|
“Determination of low-Z elements in individual environmental particles using windowless EPMA”. Ro C-U, Osán J, Van Grieken R, Analytical chemistry 71, 1521 (1999). http://doi.org/10.1021/AC981070F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC981070F
|
|
|
“Elemental composition of aircraft-sampled aerosols above the Southern Bight of the North Sea”. Rojas CM, Van Grieken R, Maenhaut W, Water, air and soil pollution 71, 391 (1993). http://doi.org/10.1007/BF00480557
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00480557
|
|
|
“Grazing exit electron probe microanalysis for surface and particle analysis”. Tsuji K, Wagatsuma K, Nullens R, Van Grieken RE, Analytical chemistry 71, 2497 (1999). http://doi.org/10.1021/AC990075P
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990075P
|
|
|
“Grazing-exit particle-induced X-ray emission analysis with extremely low background”. Tsuji K, Spolnik Z, Wagatsuma K, Van Grieken RE, Vis RD, Analytical chemistry 71, 5033 (1999). http://doi.org/10.1021/AC990568U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990568U
|
|
|
“Micro-XANES determination of ferric iron and its application in thermobarometry”. Schmid R, Wilke M, Ober R, Dong S, Janssens K, Falkenberg G, Franz L, Gaab A, Lithos 70, 381 (2003). http://doi.org/10.1016/S0024-4937(03)00107-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0024-4937(03)00107-5
|
|
|
“Cultural heritage and the environment”. Van Grieken R, Delalieux F, Gysels K, Pure and applied chemistry 70, 2327 (1998). http://doi.org/10.1351/PAC199870122327
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1351/PAC199870122327
|
|
|
“Distribution and composition of suspended matter around Sumbawa Island, Indonesia”. Eisma D, van Put A, Van Grieken R, Mitteilungen aus dem Geologisch-Paläontologischen Institut der Universität Hamburg 70, 137 (1992)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Preliminary experiment of total reflection x-ray fluorescence using two glancing x-ray beams excitation”. Tsuji K, Sato T, Wagatsuma K, Claes M, Van Grieken R, The review of scientific instruments 70, 1621 (1999). http://doi.org/10.1063/1.1149687
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1063/1.1149687
|
|
|
“X-ray spectrometry”. Török S, Labar J, Schmeling M, Van Grieken R, Analytical chemistry 70, 495r (1998)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Modeling of glow discharges: what can we learn from it?”.Bogaerts A, Gijbels R, Analytical chemistry A-pages 69, 719 (1997)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Interpretation of cappilary generated spatial and angular distribution of X-rays: theoretical modeling and experimental verification using the European Synchrotron Radiation Facility Optical Beamline”. Vincze L, Janssens K, Adams F, Engström P, Rindby A, The review of scientific instruments 69, 3494 (1998). http://doi.org/10.1063/1.1149127
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.515
DOI: 10.1063/1.1149127
|
|
|
“Direct current glow discharge mass spectrometry for elemental characterization of polymers”. Schelles W, Van Grieken R, Analytical chemistry 69, 2931 (1997). http://doi.org/10.1021/AC970186T
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC970186T
|
|
|
“Direct current glow discharge mass spectrometric analysis of Macor ceramic using a secondary cathode”. Schelles W, Van Grieken R, Analytical chemistry 68, 3570 (1996). http://doi.org/10.1021/AC960441U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC960441U
|
|
|
“X-ray spectrometry”. Török SB, Labar J, Injuk J, Van Grieken RE, Analytical chemistry R68, 467 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Echt of namaak? Venetiaans glas uit het oude Antwerpen”. de Raedt I, Janssens K, Veeckman J, De wetenschappelijke bibliotheek 67, 58 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks”. Margui E, Hidalgo M, Queralt I, van Meel K, Fontas C, Spectrochimica acta: part B : atomic spectroscopy 67, 17 (2012). http://doi.org/10.1016/J.SAB.2011.12.004
