|
“Atmospheric concentrations and deposition of heavy metals over the North Sea: a literature review”. Injuk J, Van Grieken R, Journal of atmospheric chemistry 20, 179 (1995). http://doi.org/10.1007/BF00696557
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00696557
|
|
|
“2,2′-Diaminodiethylamine cellulose powder for trace metal preconcentrations from water”. Reggers C, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 317, 520 (1984). http://doi.org/10.1007/BF00511918
Abstract: Cellulose powder with 2,2′-diaminodiethylamine (DEN) functional groups exhibits efficient complexation of transition metal cations. Collection yields above 85 % are obtained up to a chelation capacity of 1.5 meq per gram. Since a good collection is obtained for a pH up from 5, no pH adjustments have to be made for natural water samples. The cellulose-DEN powder is insensitive to abundant substances like alkali and alkaline earth ions, and humic matter. Some cations can be eluted efficiently in a small volume of HNO3. Blank concentration levels from the cellulose-DEN powder are reported.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00511918
|
|
|
“Total analysis of plant material and biological tissue by spark source mass spectrometry”. Verbueken A, Michiels E, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 309, 300 (1981). http://doi.org/10.1007/BF00488606
Abstract: Analysis of biological material by spark source mass spectrometry is reported. Preliminary studies mainly based upon the analysis of the NBS standard reference material SRM-1571 (Orchard Leaves) are described. Attention is drawn to the importance of a suitable sample preparation method. The advantages of a wet digestion technique in a Teflon bomb are discussed and its use is justified by the satisfactory overall analysis precision of about 20%.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00488606
|
|
|
“Analysis of geothermal waters by spark source mass spectrometry”. Vandelannoote R, Blommaert W, Gijbels R, van Grieken R, Fresenius' Zeitschrift für analytische Chemie 309, 291 (1981). http://doi.org/10.1007/BF00488604
Abstract: Although the analysis of thermal water by spark-source mass spectrometry (SSMS) is rather timeconsuming, it allows the detection of about 20 elements of geochemical interest down to the ppb-level. A physical preconcentration is proposed in order to collect elements having quite different chemical properties, e.g. alkalis, transition elements, and elements occurring in anionic form. The relative sensitivity factors appear to be rather independent of the salt content of the graphite electrodes. Contrary to neutron activation analysis, SSMS has a quite uniform elemental sensitivity, and allows to determine elements for which neutron activation is not suitable, e.g. Sn and Pb. The precision of SSMS is however by a factor of about 2 worse than that obtained for neutron activation.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 8
DOI: 10.1007/BF00488604
|
|
|
“Elemental composition of aircraft-sampled aerosols above the Southern Bight of the North Sea”. Rojas CM, Van Grieken R, Maenhaut W, Water, air and soil pollution 71, 391 (1993). http://doi.org/10.1007/BF00480557
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00480557
|
|
|
“Energy-dispersive X-ray spectrometry : present state and trends”. Van Grieken R, Markowicz A, Török S, Fresenius' Zeitschrift für analytische Chemie 324, 825 (1986). http://doi.org/10.1007/BF00473177
Abstract: Recent development, present state and expected future developments in energy-dispersive X-ray spectrometry are discussed. Attention is paid to the improvements in analytical selectivity, sensitivity, detection limit, quantitative character and applicability range, which are the result of new or better excitation sources, detectors, instrument design, automation, computer software and theoretical developments.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00473177
|
|
|
“Matrix effects and analysis of biological material by spark source mass spectrometry”. Vos L, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 321, 32 (1985). http://doi.org/10.1007/BF00464483
Abstract: Spark-source mass spectrometric analyses of synthetic simulated biological samples were performed to determine the importance of matrix effects. A correlation between the variation of the relative sensitivity coefficients (RSC's) and the spark plasma composition, hence plasma temperature, was found. The determined RSC's were used in the analysis of four biological standard reference materials. An accuracy of 1013% and detection limits between 0.005 and 0.5 ppm were obtained during analysis under normal conditions.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00464483
|
|
|
“Trace metal analysis of sediments and particulate matter in sea water by energy-dispersive X-ray fluorescence”. Vanderstappen M, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 282, 25 (1976). http://doi.org/10.1007/BF00443774
Abstract: The capability of energy-dispersive X-ray fluorescence was investigated for fast and simple chemical analysis of trace elements in sediments and particulate matter in sea water. Nuclepore 0.4 μm pore-size membranes are recommended as optimal filters for a straightforward collection of suspended material. The collection of suspended trace metals by filtration seemed to give a sufficiently homogeneous filter load (s% <2.5). Data are presented on the concentrations of K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Rb and Sr with a fair precision (s% < 5.6) and accuracy.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00443774
