“The analysis of volatile siloxanes in waste activated sludge”. Dewil R, Appels L, Baeyens J, Van Vaeck L, Buczyńska A, Talanta 74, 14 (2007). http://doi.org/10.1016/J.TALANTA.2007.05.041
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.05.041
|
“The elemental chemistry of sediments in the Krishna River basin, India”. Ramesh R, Subramanian V, Van Grieken R, Van 't dack L, Chemical geology 74, 331 (1989). http://doi.org/10.1016/0009-2541(89)90042-9
Abstract: Composition of bed, core and suspended sediments collected from Krishna River sediments were studied and the observations are discussed in the light of other Indian rivers, world's average river suspended particles, surficial rock and soils. The contents of V, Cr, Co, Ni, Cu and Zn in the suspended particles are higher in the Krishna River than in the world's average, indicating pollution inputs. Suspended sediments are enriched (5 to 10 times) in all the elements considered relative to bed sediments. Downstream profile and metal/Al ratios of the elements indicate that the mobility of elements within the basin is controlled by basin geology, size and mineralogical characteristics. Good correlations observed for a number of elements point out to their common sink in the clay fraction of the sediments. There is no systematic variation with depth for the major elements and most of the elements are considerably higher compared to estuarine or Bay of Bengal sediments.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0009-2541(89)90042-9
|
“Recombination reactions and geometry effects in laser microprobe mass analysis studied with 12C/13C bilayers”. Bruynseels F, Van Grieken R, International journal of mass spectrometry and ion processes 74, 161 (1986). http://doi.org/10.1016/0168-1176(86)85003-0
Abstract: Bilayers of carbon, consisting of a layer of natural carbon and a second layer highly enriched in 13C, were investigated with the LAMMA 500-® instrument. When such a bilayer is perforated by the laser beam, comparable amounts of 12C and 13C are evaporated and partly ionized so that geometry effects and recombination reactions during laser-induced ionization can straightforwardly be studied.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0168-1176(86)85003-0
|
“X-ray spectrometry”. Szalóki I, Török SB, Injuk J, Van Grieken RE, Analytical chemistry 74, 2895 (2002). http://doi.org/10.1021/AC020241K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC020241K
|
“Argentinean prehistoric pigments' study by combined SEM/EDX and molecular spectroscopy”. Darchuk L, Tsybrii Z, Worobiec A, Vázquez C, Palacios OM, Stefaniak EA, Gatto Rotondo G, Sizov F, Van Grieken R, Spectrochimica acta: part A: molecular and biomolecular spectroscopy 75, 1398 (2010). http://doi.org/10.1016/J.SAA.2010.01.006
Abstract: Composition of the prehistoric pigments (from Carriqueo rock shelter, Rio Negro province, Argentina) has been analysed by means of molecular spectroscopy (Fourier transform infrared (FTIR) and micro-Raman) and scanning electron microscopy (SEM) coupled to an energy-dispersive X-ray spectrometer (EDS). Red and yellow pigments were recognized as red and yellow ochre. The matrix of the pigments is composed of one or more substances. According to the matrix composition yellow and red pigments were also divided into two groupsi.e. those containing kaolinite or sulphates. Green pigment was detected as green earth, made up of celadonite as a chromophore.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.SAA.2010.01.006
|
“Efficient separation of acetate and formate by ion chromatography: application to air samples in a cultural heritage environment”. Kontozova-Deutsch V, Krata A, Deutsch F, Bencs L, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 75, 418 (2008). http://doi.org/10.1016/J.TALANTA.2007.11.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.11.025
|
“Minimum requirements for reporting analytical data for environmental samples”. Egli H, Dassenakis M, Garelick H, Van Grieken R, Peijnenburg WJGM, Klasinc L, Kördel W, Priest N, Tavares T, Pure and applied chemistry 75, 1097 (2003). http://doi.org/10.1351/PAC200375081097
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1351/PAC200375081097
|
“A Monte Carlo program for quantitative electron-induced x-ray analysis of individual particles”. Ro C-U, Osán J, Szalóki I, de Hoog J, Worobiec A, Van Grieken R, Analytical chemistry 75, 851 (2003). http://doi.org/10.1021/AC025973R
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC025973R
|