Abstract: We aimed to achieve improved instrumental sensitivity and detection limits for the analysis of several elements (Cu, Ni, Zn, Pb and Cd) in aqueous samples with energy dispersive X-ray fluorescence spectrometry (EDXRF). The metals were pre-concentrated from aqueous solutions using commercially available organic-based solid-phase extraction (SPE) disks functionalized with iminodiacetate groups. These thin-layer organic materials provide an ideal support for XRF analysis. The elements were collected on the SPE extraction disks using a simple filtration procedure (starting with 1 L of aqueous sample) that allows direct XRF measurements to be performed in the field (in situ). We evaluated the analytical possibilities and drawbacks of using this pre-concentration procedure in combination with the following XRF configurations: a handheld unit, a benchtop EDXRF system and a high-energy polarized-beam EDXRF instrument (HE-P-EDXRF). Using the HE-P-EDXRF system, the detection limits for all metals were more than one order of magnitude lower than those attained using handheld and benchtop EDXRF instrumentation. For the detection of metal concentrations higher than similar to 20 mu g/L, however, handheld or benchtop systems remain a very good option due to their extreme simplicity of operation and low-cost, compact design. We demonstrate the application of these methodologies, using the three equipment systems, to the analysis of trace concentrations of metals in different types of aqueous samples, including tap water and waste water. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2011.12.004
|
|
|
“Parameter evaluation for the analysis of oxide-based samples with radio ferquency glow discharge mass spectrometry”. de Gendt S, Van Grieken RE, Ohorodnik SK, Harrison WW, Analytical chemistry 67, 1026 (1995). http://doi.org/10.1021/AC00102A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00102A002
|
|
|
“Single particle characterisation of inorganic and organic North Sea suspension”. Jambers W, Dekov V, Van Grieken R, Marine chemistry 67, 17 (1999). http://doi.org/10.1016/S0304-4203(99)00046-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0304-4203(99)00046-8
|
|
|
“Combining multi-receiver electromagnetic induction and stepped frequency ground penetrating radar for industrial site investigation”. Van De Vijver E, Van Meirvenne M, Saey T, Delefortrie S, De Smedt P, De Pue J, Seuntjens P, European journal of soil science 66, 688 (2015). http://doi.org/10.1111/EJSS.12229
Abstract: The soil at industrial sites is frequently characterized by very heterogeneous properties, which are often related to physical disturbance and contamination. A conventional approach to characterize the soil, with only a limited number of invasive observations, fails to capture the full extent of soil heterogeneity. Proximal soil sensing provides efficient tools to record spatially dense soil information. Nevertheless, because the output of most sensors is affected by more than one soil property, the simultaneous characterization of different soil properties requires the use of multiple sensors. Here, we apply multi-receiver electromagnetic induction (EMI) and stepped frequency ground penetrating radar (GPR) to survey a former gasworks site in a seaport area of Belgium. We used the EMI and GPR sensors in a motorized system to obtain densely sampled measurements of apparent electrical conductivity, apparent magnetic susceptibility and contrasts in relative dielectric permittivity. Our study shows that the sensors give detailed information on the variation in these electromagnetic soil properties. Interpretation of the variation in terms of the stratification of the soil was hampered by localized anthropogenic disturbances. However, the sensors provided complementary information that enabled the identification, discrimination and accurate location of several of these localized disturbances, including underground utility services such as electric cables, buried structures such as the remains of foundations and contamination by salts. Because these represent typical targets in industrial site investigation, we conclude that multi-receiver EMI and stepped frequency GPR provide a useful set of tools to expedite the investigation of industrial sites.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1111/EJSS.12229
|
|
|
“Infiltration or indoor sources as determinants of the elemental composition of particulate matter inside a school in Wroclaw, Poland?”.Zwozdziak A, Sowka I, Krupińska B, Zwozdziak J, Nych A, Building and environment 66, 173 (2013). http://doi.org/10.1016/J.BUILDENV.2013.04.023
