|
“Patterns of damage in igneous and sedimentary rocks under conditions simulating sea-salt weathering”. Cardell C, Rivas T, Mosquera MJ, Birginie JM, Moropoulou A, Prieto B, Silva B, Van Grieken R, Earth surface processes and landforms 28, 1 (2003). http://doi.org/10.1002/ESP.408
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/ESP.408
|
|
|
“Characteristics of atomic absorption calibration curves with the transversely heated graphite furnace”. Bencs L, Szakács O, Szoboszlai N, Ajtony Z, Bozsai G, Journal of analytical atomic spectrometry 18, 105 (2003). http://doi.org/10.1039/B208198A
Abstract: Calibration curves with two quasi-linear sections ("double sloping'') were observed for the medium volatile elements, Cr and Cu, with the use of a SIMAA 6000 graphite furnace atomic absorption spectrometer under interrupted internal gas flow conditions. If a standard transversally heated graphite atomizer (THGA) tube was shortened by 0.5 mm at both of its ends, (i.e. the gaps were enlarged between graphite furnace housing and tube ends), a stronger declination of the calibration curves resulted. Elements with fairly high diffusion coefficients (>5.8 cm(2) s(-1)) and with short appearance time of their transients (<0.6 s), such as Cr and Cu, have shown the most characteristic sensitivity drop towards higher concentrations. This anomalous feature could be eliminated in three different ways; (1) by applying end-capped THGA tubes, (2) using mini-flow (50 cm(3) min(-1)) conditions during the atomization stage, and (3) by adding Pd-Mg chemical modifier. For the low volatile Mo and V, the calibration curves had no irregular shape. For Ag, Co, Cr, Cu, Mn and Ni, the mini-flow settings improved the linearity of the calibration curves and extended the upper limit of the linear calibration range by a factor of 1.5-2.0. The irregular characteristic of the analytical curves was interpreted as an increased vapour loss at higher analyte concentrations through the opened ends of the standard THGA tubes. This vapour loss was associated with the significantly diverse expulsion velocities of atoms, caused by the difference in temperature and concentration gradients, when evaporating amounts of analytes with more than one order of magnitude difference.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B208198A
|
|
|
“Trace analysis of benzene, toluene, ethylbenzene and xylene isomers in environmental samples by low-pressure gas chromatography-ion trap mass spectrometry”. Joos PE, Godoi AFL, de Jong R, de Zeeuw J, Van Grieken R, Journal of chromatography: A: bibliography section 985, 191 (2003). http://doi.org/10.1016/S0021-9673(02)01843-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0021-9673(02)01843-5
|
|
|
“The processes dominating Ca dissolution of limestone when exposed to ambient atmospheric conditions as determined by comparing dissolution models”. Cardell Fernandez C, Cardell-Fernandez C, Vleugels G, Torfs K, Van Grieken R, Environmental geology 43, 160 (2002). http://doi.org/10.1007/S00254-002-0640-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00254-002-0640-X
|
|
|
“Oxidation states of uranium in DU particles from Kosovo”. Salbu B, Janssens K, Lind OC, Proost K, Danesi PR, Journal of environmental radioactivity 64, 167 (2003). http://doi.org/10.1016/S0265-931X(02)00047-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.31
DOI: 10.1016/S0265-931X(02)00047-4
|
|
|
“Single-particle characterization of urban aerosol particles collected in three Korean cities using low-Z electron probe x-ray microanalysis”. Ro C-U, Kim H, Oh K-Y, Yea SK, Lee CB, Jang M, Van Grieken R, Environmental science and technology 36, 4770 (2002). http://doi.org/10.1021/ES025697Y
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES025697Y
|
|
|
“Applying digital image processing to SEM-EDX and BSE images to determine and quantify porosity and salts with depth in porous media”. Cardell C, Yebra A, Van Grieken RE, Microchimica acta 140, 9 (2002). http://doi.org/10.1007/S006040200063
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040200063
|
|
|
“Characterisation of particulate matter in the Royal Museum of Fine Arts, Antwerp, Belgium”. Gysels K, Deutsch F, Van Grieken R, Atmospheric environment : an international journal 36, 4103 (2002). http://doi.org/10.1016/S1352-2310(02)00229-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1352-2310(02)00229-7
|
|
|
“Material analysis methods applied to the study of ancient monuments, works of art and artefacts”. Delalieux F, Tsuji K, Wagatsuma K, Van Grieken R, Materials transactions 43, 2197 (2002). http://doi.org/10.2320/MATERTRANS.43.2197
