“Do ICP-MS based methods fulfill the EU monitoring requirements for the determination of elements in our environment?”.Tirez K, Vanhoof C, Bronders J, Seuntjens P, Bleux N, Berghmans P, De Brucker N, Vanhaecke F, Environmental science : processes &, impacts 17, 2034 (2015). http://doi.org/10.1039/C5EM00289C
Abstract: Undoubtedly, the most important advance in the environmental regulatory monitoring of elements of the last decade is the widespread introduction of ICP-mass spectrometry (ICP-MS) due to standards developed by the European Committee for Standardization. The versatility of ICP-MS units as a tool for the determination of major, minor and trace elements (Al, As, Ba, Ca, Cd, Co, Cr, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Sn, Ti, V and Zn) in surface water, groundwater, river sediment, topsoil, subsoil, fine particulates and atmospheric deposition is illustrated in this paper. Ranges of background concentrations for major, minor and trace elements obtained from a regional case study (Flanders, Belgium) are summarized for all of these environmental compartments and discussed in the context of a harmonized implementation of European regulatory monitoring requirements. The results were derived from monitoring programs in support of EU environmental quality directives and were based on a selection of (non-polluted) background locations. Because of the availability of ICP-MS instruments nowadays, it can be argued that the main hindrance for meeting the European environmental monitoring requirements is no longer the technical feasibility of analysis at these concentration levels, but rather (i) potential contamination during sampling and analysis, (ii) too limited implementation of quality control programs, validating the routinely applied methods (including sampling and low level verification) and (iii) lack of harmonization in reporting of the chemical environmental status between the individual member states.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1039/C5EM00289C
|
“Urban soil exploration through multi-receiver electromagnetic induction and stepped-frequency ground penetrating radar”. Van de Vijver E, Van Meirvenne M, Vandenhaute L, Delefortrie S, De Smedt P, Saey T, Seuntjens P, Environmental science : processes &, impacts 17, 1271 (2015). http://doi.org/10.1039/C5EM00023H
Abstract: In environmental assessments, the characterization of urban soils relies heavily on invasive investigation, which is often insufficient to capture their full spatial heterogeneity. Non-invasive geophysical techniques enable rapid collection of high-resolution data and provide a cost-effective alternative to investigate soil in a spatially comprehensive way. This paper presents the results of combining multi-receiver electromagnetic induction and stepped-frequency ground penetrating radar to characterize a former garage site contaminated with petroleum hydrocarbons. The sensor combination showed the ability to identify and accurately locate building remains and a high-density soil layer, thus demonstrating the high potential to investigate anthropogenic disturbances of physical nature. In addition, a correspondence was found between an area of lower electrical conductivity and elevated concentrations of petroleum hydrocarbons, suggesting the potential to detect specific chemical disturbances. We conclude that the sensor combination provides valuable information for preliminary assessment of urban soils.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1039/C5EM00023H
|
“Characterization and analysis of the adsorption immobilization mechanism of \beta-galactosidase on metal oxide powders”. Satyawali Y, Van Roy S, Roevens A, Meynen V, Mullens S, Jochems P, Doyen W, Cauwenberghs L, Dejonghe W, RSC advances 3, 24054 (2013). http://doi.org/10.1039/C3RA45107K
Abstract: Immobilization of the enzymes plays a vital role in enhancing their applicability in a wide range of applications, thus ensuring the use of sustainable enzymatic processes over the conventional chemical processes on an industrial scale. This study provides the background information for the selection and screening of inorganic metal oxide (MO) powders for their use as fillers in mixed matrix membranes for enzyme immobilization as the future aim. A total of 13 MOs, ranging in size from 0.01 μm to <5 μm, were tested for their performance as a support for enzyme (β-galactosidase) immobilization via adsorption. Alumina appeared to be the best performing MO with the amount and activity of the immobilized enzyme being 64 mg g−1 and up to 288 U g−1, respectively. The amount of immobilized enzyme on alumina (α-Al2O3 C and γ-Al2O3) was >3 times higher than ZrO2 (used as a reference MO in this study). Upon heat treatment at 900 °C, up to 15%, 52% and 42% decline was observed in the amount of immobilized enzyme in case of alumina metal oxides (MOs), ZrO2 and TiO2, respectively. The results suggested that both isoelectric point and surface area of the MO influence the immobilization. The most important observation in this study was that the bonding of the enzyme to the MO surface seems to be mediated by the bonding/interaction of the buffer to the enzyme.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1039/C3RA45107K
