Records |
Author |
Bogaerts, A.; Gijbels, R. |
Title |
Computer simulation of an analytical direct current glow discharge in argon: influence of the cell dimensions on the plasma quantities |
Type |
A1 Journal article |
Year |
1997 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
12 |
Issue |
|
Pages |
751-759 |
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
London |
Editor |
|
Language |
|
Wos |
A1997XM00600009 |
Publication Date |
0000-00-00 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.379 |
Times cited |
21 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 3.379; 1997 IF: 3.595 |
Call Number |
UA @ lucian @ c:irua:19605 |
Serial |
464 |
Permanent link to this record |
|
|
|
Author |
Adams, F.; Adriaens, A.; Aerts, A.; de Raedt, I.; Janssens, K.; Schalm, O. |
Title |
Micro and surface analysis in archaeology |
Type |
A1 Journal article |
Year |
1997 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
12 |
Issue |
3 |
Pages |
257-265 |
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
A1997WN16300001 |
Publication Date |
2002-07-26 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.379 |
Times cited |
|
Open Access |
|
Notes |
|
Approved |
Most recent IF: 3.379; 1997 IF: 3.595 |
Call Number |
UA @ admin @ c:irua:16274 |
Serial |
5711 |
Permanent link to this record |
|
|
|
Author |
Bogaerts, A.; Gijbels, R. |
Title |
Relative sensitivity factors in glow discharge mass spectrometry: the role of charge transfer ionization |
Type |
A1 Journal article |
Year |
1996 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
11 |
Issue |
|
Pages |
841-847 |
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
London |
Editor |
|
Language |
|
Wos |
A1996VG92800032 |
Publication Date |
2004-04-20 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477;1364-5544; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.466 |
Times cited |
38 |
Open Access |
|
Notes |
|
Approved |
|
Call Number |
UA @ lucian @ c:irua:16243 |
Serial |
2860 |
Permanent link to this record |
|
|
|
Author |
Held, A.; Taylor, P.; Ingelbrecht, C.; de Bièvre, P.; Broekaert, J.; van Straaten, M.; Gijbels, R. |
Title |
Determination of scandium in high-purity titanium using inductively coupled plasma mass spectrometry and glow discharge mass spectrometry as part of its certification as a reference material |
Type |
A1 Journal article |
Year |
1995 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
10 |
Issue |
|
Pages |
849-852 |
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
London |
Editor |
|
Language |
|
Wos |
A1995TB75500024 |
Publication Date |
2004-04-20 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477;1364-5544; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.466 |
Times cited |
6 |
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ lucian @ c:irua:12265 |
Serial |
671 |
Permanent link to this record |
|
|
|
Author |
van Straaten, M.; Swenters, K.; Gijbels, R.; Verlinden, J.; Adriaenssens, E. |
Title |
Analysis of platinum powder by glow discharge mass spectrometry |
Type |
A1 Journal article |
Year |
1994 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
9 |
Issue |
|
Pages |
1389-1397 |
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
London |
Editor |
|
Language |
|
Wos |
A1994PY14900012 |
Publication Date |
2004-04-20 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477;1364-5544; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.466 |
Times cited |
17 |
Open Access |
|
Notes |
|
Approved |
no |
Call Number |
UA @ lucian @ c:irua:10253 |
Serial |
103 |
Permanent link to this record |
|
|
|
Author |
Aghaei, M.; Bogaerts, A. |
Title |
Particle transport through an inductively coupled plasma torch: elemental droplet evaporation |
Type |
A1 Journal article |
Year |
2016 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
31 |
Issue |
31 |
Pages |
631-641 |
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
Abstract |
We studied the transport of copper droplets through an inductively coupled plasma, connected to the sampling cone of a mass spectrometer, by means of a computational model. The sample droplets are followed until they become evaporated. They are inserted as liquid particles from the central inlet and the effects of injection position (i.e. “on” and “off” axis), droplet diameter, as well as mass loading flow rate are investigated. It is shown that more “on-axis” injection of the droplets leads to a more straight path line, so that the droplets move less in the radial direction and are evaporated more on the central axis, enabling a better sample transfer efficiency to the sampler cone. Furthermore, there are optimum ranges of diameters and flow rates, which guarantee the proper position of evaporation along the torch, i.e. not too early, so that the sample can get lost in the torch, and not too late, which reduces the chance of becoming ionized before reaching the sampler. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Wos |
