“Conservation of stained glass windows with protective glazing : main results from the European VIDRIO research programme”. Bernardi A, Becherini F, Verità, M, Godoi RHM, Kontozova-Deutsch V, Van Grieken R, et al, Journal of cultural heritage 14, 527 (2013). http://doi.org/10.1016/J.CULHER.2012.11.009
Abstract: The methodology of protecting the European stained glass windows against environmental risk (e.g. meteorological factors, air pollution, microorganisms) by means of an external glazing is not new. In spite of many scientific studies carried out in the last 20 years, some questions were still up for discussion. The European VIDRIO (20022005) project gave an answer to these questions. The research carried out by the different project partners established a new multidisciplinary approach aimed at evaluating the efficiency of the protective glazing systems and their effects on stained glass windows conservation, and finally at assessing the most appropriate strategy to preserve stained glass windows. Scientific results showed that the so-called isothermal glazing (i.e. ventilation by the air coming from the inside of the building) protected efficiently the ancient stained glass window from environmental attack (i.e. rain, pollutants, condensation, thermal shocks) with very limited secondary effects. The scientific research highlighted that its efficiency was strongly related to the technical design of the protective system. In particular, the ventilation and the size of the interspace had to be carefully considered. The research developed within the VIDRIO project was turned into general recommendations to the owners and practitioners on the best practice for the stained glass windows future conservation.
Keywords: A1 Journal article; Art; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CULHER.2012.11.009
|
“Elemental x-ray images obtained by grazing-exit electron probe microanalysis (GE-EPMA)”. Tsuji K, Nullens R, Wagatsuma K, Van Grieken RE, Journal of analytical atomic spectrometry 14, 1711 (1999). http://doi.org/10.1039/A905301H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A905301H
|
“Influence of sample thickness, excitation energy and geometry on particle size effects in XRF”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 14, 183 (1985). http://doi.org/10.1002/XRS.1300140409
Abstract: Expressions are presented for calculating the matrix effect and the pure particle size effect in the XRF analysis of particulate samples with a discrete particle size. The equations are based on the absorption-weighted radiometric diameter concept. Two excitationdetection geometries are considered, with the angles between the sample plane and both the incident and emerging radiation being either 90° (π geometry) or 45° (π/2 geometry). Calculations were made for different sample loadings and exciting radiation energies. The influence of these parameters on the matrix and pure particle size effects is shown. From the results, it is possible to predict the performances of alternative experimental correction procedures for the particle size effect, involving dual measurements at different excitation energies or in different excitationdetection geometries.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300140409
|
“Investigation of volatile organic compounds in museum storage areas”. Alvarez-Martin A, Wilcop M, Anderson R, Wendt D, Barden R, Kavich GM, Air Quality Atmosphere And Health 14, 1797 (2021). http://doi.org/10.1007/S11869-021-01054-2
Abstract: This study investigates the complex mixture of volatile organic compounds (VOCs) released by and accumulated within a collection of historic medicinal, pharmaceutical, and cosmetic artifacts housed at the National Museum of American History (Smithsonian Institution). In recent years, staff have become concerned, both for the safety of the objects and for personnel working in the collection, about strong unremediated odors accumulating within several storage cabinets. Museum staff also wondered if non-odorous off-gassing might need remediation. Solid-phase microextraction combined with gas chromatography–mass spectrometry analysis (SPME–GC–MS) was used to identify VOCs present in the storage room housing the collection. Over 160 compounds were detected and identified overall. Among these, 49 appeared to be directly related to ingredients used in the manufacture of many collection items. The results of the study suggest that SPME–GC–MS can be a strong tool for the rapid screening of multicomponent museum collections exhibiting off-gassing problems, before the pursuit of other more tedious analytical approaches. Additionally, the study reveals valuable insight into the characteristic volatile emission of historic medicinal, pharmaceutical, and cosmetic artifacts, increasing understanding of, and decision-making for, similar collections of objects. Eventually, it is hoped that this information can be used to inform mitigation strategies for the capture and reduction of VOCs in collections storage areas.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 3.184