“An expert system for chemical speciation of individual particles using low-Z particle electron probe X-ray microanalysis data”. Ro C-U, Kim HK, Van Grieken R, Analytical chemistry 76, 1322 (2004). http://doi.org/10.1021/AC035149I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC035149I
|
“Three-dimensional trace element analysis by confocal X-ray microfluorescence imaging”. Vincze L, Vekemans B, Brenker FE, Falkenberg G, Rickers K, Somogyi A, Kersten M, Adams F, Analytical chemistry 76, 6786 (2004). http://doi.org/10.1021/AC049274L
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC049274L
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 76, 3445 (2004). http://doi.org/10.1021/AC0400820
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC0400820
|
“Elemental and ionic components of atmospheric aerosols and associated gaseous pollutants in and near Dar es Salaam, Tanzania”. Mmari AG, Potgieter-Vermaak SS, Bencs L, McCrindle RI, Van Grieken R, Atmospheric environment : an international journal 77, 51 (2013). http://doi.org/10.1016/J.ATMOSENV.2013.04.061
Abstract: Elemental and water-soluble ionic compounds (WSICs) of atmospheric aerosols (total suspended particulate TSP) and some gaseous pollutants (SO2, NO2 and O3) from a coastal, semi-urban and rural site in and near Dar es Salaam, Tanzania were investigated during dry and wet seasons of January 2005November 2007. Na+, Ca2+, SO42−, NO3− and Cl− made up the dominant fraction of WSICs during the dry season with average concentrations ranging from non-detectable (n.d.)5.4, 0.262.6, 0.7414.7, 0.41.5 and 1.13.4 μg m−3, respectively, while in the wet season, from n.d. up to 1.7, 1.2, 4.4, 2.1 and 3.0 μg m−3, respectively. The total air concentrations of the detected elements (Al, Si, S, Cl, K, Ca, Fe and Zn) showed seasonal and site-specific variation in the range of 7.526.6 with an average of 14.5 μg m−3. Most of the air concentrations of pollutants were observed to decrease with increasing distance from the coastal site, which is under urban and industrial pollutant emissions. Sulphur and nitrogen oxidation ratios during the dry season ranged from 0.08 to 0.91 and 0.013 to 0.049, respectively, while they were between 0.090.65 and 0.0020.095, respectively, in the wet season. These values indicate the photochemical oxidation of SO2 and a high extent of NO3−formation in the atmosphere. Neutralization ratios revealed the presence of acidic SO42− and NO3− aerosols. Principal component analysis identified sea spray, local combustion, vehicular traffic, biomass burning and re-suspended road dust as dominant sources of aerosols at the studied coastal and semi-urban sites. However, at the rural site, besides sea spray, crustal sources, soil dust re-suspension and long-range transport are the possible origins of suspended particulates.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2013.04.061
|
“Quantitative determination of low-Z elements in single atmospheric particles on boron substrates by automated scanning electron microscopy: energy-dispersive X-ray spectrometry”. Choël M, Deboudt K, Osán J, Flament P, Van Grieken R, Analytical chemistry 77, 5686 (2005). http://doi.org/10.1021/AC050739X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC050739X
|
“In vivo investigation of the distribution and the local speciation of selenium in Allium cepa L. by means of microscopic X-ray absorption near-edge structure spectroscopy and confocal microscopic X-ray fluorescence analysis”. Bulska E, Wysocka IA, Wierzbicka MH, Proost K, Janssens K, Falkenberg G, Analytical chemistry 78, 7616 (2006). http://doi.org/10.1021/AC060380S
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 56
DOI: 10.1021/AC060380S
|
“Oxidation states of uranium in depleted uranium particles from Kuwait”. Salbu B, Janssens K, Lind OC, Proost K, Gijsels L, Danesi PR, Journal of environmental radioactivity 78, 125 (2004). http://doi.org/10.1016/J.JENVAD.2004.04.001
Abstract: The oxidation states of uranium in depleted uranium (DU) particles were determined by synchrotron radiation based mu-XANES, applied to individual particles isolated from selected samples collected at different sites in Kuwait. Based on scanning electron microscopy with X-ray microanalysis prior to mu-XANES, DU particles ranging from sub-microns to several hundred micrometers were observed. The.median particle size depended on sources and sampling sites; small-sized particles (median 13 mum) were identified in swipes taken from the inside of DU penetrators holes in tanks and in sandy soil collected below DU penetrators, while larger particles (median 44 mum) were associated with fire in a DU ammunition storage facility. Furthermore, the U-236/U-235 ratios