|
|
|
“Micro-determination of zirconium-hafnium ratios in zircons by proton induced X-ray emission”. Van Grieken RE, Johansson TB, Winchester JW, Odom L, Fresenius' Zeitschrift für analytische Chemie 275, 343 (1975). http://doi.org/10.1007/BF00437765
Abstract: The zirconium/hafnium ratios of zircons are determined using proton induced X-ray emission. Submilligram samples, imbedded in a starch layer and deposited on a 50 μg/cm2 polystyrene carrier, are irradiated for 1020 min with a 5 nA beam of 3.7 MeV protons, while the Hf-Lβ and Zr-Kα X-rays are counted with a Si(Li) detector. The standard deviation per analysis is in the 36 % range. Only few interferences are possible. To eliminate errors due to absorption effects the zircon layer thickness should be above 40 μm or reproducibly thin samples should be employed. Measuring the Hf-Lβ/Hf-Lα ratio for samples and standards might provide a practical check for the absence of absorption errors. The sensitivity is so favourable that, in practice, the minimal sample size is only limited by the minimal amount that can be handled properly.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00437765
|
|
|
“Quantitative characterization of individual particle surfaces by fractal analysis of scanning electron microscope images”. van Put A, Vertes A, Wegrzynek D, Treiger B, Van Grieken R, Fresenius' journal of analytical chemistry 350, 440 (1994). http://doi.org/10.1007/BF00321787
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00321787
|
|
|
“Chemistry of precipitation near a limestone building”. Roekens E, Komy Z, Leysen L, Veny P, Van Grieken R, Water, air and soil pollution 38, 273 (1988). http://doi.org/10.1007/BF00280759
Abstract: A total of 82 samples of wet and total deposition were sampled near the limestone cathedral at Mechelen, Belgium, which is presently being affected seriously by air pollution, and at a reference site. Most of these samples were analyzed for 10 major and 7 trace ions in solution and for 15 elements in suspension. It appeared that calcite, released from the building, effectively neutralizes the rainwater in the near vicinity and produces high Ca and bicarbonate concentrations. Heavy metal concentrations are hardly affected by the building.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00280759
|
|
|
“A methodology to monitor the pollution impact on historic buildings surfaces : the TeACH project”. Bernardi A, Becherini F, Bonazza A, Van Grieken R, et al, Lecture notes in computer science
T2 –, Progress in Cultural Heritage Preservation : proceedings of EUROMED-2012, the 4th International Conference on Cultural Heritage / Ioannides, M. [edit.], et al. , 765 (2012). http://doi.org/10.1007/978-3-642-34234-9
Abstract: The available scenarios of pollutant trends in Europe indicate that the effect of industrial, domestic and transport emissions on corrosion and soiling will continue to constitute a serious threat to Cultural Heritage. Such effects require improved methods for a more accurate diagnosis, monitoring and assessment of the damage. Within this framework, the monitoring methodology applied within the European project TeACH (Technologies and tools to prioritize assessment and diagnosis of air pollution impact on immovable and movable cultural heritage) (2008-2012) allows to assess the impact of the main pollutants on historic buildings. As a part of this approach, a new kit able to monitor the environmental parameters critical for the conservation of architectural surfaces and to evaluate the related damage in terms of surface color change was developed. The monitoring methodology described in the present paper has valuable application potential in the definition of preventive conservation strategies for a wide range of heritage assets.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/978-3-642-34234-9
|
|
|
“Comprehensive microanalytical study of welding aerosols with x-ray and Raman based methods”. Worobiec A, Stefaniak EA, Kiro S, Oprya M, Bekshaev A, Spolnik Z, Potgieter-Vermaak SS, Ennan A, Van Grieken R, X-ray spectrometry 36, 328 (2007). http://doi.org/10.1002/XRS.979
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.979
|
|
|
“Speciation of selected metals in aerosol samples by TXRF after sequential leaching”. Samek L, Ostachowicz B, Worobiec A, Spolnik Z, Van Grieken R, X-ray spectrometry 35, 226 (2006). http://doi.org/10.1002/XRS.905
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.905
|
|
|
“High-energy polarized-beam EDXRF for trace metal analysis of vegetation samples in environmental studies”. Marguí, E, Padilla R, Hidalgo M, Queralt I, Van Grieken R, X-ray spectrometry 35, 169 (2006). http://doi.org/10.1002/XRS.890
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.890
|
|
|
“EDXRF determination of impurities in potassium dihydrogenphosphate single crystals and raw materials”. Belikov KN, Mikhailova LI, Spolnik ZM, Van Grieken R, X-ray spectrometry 35, 112 (2006). http://doi.org/10.1002/XRS.874
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.874
|
|
|
