|
“Comparison of 3 dry deposition models applied to field-measurements in the Southern Bight of the North-Sea”. Rojas CM, Van Grieken RE, Laane RW, Atmospheric environment 27, 363 (1993). http://doi.org/10.1016/0960-1686(93)90110-K
Abstract: Dry deposition velocities have been calculated using three different approaches. Turbulent wind profile theory has been used to predict the drag coefficient, wind speed and friction velocity at 10 m height when the wind speed is measured at a higher altitude. The resulting parameters were introduced in a two-layer deposition model. The second approach was the well-known model of Slinn and Slinn (1980, Atmospheric Environment 14, 1013-1016), whereas the third corresponded to the model published by Williams (1982, Atmospheric Environment 16, 1933 1938). Results point to clear differences. However, in a field experiment carried out at the Southern Bight of the North Sea, all three approaches show relatively comparable results. The role played by the size distribution of atmospheric particulate matter is essential. In our case any of the three models could have given satisfactory outcomes taking into account the wide spread of the experimental results cited in the literature for the same airshed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(93)90110-K
|
|
|
“Dry and wet deposition fluxes of Cd, Cu, Pb, and Zn into the Southern Bight of the North Sea”. Rojas CM, Injuk J, Van Grieken R, Laane RW, Atmospheric environment: part A : general topics 27, 251 (1993). http://doi.org/10.1016/0960-1686(93)90355-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(93)90355-3
|
|
|
“Influence of Bridgman process conditions on microstructure and porosity of single crystal Ni-base superalloy CMSX-4”. Matuszewski K, Matysiak H, Jaroszewicz J, de Nolf W, Kubiak K, Kurzydlowski KJ, International journal of cast metals research 27, 329 (2014). http://doi.org/10.1179/1743133614Y.0000000112
Abstract: Synchrotron radiation micro-X-ray fluorescence and micro-X-ray diffraction analysis, micro-computed tomography and transmission electron microscopy were used to investigate the microstructure of turbine blades made of a second generation nickel based superalloy CMSX-4 manufactured by investment casting process via Bridgman technique. The dependence of microstructure on process parameters, among others, on the withdrawal rate was analysed. The results set the stage for optimising the microstructure of the blades in terms of their mechanical properties.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1179/1743133614Y.0000000112
|
|
|
“On the memory effect of limestone for air pollution”. Vleugels G, Dewolfs R, Van Grieken R, Atmospheric environment: part A : general topics 27, 1931 (1993). http://doi.org/10.1016/0960-1686(93)90298-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(93)90298-D
|
|
|
“An overview of wet deposition of micropollutants to the North Sea”. Struyf H, Van Grieken R, Atmospheric environment: part A : general topics 27, 2669 (1993). http://doi.org/10.1016/0960-1686(93)90036-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(93)90036-X
|
|
|
“NO2 verkeersmetingen in Vlaanderen door passieve bemonstering”. Potgieter-Vermaak S, Stranger M, Verlinden L, Roekens E, Van Grieken R, Die Suid-Afrikaanse tydskrif vir natuurwetenskap en tegnologie 27, 266 (2008)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
|
|
“A mobile instrument for in situ scanning macro-XRF investigation of historical paintings”. Alfeld M, Pedroso JV, van Hommes ME, van der Snickt G, Tauber G, Blaas J, Haschke M, Erler K, Dik J, Janssens K, Journal of analytical atomic spectrometry 28, 760 (2013). http://doi.org/10.1039/C3JA30341A
Abstract: Scanning macro-X-ray fluorescence analysis (MA-XRF) is rapidly being established as a technique for the investigation of historical paintings. The elemental distribution images acquired by this method allow for the visualization of hidden paint layers and thus provide insight into the artist's creative process and the painting's conservation history. Due to the lack of a dedicated, commercially available instrument the application of the technique was limited to a few groups that constructed their own instruments. We present the first commercially available XRF scanner for paintings, consisting of an X-ray tube mounted with a Silicon-Drift (SD) detector on a motorized stage to be moved in front of a painting. The scanner is capable of imaging the distribution of the main constituents of surface and sub-surface paint layers in an area of 80 by 60 square centimeters with dwell times below 10 ms and a lateral resolution below 100 mu m. The scanner features for a broad range of elements between Ti (Z = 22) and Mo (Z = 42) a count rate of more than 1000 counts per second (cps)?mass percent and detection limits of 100 ppm for measurements of 1 s duration. Next to a presentation of spectrometric figures of merit, the value of the technique is illustrated through a case study of a painting by Rembrandt's student Govert Flinck (1615-1660).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 106