obtained from accelerator mass spectrometry demonstrated that uranium in the DU particles originated from reprocessed fuel (about 10(-2) in DU from the ammunition facility, about 10(-3) for DU in swipes). Compared to well-defined standards, all investigated DU particles were oxidized. Uranium particles collected from swipes were characterized as UO2, U3O8 or a mixture of these oxidized forms, similar to that observed in DU affected areas in Kosovo. Uranium particles formed during fire in the DU ammunition facility were, however, present as oxidation state +5 and +6, with XANES spectra similar to solid uranyl standards. Environmental or health impact assessments for areas affected by DU munitions should therefore take into account the presence of respiratory UO2, U3O8 and even UO3 particles, their corresponding weathering rates and the subsequent mobilisation of U from oxidized DU particles. (C) 2004 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.31
DOI: 10.1016/J.JENVAD.2004.04.001
|
“Air-pollution-induced chemical decay of a sandy-limestone cathedral in Belgium”. Leysen L, Roekens E, Van Grieken R, The science of the total environment 78, 263 (1989). http://doi.org/10.1016/0048-9697(89)90038-7
Abstract: Different trace- and microanalytical techniques were used in an extensive study to elucidate the chemical deterioration process of the sandy-limestone St Rombouts Cathedral in Mechelen, Belgium. Samples of stones, mortar joints, slates, atmospheric aerosols and gases, total and wet deposition, and water that had run down the cathedral walls, were all thoroughly characterized. At the east side, usually not exposed to precipitation, a 3001000-μm thick outer crust of microcrystalline gypsum was observed, while at the west side, this surface layer was mostly eroded away due to precipitation. At the north and south sides, the crust contains varying amounts of gypsum and calcite. The gypsum is mostly present in a bar-shaped morphology and carbonaceous fly-ash particles were rarely found in the weathering crust. Local stone characteristics seem to be extremely important in relation to the gypsum content of the crust; black samples always have a much higher sulphate content than the corresponding white samples, irrespective of the predominant direction of orientation. The relative contribution of nitrogen- and chlorine-containing pollutants to the total decay process is much smaller than that of sulphur-containing pollutants. Deposition samples collected at the site of the cathedral mostly had a pH of > 5.6, due to the neutralization of the rainwater by alkaline atmospheric constituents. Runoff water and washdown water were enriched in all ions, especially Ca2+ and SO42−, indicating that, indeed, gypsum is the most important weathering product. The suspension in deposition samples and black-well leaching water was highly enriched in silicon-containing particles, while runoff water and white-wall leaching water contained a predominant calcium-rich suspension.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(89)90038-7
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 78, 4069 (2006). http://doi.org/10.1021/AC060688J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC060688J
|
“Determination of platinum, palladium, and rhodium in automotive catalysts using high-energy secondary target X-ray fluorescence spectrometry”. van Meel K, Smekens A, Behets M, Kazandjian P, Van Grieken R, Analytical chemistry 79, 6383 (2007). http://doi.org/10.1021/AC070815R
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC070815R
|
“Determination of the cd-bearing phases in municipal solid waste and Biomass single fly ash particles using SR-mu XRF Spectroscopy”. Camerani MC, Somogyi A, Vekemans B, Ansell S, Simionovici AS, Steenari B-M, Panas I, Analytical chemistry 79, 6496 (2007). http://doi.org/10.1021/AC070206J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC070206J
|
“Single-run ion chromatographic separation of inorganic and low-molecular-mass organic anions under isocratic elution: application to environmental samples”. Krata A, Kontozova-Deutsch V, Bencs L, Deutsch F, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 79, 16 (2009). http://doi.org/10.1016/J.TALANTA.2009.02.044
Abstract: For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 ìm particle size), Allsep A-2 (7 ìm particle size), and IC SI-50 4E (5 ìm particle size). A complete baseline separation for all analyzed anions (i.e., F−, acetate, formate, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F−, Ac−, For−, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2009.02.044
