“Ultrastructural localization of aluminum in patients with dialysis-associated osteomalacia”. Verbueken AH, van de Vijver FL, Van Grieken RE, Paulus GJ, Visser WJ, d'Haese P, de Broe ME, Clinical chemistry : international journal of laboratory medicine and molecular diagnostics 30, 763 (1984)
Abstract: Using laser microprobe mass analysis, we studied the ultrastructural localization of aluminum in liver and bone tissue of chronic-hemodialysis patients with proven aluminum-induced osteomalacia. In the liver, aluminum was observed to be almost exclusively associated with iron. Detectable aluminum and large amounts of iron were found in lysosomes of both hepatocytes and Kupffer cells. In bone, aluminum was localized at the osteoid/calcified-bone interface and also was associated with iron in some cases.
Keywords: A1 Journal article; Pharmacology. Therapy; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Ultrastructural localization of aluminium in liver of aluminium maltol-treated rabbits by laser microprobe mass analysis”. Vandeputte D, Van Grieken RE, Jacob WA, Savory J, Bertholf RL, Wills MR, Biomedical and environmental mass spectrometry 18, 598 (1989). http://doi.org/10.1002/BMS.1200180815
Abstract: By means of laser microprobe mass analysis (LAMMA), we have studied the ultrastructural localization of aluminium in livers of aluminium maltol-treated rabbits. This animal model was developed to study long-term aluminium toxicity using systemic (intravenous) administration of aluminium. We could only detect aluminium in electron-dense inclusion bodies found in large, sometimes multinucleated cells. These results prove that the actual observation of aluminium deposits in liver with LAMMA gives more information than bulk analysis and can be very useful to explore mechanisms of toxicity.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200180815
|
“Ultra-thin window electron probe microanalysis of suspended particles in tributaries of Lake Baikal, Siberia”. Semenov MY, Spolnik Z, Granina L, Van Grieken R, International journal of environmental analytical chemistry 85, 377 (2005). http://doi.org/10.1080/03067310500053944
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067310500053944
|
“Two fragments of mold-blown glass beakers with Greek inscriptions from Tongeren (Belgium)”. Cosyns P, Vanderhoeven A, Vynckier G, Janssens K, Schalm O, Vanderlinden V, Journal of glass studies 47, 179 (2005)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Tuning the turnover frequency and selectivity of photocatalytic CO2 reduction to CO and methane using platinum and palladium nanoparticles on Ti-Beta zeolites”. Blommaerts N, Hoeven N, Arenas Esteban D, Campos R, Mertens M, Borah R, Glisenti A, De Wael K, Bals S, Lenaerts S, Verbruggen SW, Cool P, Chemical Engineering Journal 410, 128234 (2021). http://doi.org/10.1016/j.cej.2020.128234
Abstract: A Ti-Beta zeolite was used in gas phase photocatalytic CO2 reduction to reduce the charge recombination rate and increase the surface area compared to P25 as commercial benchmark, reaching 607 m2 g-1. By adding Pt nanoparticles, the selectivity can be tuned toward CO, reaching a value of 92% and a turnover frequency (TOF) of 96 µmol.gcat-1.h-1, nearly an order of magnitude higher in comparison with P25. By adding Pd nanoparticles the selectivity can be shifted from CO (70% for a bare Ti-Beta zeolite), toward CH4 as the prevalent species (60%). In this way, the selectivity toward CO or CH4 can be tuned by either using Pt or Pd. The TOF values obtained in this work outperform reported state-of-the-art values in similar research. The improved activity by adding the nanoparticles was attributed to an improved charge separation efficiency, together with a plasmonic contribution of the metal nanoparticles under the applied experimental conditions.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL); Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.216
Times cited: 15
DOI: 10.1016/j.cej.2020.128234
|
“Trend analysis of the published concentrations of heavy metals in aerosols above the North Sea and the English Channel for the period 1971-1994”. Hoornaert S, Treiger B, Van Grieken R, Laane R, Environmental reviews 7, 191 (1999)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Transposing testing from lab to on-site environment : a case of cocaine powder sampling”. Van Loon J, De Jong M, De Wael K, Du Bois E, (2020)
Abstract: This paper reports on the transition process to convert a specific lab technique to the on-site, real-life environment. Bringing a lab test to an on-site environment involves many difficulties regarding to the context, people skills and environmental support. Within this project, a case about sampling for an electrochemical measurement, was investigated as a basis to reason upon some general conclusions related to the process of transposing lab-tests to an on-site environment. The current lab test was analysed and compared with a focus group discussion with future users. Based on the findings, assumptions for the new sampling technique in the specific case were formulated. New low-tech methods to achieve the sampling were extensively tested and verified. Starting from this chosen case an argumentation was set up to generalise the conclusions, by reasoning on other cases of products that already passed this transition to the field. Based on a comparison, we could discuss that the selected parameters related to impact of the context environment, of the people that should handle the tests, related to the reasons for transposing the technology, and related to the technology that will be transposed to the on-site environment, were of importance of almost all cases and can therefore be considered as context-independent and related to the transfer to on-site testing.
