|
“Compositional study of prehistoric pigments (Carriqueo rock shelter, Argentina) by synchrotron radiation X-ray diffraction”. Vazquez C, Martin Palacios O, Darchuk L, Marco Parra L-M, Powder diffraction 25, 264 (2010). http://doi.org/10.1154/1.3478884
Abstract: In this work synchrotron radiation X-ray diffraction technique was successfully applied for the analysis of pigments found in excavation at Carriqueo rock shelter, Neuquen, Argentina. The pigment samples of orange, red, and brown shades were collected from different levels of this archaeological site and compared with a suspected source of provenance (La Oficina creek). X-ray diffraction patterns of several yellowish, reddish, and red pigments showed the presence of haematite, goethite, kaolinite, and quartz. The majority of Carriqueo collected samples belonged to the same group of the suspected source, having haematite and quartz as main crystalline phases. The results indicate that the raw material from La Oficina is the source of most of the pigments found at Carriqueo. The present work helps us to understand the strategy of supplying raw materials by human groups in the North Patagonia region. (C) 2010 International Centre for Diffraction Data. [DOI: 10.1154/1.3478884]
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1154/1.3478884
|
|
|
“The use of synchrotron radiation for the characterization of artists' pigments and paintings”. Janssens K, Alfeld M, van der Snickt G, de Nolf W, Vanmeert F, Radepont M, Monico L, et al, Annual review of analytical chemistry 6, 399 (2013). http://doi.org/10.1146/ANNUREV-ANCHEM-062012-092702
Abstract: We review methods and recent studies in which macroscopic to (sub)microscopic X-ray beams were used for nondestructive analysis and characterization of pigments, paint microsamples, and/or entire paintings. We discuss the use of portable laboratory- and synchrotron-based instrumentation and describe several variants of X-ray fluorescence (XRF) analysis used for elemental analysis and imaging and combined with X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Macroscopic and microscopic (μ-)XRF variants of this method are suitable for visualizing the elemental distribution of key elements in paint multilayers. Technical innovations such as multielement, large-area XRF detectors have enabled such developments. The use of methods limited to elemental analysis or imaging usually is not sufficient to elucidate the chemical transformations that take place during natural pigment alteration processes. However, synchrotron-based combinations of μ-XRF, μ-XAS, and μ-XRD are suitable for such studies.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.435
Times cited: 46
DOI: 10.1146/ANNUREV-ANCHEM-062012-092702
|
|
|
“A decision support system for preventive conservation : from measurements towards decision making”. Schalm O, Cabal A, Anaf W, Leyva Pernia D, Callier J, Ortega N, The European Physical Journal Plus 134, 74 (2019). http://doi.org/10.1140/EPJP/I2019-12441-5
Abstract: We present a decision-support system that guides heritage guardians in selecting mitigation actions to improve the indoor air quality and thus the preservation conditions of indoor collections in heritage buildings. This contribution shows that it is feasible to build a decision support system dedicated to preventive conservation when the following barriers are overcome: 1) simultaneous measurement of a wide range of environmental parameters in order to detect a larger number of undesired situations; 2) development of an algorithm to perform reproducible indoor air quality assessments; and 3) transformation of the air quality assessment into a graph that can be read intuitively without causing a wide variation of interpretations among stakeholders. An important aspect of the decision support system is that it reduces several sources of uncertainty that hamper reliable indoor air quality assessments. The possibilities of such a system are illustrated with a measurement campaign in a church where a heating system has been installed and used for the first time.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Systems and software Modelling (AnSyMo); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1140/EPJP/I2019-12441-5
|
|
|
“Associations between ambient, personal, and indoor exposure to fine particulate matter constituents in Dutch and Finnish panels of cardiovascular patients”. Janssen NAH, Lanki T, Hoek G, Vallius M, de Hartog JJ, Van Grieken R, Pekkanen J, Brunekreef B, Occupational and environmental medicine 62, 868 (2005). http://doi.org/10.1136/OEM.2004.016618