DOI: 10.1007/S11869-021-01054-2
|
“An improved electrochemical aptasensor for chloramphenicol detection based on aptamer incorporated gelatine”. Hamidi-Asl E, Dardenne F, Blust R, De Wael K, Sensors 15, 7605 (2015). http://doi.org/10.3390/S150407605
Abstract: Because of the biocompatible properties of gelatine and the good affinity of aptamers for their targets, the combination of aptamer and gelatine type B is reported as promising for the development of biosensing devices. Here, an aptamer for chloramphenicol (CAP) is mixed with different types of gelatine and dropped on the surface of disposable gold screen printed electrodes. The signal of the CAP reduction is investigated using differential pulse voltammetry. The diagnostic performance of the sensor is described and a detection limit of 1.83 x 10(-10) M is found. The selectivity and the stability of the aptasensor are studied and compared to those of other CAP sensors described in literature.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.677
Times cited: 21
DOI: 10.3390/S150407605
|
“Composition of 15-17th century archaeological glass vessels excavated in Antwerp, Belgium”. Janssens KH, Deraedt I, Schalm O, Veeckman J, Mikrochimica acta: supplementum 15, 253 (1998)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Polycyclodextrin and carbon nanotubes as composite for tyrosinase immobilization and its superior electrocatalytic activity towards butylparaben an endocrine disruptor”. Rather JA, Pilehvar S, De Wael K, Journal of nanoscience and nanotechnology 15, 3365 (2015). http://doi.org/10.1166/JNN.2015.10210
Abstract: We developed a protocol for the immobilization of tyrosinase (Tyr) on the composite of polycyclodextrin polymer (CDP) and carbon nanotubes for the detection of an endocrine disruptor, i.e., butylparaben (BP). The formation of the CDP polymer was characterized by UV-Vis spectrophotometry. The conducting film of cross-linked CDP and carbon nanotubes, displays excellent matrix capabilities for Tyr immobilization. The host-guest chemical reaction ability of CD and the ππ stacking interaction assure the bioactivity of Tyr towards butylparaben. The developed biosensor was characterized electrochemically by electrochemical impedance spectroscopy. The enzyme-substrate kinetic parameters such as the apparent Michaelis-Menten constant (K M app) was measured under saturated substrate concentration. The determination of butylparaben was carried out by using square wave voltammetry over the concentration range of 2.1 to 35.4 μM with a detection limit of 0.1 μM. The fabricated biosensor was successfully applied in real-life cosmetic samples with good recovery ranging from 98.5 to 102.8%.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 3
DOI: 10.1166/JNN.2015.10210
|
“Critical assessment and proposal for reconstruction of a grazing emission X-ray fluorescence instrument”. Kuczumow A, Schmeling M, Van Grieken R, Journal of analytical atomic spectrometry 15, 535 (2000). http://doi.org/10.1039/A908661G
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A908661G
|
“Determination of barium, lanthanum, cerium and neodymium in lateritic materials by various energy-dispersive X-ray fluorescence techniques and neutron activation analysis”. Labrecque JJ, Beusen JM, Van Grieken RE, X-ray spectrometry 15, 13 (1986). http://doi.org/10.1002/XRS.1300150105