|
“Visualization of a lost painting by Vincent van Gogh using synchrotron radiation based X-ray fluorescence elemental mapping”. Dik J, Janssens K, van der Snickt G, van der Loeff L, Rickers K, Cotte M, Analytical chemistry 80, 6436 (2008). http://doi.org/10.1021/AC800965G
Abstract: Vincent van Gogh (1853−1890), one of the founding fathers of modern painting, is best known for his vivid colors, his vibrant painting style, and his short but highly productive career. His productivity is even higher than generally realized, as many of his known paintings cover a previous composition. This is thought to be the case in one-third of his early period paintings. Van Gogh would often reuse the canvas of an abandoned painting and paint a new or modified composition on top. These hidden paintings offer a unique and intimate insight into the genesis of his works. Yet, current museum-based imaging tools are unable to properly visualize many of these hidden images. We present the first-time use of synchrotron radiation based X-ray fluorescence mapping, applied to visualize a womans head hidden under the work Patch of Grass by Van Gogh. We recorded decimeter-scale, X-ray fluorescence intensity maps, reflecting the distribution of specific elements in the paint layers. In doing so we succeeded in visualizing the hidden face with unprecedented detail. In particular, the distribution of Hg and Sb in the red and light tones, respectively, enabled an approximate color reconstruction of the flesh tones. This reconstruction proved to be the missing link for the comparison of the hidden face with Van Goghs known paintings. Our approach literally opens up new vistas in the nondestructive study of hidden paint layers, which applies to the oeuvre of Van Gogh in particular and to old master paintings in general.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 178
DOI: 10.1021/AC800965G
|
“High-energy polarized-beam energy-dispersive X-ray fluorescence analysis combined with activated thin layers for cadmium determination at trace levels in complex environmental liquid samples”. Marguí, E, Fontàs C, van Meel K, Van Grieken R, Queralt I, Hidalgo M, Analytical chemistry 80, 2357 (2008). http://doi.org/10.1021/AC7018427
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC7018427
|
“Leaching of nutrients and trace metals from aerosol samples: a comparison between a re-circulation and an ultrasound system”. Eyckmans K, Zhang J, de Hoog J, Joos P, Van Grieken R, International journal of environmental analytical chemistry 80, 227 (2001). http://doi.org/10.1080/03067310108044372
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067310108044372
|
“Characterization of a degraded cadmium yellow (CdS) pigment in an oil painting by means of synchrotron radiation based X-ray techniques”. van der Snickt G, Dik J, Cotte M, Janssens K, Jaroszewicz J, de Nolf W, Groenewegen J, van der Loeff L, Analytical chemistry 81, 2600 (2009). http://doi.org/10.1021/AC802518Z
Abstract: On several paintings of James Ensor (1860−1949), a gradual fading of originally bright yellow areas, painted with the pigment cadmium yellow (CdS), is observed. Additionally, in some areas exposed to light, the formation of small white-colored globules on top of the original paint surface is observed. In this paper the chemical transformation leading to the color change and to the formation of the globules is elucidated. Microscopic X-ray absorption near-edge spectroscopy (ì-XANES) experiments show that sulfur, originally present in sulfidic form (S2−), is oxidized during the transformation to the sulfate form (S6+). Upon formation (at or immediately below the surface), the highly soluble cadmium sulfate is assumed to be transported to the surface in solution and reprecipitates there, forming the whitish globules. The presence of cadmium sulfate (CdSO4·2H2O) and ammonium cadmium sulfate [(NH4)2Cd(SO4)2] at the surface is confirmed by microscopic X-ray diffraction measurements, where the latter salt is suspected to result from a secondary reaction of cadmium sulfate with ammonia. Measurements performed on cross sections reveal that the oxidation front has penetrated into the yellow paint down to ca. 1−2 ìm. The morphology and elemental distribution of the paint and degradation product were examined by means of scanning electron microscopy equipped with an energy-dispersive spectrometer (SEM-EDS) and synchrotron radiation based micro-X-ray fluorescence spectrometry (SR ì-XRF). In addition, ultraviolet-induced visible fluorescence photography (UIVFP) revealed itself to be a straightforward technique for documenting the occurrence of this specific kind of degradation on a macroscale by painting conservators.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 91