Keywords: P3 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Product development
|
“Transport and fractionation of Pb in river sediments from the Indian sub-continent”. Subramanian V, Van Grieken R, Van 't dack L, Journal of the Geological Society of India 30, 217 (1987)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Transport and deposition of airborne pollutants in exhibition areas located in historical buildings: study in Wawel Castle Museum in Cracow, Poland”. Worobiec A, Samek J, Krata A, van Meel K, Krupińska B, Stefaniak EA, Karaszkiewicz P, Van Grieken R, Journal of cultural heritage 11, 354 (2010). http://doi.org/10.1016/J.CULHER.2009.11.009
Abstract: Historical buildings and castles that have been turned nowadays into museums, as an exhibition area for precious cultural heritage (CH) items, need more attention since they are CH objects by themselves. Moreover, the preservation techniques require often, significant interventions; however such changes are not always possible or are very limited. The aim of the present study was to investigate the influence of outdoor air pollution on the composition of particulate matter and gases inside the museum of Wawel Castle in Cracow, Poland. During this study a combination of micro and trace analysis techniques were applied, including energy dispersive X-ray fluorescence (EDXRF) and electron probe microanalysis (EPMA). An intensive transport of air pollutants coupled with accumulation of the particles inside the museum was noticed (considerably higher in winter than summer). A high content of carbon and organic matter agglomerated with inorganic particles was determined. Those particles are of special concern because of their adhesive properties and reactivity. It was also noted that the conditions inside the museum favour the reaction of the particles with gaseous pollutants. It was especially the case for nitrate particles.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.CULHER.2009.11.009
|
“Transmission and reflection mode macroscopic x-ray powder diffraction imaging for the noninvasive visualization of paint degradation in still life paintings by Jan Davidsz. de Heem”. Vanmeert F, De Keyser N, van Loon A, Klaassen L, Noble P, Janssens K, Analytical chemistry 91, 7153 (2019). http://doi.org/10.1021/ACS.ANALCHEM.9B00328
Abstract: The use of noninvasive chemical imaging techniques is becoming more widespread for the study of cultural heritage artifacts. Recently a mobile instrument for macroscopic X-ray powder diffraction (MA-XRPD) scanning was developed, which is capable of visualizing the distribution of crystalline (pigment) phases in quasi-flat-painted artifacts. In this study, MA-XRPD is used in both transmission and reflection mode for the analysis of three 17th century still life paintings, two paintings by Jan Davidsz. de Heem (1606-1684) and one copy painting after De Heem by an unknown artist. MA-XRPD allowed to reveal and map the presence of in situ-formed alteration products. In the works examined, two rare lead arsenate minerals, schultenite (PbHAsO4) and mimetite (Pb-5(AsO4)(3)Cl), were encountered, both at and below the paint surface; they are considered to be degradation products of the pigments realgar (alpha-As4S4) and orpiment (As2S3). In transmission mode, the depletion of lead white, present in the (second) ground layer, could be seen, illustrating the intrusive nature of this degradation process. In reflection mode, several sulfate salts, palmierite (K2Pb(SO4)(2)), syngenite (K2Ca(SO4)(2)center dot H2O), and gypsum (CaSO4 center dot 2H(2)O), could be detected, in particular, at the (top) surface of the copy painting. Estimates for the information depth and sensitivity of both transmission and reflection mode MA-XRPD for various pigments have been made. The possibility of MA-XRPD to allow for noninvasive identification and visualization of alteration products is considered a significant advantage and unique feature of this method. MA-XRPD can thus provide highly relevant information for assessing the conservation state of artworks and could guide possible future restoration treatments.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 5