Abstract: Children's exposure to air pollution requires a focus on air quality in places where they spend most time, e.g. in schools. Therefore, understanding how indoor elemental concentrations relate the outdoor ones is necessary to create healthy indoor school environment. The aims of this study were to examine the elemental composition of particulate matter (PM1, PM2.5, PM10) in the school and also to investigate to what degree indoor elemental concentrations are affected by outdoor air or generated inside the school. The measurements were performed inside and outside the public school building in the centre of the city. It was observed that concentrations of most elements were higher at school than outside. The dominant elements in PM1 both indoors and outdoors were S, Cl, K, and Zn. PM2.5 and PM10 fractions inside the school were clearly enriched in elements of mineral origin, additionally S, Zn, K and Cl were also present in high concentrations both indoors and outdoors. Results suggested that a significant contribution to indoor Zn, Pb and S concentrations in the PM2.5 fraction was from penetration of outdoor air. 88%, 80% and 90% of the observed total variations in indoor concentrations of Zn, Pb, and S were explained by the linear relationship between indoor and outdoor concentrations. The lack of correlation between indoor and outdoor concentrations obtained for Si, Ca, Ti, Sr indicated that these metals were more likely to originate from indoor sources. (C) 2013 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.BUILDENV.2013.04.023
|
|
|
“Nomenclature for radioanalytical chemistry (IUPAC Recommendations 1994)”. Van Grieken R, de Bruin M, Pure and applied chemistry 66, 2513 (1994). http://doi.org/10.1351/PAC199466122513
Abstract: Nearly 200 terms commonly used in radioanalytical chemistry are unambiguously defined. The list is partially based on an earlier IUPAC-glossary (Pure Appl. Chem. 54 (1982) 1533-1554), but some modifications have been made, terms related to nuclear physics and technology have not been reconsidered and numerous new entries from the realm of radiometric analysis, radioimmunoassay and related techniques have been included.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1351/PAC199466122513
|
|
|
“Stoichiometry design in hierarchical CoNiFe phosphide for highly efficient water oxidation”. Chen J, Ying J, Xiao Y, Dong Y, Ozoemena K I, Lenaerts S, Yang X, Science China : materials 65, 2685 (2022). http://doi.org/10.1007/S40843-022-2061-X
Abstract: Rational composition design of trimetallic phosphide catalysts is of significant importance for enhanced surface reaction and efficient catalytic performance. Herein, hierarchical CoxNiyFezP with precise control of stoichiometric metallic elements (x:y:z = (1-10):(1-10):1) has been synthesized, and Co1.3Ni0.5Fe0.2P, as the most optimal composition, exhibits remarkable catalytic activity (eta = 320 mV at 10 mA cm(-2)) and long-term stability (ignorable decrease after 10 h continuous test at the current density of 10 mA cm(-2)) toward oxygen evolution reaction (OER). It is found that the surface P in Co1.3Ni0.5Fe0.2P was replaced by 0 under the OER process. The density function theory calculations before and after long-term stability tests suggest the clear increasing of the density of states near the Fermi level of Co1.3Ni0.5Fe0.2P/ Co1.3Ni0.5Fe0.2O, which could enhance the OH- adsorption of our electrocatalysts and the corresponding OER performance.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
Impact Factor: 8.1
DOI: 10.1007/S40843-022-2061-X
|
|
|
“An experimental and numerical study of the suppression of jets, counterflow, and backflow in vortex units”. Kulkarni S, Gonzalez-Quiroga A, Nuñez M, Schuerewegen C, Perreault P, Goel C, Heynderickx GJ, Van Geem KM, Marin GB, AIChE journal 65, e16614 (2019). http://doi.org/10.1002/AIC.16614