Abstract: A comparison of four methods for the determination of barium, lanthanum, cerium and neodymium in lateritic materials from Brazil is presented. Three of the methods were based on x-ray fluorescence (XRF) spectroscopy: two by radioisotope excitation (Co-57 and Am-241) and one by secondary target XRF (a molybdenum target with a tungsten anode). The other method was based on neutron activation analysis employing both a Ge(Li) coaxial detector and a high-purity germanium detector. The results from these four methods were similar for lanthanum, cerium and neodymium, but for barium at low concentrations (<500 ppm) the neutron activation and the secondary target XRF methods were not suitable. Data on the precision and accuracy of these methods using a series of standard reference rocks are given. The advantages and limitations of each of these methods with respect to the analysis of lateritic materials are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150105
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
“Heavy metal distribution in sediments of Krishna River basin, India”. Ramesh R, Subramanian V, Van Grieken R, Environmental geology and water sciences 15, 207 (1990)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Heterogeneity effects in direct XRF analysis of traces of heavy metals preconcentrated on polyurethane foam sorbents”. Török S, Braun T, Van Dyck P, Van Grieken R, X-ray spectrometry 15, 7 (1986). http://doi.org/10.1002/XRS.1300150104
Abstract: Trace amounts of heavy metals were preconcentrated on discs of polyurethane (PU) foam loaded with ammonium diethyldithiocarbamate (DDTC), to increase the sensitivity of XRF. Since the diameter of the cavities in the open-cell PU foams reaches 30300 μm, considerable heterogeneity effects might occur, which could reduce the accuracy of the method. The possible systematic error introduced by considering the sample to be homogeneous is calculated using the Berry et al. model. The calculations show that the underestimation of the absorption correction factor when considering the sample as being homogeneous is less than 2% for high-Z elements when the sample thickness is at least 2 mm. The detection limits are also around the minima for this thickness.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150104
|
“Kinetics of iron(II) oxidation in seawater of various pH : reply”. Roekens EJ, Van Grieken RE, Marine chemistry 15, 281 (1984). http://doi.org/10.1016/0304-4203(84)90025-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(84)90025-2
|
“Monte Carlo simulation of backscattered peaks in secondary target energy-dispersive X-ray spectra”. Van Dyck P, Török S, Van Grieken R, X-ray spectrometry 15, 231 (1986). http://doi.org/10.1002/XRS.1300150403
Abstract: A Monte Carlo simulation has been developed to describe the incoherent and coherent scatter processes for the complex geometry of a secondary target energy-dispersive x-ray fluorescence system. Photons are followed from the x-ray tube anode until the detection of scattered secondary target photons in the active Si layer of the detector. The program quantitatively shows the broadening of the incoherent scatter peak with increasing atomic number, and it models the incoherent peak shape adequately. The incoherent-to-coherent scatter intensity ratios obtained differ by 1030% from the theoretical values, while their dependence on the sample atomic number corresponds to that expected from theory.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150403
|
“Present and future applications of beam techniques in environmental microanalysis”. Jambers W, Van Grieken R, Trends in analytical chemistry 15, 114 (1996). http://doi.org/10.1016/0165-9936(95)00098-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0165-9936(95)00098-4
|
“Quantification problems in light element determination by grazing emission X-ray fluorescence”. Kuczumow A, Claes M, Schmeling M, Van Grieken R, de Gendt S, Journal of analytical atomic spectrometry 15, 415 (2000). http://doi.org/10.1039/A908724I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A908724I
|
“Quantitative characterisation of the leaching of lead and other elements from glazed surfaces of historical ceramics”. Szalóki I, Braun M, Van Grieken R, Journal of analytical atomic spectrometry 15, 843 (2000). http://doi.org/10.1039/B000746N
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B000746N
|
“Sample preparation for X-ray fluorescence analysis”. Injuk J, Van Grieken R page 13338 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“A simple absorption correction for electron probe X-ray microanalysis of bulk samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 115 (1986). http://doi.org/10.1002/XRS.1300150209
