of fluorinated cyanine dyes between different types of silver halide microcrystals studied by imaging time-of-flight secondary ion mass spectrometry”. Lenaerts J, Verlinden G, van Vaeck L, Gijbels R, Geuens I, Callant P, Langmuir 17, 7332 (2001). http://doi.org/10.1021/la010862t
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.833
Times cited: 8
DOI: 10.1021/la010862t
|
“Design and development of a new program for data processing of mass spectra acquired by means of a high-resolution double-focusing glow-discharge mass spectrometer”. Robben J, Dufour D, Gijbels R, Fresenius' journal of analytical chemistry 370, 663 (2001). http://doi.org/10.1007/s002160100881
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 2
DOI: 10.1007/s002160100881
|
“Modeling of the sputtering process of cubic silver halide microcrystals and its relevance in depth profiling by secondary ion-mass spectrometry (SIMS)”. Lenaerts J, Verlinden G, Ignatova VA, van Vaeck L, Gijbels R, Geuens I, Fresenius' journal of analytical chemistry 370, 654 (2001). http://doi.org/10.1007/s002160100880
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 3
DOI: 10.1007/s002160100880
|
“Improved hybrid Monte Carlo-fluid model for the electrical characteristics in an analytical radiofrequency glow discharge in argon”. Bogaerts A, Gijbels R, Goedheer W, Journal of analytical atomic spectrometry 16, 750 (2001). http://doi.org/10.1039/b103768b
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 11
DOI: 10.1039/b103768b
|
“Comparison of modeling calculations with experimental results for direct current glow discharge optical emission spectrometry”. Bogaerts A, Wilken L, Hoffmann V, Gijbels R, Wetzig K, Spectrochimica acta: part B : atomic spectroscopy 56, 551 (2001). http://doi.org/10.1016/S0584-8547(01)00220-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 16
DOI: 10.1016/S0584-8547(01)00220-8
|
“1D fluid model for an rf methane plasma of interest in deposition of diamond-like carbon layers”. Herrebout D, Bogaerts A, Yan M, Goedheer W, Dekempeneer E, Gijbels R, Journal of applied physics 90, 570 (2001). http://doi.org/10.1063/1.1378059
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 83
DOI: 10.1063/1.1378059
|
“Modeling of a microsecond pulsed glow discharge: behavior of the argon excited levels and of the sputtered copper atoms and ions”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 16, 239 (2001). http://doi.org/10.1039/b009289o
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 36
DOI: 10.1039/b009289o
|
“Modeling of bombardment induced oxidation of silicon”. de Witte H, Vandervorst W, Gijbels R, Journal of applied physics 89, 3001 (2001). http://doi.org/10.1063/1.1344581
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 16
DOI: 10.1063/1.1344581
|
“Kinetic modeling of relaxation phenomena after photodetachment in a rf electronegative SiH4 discharge”. Yan M, Bogaerts A, Gijbels R, Physical review : E : statistical physics, plasmas, fluids, and related interdisciplinary topics 63 (2001). http://doi.org/10.1103/PhysRevE.63.026405
Abstract: The global relaxation process after pulsed laser induced photodetachment in a rf electronegative SIH4 discharge is studied by a self-consistent kinetic one-dimensional particle-in-cell-Monte Carlo model. Our results reveal a comprehensive physical picture of the relaxation process, including the main plasma variables, after a perturbation up to the full recovery of the steady state. A strong influence of the photodetachment on the discharge is found, which results from an increase of the electron density, leading to a weaker bulk field, and hence to a drop in the high energy tail of the electron energy distribution function (EEDF), a reduction of the reaction rates of electron impact attachment and ionization, and a subsequent decrease of the positive and negative ion densities. All the plasma quantities related to electrons recover synchronously. The recovery time of the ion densities is about 1-2 orders of magnitude longer than that of the electrons due to different recovery mechanisms. The modeled behavior of all the charged particles agrees very well with experimental results from the literature. In addition, our work clarifies some unclear processes assumed in the literature, such as the relaxation of the EEDF, the evolution of the electric field, and the recovery of negative ions.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 4
DOI: 10.1103/PhysRevE.63.026405
|
“SIMS/TOF-SIMS study of microparticles: surface analysis, imaging and quantification”. Gijbels R, Verlinden G, Geuens I London Institute of Physics, Bristol, page 331 (2000).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Modeling network for argon glow discharges: the output cannot be better than the input”. Bogaerts A, Gijbels R American Institute of Physics, Melville, N.Y., page 49 (2000).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 1
|
“Simulation of plasma processes in plasma assisted CVD reactors”. Herrebout D, Bogaerts A, Goedheer W, Dekempeneer E, Gijbels R, , 213 (1999)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“A self-consistent mathematical model of a hollow cathode glow discharge”. Baguer N, Bogaerts A, Gijbels R, , 157 (1999)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“SIMS analysis of oxynitrides: evidence for nitrogen diffusion induced by oxygen flooding”. de Witte H, Conard T, Vandervorst W, Gijbels R, Surface and interface analysis 29, 761 (2000). http://doi.org/10.1002/1096-9918(200011)29:11<761::AID-SIA926>3.0.CO;2-F
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.132
Times cited: 4
DOI: 10.1002/1096-9918(200011)29:11<761::AID-SIA926>3.0.CO;2-F
|
“Electron energy distribution function in capacitively coupled RF discharges: differences between electropositive Ar and electronegative SiH4 discharges”. Yan M, Bogaerts A, Goedheer WJ, Gijbels R, Plasma sources science and technology 9, 583 (2000). http://doi.org/10.1088/0963-0252/9/4/314
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 21
DOI: 10.1088/0963-0252/9/4/314
|
“A new electrostatic transfer line for improved transmission in Fourier transform laser microprobe mass spectrometry with external ion source”. van Vaeck L, van Espen P, Gijbels R, Baykut G, Laukien FH, European mass spectrometry 6, 277 (2000). http://doi.org/10.1255/ejms.342
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Times cited: 10
DOI: 10.1255/ejms.342
|
“Comparison of calculated and measured optical emission intensities in a direct current argon-copper glow discharge”. Bogaerts A, Donko Z, Kutasi K, Bano G, Pinhao N, Pinheiro M, Spectrochimica acta: part B : atomic spectroscopy 55, 1465 (2000). http://doi.org/10.1016/S0584-8547(00)00253-6
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 33
DOI: 10.1016/S0584-8547(00)00253-6
|