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.2320/MATERTRANS.43.2197
|
|
|
“A Monte Carlo model for studying the microheterogeneity of trace elements in reference materials by means of synchrotron microscopic X-ray fluorescence”. Kempenaers L, Janssens K, Vincze L, Vekemans B, Somogyi A, Drakopoulos M, Simionovici AS, Adams F, Analytical chemistry 74, 5017 (2002). http://doi.org/10.1021/AC025662G
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 21
DOI: 10.1021/AC025662G
|
|
|
“Substrates with a periodic surface structure in grazing-exit X-ray microanalysis”. Bekshaev A, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 57, 865 (2002). http://doi.org/10.1016/S0584-8547(02)00019-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(02)00019-8
|
|
|
“Characterisation of wood combustion particles using electron probe microanalysis”. Osán J, Alföldy B, Török S, Van Grieken R, Atmospheric environment : an international journal 36, 2207 (2002). http://doi.org/10.1016/S1352-2310(02)00153-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1352-2310(02)00153-X
|
|
|
“X-ray spectrometry”. Szalóki I, Török SB, Injuk J, Van Grieken RE, Analytical chemistry 74, 2895 (2002). http://doi.org/10.1021/AC020241K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC020241K
|
|
|
“Damage functions and mechanism equations derived from limestone weathering in field exposure”. Delalieux F, Cardell-Fernandez C, Torfs K, Vleugels G, Van Grieken RE, Water, air and soil pollution 139, 75 (2002). http://doi.org/10.1023/A:1015827031669
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/A:1015827031669
|
|
|
“Airborne particles in the Miyagi Museum of Art in Sendai, Japan, studied by electron probe X-ray microanalysis and energy dispersive X-ray fluorescence analysis”. Injuk J, Osán J, Van Grieken R, Tsuji K, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 18, 561 (2002). http://doi.org/10.2116/ANALSCI.18.561
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.2116/ANALSCI.18.561
|
|
|
“Application of thin-window EPMA to environmental problems in Hungary”. Osán J, Kurunczi S, Török S, Worobiec A, Van Grieken R, Microchimica acta 139, 111 (2002). http://doi.org/10.1007/S006040200048
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040200048
|
|
|
“High-resolution X-ray fluorescence micro-tomography on single sediment particles”. Vincze L, Vekemans B, Szalóki I, Janssens K, Van Grieken R, Feng H, Jones KW, Adams F page 240 (2002).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 11
DOI: 10.1117/12.452865
|
|
|
“The colour of silver stained glass : analytical investigations carried out with XRF, SEM/EDX, TEM and IBA”. Jembrih-Simbürger D, Neelmeijer C, Schalm O, Fredrickx P, Schreiner M, De Vis K, Mäder M, Schryvers D, Caen J, Journal of analytical atomic spectrometry 17, 321 (2002). http://doi.org/10.1039/b111024c
Abstract: Glass treated on its surface with silver compounds and an aluminosilicate, such as ochre or clay, at higher temperatures (between 550 and 650 °C) accepts a wide variety of a yellow colour. It is the aim of this study to investigate the parameters of the manufacturing process affecting the final colour of silver stained glass and to correlate them with the final colour and colour intensity. Therefore, defined mixtures of ochre and a silver compound (AgCl, AgNO3, Ag2SO4, Ag3PO4, Ag2O) were prepared and applied on soda-lime glass. The firing process was modified within the range from 563 to 630 °C and glass samples were analysed after treatment with energy dispersive X-ray fluorescence analysis (EDXRF), scanning electron microscopy (SEM/EDX), transmission electron microscopy (TEM), as well as ion beam analysis (IBA) with an external beam. Within the scope of IBA simultaneous measurements using particle-induced X-ray emission (PIXE), particle-induced gamma-ray emission (PIGE), and Rutherford backscattering spectrometry (RBS) were carried out in order to obtain the thickness of the Ag-rich surface layer and the depth distribution of Ag. By means of TEM the microstructure of the silver particles was visualised. XRF results show that the lowest amount of Ag could be detected on glass samples treated with silver stain mixtures containing AgCl and Ag2O. A low kiln temperature (e.g. 563 °C) results in a higher silver concentration at the surface and lower penetration depths. Furthermore, the results obtained with SEM/EDX at cross-sections of the glass samples could be confirmed by PIXE, PIGE, RBS, and TEM.