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1136/OEM.2004.016618
|
|
|
van de Vijver FL, Verbueken AH, Visser WJ, Van Grieken RE, de Broe ME (1984) Localisation of aluminium and iron by histochemical and laster microprobe mass analytical techniques in bone marrow cells of chronic hemodialysis patients. 837–838
Keywords: L1 Letter to the editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1136/JCP.37.7.837-B
|
|
|
“Internal mixture of sea salt, silicates, and excess sulfate in marine aerosols”. Andreae MO, Charlson RJ, Bruynseels F, Storms H, Van Grieken R, Maenhaut W, Science 232, 1620 (1986). http://doi.org/10.1126/SCIENCE.232.4758.1620
Abstract: Individual aerosol particles from the remote marine atmosphere were investigated by scanning electron microscopy and electron microprobe analysis. A large fraction of the silicate mineral component of the aerosol was found to be internally mixed with sea-salt aerosol particles. This observation explains the unexpected similarity in the size distributions of silicates and sea salt that has been observed in remote marine aerosols. Reentrainment of dust particles previously deposited onto the sea surface and collision between aerosol particles can be excluded as possible source mechanisms for these internally mixed aerosols. The internal mixing could be produced by processes within clouds, including droplet coalescence. Cloud processes may also be responsible for the observed enrichment of excess (nonsea-salt) sulfate on sea-salt particles.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1126/SCIENCE.232.4758.1620
|
|
|
“Elemental compositions of comet 81P/Wild 2 samples collected by Stardust”. Flynn GJ, Janssens K, Vekemans B, [et al], Science 314, 1731 (2006). http://doi.org/10.1126/SCIENCE.1136141
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 37.205
Times cited: 174
DOI: 10.1126/SCIENCE.1136141
|
|
|
“Composition and state of alteration of 18th century glass from the Cistercian nunnery of Clairefontaine (Belgium)”. Herremans D, Cagno S, Vincke A, de Clercq W, Janssens K, Proceedings of the Society of Photo-optical Instrumentation Engineers
T2 –, Conference on Integrated Approaches to the Study of Historical Glass, (IASHG), APR 16-17, 2012, Brussels, BELGIUM , 842206 (2012). http://doi.org/10.1117/12.975247
Abstract: An extended set of 18th century glass vessels was analyzed by means of SEM-EDX (major and minor element composition) The fragmented archaeological objects were recovered from a latrine belonging to the early 18th century building phase of the nunnery of Clairefontaine, near Arlon (B). On the basis of typology and decoration, the major part of the vessels could be dated around the middle of the 18th century. Variety in color and weathering of the glass suggest differences in glassmaking recipes and in the composition and origin of raw materials. The results of the analysis show how two main compositional groups constitute about 90% of the analyzed glass set, and these are constituted by potash glass (transparent beakers) and high lime low alkali glass (green bottles). Next to these, a few potash-lime and soda glasses are also found. The type of alteration has also a clear relation with the original glass composition.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.975247
|
|
|
“Composition of Facon de Venise glass from early 17th century London in comparison with luxury glass of the same age”. Cagno S, de Raedt I, Jeffries T, Janssens K, Proceedings of the Society of Photo-optical Instrumentation Engineers
T2 –, Conference on Integrated Approaches to the Study of Historical Glass, (IASHG), APR 16-17, 2012, Brussels, BELGIUM , 842205 (2012). http://doi.org/10.1117/12.975212
Abstract: SEM-EDX and LA-ICP-MS analyses were performed on a set of early 17th century London glass fragments. The samples originate from two archaeological sites (Aldgate and Old Broad Street) where glass workshops were active in this period. The great majority of the samples are made of soda glass. Two distinct compositional groups are observed, each typical of one site of provenance. The samples originating from the Old Broad Street excavation feature a silica-soda-lime composition, with a moderate amount of potash. The samples from Aldgate are richer in potassium and feature higher amounts of trace elements such as Rb, Zr and Cu. The distinction between the two groups stems from different flux and silica sources used for glassmaking. A comparison with different European glass compositions of that time reveals no resemblance with genuine Venetian production, yet the composition of the Old Broad Street glass shows a close similarity to that of fragments produced 'a la facon de Venise' in Antwerp at the end of the 16th century. This coincides with historical sources attesting the arrival of glassworkers from the Low Countries in England and suggests that a transfer of technology took place near the turn of the century.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 1