DOI: 10.1039/C3JA30341A
|
|
|
“Large-volume injection combined with gas chromatography/isotope ratio mass spectrometry for the analysis of polycyclic aromatic hydrocarbons”. Buczyńska AJ, Geypens B, Van Grieken R, De Wael K, Rapid communications in mass spectrometry 28, 1 (2014). http://doi.org/10.1002/RCM.6769
Abstract: RATIONALE: Compound-specific stable isotope analyses of carbon require relatively large amounts of sample for reliable analyses. Commonly applied injections of 1 μL may thus be inefficient for samples with low concentrations of pollutants (e.g. air particulate matter) or when the amount of a sample is limited. METHODS: A Large-Volume Injection (LVI) method for carbon stable isotope ratio analysis of Polycyclic Aromatic Hydrocarbons (PAHs) was optimized in this study. Gas chromatography/combustion/isotope ratio mass spectrometry (GCCIRMS) and ion trap mass spectrometry (ITMS) were used for the determination of stable carbon isotope ratios and quantification of compounds, respectively. RESULTS: The optimized method resulted in very good reproducibility, even for the most volatile PAH, naphthalene, when a small amount of higher boiling co-solvent was used. No significant fractionation of isotope ratios could be seen and the recoveries of analytes were similar to or better than that of a splitless cold injection. CONCLUSIONS: Injection of 100 μL, instead of the commonly used 1 μL, increases the detection limit for PAHs significantly and/or simplifies the sample preparation step. Using our optimized method, stable carbon isotope ratios can be reliably measured in samples with concentrations of PAHs down to 0.050.1 ng μL1.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.998
Times cited: 5
DOI: 10.1002/RCM.6769
|
|
|
“Revealing hidden paint layers in oil paintings by means of scanning macro-XRF : a mock-up study based on Rembrandt's “An old man in military costume””. Alfeld M, de Nolf W, Cagno S, Janssens K, et al, Journal of analytical atomic spectrometry 28, 40 (2013). http://doi.org/10.1039/C2JA30119A
Abstract: Over the past several decades the oeuvre of Rembrandt has been the subject of extensive art historical and scientific investigations. One of the most striking features to emerge is his frequent re-use of canvases and panels. The painting An Old Man in Military Costume (78.PB.246), in the collection of the J. Paul Getty Museum, is an example of such a re-used panel. Conventional imaging techniques revealed the presence of a second portrait under the surface portrait, but the details of this hidden portrait have not yet been revealed. Vermilion (HgS) has been identified to have been used nearly exclusively in the flesh tones of the lower painting, suggesting that element-specific XRF imaging might successfully image the hidden portrait. To test this hypothesis, a full-scale mock-up of the painting was created, including a “free impression” of the hidden portrait, reproducing as closely as possible the pigments and paint stratigraphy of the original painting. XRF imaging of the mock-up painting was conducted using three different XRF imaging systems: a mobile X-ray tube based system and two synchrotron-based setups (one equipped with multiple SDDs and one equipped with a Maia detector). The sensitivity, limits of detection and imaging capabilities of each system under the chosen experimental conditions are evaluated and compared. The results indicate that an investigation of the original painting by this method would have an excellent chance of success.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/C2JA30119A
|
|
|
“Application of auxiliary signals in X-ray fluorescence and electron microprobe analysis for density evaluation”. Kuczumov A, Vekemans B, Schalm O, Vincze L, Dorriné, W, Gysels K, Van Grieken R, X-ray spectrometry 28, 282 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<282::AID-XRS352>3.0.CO;2-H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<282::AID-XRS352>3.0.CO;2-H
|
|
|
“Fractal dimensional classification of aerosol particles by computer-controlled scanning electron microscopy”. Kindratenko VV, van Espen PJM, Treiger BA, Van Grieken RE, Environmental science and technology 28, 2197 (1994). http://doi.org/10.1021/ES00061A031
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1021/ES00061A031
|
|
|
“Morphological and elemental characterization of leaf-deposited particulate matter from different source types : a microscopic investigation”. Castanheiro A, Wuyts K, Hofman J, Nuyts G, De Wael K, Samson R, Environmental Science And Pollution Research 28, 25716 (2021). http://doi.org/10.1007/S11356-021-12369-Z
