|
“Radio-isotope neutron activation analysis for vanadium, manganese and tungsten in alloy steels”. Lins Galdino SM, Costa Dantas C, Van Grieken R, Analytica chimica acta 196, 337 (1987). http://doi.org/10.1016/S0003-2670(00)83107-4
Abstract: An instrumental neutron activation method for V, Mn and W in alloy steels with a 241 Am/Be isotopic neutron source is described. The samples were irradiated to induce the nuclear reactions 51V(n, γ) 52V, 55Mn(n, γ)56Mn, and 186W(n, γ)187W. The activities were measured with a NaI(TI) detector. Interferences on the measured photopeaks were shown to be negligible by measuring the half-lives of 62V, 56Mn and 187W.These thre elementes were determined in the range 1.512.9% in special steels; manganese in the range 0.51.6% was measured in cast irons. Calibration was done by comparison with results from wet chemistry and x-ray fluorescence spectrometry. The processing times for the vanadium, manganese and tungsten determinations were 11 min, 3 h and 26.3 h, respectively, but these were reduced greatly by intoruding a scheme wherein six samples were simultaneously irradiated and the 56Mn and 187W nuclides were measured sequentially for a series of 66 samples. The average processing time was reduced to 45 min for tungsten with a precision of 4.0% and accuracy of 3.4% and 22.8 min for manganese with a precision of 3.8% and accuracy of 3.1%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)83107-4
|
|
|
“Determination of precious metals in ores and rocks by thermal neutron activation/\gamma-spectrometry after preconcentration by nickel sulphide fire assay and coprecipitation with tellurium”. Shazali I, Van 't dack L, Gijbels R, Analytica chimica acta 196, 49 (1987). http://doi.org/10.1016/S0003-2670(00)83069-X
Abstract: The six platinum group elements (Ru, Rh, Pd, Os, Ir and Pt) can be determined in geological samples down to the μg kg−1 level, by using nickel sulphide fire assay and neutron activation of the residue ramaining after dissolution of the nickel sulphide button in concentrated hydrochloric acid. Losses for the platinum group elements during this dissolution step are usually insignificant, except when the elements are present at ultra-trace levels. The can be recovered from the filtrate by coprecipitation with tellerium. The latter approach also permits determination of silver, which is significantly lost in the hydrochloric acid treatment (recovery <98% instead of typically ≈ 10%). The coprecipitation with tellurium considerably improves the results for gold (recovery ≈ 95% instead of typically 75%).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 49
DOI: 10.1016/S0003-2670(00)83069-X
|
|
|
“How perfluoroalkyl substances modify fluorinated self-assembled monolayer architectures : an electrochemical and computational study”. Moro G, Foumthuim CJD, Spinaci M, Martini E, Cimino D, Balliana E, Lieberzeit P, Romano F, Giacometti A, Campos R, De Wael K, Moretto LM, Analytica chimica acta 1204, 339740 (2022). http://doi.org/10.1016/J.ACA.2022.339740
Abstract: There is an urgent need for sensing strategies to screen perfluoroalkyl substances (PFAS) in aqueous matrices. These strategies must be applicable in large-scale monitoring plans to face the ubiquitous use of PFAS, their wide global spread, and their fast evolution towards short-chain, branched molecules. To this aim, the changes in fluorinated self-assembled monolayers (SAM) with different architectures (pinholes/defects-free and with randomized pinholes/defects) were studied upon exposure to both long and short-chain PFAS. The applicability of fluorinated SAM in PFAS sensing was evaluated. Changes in the SAM structures were characterised combining electrochemical impedance spectroscopy and voltam-metric techniques. The experimental data interpretation was supported by molecular dynamics simu-lations to gain a more in-depth understanding of the interaction mechanisms involved. Pinhole/defect-free fluorinated SAM were found to be applicable to long-chain PFAS screening within switch-on sensing strategy, while a switch-off sensing strategy was reported for screening of both short/long-chain PFAS. These strategies confirmed the possibility to play on fluorophilic interactions when designing PFAS screening methods.(c) 2022 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.ACA.2022.339740
|
|
|
“Controlling the mixed potential of polyelectrolyte-coated platinum electrodes for the potentiometric detection of hydrogen peroxide”. Baez JF, Compton M, Chahrati S, Cánovas R, Blondeau P, Andrade FJ, Analytica Chimica Acta 1097, 204 (2020). http://doi.org/10.1016/J.ACA.2019.11.018