Abstract: Vortex units are commonly considered for various single and multiphase applications due to their process intensification capabilities. The transition from gas‐only flow to gas–solid flow remains largely unexplored nonetheless. During this transition, primary flow phenomenon, jets, and secondary flow phenomena, counterflow and backflow, are substantially reduced, before a rotating solids bed is established. This transitional flow regime is referred to as the vortex suppression regime. In the present work, this flow transition is identified and validated through experimental and computational studies in two vortex units with a scale differing by a factor of 2, using spherical aluminum and alumina particles. This experimental data supports the proposed theoretical particle monolayer solids loading that allows estimation of vortex suppression regime solids capacity for any vortex unit. It is shown that the vortex suppression regime is established at a solids loading theoretically corresponding to a monolayer being formed in the unit for 1g‐Geldart D‐ and 1g‐Geldart B‐type particles. The model closely agrees with experimental vortex suppression range for both aluminum and alumina particles. The model, as well as the experimental data, shows that the flow suppression regime depends on unit dimensions, particle diameter, and particle density but is independent of gas flow rate. This combined study, based on experimental and computational data and on a theoretical model, reveals the vortex suppression to be one of the basic operational parameters to study flow in a vortex unit and that a simple monolayer model allows to estimate the needed solids loading for any vortex device to induce this flow transition.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1002/AIC.16614
|
|
|
“Modeling of electroporation induced by pulsed electric fields in irregularly shaped cells”. Mescia L, Chiapperino MA, Bia P, Gielis J, Caratelli D, IEEE transactions on biomedical engineering 65, 414 (2018). http://doi.org/10.1109/TBME.2017.2771943
Abstract: During the past decades, the poration of cell membrane induced by pulsed electric fields has been widely investigated. Since the basic mechanisms of this process have not yet been fully clarified, many research activities are focused on the development of suitable theoretical and numerical models. To this end, a nonlinear, nonlocal, dispersive, and space-time numerical algorithm has been developed and adopted to evaluate the transmembrane voltage and pore density along the perimeter of realistic irregularly shaped cells. The presented model is based on the Maxwell's equations and the asymptotic Smoluchowski's equation describing the pore dynamics. The dielectric dispersion of the media forming the cell has been modeled by using a general multirelaxation Debye-based formulation. The irregular shape of the cell is described by using the Gielis' superformula. Different test cases pertaining to red blood cells, muscular cells, cell in mitosis phase, and cancer-like cell have been investigated. For each type of cell, the influence of the relevant shape, the dielectric properties, and the external electric pulse characteristics on the electroporation process has been analyzed. The numerical results demonstrate that the proposed model is an efficient numerical tool to study the electroporation problem in arbitrary-shaped cells.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1109/TBME.2017.2771943
|
|
|
“Viscosity measurement and correlation of unloaded and CO₂-loaded aqueous solutions of N-methyldiethanolamine + 2-amino-2-methyl-1-propanol”. Kummamuru NB, Eimer DA, Idris Z, Journal Of Chemical And Engineering Data 65, 3072 (2020). http://doi.org/10.1021/ACS.JCED.0C00088
Abstract: This work contributes to new and complementary experimental viscosity data for blended amine mixtures of aqueous N-methyldiethanolamine + 2-amino-2-methyl-1-propanol (MDEA + AMP) solutions with and without CO2 at different temperatures and mass fractions. For the unloaded MDEA + AMP solutions, measurements were conducted with total amine mass fractions ranging from 0.30 to 0.60. In the case of CO2-loaded aqueous MDEA + AMP solutions, experiments were performed at CO2 loadings ranging from 0.11 to 0.80. Proposed correlations were used to represent viscosity at the unloaded and CO2-loaded solutions within experimental uncertainty.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
Impact Factor: 2.6
DOI: 10.1021/ACS.JCED.0C00088
|
|
|
“Oxidation states of uranium in DU particles from Kosovo”. Salbu B, Janssens K, Lind OC, Proost K, Danesi PR, Journal of environmental radioactivity 64, 167 (2003). http://doi.org/10.1016/S0265-931X(02)00047-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.31
DOI: 10.1016/S0265-931X(02)00047-4
|
|
|