|
“Use of online water quality monitoring for assessing the effects of WWTP overflows in rivers”. Boënne W, Desmet N, Van Looy S, Seuntjens P, Environmental science : processes &, impacts 16, 1510 (2014). http://doi.org/10.1039/C3EM00449J
Abstract: The effects on river water quality of sewer overflows are not well known. Since the duration of the overflow is in the order of magnitude of minutes to hours, continuous measurements of water quality are needed and traditional grab sampling is unable to quantify the pollution loads. The objective of this paper was to demonstrate the applicability of high frequency measurements for assessing the impacts of waste water treatment plants on the water quality of the receiving surface water. In our in situ water quality monitoring setup, two types of multiparameter sensors mounted on a floating fixed platform were used to determine the dynamics of dissolved oxygen, specific conductivity, ammonium-N, nitrate-N and dissolved organic carbon downstream of a waste water treatment plant (WWTP), in combination with data on rainfall, river discharge and WWTP overflow discharge. The monitoring data for water quantity and water quality were used to estimate the pollution load from waste water overflow events and to assess the impact of waste water overflows on the river water quality. The effect of sewer overflow on a small river in terms of N load was shown to be significant. The WWTP overflow events accounted for about 1/3 of the river discharge. The NH4-N loads during overflow events contributed 29% and 21% to the August 2010 and June 2011 load, respectively, in only 8% and 3% of the monthly time span. The results indicate that continuous monitoring is needed to accurately represent the effects of sewer overflows in river systems.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1039/C3EM00449J
|
“Enzyme immobilization on/in polymeric membranes : status, challenges and perspectives in biocatalytic membrane reactors (BMRs)”. Jochems P, Satyawali Y, Diels L, Dejonghe W, Green chemistry : cutting-edge research for a greener sustainable future 13, 1609 (2011). http://doi.org/10.1039/C1GC15178A
Abstract: Immobilization of enzymes is beneficial in terms of improving the process economics by enabling enzyme re-use and enhancing overall productivity and robustness. Increasingly, membranes are thought to be good supports for enzyme immobilization. These resulting biocatalytic membranes are integrated in reactors known as biocatalytic membrane reactors (BMRs) which enable the integration of biocatalysis and separation. Often the available commercial membranes require modifications to make them suitable for enzyme immobilization. Different immobilization techniques can be used on such suitable membranes, but no general rules exist for making a choice between them. Despite the advantages of BMR application, there are some issues which need to be addressed in order to achieve up-scaling of such systems. In this review, the different aspects of enzyme immobilization on membranes are discussed to show the complexity of this interdisciplinary technology. In addition, the existing issues which require further investigation are highlighted.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1039/C1GC15178A
|
“Improved radiographic methods for the investigation of paintings using laboratory and synchrotron X-ray sources”. Schalm O, Cabal A, van Espen P, Laquière N, Storme P, Journal of analytical atomic spectrometry 26, 1068 (2011). http://doi.org/10.1039/C0JA00242A
Abstract: It is generally known that radiographic inspection of 1517th century paintings can easily be done with a polychromatic X-ray source using a voltage between 20 kV and 40 kV in combination with classic X-ray films. Unfortunately, the spatial structure of numerous 19th and early 20th century paintings cannot be visualized with conventional radiography due to several reasons such as the use of lead white grounds or low absorbing pigments. Radiographic images are blurred or worse, they do not contain the picture of the painting. During the last decades, many technological innovations have been introduced in the field of radiography but their possibilities in cultural heritage have not been explored in full detail. In our investigation we used phosphor imaging plates, energy dispersive detectors and CCD-cameras in combination with synchrotron radiation and conventional X-ray tubes in order to improve the quality of radiographic images. Several promising techniques that could improve the quality of radiographs of paintings were identified.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/C0JA00242A