000372857300003 |
Publication Date |
2015-07-07 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.379 |
Times cited |
21 |
Open Access |
|
Notes |
The authors are very grateful to H. Lindner for the many fundamental and fruitful discussions. They are also gratefully acknowledge nancial support from the Fonds voor Wetenschappelijk Onderzoek (FWO). |
Approved |
Most recent IF: 3.379 |
Call Number |
c:irua:133240 |
Serial |
4024 |
Permanent link to this record |
|
|
|
Author |
Bleiner, D.; Altorfer, H. |
Title |
A novel gas inlet system for improved aerosol entrainment in laser ablation inductively coupled plasma mass spectrometry |
Type |
A1 Journal article |
Year |
2005 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
|
Issue |
|
Pages |
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
Abstract |
In order to minimize the dead volume in large cells for laser ablation inductively coupled plasma mass spectrometry, and improve the aerosol entrainment characteristics, the gas inlet nozzle has been set in rotation. This allowed a wider volume to be swept than with the traditional static inlet nozzle approach. Therefore, sensitivity combined with site-to-site repeatability was improved by a factor of two, together with minimization of aerosol loss within the cell and signal dispersion. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
London |
Editor |
|
Language |
|
Wos |
000231246900013 |
Publication Date |
2005-07-01 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.379 |
Times cited |
21 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 3.379; 2005 IF: 3.640 |
Call Number |
UA @ lucian @ c:irua:99309 |
Serial |
4524 |
Permanent link to this record |
|
|
|
Author |
Bleiner, D.; Belloni, F.; Doria, D.; Lorusso, A.; Nassisi, V. |
Title |
Overcoming pulse mixing and signal tailing in laser ablation inductively coupled plasma mass spectrometry depth profiling |
Type |
A1 Journal article |
Year |
2005 |
Publication |
Journal of analytical atomic spectrometry |
Abbreviated Journal |
J Anal Atom Spectrom |
Volume ![sorted by Volume (numeric) field, descending order (down)](img/sort_desc.gif) |
|
Issue |
|
Pages |
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
Abstract |
The laser ablation-induced plasma was used as a composition-con trolled source for ion implantation in Si crystals. Then, laser ablation in combination with inductively coupled plasma mass spectrometry was used for the elemental depth profiling of the implanted samples. Monte Carlo simulations permitted us to conclude that a depth resolution of tens of nm would be necessary to define the shape of the implantation profiles, as is obtained using XPS and RBS, whereas a hundred nm depth resolution is sufficient to determine the total implanted dose. The detection power of LA-ICP-MS would routinely allow rapid analytical control on the trace level implanted dose. Nevertheless, this technique is limited in terms of depth profiling resolution due to pulse mixing and signal tailing induced during the aerosol transport. Raw signal processing procedures were developed for the minimization of shapeline dispersion, deconvolution of pulse mixing and more appropriate assessment of the implanted profiles. Shapeline dispersion could be corrected for by determining the signal waning constant and implementing this information for a non-affine alibi transformation of the LA-ICP-MS signal traces. Pulse mixing deconvolution was attained with an algorithm that considered accumulated signal intensity due to pulse-on-pulse stacking, i.e., the latest pulse on top of all antecedent individual pulses' exponential tails proportionally. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
London |
Editor |
|
Language |
|
Wos |
000233958900018 |
Publication Date |
2005-10-10 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0267-9477 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
3.379 |
Times cited |
26 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 3.379; 2005 IF: 3.640 |
Call Number |
UA @ lucian @ c:irua:99278 |
Serial |
4525 |
Permanent link to this record |