|
“Interpretation of aerosol trace metal particle size distributions”. Johansson TB, Van Grieken RE, Winchester JW page 356 (1975).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Introduction: considering the role of X-ray spectrometry in chemical analysis and outlining the volume”. Van Grieken R page 1 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Investigation of individual particles and gaseous air pollutants in showcases”. Godoi RHM, Kontozova V, Godoi AFL, Van Grieken R page 147 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Invigorating the renaissance of single cell protein : safe opportunities for nutrient recovery and reuse as feed ingredient”. Sui Y, Alloul A, Muys M, Makyeme M, Coppens J, Verstraete W, Vlaeminck SE, , 12 p.
T2 (2016)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Its time to harvest : combining internal selection and flocculent external selection to maximize carbon capture efficiency”. Van Winckel T, Yapuwa H, Wett B, Sturm B, Vlaeminck SE, Al-Omari A, Murthy S, De Clippeleir H, , 3 p.
T2 (2017)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
van der Snickt G (2012) James Ensor's pigments studied by means of portable and synchrotron radiation-based X-ray techniques : evolution, context and degradation. 501 p
Keywords: Doctoral thesis; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“De kleine boerderij : twee bijzondere tuinkamers”. Vermander C, De Wael J, Gielis J, Groencontact 45, 14 (2019)
Keywords: A2 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Kultuurpatrimonium, zure regen en energie”. Van Grieken R, Fobe B, Energie en milieu: tijdschrift over energie en leefmilieu , 10 (1990)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Lamé-Gielis curves in biology and geometry”. Gielis J, Shi P, Beirinckx B, Caratelli D, Ricci PE, (2021)
Keywords: P3 Proceeding; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“LAMMA analysis of inorganic ammonium compounds in individual marine aerosol particles”. Otten P, Bruynseels, Van Grieken R, (1986)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“LAMMA : calibration and application to nephrotoxicology studies”. Verbueken A, Paulus G, Van de Vyver F, Verpooten G, de Broe M, Van Grieken R, (1983)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“LAMMA in nephrotoxicity studies”. Verbueken AH, Paulus GJ, Van de Vyver FL, Verpooten GA, Visser WJ, de Broe ME, Van Grieken RE, (1984)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“LAMMA-study of aerosol samples collected in the Amazon basin”. Bruynseels F, Artaxo P, Storms H, Van Grieken R page 355 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Hellemans K (2019) Laser ablation ICP-MS as a tool for surface analysis in comparison to other elemental analysis methods. 229 p
Abstract: Dit onderzoek presenteert een overzicht van de mogelijkheden van LA-ICP-MS als een techniek voor kwantitatieve analyse, bepalen van isotoopverhoudingen en elementaire beeldvorming. Hiervoor wordt de techniek zelf voorgesteld en worden de belangrijkste parameters die een invloed hebben op de kwaliteit van een LA-ICP-MS meting beschreven. Voor kwantitieve analyse worden de huidige calibratiestrategieën voor LA-ICP-MS toegelicht, zowel op het vlak van selectie en bereiding van standaarden als op het vlak van dataverwerking. Daarnaast werd een nieuwe calibratiestrategie voorgesteld, gebaseerd op een lineaire combinatie van standaarden. Een case study met de traditionele calibratiestrategie uit de literatuur werd uitgevoerd en vergeleken met data van SEM-EDX om een referentiekader te schetsen voor de performantie van de techniek. In een tweede case study werd onze nieuwe calibratiestrategie toegepast en werd er uitsluitend gebruik gemaakt van LA-ICP-MS, wat uitstekende resultaten opleverde. Met het oog op het bepalen van isotoopverhoudingen, werd er onderzocht wat de limieten zijn van het gebruik van een lage resolutie quadrupool massaspectrometer voor deze bepaling. Dit stelde ons in staat om de te verwachten accuraatheid en precisie in te schatten. De performantie bleek goed genoeg te zijn om weapon-grade plutonium te onderscheiden van global fall-out, zoals het werd aangetoond in de case study omtrent dit onderwerp. Uiteindelijk hebben we ook LA-ICP-MS geëvalueerd als een techniek voor elementaire beeldvorming, waarbij we tevens de meest courante multivariate data analyse hebben beschreven. Om de techniek te plaatsen tegenover andere elementaire technieken, werd een historisch verffragment geanalyseerd dat in het verleden reeds geanalyseerd was met SEM-EDX and μ-XRD. Op die manier konden we de resultaten accuraat vergelijken met de andere technieken.