Abstract: Particulate matter (PM) deposition on urban green enables the collection of particulate pollution from a diversity of contexts, and insight into the physico-chemical profiles of PM is key for identifying main polluting sources. This study reports on the morphological and elemental characterization of PM2-10 deposited on ivy leaves from five different environments (forest, rural, roadside, train, industry) in the region of Antwerp, Belgium. Ca. 40,000 leaf-deposited particles were thoroughly investigated by particle-based analysis using scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM/EDX) and their physico-chemical characteristics were explored for PM source apportionment purposes. The size distribution of all deposited particles was biased towards small-sized PM, with 32% of the particles smaller than 2.5 mu m (PM2.5) and median diameters of 2.80-3.09 mu m. The source type influenced both the particles' size and morphology (aspect ratio and shape), with roadside particles being overall the smallest in size and the most spherical. While forest and rural elemental profiles were associated with natural PM, the industry particles revealed the highest anthropogenic metal input. PM2-10 profiles for roadside and train sites were rather comparable and only distinguishable when evaluating the fine (2-2.5 mu m) and coarse (2.5-10 mu m) PM fractions separately, which enabled the identification of a larger contribution of combustion-derived particles (small, circular, Fe-enriched) at the roadside compared to the train. Random forest prediction model classified the source type correctly for 61-85% of the leaf-deposited PM. The still modest classification accuracy denotes the influence of regional background PM and demands for additional fingerprinting techniques to facilitate source apportionment. Nonetheless, the obtained results demonstrate the utility of leaf particle-based analysis to fingerprint and pinpoint source-specific PM, particularly when considering both the composition and size of leaf-deposited particles.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.741
DOI: 10.1007/S11356-021-12369-Z
|
|
|
“Patterns of damage in igneous and sedimentary rocks under conditions simulating sea-salt weathering”. Cardell C, Rivas T, Mosquera MJ, Birginie JM, Moropoulou A, Prieto B, Silva B, Van Grieken R, Earth surface processes and landforms 28, 1 (2003). http://doi.org/10.1002/ESP.408
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/ESP.408
|
|
|
“Progress in laboratory grazing emission X-ray fluorescence spectrometry”. Claes M, de Bokx P, Van Grieken R, X-ray spectrometry 28, 224 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
|
|
|
“Recent trends in quantitative aspects of microscopic X-ray fluorescence analysis”. Janssens K, de Nolf W, van der Snickt G, Vincze L, Vekemans B, Terzano R, Brenker FE, Trends in analytical chemistry 29, 464 (2010). http://doi.org/10.1016/J.TRAC.2010.03.003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.442
Times cited: 48
DOI: 10.1016/J.TRAC.2010.03.003
|
|
|
“Use of microscopic XRF for non-destructive analysis in art an archaeometry”. Janssens K, Vittiglio G, Deraedt I, Aerts A, Vekemans B, Vincze L, Wei F, de Ryck I, Schalm O, Adams F, Rindby A, Knöchel A, Simionovici AS, Snigirev A, X-ray spectrometry 29, 73 (2000). http://doi.org/10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
|
|
|
“Losses of metabolically incorporated selenium in common digestion procedures for biological material”. Robberecht HJ, Van Grieken RE, Van den Bosch PA, Deelstra H, vanden Berghe D, Talanta : the international journal of pure and applied analytical chemistry 29, 1025 (1982). http://doi.org/10.1016/0039-9140(82)80244-0
Abstract: Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80244-0
|
|
|
“Metal pollution and selenium distributions in soils and grass near a non-ferrous plant”. Robberecht H, Deelstra H, vanden Berghe D, Van Grieken R, The science of the total environment 29, 229 (1983). http://doi.org/10.1016/0048-9697(83)90093-1
Abstract: Multi-element analysis results of direct energy-dispersive X-ray fluorescence of soil samples taken in the vicinity of a non-ferrous plant in Antwerp are reported. High concentrations of Pb, Cu, Zn, As and Se are found in nearby residential areas, especially in top-soil layers. Selenium pollution appears not to be leached significantly to lower soil horizons, but it is available for uptake by rye-grass, in which toxic levels are found. Results are compared to literature data. Hydride generation atomic absorption spectrometry proved to be unsuitable for direct analysis of the heavily contaminated soils.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(83)90093-1
|
|
|