|
“Major ionic species in size-segregated aerosols and associated gaseous pollutants at a coastal site on the Belgian North Sea”. Horemans B, Krata A, Buczyńska AJ, Dirtu AC, van Meel K, Van Grieken R, Bencs L, Journal of environmental monitoring 11, 670 (2009). http://doi.org/10.1039/B815059A
Abstract: The chemical composition of airborne particulate matter (PM) was studied at a coastal region near De Haan, Belgium, during a winterspring and a summer campaign in 2006. The major ionic components of size-segregated PM, i.e. NH4+, Na+, K+, Mg2+, Ca2+, Cl-, NO3-, and SO42-, and related gaseous pollutants (SO2, NO2, NH3, HNO2, and HNO3) were monitored on a daily basis. Air mass backward-trajectories aided in evaluating the origin of the diurnal pollution load. This was characterised with high levels of fine secondary inorganic aerosols (NH4+, NO3-, and non-sea-salt SO42-) for continental air masses, and sea-salts as the dominant species in coarse maritime aerosols. Seasonal variations in the level of major ionic species were explained by weather conditions and the release of dimethyl sulfide from marine regions. This species was responsible for an increased sea-salt Cl- depletion during summer (56%), causing elevated levels of HCl. Neutralisation ratios for the coarse fraction (0.60.8) suggested a depleted NH4+ level, while that for the fine fraction (1.11.3) had definitely an excess of NH4+, formed by the neutralisation of HCl. The results of factor analysis and the extent of SO2 oxidation indicated that the major ionic species originated from both local and remote sources, classifying the Belgian coastal region as a combined sourcereceptor area of air pollution.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B815059A
|
“Sample damage during X-ray fluorescence analysis: case study on ammonium salts in atmospheric aerosols”. van Meel K, Worobiec A, Stranger M, Van Grieken R, Journal of environmental monitoring 10, 989 (2008). http://doi.org/10.1039/B807909A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1039/B807909A
|
“Mass and ionic composition of atmospheric fine particles over Belgium and their relation with gaseous air pollutants”. Bencs L, Ravindra K, de Hoog J, Rasoazanany EO, Deutsch F, Bleux N, Berghmans P, Roekens E, Krata A, Van Grieken R, Journal of environmental monitoring 10, 1148 (2008). http://doi.org/10.1039/B805157G
Abstract: Mass, major ionic components (MICs) of PM2.5, and related gaseous pollutants (SO2, NOx, NH3, HNO2, and HNO3) were monitored over six locations of different anthropogenic influence (industrial, urban, suburban, and rural) in Belgium. SO42-, NO3-, NH4+, and Na+ were the primary ions of PM2.5 with averages diurnal concentrations ranging from 0.44.5, 0.37.6, 0.94.9, and 0.41.2 µg m-3, respectively. MICs formed 39% of PM2.5 on an average, but it could reach up to 8098%. The SO2, NO, NO2, HNO2, and HNO3 levels showed high seasonal and site-specific fluctuations. The NH3 levels were similar over all the sites (26 µg m-3), indicating its relation to the evenly distributed animal husbandry activities. The sulfur and nitrogen oxidation ratios for PM2.5 point towards a low-to-moderate formation of secondary sulfate and nitrate aerosols over five cities/towns, but their fairly intensive formation over the rural Wingene. Cluster analysis revealed the association of three groups of compounds in PM2.5: (i) NH4NO3, KNO3; (ii) Na2SO4; and (iii) MgCl2, CaCl2, MgF2, CaF2, corresponding to anthropogenic, sea-salt, and mixed (sea-salt + anthropogenic) aerosols, respectively. The neutralization and cation-to-anion ratios indicate that MICs of PM2.5 appeared mostly as (NH4)2SO4 and NH4NO3 salts. Sea-salt input was maximal during winter reaching up to 12% of PM2.5. The overall average Cl-loss for sea-salt particles of PM2.5 at the six sites varied between 69 and 96% with an average of 87%. Principal component analysis revealed vehicular emission, coal/wood burning and animal farming as the dominating sources for the ionic components of PM2.5.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B805157G
|
“Airborne particulate matter and BTEX in office environments”. Horemans B, Worobiec A, Buczyńska A, van Meel K, Van Grieken R, Journal of environmental monitoring 10, 867 (2008). http://doi.org/10.1039/B804475A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1039/B804475A