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laser microprobe mass analysis : a review of applications in the life sciences”. Verbueken AH, Bruynseels FJ, Van Grieken RE, Biomedical mass spectrometry 12, 438 (1985). http://doi.org/10.1002/BMS.1200120903
Abstract: The characteristics and analytical utility of laser microprobe mass analysis (LAMMA) are described and evaluated, and a short history of this recent microanalytical technique is presented. A review of the areas of application of LAMMA and related laser microprobes is presented with special emphasis on applications in the life sciences.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200120903
|
|
|
van de Vijver FL, Verbueken AH, Van Grieken RE, de Broe ME, Visser WJ (1985) Laser microprobe mass analysis : a tool for evaluating histochemical staining of trace elements. 351–352
Keywords: L1 Letter to the editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis : characteristics and applications”. Van Grieken R, Verbueken A, Bruynseels F, Vandeputte D, Goossenaerts C, Leysen L, Otten P, Wouters L, (1987)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laser microprobe mass analysis (LAMMA) in nephrological investigations”. Verbueken AH, Van de Vyver FL, Paulus GJ, Visser WJ, Verpooten GA, de Broe ME, Van Grieken RE page 375 (1984).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis (LAMMA) of parathyroid glands from dialysis patients”. Verbueken AH, Van de Vyver FL, Nouwen EJ, Roels F, de Broe ME, Van Grieken RE page 443 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis (LAMMA) to study lead intoxication at the subcellular level”. Vandeputte DF, Verbueken AH, Jacob WA, Van Grieken RE, Acta pharmacologica et toxicologica 59, 617 (1986). http://doi.org/10.1111/J.1600-0773.1986.TB02840.X
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0773.1986.TB02840.X
|
|
|
“Laser microprobe mass analysis (LAMMA) to verify the aluminon staining of bone”. Verbueken AH, van de Vijver FL, Visser WJ, Van Grieken RE, de Broe ME, Stain technology 61, 287 (1986). http://doi.org/10.3109/10520298609109955
Abstract: Triammonium aurin tricarboxylate (aluminon) has been used to localize aluminum in 2 μm sections of undecalcified, methyl methacrylate embedded bone obtained from patients with terminal chronic renal failure. Aluminum appeared in four cases as bright red lines at the mineralized-bone boundary. In two cases, however, purplish lines were found and one patient showed red as well as purplish lines. Laser microprobe mass analysis (LAMMA) identified aluminum at the location of the red lines and both aluminum and iron at the purplish lines. Furthermore, both iron and aluminum were found in histiocytic bone marrow cells, which showed brownish aluminon staining. It appears that when aluminum and iron occur together, aluminon staining may yield aberrant results. This study shows that LAMMA can be used for the identification of elements sought by histochemical methods and thus permits the evaluation of their staining effects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.3109/10520298609109955
|
|
|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
|
|
“Laser microprobe mass spectrometry of platinum in dog kidney after cisplatin adminstration”. Verbueken AH, Van Grieken RE, Paulus GJ, Verpooten GA, de Broe ME, Biomedical mass spectrometry 11, 159 (1984). http://doi.org/10.1002/BMS.1200110404
Abstract: By means of laser microprobe mass analysis (LAMMA) platinum was detected in the renal proximal tubular cells of a dog that had been intravenously adminstered the antitumor drug cisplatin (5 mg per kg body weight). No definite subcellular localization of the heavy metal was obtained. Sample prparation and analytical features are examined to increase spatial resolution of analysis while maintaining sufficient detection efficiency. The LAMMA method is destructive, but the amount and type of evaporated material can readily be determined when using LAMMA in combination with transmission electron microscopy. Instrumental optimization and standardization of mass signals is possible by using platinum-loaded, ion chelating resin beads embedded and sectioned with the tissue.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/BMS.1200110404
|
|
|
“Lets settle together? Extending external selection from mainstream deammonification to high-rate activated sludge”. Van Winckel T, De Clippeleir H, Yapuwa H, Wett B, Bott C, Sturm B, Vlaeminck SE, Al-Omari A, Murthy S, , 13 p.
T2 (2016)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Localisation of lead and fluoride in cultured tooth germs by laser microprobe mass analysis (LAMMA)”. Vandeputte D, Ameloot P, Van Grieken R page 90 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Localisation of lead in tissues of poisoned rats by laser microprobe mass analysis (LAMMA)”. Vandeputte D, Verbueken A, Jacob W, de Broe M, Van Grieken R, (1986)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Localization of aluminum in tissues”. Verbueken AH, van de Vijver FL, Nouwen EJ, Van Grieken RE, de Broe ME, Contributions to nephrology 64, 124 (1988)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Localization of lead and fluoride in cultured tooth germs by laser microprobe mass analysis”. Vandeputte DF, Ameloot PC, Cleymaet R, Coomans D, Van Grieken RE, Biological trace element research 23, 133 (1990). http://doi.org/10.1007/BF02917184
Abstract: Trace elements can influence dental health, possibly by altering tooth resistance during preeruptive development. Therefore, it was investigated whether lead and fluoride would be incorporated into the calcifying matrices or the cellular parts of tooth germs in vitro. Using laser microprobe mass analysis, the localization of lead and fluoride was studied in the different layers or tooth germs that had been cultured in a medium to which PbCl2 of NaF had been added in different concentrations. Both elements could only be detected in the dentine layer. Hence, the enamel organ in the secretory stage of tooth development excludes lead and fluoride from the enamel, even when enamel formation by the ameloblasts is visibly disturbed. Furthermore, there seemed to be a process of saturation in the accumulation of lead and fluoride in the dentine.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02917184
|
|
|
“Localization of lead in cultured tooth germs by laser microprobe micro-analysis”. Ameloot PC, Vandeputte DF, Van Grieken RE, Coomans D, Proceedings of the Finnish Dental Society 83, 225 (1987)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Loss of particulate organic matter in estuaries as exemplified by the Ems and Gironde estuaries”. Eisma D, Bernard P, Boon JJ, Van Grieken R, Kalf J, Mook WG, Mitteilungen aus dem Geologisch-Paläontologischen Institut der Universität Hamburg 58, 397 (1985)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|