“Morphology and the chemical make-up of the inorganic components of black corals”. Nowak D, Florek M, Nowak J, Kwiatek W, Lekki J, Chevallier P, Hacura A, Wrzalik R, Ben-Nissan B, Van Grieken R, Kuczumow A, Materials science and engineering: part C: biomimetic materials 29, 1029 (2009). http://doi.org/10.1016/J.MSEC.2008.08.028
Abstract: Black corals (Cnidaria, Antipatharia) from three different sources were investigated with the aim of detecting inorganic components and their morphology. In general, the skeleton of black corals was composed of the chitin fibrils admixed with peptides and the chitin presence was confirmed by the X-ray diffraction (XRD), Fourier Transformed Infrared Spectrometry (FTIR) and microRaman Microscopy, the latter giving the opportunity of tracing single fibrils and their location. The composition and concentrations of the inorganic components of the black corals were measured, using a scanning electron microprobe and micro-Particle Induced X-ray Emission (µ-PIXE). The application of such instruments enabled the estimation of the constituent distributions in a microscale. The mapping option was the most useful technique of making analyses in these studies, just to reveal the composition of chamber-like cells. Analysis of the morphology and microstructure showed that there were three distinct regions within the coral: a core and the cells encircled with adjacent interface gluing strips. The majority of the elements analyzed were selectively distributed and segregated in a striking way in mentioned distinctive zones of the skeleton and it was detected for the first time. The core area was characterized by the relatively elevated concentrations of Ca. The measurements gave extremely clear images of the distribution of particular elements in the skeletal tissue, with I, Ca, K and Fe much more concentrated in the gluing zones, while C, N, Na and Mg present in the interiors of particular skeletal cells. The distribution of some elements (Mg, Fe) and some compounds (chitin) and functional groups (SS, CI) allows differentiating the biological and mechanical functions of particular fragments of the rods. The kinds of elements and their concentrations measured were essentially in compliance with rare data available in the literature. The Raman technique gave the additional qualitative information about the structure of gluing zone and the chitin fibrils and surrounding matrix inside the cell interior.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MSEC.2008.08.028
|
|
|
“Organic and inorganic compounds in limestone weathering crusts from cathedrals in Southern and Western Europe”. Fobe BO, Vleugels GJ, Roekens EJ, Van Grieken RE, Hermosin B, Ortega-Calvo JJ, Sanchez del Junco A, Saiz-Jimenez C, Environmental science and technology 29, 1691 (1995). http://doi.org/10.1021/ES00006A038
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES00006A038
|
|
|
“Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples”. Daems D, van Nuijs ALN, Covaci A, Hamidi-Asl E, Van Camp G, Nagels LJ, Biomedical chromatography 29, 1124 (2015). http://doi.org/10.1002/BMC.3400
Abstract: The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3ngmL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25ngmL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright (c) 2014 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
DOI: 10.1002/BMC.3400
|
|
|
“Selenium in environmental waters : determination, speciation and concentration levels”. Robberecht H, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 29, 823 (1982). http://doi.org/10.1016/0039-9140(82)80252-X
Abstract: This article reviews the different methods used for the determination of selenium species in all types of environmental waters. Basic difficulties are discussed and the efficiency of the methods is explained in view of the sub-μg/1. concentration levels. Special attention is paid to preconcentration steps. Published data on speciation and concentration levels in various water samples are critically reviewed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80252-X
|
|
|
“A large area full-field EDXRF imaging system based on a THCOBRA gaseous detector”. Silva ALM, Carvalho ML, Janssens K, Veloso JFCA, Journal of analytical atomic spectrometry 30, 343 (2015). http://doi.org/10.1039/C4JA00301B
Abstract: By taking advantage of the attractive features in terms of gain, position and energy resolution of the 2D-THCOBRA detector, a new large area Full-Field X-ray Fluorescence Imaging (FF-XRFI) system for EDXRF imaging applications was developed. The proposed FF-XRFI system has an active area of 10 x 10 cm(2) and can be used to examine macroscopic samples with a moderately good energy resolution (< 1.6 keV FWHM at 8 keV) and a suitable spatial resolution (similar to 500 mu m FWHM). This combination of characteristics allows us to record elemental distribution maps from the surface of different sample types by combining image and energy information. Two different approaches were used for X-ray optics, one based on a single pinhole and another based on a parallel multiple-hole collimator. To illustrate the system capabilities, some sample examples were imaged and studied.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 11