|
“Application of high-energy polarised beam energy dispersive X-ray fluorescence spectrometry to cadmium determination in saline solutions”. van Meel K, Fontàs C, Van Grieken R, Queralt I, Hidalgo M, Marguí, E, Journal of analytical atomic spectrometry 23, 1034 (2008). http://doi.org/10.1039/B718382H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B718382H
|
“Processing of three-dimensional microscopic X-ray fluorescence data”. Vekemans B, Vincze L, Brenker FE, Adams F, Journal of analytical atomic spectrometry 19, 1302 (2004). http://doi.org/10.1039/B404300F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B404300F
|
“Characteristics of atomic absorption calibration curves with the transversely heated graphite furnace”. Bencs L, Szakács O, Szoboszlai N, Ajtony Z, Bozsai G, Journal of analytical atomic spectrometry 18, 105 (2003). http://doi.org/10.1039/B208198A
Abstract: Calibration curves with two quasi-linear sections ("double sloping'') were observed for the medium volatile elements, Cr and Cu, with the use of a SIMAA 6000 graphite furnace atomic absorption spectrometer under interrupted internal gas flow conditions. If a standard transversally heated graphite atomizer (THGA) tube was shortened by 0.5 mm at both of its ends, (i.e. the gaps were enlarged between graphite furnace housing and tube ends), a stronger declination of the calibration curves resulted. Elements with fairly high diffusion coefficients (>5.8 cm(2) s(-1)) and with short appearance time of their transients (<0.6 s), such as Cr and Cu, have shown the most characteristic sensitivity drop towards higher concentrations. This anomalous feature could be eliminated in three different ways; (1) by applying end-capped THGA tubes, (2) using mini-flow (50 cm(3) min(-1)) conditions during the atomization stage, and (3) by adding Pd-Mg chemical modifier. For the low volatile Mo and V, the calibration curves had no irregular shape. For Ag, Co, Cr, Cu, Mn and Ni, the mini-flow settings improved the linearity of the calibration curves and extended the upper limit of the linear calibration range by a factor of 1.5-2.0. The irregular characteristic of the analytical curves was interpreted as an increased vapour loss at higher analyte concentrations through the opened ends of the standard THGA tubes. This vapour loss was associated with the significantly diverse expulsion velocities of atoms, caused by the difference in temperature and concentration gradients, when evaporating amounts of analytes with more than one order of magnitude difference.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B208198A
|
“Analysis of speleothems by electron and X-ray microprobes”. Kuczumow A, Vekemans B, Schalm O, Gysels K, Ro C-U, Van Grieken R, Journal of analytical atomic spectrometry 16, 90 (2001). http://doi.org/10.1039/B007725I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B007725I
|
“Quantitative characterisation of the leaching of lead and other elements from glazed surfaces of historical ceramics”. Szalóki I, Braun M, Van Grieken R, Journal of analytical atomic spectrometry 15, 843 (2000). http://doi.org/10.1039/B000746N
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B000746N
|
“Spectrometric determination of silicon in food and biological samples: an interlaboratory trial”. van Dyck K, Robberecht H, van Cauwenbergh R, Deelstra H, Arnaud J, Willemyns L, Benijts F, Centeno JA, Taylor H, Soares ME, Bastos ML, Ferreira MA, d'Haese PC, Lamberts LV, Hoenig M, Knapp G, Lugowski SJ, Moens L, Riondato J, Van Grieken R, Claes M, Verheyen R, Clement L, Uytterhoeven M, Journal of analytical atomic spectrometry 15, 735 (2000). http://doi.org/10.1039/B000572J
Abstract: Accuracy and precision of silicon determination in biological matrices (serum, urine, water, beer and spinach) by spectrometric techniques (when necessary after acid destruction) were assessed by means of a collaborative interlaboratory trial. The trial was set up in accordance with ISO 5725-2 (1994). The relative overall repeatability standard deviation was acceptable. It varied between 4% for spinach powder (mean content: 176 mg kg(-1)) and 11% for serum (mean content: 5.33 mg L-1). On the other hand, the relative overall between-laboratory standard deviation was found to vary from a satisfactorily 15% for spinach after destruction (mean content: 3.32 mg L-1) to an unacceptable 107% for spinach powder (mean content: 176 mg kg(-1)). The overall conclusion of the trial was that silicon determination in biological matrices can properly be performed by spectrometric techniques. However, when sample pretreatment (i.e., acid destruction) is needed prior to silicon determination problems still remain.