DOI: 10.1021/AC802518Z
|
“Characterization of uranium and plutonium containing particles originating from the nuclear weapons accident in Thule, Greenland, 1968”. Lind OC, Salbu B, Janssens K, Proost K, Dahlgaard H, Journal of environmental radioactivity 81, 21 (2005). http://doi.org/10.1016/J.JENVRAD.2004.10.013
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.31
Times cited: 37
DOI: 10.1016/J.JENVRAD.2004.10.013
|
“Elemental abundance variation with particle-size in north florida aerosols”. Johansson TB, Van Grieken RE, Winchester JW, Journal of geophysical research 81, 1039 (1976). http://doi.org/10.1029/JC081I006P01039
Abstract: A nonurban base line has been established for nine trace element constituents of aerosol particles as a function of particle size at ground level sampling stations in north Florida up to 50 km from the Gulf of Mexico. The particle size range 0.25- to >4-μm aerodynamic diameter was investigated by cascade impactor sampling and elemental analysis by proton-induced X ray emission. By using a strategy of sampling at urban, forest, and coastal locations and by choosing approximately 48-hour sample averaging intervals the potential dependence of the base line levels both on local pollution and natural sources and on local particle size specific aerosol removal processes could be evaluated. It is found that elements contained in the largest particles, especially those of >4 μm, display the greatest degree of average concentration difference between sites, a result suggesting short atmospheric residence times and the importance of local dispersion sources and atmospheric cleansing processes in regulating the particle concentrations in air. Elements contained in particles of <2-μm diameter show little average concentration difference between sites unless they are influenced by local pollution sources, a finding suggesting that their concentrations in air are regulated by large-scale sources and transport processes. Sulfur in the smallest particles shows a marked constancy of concentration, but it may be modified in the largest particle size ranges in relation to proximity to the seacoast. No evidence is found for dependence of particulate sulfur concentrations on local pollution sources. K, Ca, Ti, Fe, and Zn appear to be regulated in the main by terrestrial source processes, and Cl by marine source processes, but Br and Pb appear to be accounted for adequately by assuming automotive fuel combustion as their major source. Limited data obtained for V indicate that it may vary considerably with fluctuations in aerosol transport from oil-fired electric power plant sources in the region. Limited additional data also suggest that Mn is derived from sources of natural terrestrial composition. In view of these findings, certain criteria may be set for the design of a meaningful nonurban aerosol monitoring network.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1029/JC081I006P01039
|
“Method for the determination of Pd-catalyst residues in active pharmaceutical ingredients by means of high-energy polarized-beam energy dispersive X-ray fluorescence”. Marguí, E, van Meel K, Van Grieken R, Buendía A, Fontás C, Hidalgo M, Queralt I, Analytical chemistry 81, 1404 (2009). http://doi.org/10.1021/AC8021373
Abstract: In medicinal chemistry, Pd is perhaps the most-widely utilized precious metal, as catalyst in reactions which represent key transformations toward the synthesis of new active pharmaceutical ingredients (APIs). The disadvantage of this metal-catalyzed chemistry is that expensive and toxic metal residues are invariably left bound to the desired product. Thus, stringent regulatory guidelines exist for the amount of residual Pd that a drug candidate is allowed to contain. In this work, a rapid and simple method for the determination of Pd in API samples by high-energy polarized-beam energy dispersive X-ray fluorescence spectrometry has been developed and validated according to the specification limits of current legislation (10 mg kg−1 Pd) and the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH guidelines). Sample and calibration standards preparation includes a first step of homogenization and then, in a second step, the pressing of the powdered material into pellets without any chemical treatment. The use of several synthetic calibration standards made of cellulose to simulate the API matrix appears to be an effective means to obtain reliable calibration curves with a