DOI: 10.1117/12.975212
|
|
|
“The identification of chromophores in ancient glass by the use of UV-VIS-NIR spectroscopy”. Meulebroeck W, Baert K, Wouters H, Cosyns P, Ceglia A, Cagno S, Janssens K, Nys K, Terryn H, Thienpont H, Proceedings of the Society of Photo-optical Instrumentation Engineers 7726, 77260d (2010). http://doi.org/10.1117/12.853666
Abstract: In this publication optical spectroscopy is considered to be a supplementary technique to study ancient colored glass. It results from a systematic study of the UV-VIS-NIR transmission spectra of intentionally colored glass fragments from various archaeological and historical sites and dated from the Roman period to the 21th century AD. The main goal consists of defining optical sensing parameters for this type of material. The considered colorants are iron, cobalt, manganese, copper and chromium. It is proved that many cases exist where optical spectroscopy can be seen as a straightforward, non-destructive, low-cost and in-situ applicable technique in identifying authentic material or to obtain information about the origin of the material. Possible sensing parameters are defined as the absence/presence of absorption bands characteristic for a specific coloring metal oxide and the spectral position of these bands. These parameters could reveal information about the applied furnace conditions and/or to the composition of the glass matrix. It is shown that the cobalt absorption band situated around 535 nm for soda rich glasses (Roman and industrial times) is shifted towards 526 nm for potash rich glasses (medieval and post-medieval times).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 10
DOI: 10.1117/12.853666
|
|
|
“Simulation of poly-capillary lenses for coherent and partially coherent x-rays”. Vincze L, Kukhlevsky SV, Janssens K, Proceedings of the Society of Photo-optical Instrumentation Engineers
T2 –, Conference on Advances in Computational Methods for X-Ray and Neutron, Optics, AUG 03-05, 2004, Denver, CO , 81 (2004). http://doi.org/10.1117/12.560740
Abstract: The intensity distributions of the coherent and partially coherent x-rays passed through a poly-capillary lens have been computed at the focal plane. The computations showed that at the appropriate experimental conditions the interference phenomenon does affect the intensity distribution. In the case of the coherent input radiation with the photon energy of 0.1 keV, the interference fringes were observed, while the non-coherent x-ray radiation produced no interference-like intensity distributions.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 6
DOI: 10.1117/12.560740
|
|
|
“X-ray fluorescence microtomography and polycapillary based confocal imaging using synchrotron radiation”. Vincze L, Vekemans B, Szaloki I, Brenker FE, Falkenberg G, Rickers K, Aerts K, Van Grieken R, Adams F, , 220 (2004). http://doi.org/10.1117/12.560416
Abstract: Ibis work illustrates the development of X-ray fluorescence tomography and polycapillary based confocal imaging towards a three-dimensional (313), quantitative analytical method with lateral resolution levels down to the 2-20 mum scale. Detailed analytical characterization is given for polycapillary based confocal XRF imaging, which is a new variant of the 3D micro-XRF technique. Applications for 2D/3D micro-XR-F are illustrated for the analysis of biological (zooplankton) and geological samples (microscopic inclusions in natural diamonds and fluid inclusions in quartz). Based on confocal imaging, fully three-dimensional distributions of trace elements could be obtained, representing a significant generalization of the regular 2D scanning technique for micro-XRF spectroscopy. The experimental work described in this paper has been carried out at the ESRF ID18F microfluorescence end-station and at HASYLAB Beam Line L.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.560416
|
|
|
“High-resolution X-ray fluorescence micro-tomography on single sediment particles”. Vincze L, Vekemans B, Szalóki I, Janssens K, Van Grieken R, Feng H, Jones KW, Adams F page 240 (2002).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 11