DOI: 10.1039/C4JA00301B
|
|
|
“Component selection for a compact micro-XRF spectrometer”. Bichlmeier S, Janssens K, Heckel J, Gibson D, Hoffmann P, Ortner HM, X-ray spectrometry 30, 8 (2001). http://doi.org/10.1002/XRS.457
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 33
DOI: 10.1002/XRS.457
|
|
|
“Full spectral XANES imaging using the Maia detector array as a new tool for the study of the alteration process of chrome yellow pigments in paintings by Vincent van Gogh”. Monico L, Janssens K, Alfeld M, Cotte M, Vanmeert F, Ryan CG, Falkenberg G, Howard DL, Brunetti BG, Miliani C, Journal of analytical atomic spectrometry 30, 613 (2015). http://doi.org/10.1039/C4JA00419A
Abstract: A combination of synchrotron radiation (SR) micro X-ray fluorescence (m-XRF) and XRF mode X-ray absorption near edge structure (XANES) measurements at the Cr K-edge already allowed us to establish that the photo-reduction of chromates to Cr(III) compounds is the cause of darkening of chrome yellow pigments (PbCr1-xSxO4, 0 <= x <= 0.8) in a number of paintings by Vincent van Gogh and in corresponding artificially aged paint models. A silicon drift detector (SDD) was employed to record the Cr-K XRF radiation in these X-ray micro beam-based measurements. However, in view of the limited count rate capabilities and collection solid angle of a single device, m-XRF and m-XANES employing single element SDDs (or similar) are primarily suited for collection of spectral data from individual points. Additionally, collection of XRF maps via point-by-point scanning with relatively long dwell times per point is possible but is usually confined to small areas. The development of the 384 silicon-diode array Maia XRF detector has provided valuable solutions in terms of data acquisition rate, allowing for full spectral (FS) XANES imaging in XRF mode, i.e., where spectroscopic information is available at each pixel in the scanned map. In this paper, the possibilities of SR Cr K-edge FS-XANES imaging in XRF mode using the Maia detector are examined as a new data collection strategy to study the speciation and distribution of alteration products of lead chromate-based pigments in painting materials. The results collected from two micro-samples taken from two Van Gogh paintings and an aged paint model show the possibility to perform FS-XANES imaging in practical time frames (from several minutes to a few hours) by scanning regions of sample sizes of the same order (more than 500 mm). The sensitivity and capabilities of FS-XANES imaging in providing representative chemical speciation information at the microscale (spatial resolution from similar to 2 to 0.6 mm) over the entire scanned area are demonstrated by the identification of Cr(OH) 3, Cr(III) sulfates and/or Cr(III) organometallic compounds in the corresponding phase maps, as alteration products. Comparable Cr-speciation results were obtained by performing equivalent higher spatial resolution SR m-XRF/single-point m-XANES analysis using a more conventional SDD from smaller regions of interest of each sample. Thus, large-area XRF mode FS-XANES imaging (Maia detector) is here proposed as a valuable and complementary data collection strategy in relation to “ zoomed-in” high-resolution m-XRF mapping and single-point m-XANES analysis (SDD).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 28
DOI: 10.1039/C4JA00419A
|
|
|
“ID18F: a new micro-X-ray fluorescence end-station at the European Synchrotron Radiation Facility (ESRF): preliminary results”. Somogyi A, Drakopoulos M, Vincze L, Vekemans B, Camerani C, Janssens K, Snigirev A, Adams F, X-ray spectrometry 30, 242 (2001). http://doi.org/10.1002/XRS.494.ABS
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 76
DOI: 10.1002/XRS.494.ABS
|
|
|
“Iron speciation in soda-lime-silica glass: a comparison of XANES and UV-vis-NIR spectroscopy”. Ceglia A, Nuyts G, Meulebroeck W, Cagno S, Silvestri A, Zoleo A, Nys K, Janssens K, Thienpont H, Terryn H, Journal of analytical atomic spectrometry 30, 1552 (2015). http://doi.org/10.1039/C5JA00046G