good spread of data points over the working range. With the use of the best measuring conditions, the limit of detection (0.11 mg kg−1 Pd) as well as the limit of quantitation (0.37 mg kg−1 Pd) achieved meet rigorous requirements. The repeatability of the XRF measurement appeared to be less than 2%, while the precision of the whole method was around 7%. Trueness was evaluated by analyzing spiked API samples at the level of the specification limit and calculating the recovery factor, which was better than 95%. To study the applicability of the developed methodology for the intended purpose, three batches of the studied API were analyzed for their Pd content, and the attained results were comparable to those obtained by the daily routine method (acid digestion plus atomic spectroscopy) used in most pharmaceutical laboratories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC8021373
|
“Chemical composition of riverine suspended matter and sediments from the Indian sub-continent”. Dekov V, Subramanian V, Van Grieken R, Mitteilungen aus dem Geologisch-Paläontologischen Institut der Universität Hamburg 82, 99 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Voltammetric behaviour of drotaverine hydrochloride in surfactant media and its enhancement determination in Tween-20”. Jain R, Vikas, Rather JA, Colloids and surfaces: B : biointerfaces 82, 333 (2011). http://doi.org/10.1016/J.COLSURFB.2010.09.005
Abstract: Simple, sensitive and rapid adsorptive voltammetric behaviour of drotaverine hydrochloride onto the HMDE has been explored and validated in surfactant media by using cyclic, differential pulse and square-wave voltammetry. Addition of Tween-20 to the drotaverine hydrochloride containing electrolyte enhances the reduction current signal. The voltammograms of the drug with Tween-20 in phosphate buffers of pH 2.511.0 exhibit a single well defined reduction peak which may be due to the reduction of Cdouble bond; length as m-dashC group. The cyclic voltammetric studies indicated the reduction of drotaverine hydrochloride at the electrode surface through two electron irreversible step and diffusion-controlled. The peak current showed a linear dependence with the drug concentration over the range 0.87.2 μg mL−1. The calculated LOD and LOQ are 1.8 and 6.0 ng mL−1 by SWCAdSV and 8.1 and 27.2 ng mL−1 by DPCAdSV, respectively. The procedure was applied to the assay of the drug in tablet form with mean percentage recoveries of 100.2% with SWCAdSV and 99.7% with DPCAdSV. The validity of the proposed methods was further assessed by applying a standard addition technique.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.COLSURFB.2010.09.005
|
“Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of synchrotron X-ray spectromicroscopy and related methods : 1 : artificially aged model samples”. Monico L, van der Snickt G, Janssens K, de Nolf W, Miliani C, Verbeeck J, Tian H, Tan H, Dik J, Radepont M, Cotte M, Analytical chemistry 83, 1214 (2011). http://doi.org/10.1021/ac102424h
Abstract: On several paintings by artists of the end of the 19th century and the beginning of the 20th Century a darkening of the original yellow areas, painted with the chrome yellow pigment (PbCrO4, PbCrO4·xPbSO4, or PbCrO4·xPbO) is observed. The most famous of these are the various Sunflowers paintings Vincent van Gogh made during his career. In the first part of this work, we attempt to elucidate the degradation process of chrome yellow by studying artificially aged model samples. In view of the very thin (1−3 μm) alteration layers that are formed, high lateral resolution spectroscopic methods such as microscopic X-ray absorption near edge (μ-XANES), X-ray fluorescence spectrometry (μ-XRF), and electron energy loss spectrometry (EELS) were employed. Some of these use synchrotron radiation (SR). Additionally, microscopic SR X-ray diffraction (SR μ-XRD), μ-Raman, and mid-FTIR spectroscopy were employed to completely characterize the samples. The formation of Cr(III) compounds at the surface of the chrome yellow paint layers is particularly observed in one aged model sample taken from a historic paint tube (ca. 1914). About two-thirds of the chromium that is present at the surface has reduced from the hexavalent to the trivalent state. The EELS and μ-XANES spectra are consistent with the presence of Cr2O3·2H2O (viridian). Moreover, as demonstrated by μ-XANES, the presence of another Cr(III) compound, such as either Cr2(SO4)3·H2O or (CH3CO2)7Cr3(OH)2 [chromium(III) acetate hydroxide], is likely.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 113
DOI: 10.1021/ac102424h
|