DOI: 10.1117/12.452865
|
|
|
“Application of light beams with non-zero angular momentum in optical study of micrometer-size aerosol particles”. Bekshaev A, Kontush S, Popov A, Van Grieken R, , 288 (2001). http://doi.org/10.1117/12.428282
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.428282
|
|
|
“Monte Carlo simulation of X-ray fluorescence and scattering tomography experiments”. Vincze L, Janssens K, Vekemans B, Adams F page 328 (1999).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.363736
|
|
|
“Iron allocation in leaves of Fe-deficient cucumber plants fed with natural Fe complexes”. Zanin L, Tomasi N, Rizzardo C, Gottardi S, Terzano R, Alfeld M, Janssens K, De Nobili M, Mimmo T, Cesco S, Physiologia plantarum 154, 82 (2015). http://doi.org/10.1111/PPL.12296
Abstract: Iron (Fe) sources available for plants in the rhizospheric solution are mainly a mixture of complexes between Fe and organic ligands, including phytosiderophores (PS) and water-extractable humic substances (WEHS). In comparison with the other Fe sources, Fe-WEHS are more efficiently used by plants, and experimental evidences show that Fe translocation contributes to this better response. On the other hand, very little is known on the mechanisms involved in Fe allocation in leaves. In this work, physiological and molecular processes involved in Fe distribution in leaves of Fe-deficient Cucumis sativus supplied with Fe-PS or Fe-WEHS up to 5days were studied combining different techniques, such as radiochemical experiments, synchrotron micro X-ray fluorescence, real-time reverse transcription polymerase chain reaction and in situ hybridization. In Fe-WEHS-fed plants, Fe was rapidly (1day) allocated into the leaf veins, and after 5days, Fe was completely transferred into interveinal cells; moreover, the amount of accumulated Fe was much higher than with Fe-PS. This redistribution in Fe-WEHS plants was associated with an upregulation of genes encoding a ferric(III)-chelate reductase (FRO), a Fe2+ transporter (IRT1) and a natural resistance-associated macrophage protein (NRAMP). The localization of FRO and IRT1 transcripts next to the midveins, beside that of NRAMP in the interveinal area, may suggest a rapid and efficient response induced by the presence of Fe-WEHS in the extra-radical solution for the allocation in leaves of high amounts of Fe. In conclusion, Fe is more efficiently used when chelated to WEHS than PS and seems to involve Fe distribution and gene regulation of Fe acquisition mechanisms operating in leaves.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.33
Times cited: 14
DOI: 10.1111/PPL.12296
|
|
|
“The preparation and preliminary characterisation of eight geological MPI-DING reference glasses for in-site microanalysis”. Jochum KP, Dingwell DB, Rocholl A, Janssens K, Vincze L, et al, Geostandards newsletter 24, 87 (2000). http://doi.org/10.1111/J.1751-908X.2000.TB00590.X
Abstract: Eight silicate glasses were prepared by directly fusing and stirring 50-100 g each of basalt, andesite, komatiite, peridotite, rhyolite, and quartz-diorite. These are referred to as MPI-DING glasses and were made for the purpose of providing reference materials for geochemical, in-situ microanalytical work. Results from various analytical techniques indicate that individual glass fragments are well homogenised with respect to major and trace elements at the mu m to mm scale. Heterogeneities due to quench crystallisation of olivine have been observed in small and limited areas of the two komatiitic glasses. In order to obtain concentration values for as many elements as possible, the glasses were analysed by a variety of bulk and microanalytical methods in a number of laboratories. From the analytical data, preliminary reference values for more than sixty elements were calculated. The analytical uncertainties of most elements are estimated to be between 1% and 10%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1751-908X.2000.TB00590.X
|
|
|
“Laser microprobe mass analysis (LAMMA) to study lead intoxication at the subcellular level”. Vandeputte DF, Verbueken AH, Jacob WA, Van Grieken RE, Acta pharmacologica et toxicologica 59, 617 (1986). http://doi.org/10.1111/J.1600-0773.1986.TB02840.X
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0773.1986.TB02840.X
|
|
|
“Characterization of indoor air quality in primary schools in Antwerp, Belgium”. Stranger M, Potgieter-Vermaak SS, Van Grieken R, Indoor air: international journal of indoor quality and climate 18, 454 (2008). http://doi.org/10.1111/J.1600-0668.2008.00545.X
