“Geochemistry of suspended matter from the baltic sea : 1 : results of individual particle characterization by automated electron microprobe”. Bernard PC, Van Grieken RE, Brügmann L, Marine chemistry 26, 155 (1989). http://doi.org/10.1016/0304-4203(89)90058-3
Abstract: Automated electron probe X-ray microanalysis was used to characterize some 15 000 individual suspension particles from 50 samples of suspended matter collected from different depths at 18 stations throughout the Baltic Sea and the transient area to the North Sea. For each particle, 14 minor and major elements were determined and size information data were obtained. To process this huge amount of results, multivariate analysis techniques were invoked: the particles were classified into specific types and the abundance variations of these groups were studied. It appeared that 80% of all investigated particles contained mostly silicon, and seemed to consist of quartz, and K-rich and Fe-rich aluminosilicates. The abundance of BaSO4 particles averaged 5% throughout the Baltic Sea, but amounted to up to 44% at some stations. The abundance of the Fe-rich particles varied significantly with location and depth, and averaged ∼ 4%. They were often found to be associated with significant amounts of P. Both of these particle types and the Mn-rich particles are thought to be mainly authigenic. Calcium carbonate particles are more abundant towards the North Sea (which seems to act as a source). Principal component analysis of the data revealed that most of the compositional variability can be explained by differences between deep and surface waters and by the influences of inflowing North Sea waters. Additional information about the types and sources of the suspended matter in the Baltic Sea was gained from the comparison and correlation of the single particle results with different fractions of the bulk concentrations of elements such as Al, Ca, Mn, Fe, Zn and Ba.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(89)90058-3
|
“Kinetics of iron(II) oxidation in seawater of various pH : reply”. Roekens EJ, Van Grieken RE, Marine chemistry 15, 281 (1984). http://doi.org/10.1016/0304-4203(84)90025-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(84)90025-2
|
“Kinetics of iron(II) oxidation in seawater of various pH”. Roekens EJ, Van Grieken RE, Marine chemistry 13, 195 (1983). http://doi.org/10.1016/0304-4203(83)90014-2
Abstract: The rate of iron(II) oxidation in North Sea water of pH 5.510 in the range 1025°C has been studied. The oxygenation rate depends linearly on the iron(II) and dissolved oxygen concentrations. The second-order dependence on [OH−], found by several investigators for synthetic solutions, was confirmed in seawater, but only for pOH > 6.9. For pOH < 5.9 the rate appeared to be independent of the pOH. In the intermediate range, pOH 5.96.9, corresponding to the natural pH of seawater, a first-order dependence on the pOH is obeyed. The important discrepancy in the literature between the second-order rate constant for NaCHO3 solutions and for seawater can be attributed predominantly to the incorrect assumption of a second-order pOH dependence in natural seawater. The results can be useful, for example, in predicting the effect of dumping acidic iron waste from the titanium-dioxide industry into the ocean.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(83)90014-2
|
“On the interpretation of HREM images of partially ordered alloys”. De Meulenaere P, Van Tendeloo G, van Landuyt J, van Dyck D, Ultramicroscopy 60, 265 (1995). http://doi.org/10.1016/0304-3991(95)00065-9
Abstract: The ordering for 11/20 alloys has been studied by high-resolution electron microscopy (HREM). The distribution of the intensity maxima in the HREM image have been statistically examined, which provides a profound basis for the image interpretation. Processing of the HREM images allows ''dark-field'' images to be obtained, exhibiting a two-dimensional distribution of those columns which contain the most information in order to interpret the short-range order correlations. Pair correlations and higher cluster correlations between projected columns can be visualised, providing unique information about the ordering as retrieved from an experimental result without any other assumption. The method has been applied to Au4Cr and to Au4Mn to interpret the quenched short-range order state and the transition to long-range order.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 20