Abstract: The use of a Pt electrode coated with a layer of Nafion has been described in previous works as an attractive way to perform the potentiometric detection of hydrogen peroxide. Despite of the attractive features of this approach, the nature of the non-Nernstian response of this system was not properly addressed. In this work, using a mixed potential model, the open circuit potential of the Pt electrode is shown to be under kinetic control of the oxygen reduction reaction (ORR). It is proposed that hydrogen peroxide acts as an oxygenated species that blocks free sites on the Pt surface, interfering with the ORR. Therefore, the effect of the polyelectrolyte coating can be understood in terms of the modulation of the factors that affects the kinetics of the ORR, such as an increase of the H+ concentration, minimization of the effect of the spectator species, etc. Because of the complexity and the lack of models that accurately describe systems with practical applications, this work is not intended to provide a mechanistic but rather a phenomenological view on problem. A general framework to understand the factors that affect the potentiometric response is provided. Experimental evidence showing that the use of polyelectrolyte coatings are a powerful way to control the mixed potential open new ways for the development of robust and simple potentiometric sensors.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.2
DOI: 10.1016/J.ACA.2019.11.018
|
|
|
“CAC-2010 : Twelfth international conference on chemometrics in analytical chemistry”. Buydens L, van Espen P, Rutan S, Analytica chimica acta 705, 1 (2011). http://doi.org/10.1016/J.ACA.2011.08.001
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ACA.2011.08.001
|
|
|
“Microanalytical characterization of surface decoration in Majolica pottery”. Padilla R, Schalm O, Janssens K, Arrazcaeta R, van Espen P, Analytica chimica acta 535, 201 (2005). http://doi.org/10.1016/J.ACA.2004.11.082
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 4.95
Times cited: 20
DOI: 10.1016/J.ACA.2004.11.082
|
|
|
“Elucidating the composition of atmospheric aerosols through the combined hierarchical, non-hierarchical and fuzzy clustering of large electron probe microanalysis data sets”. Treiger B, Bondarenko I, van Malderen H, Van Grieken R, Analytica chimica acta 317, 33 (1995). http://doi.org/10.1016/0003-2670(95)00405-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(95)00405-X
|
|
|
“Determination of gold at the ultratrace level in natural waters”. Cidu R, Fanfani L, Shaud P, Edmunds WM, Van 't dack L, Gijbels R, Analytica chimica acta 296, 295 (1994). http://doi.org/10.1016/0003-2670(94)80249-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 20
DOI: 10.1016/0003-2670(94)80249-1
|
|
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, van Grieken R, Gijbels R, Caravatti P, Analytica chimica acta 283, 139 (1993). http://doi.org/10.1016/0003-2670(93)85216-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 17
DOI: 10.1016/0003-2670(93)85216-7
|
|
|
“Synchrotron radiation-induced X-ray microanalysis”. Janssens K, Vincze L, Adams F, Jones KW, Analytica chimica acta 283, 98 (1993). http://doi.org/10.1016/0003-2670(93)85213-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(93)85213-4
|
|
|
“Surface microanalysis”. Adams F, Adriaens A, Berghmans P, Janssens K, Analytica chimica acta 283, 19 (1993). http://doi.org/10.1016/0003-2670(93)85207-Z
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(93)85207-Z
|
|
|
“Studying aerosol samples by non-linear mapping of electron probe microanalysis data”. Treiger B, van Malderen H, Bondarenko I, van Espen P, Van Grieken R, Analytica chimica acta 284, 119 (1993). http://doi.org/10.1016/0003-2670(93)80014-C
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0003-2670(93)80014-C
|
|
|
“Coprecipitation with aluminium hydroxide and x-ray fluorescence determination of trace metals in water”. Eltayeb MAH, Van Grieken RE, Analytica chimica acta 268, 177 (1992). http://doi.org/10.1016/0003-2670(92)85262-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(92)85262-5
|
|
|
“Comparison and evaluation of hierarchical cluster techniques applied to automated electron probe X-ray microanalysis data”. Bernard PC, Van Grieken RE, Analytica chimica acta 267, 81 (1992). http://doi.org/10.1016/0003-2670(92)85009-U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(92)85009-U
|
|
|
“Determination of trace selenium in biological material by preconcentration and X-ray emission spectrometry”. Robberecht H, Van Grieken R, Analytica chimica acta 147, 113 (1983). http://doi.org/10.1016/0003-2670(83)80077-4
Abstract: Selenium is determined in the ng g−1 to μg g−1 range in biological and environmental samples. A wet digestion procedure was optimized with respect to volatility losses and recovery yields, by using 75Se metabolically incorporated into rat organs. Selenium is preconcentrated from the digestion liquid by a two-step reduction with 4 M HCl and ascorbic acid. The colloidal selenium formed is adsorbed on activated carbon and filtered on a Nucleopore membrane for measurement by energy-dispersive x-ray fluorescence. Almost complete recovery was obtained, and the detection limit was 20 ng, corresponding to 10 ng g−1 for a 2-g sample. Biological reference materials were analyzed with satisfactory results, and the accuracy of the method was good.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(83)80077-4
|
|
|
“Application of chemometric methods for classification of atmospheric particles based on thin-window electron probe microanalysis data”. Osán J, de Hoog J, Worobiec A, Ro C-U, Oh K-Y, Szalóki I, Van Grieken R, Analytica chimica acta 446, 211 (2001)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of rare earth elements in geological materials by total reflection X-ray fluorescence”. Muia LM, Van Grieken R, Analytica chimica acta 251, 177 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|