Keywords: A1 Journal article; Behavioural Ecology & Ecophysiology; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B000572J
|
“Recent advances in the analysis of individual environmental particles: a review”. Jambers W, de Bock L, Van Grieken R, The analyst 120, 681 (1995). http://doi.org/10.1039/AN9952000681
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/AN9952000681
|
“Classification of mineral particles by nonlinear mapping of electron microprobe energy-dispersive X-ray spectra”. Treiger B, Bondarenko I, van Espen P, Van Grieken R, Adams F, The analyst 119, 971 (1994). http://doi.org/10.1039/AN9941900971
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1039/AN9941900971
|
“Quantification problems in light element determination by grazing emission X-ray fluorescence”. Kuczumow A, Claes M, Schmeling M, Van Grieken R, de Gendt S, Journal of analytical atomic spectrometry 15, 415 (2000). http://doi.org/10.1039/A908724I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A908724I
|
“Critical assessment and proposal for reconstruction of a grazing emission X-ray fluorescence instrument”. Kuczumow A, Schmeling M, Van Grieken R, Journal of analytical atomic spectrometry 15, 535 (2000). http://doi.org/10.1039/A908661G
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A908661G
|
“Elemental x-ray images obtained by grazing-exit electron probe microanalysis (GE-EPMA)”. Tsuji K, Nullens R, Wagatsuma K, Van Grieken RE, Journal of analytical atomic spectrometry 14, 1711 (1999). http://doi.org/10.1039/A905301H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A905301H
|
“Compositional distinctions between 16th century “Façon-de-Venise&rdquo, and Venetian glass vessels, excavated in Antwerp, Belgium”. Deraedt I, Janssens K, Veeckman J, Journal of analytical atomic spectroscopy 14, 483 (1999). http://doi.org/10.1039/A808385A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A808385A
|
“Modeling of photon scattering at high X-ray energies : experiment versus simulation”. Vincze L, Vekemans B, Janssens K, Adams F, Journal of analytical atomic spectrometry
T2 –, 15th International Congress on X-Ray Optics and Microanalysis (ICXOM), AUG 24-27, 1998, ANTWERP, BELGIUM 14, 529 (1999). http://doi.org/10.1039/A808040B
Abstract: The use of a detailed Monte Carlo simulation code for X-ray fluorescence spectrometers is demonstrated for calculating the outcome of X-ray scattering experiments in the incident energy range 40-80 keV. The code was validated by comparisons of experimental and simulated spectral distributions in the case of thick, homogeneous samples in which multiple photon scattering occurs with high probability. The experimental spectral distributions were collected at beamline BW5 of HASYLAB, Germany, where a highly energetic, monochromatic synchrotron beam is available. With respect to heterogeneous samples, the code was employed to evaluate the use of Rayleigh and Compton scatter signals for obtaining three dimensional information on the sample dark matrix composition.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A808040B
|
“Analyses of petrified wood by electron, X-ray and optical microprobes”. Kuczumov A, Vekemans B, Schalm O, Dorriné, W, Chevallier P, Dillmann P, Ro C-U, Janssens K, Van Grieken R, Journal of analytical atomic spectroscopy 14, 435 (1999). http://doi.org/10.1039/A806748A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A806748A
|
“The use of lead-glass capillaries for microfocusing of highly energetic (0-60 KeV) synchrotron radiation”. Janssens K, Vincze L, Vekemans B, Adams F, Haller M, Knöchel A, Journal of analytical atomic spectrometry 13, 339 (1998). http://doi.org/10.1039/A707700I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A707700I
|
“Microscopical X-ray fluorescence analysis and related methods with laboratory and synchrotron radiation sources”. Adams F, Janssens K, Snigirev A, Journal of analytical atomic spectrometry 13, 319 (1998). http://doi.org/10.1039/A707100K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A707100K
|
“Micro and surface analysis in archaeology”. Adams F, Adriaens A, Aerts A, de Raedt I, Janssens K, Schalm O, Journal of analytical atomic spectrometry 12, 257 (1997). http://doi.org/10.1039/A606091I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A606091I
|
“Examination of Vincent van Gogh's paintings and pigments by means of state-of-the-art analytical methods”. Janssens K, Alfeld M, Van der Snickt G, De Nolf W, Vanmeert F, Monico L, Legrand S, Dik J, Cotte M, Falkenberg G, van der Loeff L, Leeuwestein M, Hendriks E page 373 (2014).