DOI: 10.1016/0304-3991(95)00065-9
|
“Dynamical electron diffraction in substitutionally disordered column structures”. De Meulenaere P, van Dyck D, Van Tendeloo G, van Landuyt J, Ultramicroscopy 60, 171 (1995). http://doi.org/10.1016/0304-3991(95)00040-8
Abstract: For column structures, such as fee-based alloys viewed along the cube direction, the concept of electron channelling through the atom columns is more and more used to interpret the corresponding HREM images. In the case of(partially) disordered columns, the projected potential approach which is used in the channelling description must be questioned since the arrangement of the atoms along the beam direction might affect the exit wave of the electrons. In this paper, we critically inspect this top-bottom effect using multi-slice calculations. A modified channelling theory is introduced which turns out to be very appropriate for the interpretation of these results. For substitutionally disordered column structures, it is also discussed how to link the chemical composition of the material to statistical data of the HREM image. This results in a convenient tool to discern images taken at different thicknesses and focus values.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 14
DOI: 10.1016/0304-3991(95)00040-8
|
“The reciprocal space of carbon tubes: a detailed interpretation of the electron diffraction effects”. Zhang XB, Zhang XF, Amelinckx S, Van Tendeloo G, van Landuyt J, Ultramicroscopy 54, 237 (1994). http://doi.org/10.1016/0304-3991(94)90123-6
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 59
DOI: 10.1016/0304-3991(94)90123-6
|
“A simple preparation method for air-sensitive specimens for transmission electron microscopy demonstrated by Rb6C60”. Zhang XF, Zhang XB, Bernaerts D, Van Tendeloo G, Amelinckx S, van Landuyt J, Werner H, Ultramicroscopy 55, 25 (1994). http://doi.org/10.1016/0304-3991(94)90077-9
Abstract: In this paper a particularly simple but efficient method is presented by which samples of alkali-doped C-60 materials or other air-sensitive materials can be prepared and transferred into a transmission electron microscope for direct observations and investigations. Flexible, transparent glove bags are used which are filled to a slight overpressure with dry nitrogen. Under this protective atmosphere, the air-sensitive sample is mounted in the specimen holder and inserted in the vacuum of the electron microscope. Rb6C60 which is prepared and transferred into the microscope in this way has been investigated by transmission electron microscopy (TEM). The results confirm the bcc structure and especially the location of the rubidium atoms.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 2
DOI: 10.1016/0304-3991(94)90077-9
|
“Electron diffraction effects of conical, helically wound, graphite whiskers”. Luyten W, Krekels T, Amelinckx S, Van Tendeloo G, van Dyck D, van Landuyt J, Ultramicroscopy 49, 123 (1993). http://doi.org/10.1016/0304-3991(93)90219-N
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 14
DOI: 10.1016/0304-3991(93)90219-N
|
“Structures and phase transitions in C60 and C70 fullerites”. Van Tendeloo G, Amelinckx S, Muto S, Verheijen MA, van Loosdrecht PHM, Meijer G, Ultramicroscopy 51, 168 (1993). http://doi.org/10.1016/0304-3991(93)90145-N
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 17
DOI: 10.1016/0304-3991(93)90145-N
|
“Selective imaging of sublattices in complex structures”. Amelinckx S, Milat O, Van Tendeloo G, Ultramicroscopy 51, 90 (1993). http://doi.org/10.1016/0304-3991(93)90138-N
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 8
DOI: 10.1016/0304-3991(93)90138-N
|
“Selective imaging of the “substructures&rdquo, in incommensurately modulated intergrowth crystal structures”. Milat O, Van Tendeloo G, Amelinckx S, Ultramicroscopy 41, 65 (1992). http://doi.org/10.1016/0304-3991(92)90095-2
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 5
DOI: 10.1016/0304-3991(92)90095-2
|