DOI: 10.1021/ACS.ANALCHEM.9B00328
|
“Tracing the metal pollution history of the Tisza River through the analysis of a sediment depth profile”. Nguyen HL, Braun M, Szaloki I, Baeyens W, Van Grieken R, Leermakers M, Water, air and soil pollution 200, 119 (2009). http://doi.org/10.1007/S11270-008-9898-2
Abstract: The vertical profiles of 20 major and trace metals were investigated along a 180-cm-long sediment core, which was sampled at Kiss-Janosne-Holt Tisza, an oxbow lake located in the upper part of the Tisza River in Hungary. The vertical profiles showed sharp peaks at different depths, reflecting historical pollution events and unusual changes of river water characteristics. Five different groups of metals, containing metals which were strongly correlated and showing a similar behaviour, could be distinguished by factor analysis. Six areas, with variable degrees and types of contamination, were classified in the sediment core with cluster analysis. The most polluted sections were found in the upper 50-cm part (significantly contaminated by Cu, Zn, Pb, Cd and Hg) and the deeper 100120-cm part (characterised by high concentrations of metals associated with mining activities, such as Fe and Mn, as well as Cu, Zn and Pb). In recent years, important pollution events, such as the one which took place in March of 2000, were the reason for pollution of the upper sediment layers, whereas mining activities during the last century were responsible for the pollution of the deeper core sections.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S11270-008-9898-2
|
“Trace-level microanalysis of Roman glass from Khirbet Qumran, Israel”. Aerts A, Janssens K, Adams F, Journal of archaeological science 26, 883 (1999). http://doi.org/10.1006/JASC.1999.0397
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.602
DOI: 10.1006/JASC.1999.0397
|
“Trace-level micro-XANES by means of bending magnets radiation focused with a polycapillary lens”. Vincze L, Janssens K, Wei F, Proost K, Vekemans B, Vittiglio G, Yan Y, Falkenberg G (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace-elemental anomalies in surface water near a small lead-zinc mineralization at Menez-Albot (Brittany, France)”. Vandelannoote R, Blommaert W, Sadurski A, Van 'T Dack L, Gijbels R, Van Grieken R, Bosch B, Leleu M, Rochon J, Sarcia C, Sureau JF;, Journal of geochemical exploration 20, 33 (1984). http://doi.org/10.1016/0375-6742(84)90088-8
Abstract: Sensitive multi-element analysis techniques were applied to water samples collected in the vicinity of a small Zn-Pb-Cu sulfide mineralization in the region of Menez-Albot (Finistère, France). The variation of the trace-element content along a local stream shows the presence of the mineralization, mainly through a simultaneous positive anomaly in solution for a group of about 10 elements (e.g. Ni, Cu, Zn, As, Sb) which are connected with this type of mineralization. The anomaly decreases steeply due to the influx of swamp water rich in Fe, Mn and organic matter. The precipitation barrier is reflected in the stream sediment composition. Contamination from fertilizers was observed in some samples.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.747
Times cited: 4
DOI: 10.1016/0375-6742(84)90088-8
|
“Trace metals in the St-Louis aerosol”. Winchester JW, Meinert DL, Nelson JW, Johansson TB, Van Grieken RE, Orsini C, Kaufmann HC, Akselsson R page 385 (1975).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace metal fractionation effects between sea water and aerosols from bubble bursting”. Van Grieken RE, Johansson TB, Winchester JW, Journal de recherches atmosphériques 8, 611 (1974)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace metal analysis of water containing humic substances by X-ray fluorescence”. Vanderborght BM, Van Grieken RE, International journal of environmental analytical chemistry 5, 221 (1978). http://doi.org/10.1080/03067317808071147