“Ruthenium staining as an alternative preparation method for automated EPMA of individual biogenic and organic particles”. Worobiec A, Kaplinski A, Van Grieken R, X-ray spectrometry 34, 245 (2005). http://doi.org/10.1002/XRS.807
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.807
|
|
|
“Grazing-exit electron probe x-ray microanalysis of light elements in particles”. Spolnik Z, Tsuji K, Van Grieken R, X-ray spectrometry 33, 16 (2004). http://doi.org/10.1002/XRS.656
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.656
|
|
|
“Literature trends in x-ray emission spectrometry in the period 1990-2000: a review”. Injuk J, Van Grieken R, X-ray spectrometry 32, 35 (2003). http://doi.org/10.1002/XRS.606
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.606
|
|
|
“Performance of a new compact EDXRF spectrometer for aerosol analysis”. Samek L, Injuk J, van Espen P, Van Grieken R, X-ray spectrometry 31, 84 (2002). http://doi.org/10.1002/XRS.551
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.551
|
|
|
“Evaluation of energy-dispersive x-ray spectra of low-Z elements from electron-probe microanalysis of individual particles”. Osán J, de Hoog J, van Espen P, Szalóki I, Ro C-U, Van Grieken R, X-ray spectrometry 30, 419 (2001). http://doi.org/10.1002/XRS.523
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.523
|
|
|
“Individual particle characterization of Siberian aerosols by micro-PIXE and backscattering spectrometry”. van Malderen H, Hoornaert S, Injuk J, Przybylowicz WJ, Pineda CA, Prozesky VM, Van Grieken R, X-ray spectrometry 30, 320 (2001). http://doi.org/10.1002/XRS.505
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.505
|
|
|
“Optimization of experimental conditions of thin-window EPMA for ligh-element analysis of individual environmental particles”. Szalóki I, Osán J, Worobiec A, de Hoog J, Van Grieken R, X-ray spectrometry 30, 143 (2001). http://doi.org/10.1002/XRS.473.ABS
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.473.ABS
|
|
|
“Efficiency calibartion of energy-dispersive detectors for application in quantitative x- and γ-ray spectrometry”. Szalóki I, Szegedi S, Varga K, Braun M, Osán J, Van Grieken R, X-ray spectrometry 30, 49 (2001). http://doi.org/10.1002/XRS.467
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.467
|
|
|
“X-ray spectrometry applied for characterization of bricks of Brazilian historical sites”. Asfora VK, Bueno CC, de Barros VM, Khoury H, Van Grieken R, X-Ray Spectrometry , 1 (2020). http://doi.org/10.1002/XRS.3194
Abstract: This paper presents the results of X-ray fluorescence (XRF) analysis of bricks sampled from historical places in Pernambuco, a state in the northeastern region of Brazil. In this study, twenty bricks found in historical sites were analyzed. Two bricks made in the 17th century, presumably used as ballast in ships coming from Holland, five locally manufactured bricks: one from 18th century, three from 19th century, and one from 20th century, and thirteen bricks collected from a recent Archeological investigation of Alto da Se, in the town of Olinda. Qualitative determination of the chemical elements present in the samples was undertaken using a self-assembled portable XRF system based on a compact X-ray tube and a thermoelectrically cooled Si-PIN photodiode system, both commercially available. X-ray diffraction analysis was also carried out to assess the crystalline mineral phases present in the bricks. The results showed that quartz (SiO2) is the major mineral content in all bricks. Although less expressive in the XRD patterns, mineral phases of illite, kaolinite, anorthite, and rutile are also identified. The trace element distribution patterns of the bricks, determined by the XRF technique, is dominated by Fe and, in decreasing order, by K, Ti, Ca, Mn, Zr, Rb, Sr, Cr, and Y with slight differences among them. Analyses of the chemical compositional features of the bricks, evaluated by principal component analysis of the XRF datasets, allowed the samples to be grouped into five clusters with similar chemical composition. These cluster groups were able to identify both age and manufacturing sites. Dutch bricks prepared with different geological clays compositions were defined.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.2
DOI: 10.1002/XRS.3194
|
|
|
“Investigation of heavy metal distributions along 15m soil profiles using EDXRF, XRD, SEM-EDX, and ICP-MS techniques”. Ozen SA, Ozkalayci F, Cevik U, Van Grieken R, X-ray spectrometry 47, 231 (2018). http://doi.org/10.1002/XRS.2832
Abstract: The research of soil contamination by heavy metal is an important field due to its environmental and health implications. The goal was to study the elemental mobility as a function of depth. For this reason, the distribution of heavy metals (V, Cr, Co, Ni, Cu, Zn, As, Sn, and Pb) was investigated along soil profiles up to a depth of 15m at 9 sampling sites in the Nilufer industrial district (Bursa, Turkey). Elemental analyses were done with the Epsilon 5 energy dispersive X-ray fluorescence and inductively coupled plasma mass spectrometry equipment. Particle analysis was performed with a JEOL scanning electron microscope equipped with a Si(Li) X-ray detector. The crystallographic compositions of oxide compounds in soil samples were identified by a Rigaku X-ray diffraction instrument. Different parameters such as the soil's chemical (mineralogical structure, pH, and electrical conductivity) and physical properties (the number of blows, the stiffness index, the liquidity index, the plasticity index, and the water content) were analyzed. To assess the mobility of the heavy metals, diffusion (D) and convection coefficients (?) were calculated with the finite difference method. Convection was determined to dominate the studied region. In addition, the mobility coefficient was determined for each metal. High mobilities were determined for Zn and V, moderate mobilities for Cr, Ni, Cu, and As, and low mobilities were determined for Co and Pb. The results revealed that elements had reached depths of up to 15m, causing irreversible soil contamination that may lead to environmental health issues.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2832