“Inelastic scattering of high-energy electrons in a crystal in thermal equilibrium with the environment: 1: theoretical framework”. Fanidis C, van Dyck D, van Landuyt J, Ultramicroscopy 41, 55 (1992). http://doi.org/10.1016/0304-3991(92)90094-Z
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 17
DOI: 10.1016/0304-3991(92)90094-Z
|
“In situ HREM study of electron irradiation effects in AgCl microcrystals”. Goessens C, Schryvers D, van Landuyt J, de Keyzer R, Ultramicroscopy 40, 151 (1992). http://doi.org/10.1016/0304-3991(92)90056-P
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 10
DOI: 10.1016/0304-3991(92)90056-P
|
“The evolution of HVEM application in antwerp”. van Landuyt J, Ultramicroscopy
T2 –, 2nd Osaka International Symp.on High-Voltage Electron Microscopy : New Directions and Future Aspects of High Voltage Electron Microscopy, November 8-10, 1990, Osaka University, Osaka, Japan 39, 287 (1991). http://doi.org/10.1016/0304-3991(91)90208-N
Abstract: The evolution of the use of the 1250 keV high-voltage electron microscope in Antwerp is sketched by illustrating a non-exhaustive set of examples in various fields. One of the main present fields of application gets some more attention, i.e. the defect studies as produced by processing steps in microelectronic devices: (i) strain-induced dislocations at the edges of various device isolation interlayers, (ii) morphologies resulting from high-energy ion implantation creating buried layers for silicon on insulator (SOI) and other implantation technologies.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
DOI: 10.1016/0304-3991(91)90208-N
|
“On the relative stabilities of the linear and triangular forms of B3N”. Slanina Z, Martin JML, François JP, Gijbels R, Chemical physics 178, 77 (1993). http://doi.org/10.1016/0301-0104(93)85052-A
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.652
Times cited: 9
DOI: 10.1016/0301-0104(93)85052-A
|
“The structure of different phases of pure C70 crystals”. Verheijen MA, Meekes H, Meijer G, Bennema P, de Boer JL, van Smaalen S, Van Tendeloo G, Amelinckx S, Muto S, van Landuyt J, Chemical physics 166, 287 (1992). http://doi.org/10.1016/0301-0104(92)87026-6
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.652
Times cited: 168
DOI: 10.1016/0301-0104(92)87026-6
|
“Sulphite and sulphate concentrations in weathering products of sandy limestone and in deposition samples”. Roekens E, Bleyen C, Van Grieken R, Environmental pollution 57, 289 (1989). http://doi.org/10.1016/0269-7491(89)90084-5
Abstract: The sulphite and sulphate concentrations in weathering products of limestone and in wet and total deposition samples were measured by the modified West-Gaeke method and by ion chromatography. The sulphite content in the weathering crust and in the runoff rainwater of two historical buildings in Belgium, was always much lower than the sulphate content. The maximum sulphite to sulphate ratio was 2·5%. The sulphite concentration in wet and total deposition samples was in the low or sub ppm range except during two misty periods when the sulphite concentration was 6·8 and 21 mg litre−1. In those samples a high sulphate concentration was also found (nl. 57 and 137 mg litre−1, respectively).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0269-7491(89)90084-5
|
“The development process of an expert system for the automated interpretation of large epma data sets”. Janssens K, Dorrine W, van Espen P, Chemometrics and intelligent laboratory systems 4, 147 (1988). http://doi.org/10.1016/0169-7439(88)80086-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80086-8
|
“PC-MCA : a software package for the acquisition and processing of spectral data”. Janssens K, Nobels J, van Espen P, Chemometrics and intelligent laboratory systems 3, 335 (1988). http://doi.org/10.1016/0169-7439(88)80033-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80033-9
|
“AXIL-PC, software for the analysis of complex-x-ray spectra”. van Espen P, Janssens K, Nobels J, Chemometrics and intelligent laboratory systems 1, 109 (1986). http://doi.org/10.1016/0169-7439(86)80031-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(86)80031-4
|
“Photoelectric and electrical responses of several erbium silicide/silicon interfaces”. Muret P, Nguyen TTA, Frangis N, Van Tendeloo G, van Landuyt J, Applied surface science