Abstract: A simple procedure is proposed for the calculation of the absorption correction factor in electron-probe x-ray microanalysis. It is based on the concept of an effective depth of x-ray production, assuming a rectangular depth distribution function for x-ray generation. This effective x-ray production depth is expressed as a fraction of the x-ray excitation depth given by Whelan's expression. Adequate values for this fraction are presented. Two versions are considered. In the first the effective x-ray production is a function of both the characteristic x-ray energy and the atomic numbers of the matrix elements, whereas in the second one, which is indicated for routine use, the energy dependence is neglected. Calculations pointed to satisfactory results, even for low x-ray energies and high overvoltages.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150209
|
“Spectrometric determination of silicon in food and biological samples: an interlaboratory trial”. van Dyck K, Robberecht H, van Cauwenbergh R, Deelstra H, Arnaud J, Willemyns L, Benijts F, Centeno JA, Taylor H, Soares ME, Bastos ML, Ferreira MA, d'Haese PC, Lamberts LV, Hoenig M, Knapp G, Lugowski SJ, Moens L, Riondato J, Van Grieken R, Claes M, Verheyen R, Clement L, Uytterhoeven M, Journal of analytical atomic spectrometry 15, 735 (2000). http://doi.org/10.1039/B000572J
Abstract: Accuracy and precision of silicon determination in biological matrices (serum, urine, water, beer and spinach) by spectrometric techniques (when necessary after acid destruction) were assessed by means of a collaborative interlaboratory trial. The trial was set up in accordance with ISO 5725-2 (1994). The relative overall repeatability standard deviation was acceptable. It varied between 4% for spinach powder (mean content: 176 mg kg(-1)) and 11% for serum (mean content: 5.33 mg L-1). On the other hand, the relative overall between-laboratory standard deviation was found to vary from a satisfactorily 15% for spinach after destruction (mean content: 3.32 mg L-1) to an unacceptable 107% for spinach powder (mean content: 176 mg kg(-1)). The overall conclusion of the trial was that silicon determination in biological matrices can properly be performed by spectrometric techniques. However, when sample pretreatment (i.e., acid destruction) is needed prior to silicon determination problems still remain.
Keywords: A1 Journal article; Behavioural Ecology & Ecophysiology; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B000572J
|
“X-ray spectrometry”. Van Grieken RE page 13269 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Challenges in the electrochemical (bio)sensing of non-electroactive food and environmental contaminants”. Moro G, De Wael K, Moretto LM, Current opinion in electrochemistry 16, 57 (2019). http://doi.org/10.1016/J.COELEC.2019.04.019
Abstract: The electrochemical detection of non-electroactive contaminants can be successfully faced via the use of indirect detection strategies. These strategies can provide sensitive and selective responses often coupled with portable and user-friendly analytical tools. Indirect detection strategies are usually based on the change in the signal of an electroactive probe, induced by the presence of the target molecule at a modified electrode. This critical review aims at addressing the developments in indirect electro-sensing strategies for non-electroactive contaminants in food and environmental analysis in the last years (2017-2019). Emphasis is given to the strategy design, the electrode modifiers used and the feasibility of technological transfer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 4
DOI: 10.1016/J.COELEC.2019.04.019
|
“Electrochemical deposition of a copper carboxylate layer on copper as potential corrosion inhibitor”. Elia A, De Wael K, Dowsett M, Adriaens A, Journal of solid state electrochemistry 16, 143 (2011). http://doi.org/10.1007/S10008-010-1283-6
Abstract: Carboxylic acids and sodium carboxylates are used to protect metals against aqueous and atmospheric corrosion. In this paper, we describe the application of a layer of copper carboxylate on the surface of a copper electrode by means of cyclic voltammetry technique and tests which measure the corresponding resistance to aqueous corrosion. Unlike the soaking process, which also forms a film on the surface, the use of cyclic voltammetry allows one to follow the deposition process of the copper carboxylates onto the electrode. The modified electrodes have been characterised with infrared spectroscopy. In addition, the corrosion resistance of the film has been investigated using polarisation resistance and Tafel plot measurements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.316