“Crystal structure controls on oriented primary magnetite micro-inclusions in plagioclase From oceanic gabbro”. Bian G, Ageeva O, Roddatis V, Li C, Pennycook TJ, Habler G, Abart R, Journal of petrology 64, egad008 (2023). http://doi.org/10.1093/PETROLOGY/EGAD008
Abstract: Oriented needle-, lath- and plate-shaped magnetite micro-inclusions in rock forming plagioclase from mafic intrusive rocks, were investigated using correlated optical microscopy and scanning transmission electron microscopy. The magnetite micro-inclusions were analysed on cuts parallel and perpendicular to the inclusion-elongation directions. The crystal structures of the two phases are in direct contact along the interfaces. The shape, shape orientation and crystallographic orientation relationships between the magnetite micro-inclusions and the plagioclase host appear to be controlled by the tendency of the system to optimise lattice match along the interfaces. The elongation direction of the inclusions ensures good match between prominent oxygen layers in the magnetite and plagioclase crystal structures across the interfaces bounding the inclusions parallel to their elongation direction. In cross-section, additional modes of lattice match, such as the commensurate impingement of magnetite and plagioclase lattice planes along the interfaces, the parallel alignment of the interfaces to low-index lattice planes of magnetite or plagioclase, or the parallel alignment to low index lattice planes of both phases are observed, which appear to control the selection of interface facets, as well as the shape and crystallographic orientation relationships between magnetite micro-inclusions and plagioclase host. The systematics of the inclusion cross-sectional shapes and crystallographic orientation relationships indicate recrystallisation of magnetite with potential implications for natural remanent magnetisation of magnetite-bearing plagioclase grains.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 3.9
DOI: 10.1093/PETROLOGY/EGAD008
|
|
|
“Determination of fluorine in uranium oxyfluoride particles as an indicator of particle age”. Kips R, Pidduck AJ, Houlton MR, Leenaers A, Mace JD, Marie O, Pointurier F, Stefaniak EA, Taylor PDP, van den Berghe S, van Espen P, Van Grieken R, Wellum R, Spectrochimica acta: part B : atomic spectroscopy 64, 199 (2009). http://doi.org/10.1016/J.SAB.2008.12.001
Abstract: As swipe samples from enrichment activities typically contain uranium particles with a detectable amount of fluorine, the question was raised whether the analysis of fluorine in particles could complement the information on the uranium isotope ratios. For this, uranium oxyfluoride particles were prepared from the controlled hydrolysis of uranium hexafluoride (UF6). The relative amount of fluorine was characterized by scanning electron microscopy combined with energy-dispersive X-ray spectrometry (SEM-EDX), as well as ion-microprobe secondary ion mass spectrometry (IM-SIMS). Of particular interest was the assessment of the reduction of the amount of fluorine over time, and after exposure to UV-light and high temperatures. Micro-Raman spectrometry (MRS) was applied to look for differences in molecular structure between these various sample types. Both SEM-EDX and IM-SIMS showed a general reduction of the fluorine-to-uranium ratio after 12 years of storage. The exposure to UV-light and high temperatures was found to have accelerated the loss of fluorine. A distinct peak at 865 cm− 1 Raman shift was detected for the majority of particles analyzed by MRS. For the particles that were heat-treated, the Raman spectra were similar to the spectrum of U3O8. Although often large variations were observed between particles from the same sample, the three particle measurement techniques (IM-SIMS, SEM-EDX and MRS) showed some consistent trends. They therefore appear promising in terms of the ability to place bounds on particle age, as well as shedding light on the complex processes involved in UO2F2 particle ageing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/J.SAB.2008.12.001
|
|
|
“Localization of aluminum in tissues”. Verbueken AH, van de Vijver FL, Nouwen EJ, Van Grieken RE, de Broe ME, Contributions to nephrology 64, 124 (1988)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“X-ray spectrometry”. Török SB, Van Grieken RE, Analytical chemistry 64r, 180 (1992)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|