Abstract: Recent studies in which X-ray beams of macroscopic to (sub) microscopic dimensions were used for non-destructive analysis and characterization of pigments, paint micro samples and/or entire paintings by Vincent van Gogh are concisely reviewed. The overview presented encompasses the use of laboratory and synchrotron radiation-based instrumentation and deals with the use of several variants of X-ray fluorescence (XRF) as a method of elemental analysis and imaging as well as with the combined use of X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Microscopic and macroscopic XRF are variants of the method that are well suited to visualize the elemental distribution of key elements, mostly metals, present in paint multi layers, either on the length scale from 1–100 μm inside micro samples taken from paintings or on the 1–100 cm length scale when the (subsurface) distribution of specific pigments in entire paintings is concerned. In the context of the characterization of van Gogh's pigments subject to natural degradation, the use of methods limited to elemental analysis or imaging usually is not sufficient to elucidate the chemical transformations that have taken place. However, at synchrotron facilities, combinations of μ-XRF with related methods such as μ-XAS and μ-XRD have proven themselves to be very suitable for such studies. Their use is often combined with microscopic Fourier transform infra-red (μ-FTIR) spectroscopy since this method delivers complementary information at more or less the same length scale as the X-ray microprobe techniques. Also in the context of macroscopic imaging of works of art, the complementary use of X-ray based and infra-red based imaging appears very promising; some recent developments are discussed.
Keywords: H2 Book chapter; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/9781839161957-00373
|
“Atomically dispersed ruthenium hydride on beta zeolite as catalysts for the isomerization of muconates”. Khalil I, Rigamonti MG, Janssens K, Bugaev A, Arenas Esteban D, Robijns S, Donckels T, Beydokhti MT, Bals S, De Vos D, Dusselier M, Nature Catalysis 7, 921 (2024). http://doi.org/10.1038/S41929-024-01205-5
Abstract: Searching for sustainable polymers requires access to biomass-based monomers. In that sense, glucose-derived cis,cis-muconic acid stands as a high-potential intermediate. However, to unlock its potential, an isomerization to the value-added trans,trans-isomer, trans,trans-muconic acid, is required. Here we develop atomically dispersed low-loaded Ru on beta zeolite catalysts that produce trans,trans-muconate in ethanol with total conversion (to equilibrium) and a selectivity of >95%. We reach very high turnovers per Ru and productivity rates of 427 mM h(-1) (similar to 85 g l(-1) h(-1)), surpassing the bio-based cis,cis-muconic acid production rates by an order of magnitude. By coupling isomerization to Diels-Alder cycloaddition, terephthalate intermediates are produced in around 90% yields, circumventing the isomer equilibrium. Isomerization is promoted by Ru hydride species where the hydrides are generated from the alcohol solvent, as evidenced by Fourier transform infrared spectroscopy. Beyond isomerization, the Ru-zeolite and its hydride-forming capacity could be of use as a heterogeneous catalyst for other hydride chemistries, demonstrated by a successful hydride transfer hydrogenation.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 37.8
DOI: 10.1038/S41929-024-01205-5
|
“Voltammetric drug testing makes sense at the border”. Van Echelpoel R, De Wael K, Nature Reviews Chemistry , 1 (2024). http://doi.org/10.1038/S41570-023-00571-1
Abstract: The European BorderSens project leverages voltammetric sensors, developed with end-users' input, to rapidly and accurately detect illicit drugs. By embracing practicalities and validation, this technology has the potential to combat the illicit drug problem.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1038/S41570-023-00571-1
|