Times cited: 8
DOI: 10.1007/S10008-010-1283-6
|
“LA-ICP-MS for Pu source identification at Mayak PA, the Urals, Russia”. Cagno S, Hellemans K, Lind OC, Skipperud L, Janssens K, Salbu B, Environmental science : processes &, impacts 16, 306 (2014). http://doi.org/10.1039/C3EM00531C
Abstract: Information on Pu in environmental samples is traditionally based on the determination of the 240+239PU activity via Alpha Spectrometry (AS). A large number of alpha spectrometry sources (planchettes) containing radiochemically separated Pu are therefore stored worldwide and are available for further analyses. These archive samples represent a resource from which valuable information on isotopic composition of alpha emitters including Pu can be obtained. The relative abundances of Pu isotopes can be used to trace specific Pu sources and characterize the relative contributions of different Pu sources in a sample. Thus, in addition to the total 239+240PU activity, determination of the Pu-240/Pu-239 ratio can provide valuable information on the nature of the Pu emitting sources. The Pu isotopic ratios can be determined by mass spectrometry techniques such as Sector Field Inductively Coupled Plasma Mass Spectrometry (SF-ICPMS) or Accelerator Mass Spectrometry (AMS) that require dissolution and complete destruction of the material deposited on the planchettes. In this study Laser Ablation (LA)-quadrupole-ICP-MS has been employed for the analysis of Pu-239/Pu-240 ratios from alpha-planchettes prepared from samples originating from the Mayak PA nuclear facility, Russia. The results are compared with data from AMS and show that the Pu-240/Pu-239 ratios obtained by LA-ICP-MS can be utilized to distinguish weapons-grade Pu from civil reprocessing sources. Moreover, isotope ratio mapping can also be performed across the planchettes, allowing e.g. the visualization of possible inhomogeneities in the Pu-isotope distribution on their surface. Thus, this solid sample technique can be applied to extract additional information from existing archives of samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.592
Times cited: 10
DOI: 10.1039/C3EM00531C
|
“Trace analysis allows to distinguish between Venetian and facon-de-Venise glass vessels of the 16th and 17th century”. de Raedt I, Janssens K, Veeckman J, Vincze L, Vekemans B, Jeffries T, Journal of analytical atomic spectrometry 16, 1012 (2001). http://doi.org/10.1039/B102597J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 49
DOI: 10.1039/B102597J
|
“The use of LA-ICP-MS for the characterization of the micro-heterogeneity of heavy metals in BCR CRM 680”. Kempenaers L, Bings NH, Jeffries TE, Vekemans B, Janssens K, Journal of analytical atomic spectrometry 16, 1006 (2001). http://doi.org/10.1039/B102512K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/B102512K
|
“Analysis of biological materials from Tanzania by total reflection X-ray fluorescence (TXRF) analysis”. Koleleni YIA, Van Grieken R, Tanzania journal of science 16, 143 (1990)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Analysis of speleothems by electron and X-ray microprobes”. Kuczumow A, Vekemans B, Schalm O, Gysels K, Ro C-U, Van Grieken R, Journal of analytical atomic spectrometry 16, 90 (2001). http://doi.org/10.1039/B007725I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B007725I
|
“Analysis of X-ray spectra excited by X rays, electrons, and protons in monazite”. Annegarn HJ, Madiba CCP, Sellschop JPF, Genz H, Hoffmann DHH, Low W, Richter A, Van Grieken RE, Physical review : C : nuclear physics 16, 379 (1977). http://doi.org/10.1103/PHYSREVC.16.379
Abstract: Mineral monazite from Malaysia has been investigated by energy dispersive x-ray analysis employing three different methods: x-ray, relativistic electron and proton induced excitation. An upper limit of 15 ppm has been placed on the possible concentration of the superheavy element with Z=126.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1103/PHYSREVC.16.379
|
“Einfluss verschiedener Silbersalze auf die Farbintensität von Silbergelb : analytische Untersuchungen”. De Vis K, Jembrih-Simbürger D, Schalm O, Schreiner M, Caen J, Zeitschrift für Kunsttechnologie und Konservierung 16, 147 (2002)
Keywords: A2 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|