|
|
|
“New insights in technology characterization of medieval Valencia glazes”. Romero-Pastor J, Garcia-Porras A, Van Grieken R, Potgieter-Vermaak S, Coll-Conesa J, Cardell C, X-ray spectrometry 44, 426 (2015). http://doi.org/10.1002/XRS.2613
Abstract: This study shows the first Raman microscopy (RM) and scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX) characterization of two 14th and 15th century lead-glazed and luster ceramics from the Manises and Paterna workshops (Valencia, Spain) produced after the Aragon Christian conquest of the Iberian Peninsula (14th century). According to experts, these coetaneous ceramics were most probably involved in a process of technological transfer from the Islamic area of Southeast Spain to the Christian area of Valencia (East Spain) at the beginning of the 14th century; later on, the celebrated Manises and Paterna workshops were formed. Although these ceramics have been studied widely in terms of production technology (ceramic body, glazes and luster) using an array of diverse analytical techniques, until now, an RM study has not been carried out. This paper presents results regarding the complex chemical composition of the glaze and luster coloring agents, and the quality of color manufacturing processes, elucidating firing conditions via spectral components analysis (i.e., Q(n) for stretching/bending components) and polymerization index (Ip), emphasizing chronology and pigment technology changes between both Valencian workshops. Coloring agents identified in glazes and lusters were cobalt present in blue glazes, copper in greenish glazes, copper and cobalt in the turquoise glaze, and pyrolusite in black glazes. Tin oxyde was used as an opacifier in white glazes. Two luster manufacture recipes were recognized mainly based on copper and silver compounds. Calculated firing temperatures were up to 1000 degrees C for white glazes and up to 600 degrees C for luster and color glazes. Copyright (c) 2015 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2613
|
|
|
“Introducing four new members of the editorial board of X-ray spectrometry”. Van Grieken R, X-ray spectrometry 44, 1 (2015). http://doi.org/10.1002/XRS.2577
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2577
|
|
|
“2014 Award for best referee of X-Ray Spectrometry”. Van Grieken R, X-ray spectrometry 43, 311 (2014). http://doi.org/10.1002/XRS.2564
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2564
|
|
|
“Optimized energy dispersive X-ray fluorescence analysis of atmospheric aerosols collected at pristine and perturbed Amazon Basin sites”. Arana A, Loureiro AL, Barbosa HMJ, Van Grieken R, Artaxo P, X-ray spectrometry 43, 228 (2014). http://doi.org/10.1002/XRS.2544
Abstract: Elemental composition of aerosols is important to source apportionment studies and to understand atmospheric processes that influence aerosol composition. Energy dispersive X-ray fluorescence spectroscopy was applied for measuring the elemental composition of Amazonian atmospheric aerosols. The instrument used was a spectrometer Epsilon 5, PANalytical B. V., with tridimensional geometry that reduces the background signal with a polarized X-ray detection. The measurement conditions were optimized for low-Z elements, e. g. Mg, Al, Si, that are present at very low concentrations in the Amazon. From Na to K, our detection limits are about 50% to 75% lower than previously published results for similar instrument. Calibration was performed using Micromatter standards, except for P whose standard was produced by nebulization of an aqueous solution of KH2PO4 at our laboratory. The multi-element reference material National Institute of Standards and Technology-2783 (air particulate filter) was used for evaluating the accuracy of the calibration procedure of the 22 elements in our standard analysis routine, and the uncertainty associated with calibration procedures was evaluated. The overall performance of the instrument and validation of our measurements were assessed by comparison with results obtained from parallel analysis using particle-induced X-ray emission and another Epsilon 5 spectrometer. The elemental composition in 660 samples collected at a pristine site in the Amazon Basin and of 1416 samples collected at a site perturbed by land use change was determined. Our measurements show trace elements associated with biogenic aerosols, soil dust, biomass burning, and sea-salt, even for the very low concentrations as observed in Amazonia. Copyright (C) 2014 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2544
|
|