Abstract: The indoor air quality of 27 primary schools located in the city centre and suburbs of Antwerp, Belgium, was assessed. The primary aim was to obtain correlations between the various pollutant levels. Indoor:outdoor ratios and the building and classroom characteristics of each school were investigated. This paper presents results on indoor and local outdoor PM2.5 mass concentrations, its elemental composition in terms of K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Al, Si, S, and Cl, and its black smoke content. In addition, indoor and local outdoor levels of the gases NO2, SO2, O3, and BTEX (benzene, toluene, ethyl benzene, and xylene isomers) were determined. Black smoke, NO2, SO2 and O3, occurred at indoor:outdoor ratios below unity, indicating their significant outdoor sources. No linear correlation was established between indoor and outdoor levels for PM2.5 mass concentrations and BTEX; their indoor:outdoor ratios exceeded unity except for benzene. Classroom PM2.5 occurred with a different elemental composition than local outdoor PM2.5. The re-suspension of dust because of room occupation is probably the main contributor for the I/O ratios higher than 1 reported for elements typically constituting dust particles. Finally, increased benzene concentrations were reported for classrooms located at the lower levels.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0668.2008.00545.X
|
|
|
“The indoor environment of a modern museum building, the Sainsbury Centre for Visual Arts, Norwich, UK”. Brimblecombe P, Blades N, Camuffo D, Sturaro G, Valentino A, Gysels K, Van Grieken R, Busse H-J, Kim O, Ulrych U, Wieser M, Indoor air 9, 146 (1999). http://doi.org/10.1111/J.1600-0668.1999.T01-1-00002.X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0668.1999.T01-1-00002.X
|
|
|
“Manganese staining of archaeological glass : the characterization of Mn-rich inclusions in leached layers and a hypothesis of its formation”. Schalm O, Proost K, De Vis K, Cagno S, Janssens K, Mees F, Jacobs P, Caen J, Archaeometry 53, 103 (2011). http://doi.org/10.1111/J.1475-4754.2010.00534.X
Abstract: During the study of a large number of archaeological glass fragments, manganese-rich inclusions in leached layers were observed in a limited number of cases. This phenomenon occurs only in black-coloured leached layers. Since the formation mechanism of such manganese-rich inclusions is still unclear, a combination of several analytical techniques was used in order to investigate this phenomenon and, more specifically, to obtain more information on (a) the composition and morphology of the inclusions, (b) the chemical state of Mn and (c) the 3D morphology of the inclusions. A mechanism that might explain the formation of these inclusions is proposed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.47
Times cited: 24
DOI: 10.1111/J.1475-4754.2010.00534.X
|
|
|
“Deeply coloured and black glass in the Northern provinces of the Roman Empire : differences and similarities in chemical composition before and after AD 150”. van der Linden V, Cosyns P, Schalm O, Cagno S, Nys K, Janssens K, Nowak A, Wagner B, Bulska E, Archaeometry 51, 822 (2009). http://doi.org/10.1111/J.1475-4754.2008.00434.X
Abstract: In this work we attempt to elucidate the chronological and geographical origin of deeply coloured and black glass dating between 100 bc and ad 300 on the basis of their major and trace element compositions. Samples from the western and eastern parts of the Roman Empire were analysed. Analytical data were obtained by means of a scanning electron microscope – energy-dispersive system (SEM-EDS, 63 samples analysed) and laser ablation – inductively coupled plasma – mass spectrometry (LA-ICP-MS, 41 samples analysed). Among the glass fragments analysed, dark brown, dark purple and dark green hues could be distinguished. Only among the dark green fragments could a clear compositional distinction be observed between fragments dated to the periods before and after ad 150. In the early samples (first century bc to first century ad), iron, responsible for the green hue, was introduced by using impure sand containing relatively high amounts of Ti. In contrast, a Ti-poor source of iron was employed, containing Sb, Co and Pb in trace quantities, in order to obtain the dark green colour in the later glass samples. The analytical results obtained by combining SEM-EDS and LA-ICP-MS are therefore consistent with a differentiation of glassmaking recipes, detectable in glass composition, occurring in the period around ad 150.