T2 –, International Symposium on Si Heterostructures –, From Physics to Devices, SEP 11-14, 1995, IRAKLION, GREECE 102, 173 (1996). http://doi.org/10.1016/0169-4332(96)00042-6
Abstract: In this work, photoelectric yield and electrical properties of several types of epitaxial erbium silicide on silicon Schottky diodes are studied, Different preparation conditions are used simultaneously on n- and p-Si(111) substrates for the 200 Angstrom thick silicide films. A last type of sample consists in 1.3 monolayer of epitaxial silicide with root 3 X root 3 superstructure on the Si substrate and covered by silver on the top. Photocurrent measurements are done as a function of photon energy at several temperatures. All these samples show barrier heights near 1 eV on p-type Si, even for the interface comprising only 1.3 monolayer of silicide whereas barrier heights on n-rype Si span the range from 0.28 to 0.67 eV for this last kind of sample, the sum of the barriers always exceeding the silicon band gap, These photoelectric results are confirmed by electrical characterisations, All these results show that the Fermi level is pinned 0.1 eV below the conduction band edge on p-type Si but shifts to various positions lower within the band gap on n-type Si. This fact leads to the hypothesis of a density of -7 interface states close to the charge change in the Si depletion zone from p- to n-type, namely 10(12) eV(-1) cm(-2). Although some inhomogeneities and defects at the interface are detected by electron microscopy for samples annealed at 750 degrees C, Fermi level position seems rather insensitive to the structural details of the interface while the silicide thickness plays a role on n-type Si.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.711
Times cited: 3
DOI: 10.1016/0169-4332(96)00042-6
|
“Electron microscopy characterisation of erbium silicide-thin films grown on a Si(111) substrate”. Frangis N, Van Tendeloo G, van Landuyt J, Muret P, Nguyen TTA, Applied surface science 102, 163 (1996). http://doi.org/10.1016/0169-4332(96)00040-2
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.711
Times cited: 9
DOI: 10.1016/0169-4332(96)00040-2
|
“High crystalline quality erbium silicide films on (100) silicon grown in high vacuum”. Kaltsas G, Travlos A, Nassiopoulos AG, Frangis N, van Landuyt J, Applied surface science 102, 151 (1996). http://doi.org/10.1016/0169-4332(96)00036-0
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.711
Times cited: 14
DOI: 10.1016/0169-4332(96)00036-0
|
“Round-robin investigation of silicon-oxide on silicon reference materials for ellipsometry”. Vanhellemont J, Maes HE, Schaekers M, Armigliato A, Cerva H, Cullis A, de Sande J, Dinges H, Hallais J, Nayar V, Pickering C, Stehlé, JL, Van Landuyt J, Walker C, Werner H, Salieri P;, Applied surface science
T2 –, SYMP ON DIAGNOSTIC TECHNIQUES FOR SEMICONDUCTOR MATERIALS ANALYSIS AND, FABRICATION PROCESS CONTROL, AT THE 1992 SPRING CONF OF THE EUROPEAN, MATERIALS RESEARCH SOC, JUN 02-05, 1992, STRASBOURG, FRANCE 63, 45 (1993). http://doi.org/10.1016/0169-4332(93)90062-G
Abstract: The main results and conclusions are presented of a round robin study of silicon oxide on silicon reference samples for ellipsometry. The oxide films with nominal thicknesses of 10, 50 and 120 nm are grown by thermal oxidation. The oxide film thicknesses have been determined by single wavelength ellipsometry (SWE), by spectroscopic ellipsometry (SE) and by cross-sectional conventional and high-resolution transmission electron microscopy (TEM and HREM) in different laboratories. The main conclusions are that special precautions have to be taken in order to use TEM as a reliable thickness measurement technique; that single wavelength ellipsometry can be used with great accuracy and reproducibility for the 50 and 120 nm film thicknesses but that it shows some inherent problems for the 10 nm films; and that spectroscopic ellipsometry showed for all film thicknesses an accuracy and reproducibility which is clearly superior to that of SWE.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.711
Times cited: 13
DOI: 10.1016/0169-4332(93)90062-G
|