Keywords: A1 Journal article; Art; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 42
DOI: 10.1039/b111024c
|
|
|
“X-ray analysis of riverbank sediment of the Tisza (Hungary): identification of particles from a mine pollution event”. Osán J, Kurunczi S, Török S, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 57, 413 (2002). http://doi.org/10.1016/S0584-8547(01)00405-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00405-0
|
|
|
“Sedimentation rate of the floodplain sediments of the Yamuna river basin (tributary of the river Ganges, India) by using <tex>210Pb</tex>, and <tex>137Cs</tex>, techniques”. Saxena DP, Joos P, Van Grieken R, Subramanian V, Journal of radioanalytical and nuclear chemistry 251, 399 (2002). http://doi.org/10.1023/A:1014821906600
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/A:1014821906600
|
|
|
“Suitability of polycapillary optics for focusing of monochromatic synchrotron radiation as used in trace level micro-XANES measurements”. Vincze L, Wei F, Proost K, Vekemans B, Janssens K, He Y, Yan Y, Falkenberg G, Journal of analytical atomic spectrometry 17, 177 (2002). http://doi.org/10.1039/B110210A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/B110210A
|
|
|
“Quantitative trace element analysis of individual fly ash particles by means of X-ray microfluorescence”. Vincze L, Somogyi A, Osán J, Vekemans B, Török S, Janssens K, Adams F, Analytical chemistry 74, 1128 (2002). http://doi.org/10.1021/AC010789B
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 44
DOI: 10.1021/AC010789B
|
|
|
“Characterisation of aerosol particles in the São Paulo Metropolitan Area”. de Miranda RM, de Fátima Andrade M, Worobiec A, Van Grieken R, Atmospheric environment : an international journal 36, 345 (2002). http://doi.org/10.1016/S1352-2310(01)00363-6
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1352-2310(01)00363-6
|
|
|
“Comparative material characterization of historical and industrial samples by using a compact micro-XRF spectrometer”. Bichlmeier S, Janssens K, Heckel J, Hoffmann P, Ortner HM, X-ray spectrometry 31, 87 (2002). http://doi.org/10.1002/XRS.563
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 12
DOI: 10.1002/XRS.563
|
|
|
“Performance of a new compact EDXRF spectrometer for aerosol analysis”. Samek L, Injuk J, van Espen P, Van Grieken R, X-ray spectrometry 31, 84 (2002). http://doi.org/10.1002/XRS.551
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.551
|
|
|
“Grazing-emission electron probe microanalysis of particles near the substrate edge”. Bekshaev A, de Hoog J, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 56, 2385 (2001). http://doi.org/10.1016/S0584-8547(01)00300-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00300-7
|
|
|
“Leaching of nutrients and trace metals from aerosol samples: a comparison between a re-circulation and an ultrasound system”. Eyckmans K, Zhang J, de Hoog J, Joos P, Van Grieken R, International journal of environmental analytical chemistry 80, 227 (2001). http://doi.org/10.1080/03067310108044372
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067310108044372
|
|
|
“Evaluation of energy-dispersive x-ray spectra of low-Z elements from electron-probe microanalysis of individual particles”. Osán J, de Hoog J, van Espen P, Szalóki I, Ro C-U, Van Grieken R, X-ray spectrometry 30, 419 (2001). http://doi.org/10.1002/XRS.523
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.523
|
|
|
“Application of chemometric methods for classification of atmospheric particles based on thin-window electron probe microanalysis data”. Osán J, de Hoog J, Worobiec A, Ro C-U, Oh K-Y, Szalóki I, Van Grieken R, Analytica chimica acta 446, 211 (2001)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Single-particle analysis of aerosols at Cheju Island, Korea, using low-Z electron probe X-ray microanalysis: a direct proof of nitrate formation from sea salts”. Ro C-U, Oh K-Y, Kim H, Kim YP, Lee CB, Kim K-H, Kang CH, Osán J, de Hoog J, Worobiec A, Van Grieken R, Environmental science and technology 35, 4487 (2001). http://doi.org/10.1021/ES0155231
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES0155231
|
|