Keywords: A1 Journal article; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.47
Times cited: 39
DOI: 10.1111/J.1475-4754.2008.00434.X
|
|
|
“Occupational allergic contact dermatitis from bisphenol A in vinyl gloves”. Matthieu L, Godoi AFL, Lambert J, Van Grieken R, Contact dermatitis 49, 281 (2003). http://doi.org/10.1111/J.0105-1873.2003.0241.X
Abstract: Allergic contact dermatitis caused by polyvinyl chloride gloves is rarely reported, and in only 2 cases was bisphenol A considered to be the responsible sensitizer. We report a patient with occupational hand dermatitis after the use of a new type of high-density vinyl (HDV) gloves. Patch tests showed positive (++) reactions to both used and new HDV gloves and to bisphenol A. Chemical analysis by gas chromatography-mass spectrometry demonstrated the presence of bisphenol A in the HDV gloves. Replacement by nitrile rubber gloves resulted in complete clearance of the hand dermatitis.
Keywords: A1 Journal article; Translational Pathophysiological Research (TPR); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.0105-1873.2003.0241.X
|
|
|
“A Roman Egyptian Painting Workshop : technical investigation of the portraits from Tebtunis, Egypt”. Salvant J, Williams J, Ganio M, Casadio F, Daher C, Sutherland K, Monico L, Vanmeert F, De Meyer S, Janssens K, Cartwright C, Walton M, Archaeometry 60, 815 (2018). http://doi.org/10.1111/ARCM.12351
Abstract: Roman-period mummy portraits are considered to be ancient antecedents of modern portraiture. However, the techniques and materials used in their manufacture are not thoroughly understood. Analytical study of the pigments as well as the binding materials helps to address questions on what aspects of the painting practices originate from Pharaonic and/or Graeco-Roman traditions, and can aid in determining the provenance of the raw materials from potential locations across the ancient Mediterranean and European worlds. Here, one of the largest assemblages of mummy portraits to remain intact since their excavation from the site of Tebtunis in Egypt was examined using multiple analytical techniques to address how they were made. The archaeological evidence suggests that these portraits were products of a single workshop and, correspondingly, they are found to be made using similar techniques and materials: wax-based and lead white-rich paint combined with a variety of iron-based pigments (including hematite, goethite and jarosite), as well as Egyptian blue, minium, indigo and madder lake to create subtle variations and tones.
Keywords: A1 Journal article; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.47
Times cited: 6
DOI: 10.1111/ARCM.12351
|
|
|
“Elemental analysis of aerosols using proton-scattering”. Nelson JW, Williams I, Johansson TB, Van Grieken RE, IEEE transactions on nuclear science Ns21, 618 (1974). http://doi.org/10.1109/TNS.1974.4327522
Abstract: Elemental analysis for all of the light elements up through chlorine by elastic scattering of 16 MeV protons has been shown to be feasible. Basic problems associated with such measurements are discussed including kinematics, angular distribution, and sample backings. Spectra are presented for air particulate matter for both a total filter (Nuclepore) and a size fractionated air impactor (polystyrene backed) sample. The method is absolute, non destructive and can be used in conjunction with proton induced x-ray fluorescence to quantitatively analyze all elements in the same sample in minutes of time.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1109/TNS.1974.4327522
|
|
|
“High-resolution X-ray fluorescence microtomography of homogeneous samples”. Simionovici AS, Chukalina M, Schroer C, Drakopoulos M, Snigirev A, Snigireva I, Lengeler B, Janssens K, Adams F, IEEE transactions on nuclear science 47, 2736 (2000). http://doi.org/10.1109/23.901180
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.171
DOI: 10.1109/23.901180
|
|
|
“XRDUA : crystalline phase distribution maps by two-dimensional scanning and tomographic (micro) X-ray powder diffraction”. de Nolf W, Vanmeert F, Janssens K, Journal of applied crystallography 47, 1107 (2014). http://doi.org/10.1107/S1600576714008218