Abstract: Scientific analyses of ancient glasses have been carried out for many years using elemental chemical analysis. However, it is known that the control of the redox conditions in the glass melt has a strong implication on the final hue of glass because it affects Fe2+/SFe. Therefore an increasing number of studies on the redox conditions have been published in recent years by means of synchrotron based Xray absorption spectroscopy. This is a technique which is not easily accessible and requires dedicated facilities. In this paper we describe an alternative approach by means of optical absorption spectroscopy. We synthesised 10 soda-lime-silica glasses with known redox conditions and iron concentration to calibrate the absorption at 1100 nm as a function of Fe2+ concentration. The linear extinction coefficient was also determined. These glasses were also studied by means of X-ray Absorption Near Edge Structure (XANES) spectroscopy. Electron paramagnetic resonance spectroscopy was additionally used as an ancillary method to verify the quality of our data. Furthermore 28 samples from real archaeological samples were analysed by XANES and optical spectroscopy as a case study. The Fe2+/SFe values obtained were compared and demonstrated that the two techniques were in good agreement with each other. Optical spectroscopy can be applied in situ with moderate sample preparation to determine the concentration of Fe2+. To investigate the redox conditions, especially as a first screening approach, this methodology is an important tool to take into consideration before applying more sophisticated techniques such as XANES, which is more elaborate and requires high-tech resources.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 20
DOI: 10.1039/C5JA00046G
|
|
|
“Micro-XANES study on Mn browning: use of quantitative valence state maps”. Nuyts G, Cagno S, Bugani S, Janssens K, Journal of analytical atomic spectrometry 30, 642 (2015). http://doi.org/10.1039/C4JA00386A
Abstract: Historical glass, especially non-durable medieval glass, can undergo corrosion. This sometimes results in the formation of dark-coloured manganese-rich inclusions that reduce the transparency of the glass. While unaltered bulk glass contains manganese mainly present in the +II valence state, inside the inclusions Mn is present in higher valence states (+III to +IV). Two different strategies may be considered by conservators when aiming to improve the transparency. One is based on the reduction of highly oxidised black/brown compounds using mildly reducing solutions, while the other focuses more on the extraction of manganese from the inclusions by the application of chelating agents. In this paper, a method for quantitative mapping of the Mn speciation inside partially corroded historical windowpanes based on X-Ray Absorption Near-Edge Structure (XANES) spectroscopy is discussed. The calibration of such Mn valence state maps based on the combo method, a fairly reliable way to determine the oxidation state, is described in more detail. This method is used to evaluate the effect of reducing treatments on historical glass, dated to the 14th century and originating from Sidney Sussex College (Cambridge, UK), suffering from Mn browning. Glasses were examined by means of Synchrotron Radiation (SR) based microscopic X-Ray Absorption Near-Edge Structure (mXANES) spectroscopy and microscopic X-Ray Fluorescence (mXRF). X-Ray elemental distribution maps of glass cross-sections are recorded at different energies, while Mn K-edge spectra are used to convert these into Mn valence state (VS) maps. Such valence state maps will allow evaluation of a reducing treatment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 8
DOI: 10.1039/C4JA00386A
|
|
|
“Strategies for processing mega-pixel X-ray fluorescence hyperspectral data: a case study on a version of Caravaggio's painting Supper at Emmaus”. Alfeld M, Janssens K, Journal of analytical atomic spectrometry 30, 777 (2015). http://doi.org/10.1039/C4JA00387J
Abstract: Technical progress in the fields of X-ray sources, optics and detectors is constantly enhancing the pace of data acquisition in XRF imaging. This enlarges the size of the hyperspectral datasets and the number of their sub-parts. This paper describes the challenges in processing large XRF datasets featuring several million pixels/spectra and the strategies developed to overcome them. During the investigation of historical paintings by scanning macro-XRF the main challenges are the correct identification of all spectral features in a dataset and its timely processing. For the identification of spectral features different approaches are discussed, i.e. the use of sum spectra, maximum pixel spectra and of chi(2)(r) maps. For the time-efficient, artefact-free evaluation of XRF imaging data, different software packages are evaluated and intercompared (AXIL, PyMCA, GeoPIXE and the in-house written datamuncher). The process of data evaluation is illustrated on a large dataset (3.4 MPixels) acquired during the investigation of a version of Caravaggio's Supper at Emmaus (143 x 199.5 cm(2)). This 17th century painting is currently the largest object entirely scanned with macroscopic XRF.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 67
DOI: 10.1039/C4JA00387J
|
|