“Prediction of the optical characteristics and analytical qualities of an X-ray fluorescence microprobe at the European Synchrotron Radiation Facility (Grenoble)”. van Langevelde F, Janssens KH, Adams FC, Vis RD, Nuclear instruments and methods in physics research : A: accelerators, spectrometers, detectors and associated equipment 317, 383 (1992). http://doi.org/10.1016/0168-9002(92)90632-E
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0168-9002(92)90632-E
|
“Observation of vacancy clustering in FZ-Si crystals during in situ electron irradiation in a high voltage electron microscope”. Fedina L, van Landuyt J, Vanhellemont J, Aseev AL, Nuclear instruments and methods in physics research B112, 133 (1996). http://doi.org/10.1016/0168-583X(95)01277-X
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.124
Times cited: 4
DOI: 10.1016/0168-583X(95)01277-X
|
“Ion beam synthesis of \beta-SiC at 950 degrees C and structural characterization”. Frangis N, Nejim A, Hemment PLF, Stoemenos J, van Landuyt J, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms
T2 –, Symposium J on Correlated Effects in Atomic and Cluster Ion Bombardment and Implantation/Symposium C on Pushing the Limits of Ion Beam, Processing –, Fr 112, 325 (1996). http://doi.org/10.1016/0168-583X(95)01236-2
Abstract: The structure of beta-SiC formed by carbon implantation into Si at high temperatures (850-950 degrees C) at doses ranging between 0.2 X 10(18) to 1 X 10(18) cm(-2) at 200 keV, was studied by combined cross section and high resolution transmission electron microscopy (XTEM and HRTEM). Implantation was performed on (001) and (111) Si wafers. In both cases a buried beta-SiC layer was formed having the same orientation as the Si matrix.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 1.124
Times cited: 9
DOI: 10.1016/0168-583X(95)01236-2
|
“Accurate evaluation of \mu-PIXE and \mu-XRF spectral data through iterative least squares fitting”. Janssens K, Vekemans B, Adams F, van Espen P, Mutsaers P, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms
T2 –, 7th International Conference on Particle Induced X-ray Emission and Its Analytical Applications, MAY 26-30, 1995, Abano Terme, Italy 109, 179 (1996). http://doi.org/10.1016/0168-583X(95)01211-7
Abstract: The integration of the nonlinear least squares X-ray spectrum evaluation progam AXIL. into a mu-PIXE and a mu-XRF setup is discussed. The use of the software when procesing data sets derived from biological and geological samples is described.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0168-583X(95)01211-7
|
“Recombination reactions and geometry effects in laser microprobe mass analysis studied with 12C/13C bilayers”. Bruynseels F, Van Grieken R, International journal of mass spectrometry and ion processes 74, 161 (1986). http://doi.org/10.1016/0168-1176(86)85003-0
Abstract: Bilayers of carbon, consisting of a layer of natural carbon and a second layer highly enriched in 13C, were investigated with the LAMMA 500-® instrument. When such a bilayer is perforated by the laser beam, comparable amounts of 12C and 13C are evaporated and partly ionized so that geometry effects and recombination reactions during laser-induced ionization can straightforwardly be studied.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0168-1176(86)85003-0
|
“Influence of spark generator parameters in the analysis of graphite-electrodes by spark source-mass spectrometry”. Vos L, Van Grieken R, International journal of mass spectrometry and ion processes 55, 233 (1984). http://doi.org/10.1016/0168-1176(84)87087-1
Abstract: Spark source mass spectrometric analyses of doped carbon samples were performed at different pulse lengths, pulse frequencies and breakdown voltages. The pulse length and pulse frequencies had no influence on the analysis. The relation between breakdown voltage, spark gap and sample matrix was determined. With increasing breakdown voltage, the abundance of the multiply charged ions was found to decrease, whereas the abundance of the cluster ions increased. The breakdown voltage was also found to affect the absolute and relative intensities of different elements in different manners. Interpretation of these results led to some new considerations on the phenomena in a spark discharge.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0168-1176(84)87087-1
|