Abstract: Imaging of crystalline phase distributions in heterogeneous materials, either plane projected or in virtual cross sections of the object under investigation, can be achieved by scanning X-ray powder diffraction employing X-ray micro beams and X-ray-sensitive area detectors. Software exists to convert the two-dimensional powder diffraction patterns that are recorded by these detectors to one-dimensional diffractograms, which may be analysed by the broad variety of powder diffraction software developed by the crystallography community. However, employing these tools for the construction of crystalline phase distribution maps proves to be very difficult, especially when employing micro-focused X-ray beams, as most diffraction software tools have mainly been developed having structure solution in mind and are not suitable for phase imaging purposes. XRDUA has been developed to facilitate the execution of the complete sequence of data reduction and interpretation steps required to convert large sequences of powder diffraction patterns into a limited set of crystalline phase maps in an integrated fashion.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 62
DOI: 10.1107/S1600576714008218
|
|
|
“Resonant backward scattering of light by a subwavelength metallic slit with two open sides”. Kukhlevsky SV, Mechler M, Csapó, L, Janssens K, Samek O, Physical review : B : condensed matter and materials physics 72, 165421 (2005). http://doi.org/10.1103/PHYSREVB.72.165421
Abstract: The backward scattering of TM-polarized light by a two-side-open subwavelength slit in a metal film is analyzed. We show that the reflection coefficient versus wavelength possesses a Fabry-Perot-like dependence that is similar to the anomalous behavior of transmission reported in the study [Y. Takakura, Phys. Rev. Lett. 86, 5601 (2001)]. The open slit totally reflects the light at the near-to-resonance wavelengths. In addition, we show that the interference of incident and resonantly backward-scattered light produces in the near-field diffraction zone a spatially localized wave whose intensity is 10103 times greater than the incident wave, but one order of magnitude smaller than the intracavity intensity. The amplitude and phase of the resonant wave at the slit entrance and exit are different from that of a Fabry-Perot cavity.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.836
Times cited: 7
DOI: 10.1103/PHYSREVB.72.165421
|
|
|
“Enhanced transmission versus localization of a light pulse by a subwavelength metal slit”. Kukhlevsky SV, Mechler M, Csapo L, Janssens K, Samek O, Physical review : B : condensed matter and materials physics 70, 195428 (2004). http://doi.org/10.1103/PHYSREVB.70.195428
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.836
Times cited: 17
DOI: 10.1103/PHYSREVB.70.195428
|
|
|
“Comparison of spectroscopic techniques combined with chemometrics for cocaine powder analysis”. Eliaerts J, Meert N, Dardenne P, Baeten V, Pierna J-AF, Van Durme F, De Wael K, Samyn N, Journal Of Analytical Toxicology 44, 851 (2020). http://doi.org/10.1093/JAT/BKAA101
Abstract: Spectroscopic techniques combined with chemometrics are a promising tool for analysis of seized drug powders. In this study, the performance of three spectroscopic techniques [Mid-InfraRed (MIR), Raman and Near-InfraRed (NIR)] was compared. In total, 364 seized powders were analyzed and consisted of 276 cocaine powders (with concentrations ranging from 4 to 99 w%) and 88 powders without cocaine. A classification model (using Support Vector Machines [SVM] discriminant analysis) and a quantification model (using SVM regression) were constructed with each spectral dataset in order to discriminate cocaine powders from other powders and quantify cocaine in powders classified as cocaine positive. The performances of the models were compared with gas chromatography coupled with mass spectrometry (GC-MS) and gas chromatography with flame-ionization detection (GC-FID). Different evaluation criteria were used: number of false negatives (FNs), number of false positives (FPs), accuracy, root mean square error of cross-validation (RMSECV) and determination coefficients (R-2). Ten colored powders were excluded from the classification data set due to fluorescence background observed in Raman spectra. For the classification, the best accuracy (99.7%) was obtained with MIR spectra. With Raman and NIR spectra, the accuracy was 99.5% and 98.9%, respectively. For the quantification, the best results were obtained with NIR spectra. The cocaine content was determined with a RMSECV of 3.79% and a R-2 of 0.97. The performance of MIR and Raman to predict cocaine concentrations was lower than NIR, with RMSECV of 6.76% and 6.79%, respectively and both with a R-2 of 0.90. The three spectroscopic techniques can be applied for both classification and quantification of cocaine, but some differences in performance were detected. The best classification was obtained with MIR spectra. For quantification, however, the RMSECV of MIR and Raman was twice as high in comparison with NIR. Spectroscopic techniques combined with chemometrics can reduce the workload for confirmation analysis (e.g., chromatography based) and therefore save time and resources.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.5
DOI: 10.1093/JAT/BKAA101
|
|