Abstract: Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067317808071147
|
“Trace metal analysis of sediments and particulate matter in sea water by energy-dispersive X-ray fluorescence”. Vanderstappen M, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 282, 25 (1976). http://doi.org/10.1007/BF00443774
Abstract: The capability of energy-dispersive X-ray fluorescence was investigated for fast and simple chemical analysis of trace elements in sediments and particulate matter in sea water. Nuclepore 0.4 μm pore-size membranes are recommended as optimal filters for a straightforward collection of suspended material. The collection of suspended trace metals by filtration seemed to give a sufficiently homogeneous filter load (s% <2.5). Data are presented on the concentrations of K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Rb and Sr with a fair precision (s% < 5.6) and accuracy.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00443774
|
“Trace elements in the atmospheric aerosols and soils in and around Recife, N.E. Brasil”. Costa Dantas C, Moura de Amorim W, Van 't dack L, Van Grieken R, Ciencia e cultura 32, 1525 (1980)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace elements and individual particle analysis of atmospheric aerosols from the Antarctic peninsula”. Artaxo P, Rabello MLC, Maenhaut W, Van Grieken R, Tellus 44b, 318 (1992)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Gijbels R, van Grieken R (1985) Trace element geochemistry in thermal waters from the Eastern Pyrenees. S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace element geochemistry in thermal waters from Plombières and Bains (Vosges)”. Gijbels R, van Grieken R, Blommaert W, Vandelannoote R, Van 't dack L, , 396 (1980)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace element geochemistry in thermal waters from Amélie-les-Bains (Eastern Pyrenees, France)”. Gijbels R, van Grieken R, Vandelannoote R, Blommaert W, Van 't dack L, , 123 (1980)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace element fingerprinting of façon-de-Venise glass”. Šmit Ž, Bulska E, Janssens K, Bulska E, Wagner B, Kos M, Lazar I, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 239, 94 (2005). http://doi.org/10.1016/J.NIMB.2005.06.182
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.109
Times cited: 27
DOI: 10.1016/J.NIMB.2005.06.182
|
“Trace element composition of Zaire suspended sediments”. Martin J-M, Thomas AJ, Van Grieken RE, Netherlands journal of sea research 12, 414 (1978). http://doi.org/10.1016/0077-7579(78)90043-1
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(78)90043-1
|
“Trace analysis of estuarine brown algae by energy-dispersive X-ray fluorescence”. Sauter L, Van der Ben D, Van Grieken R, X-ray spectrometry 8, 159 (1979). http://doi.org/10.1002/XRS.1300080405
Abstract: Brown algae, which are good indicators for estuarine metal pollution, can advantageously be analysed by energy-dispersive X-ray fluorescence. The use of thin film samples and samples of intermediate thickness has several advantages over the conventional thick pellet procedure. A quite homogeneous thin target is prepared by suspending 15 mg of dried and ground seaweed powder in bi-distilled water and evaporating the slurry on a 10 cm2 Mylar foil held in a Teflon ring. The effective sample weight in the beam is calculated by a procedure based on the scatter peaks in the spectrum. Sensitivities are typically in the 215 ppm range. The coefficient of variation per analysis averaged over ten elements amounts to 10%. The natural concentration variation in seaweed specimens at one location is 13%. Samples from locations in the more polluted western Scheldt estuary yield significantly higher values for several elements, relative to the eastern Scheldt sites. Possible trace element variations between the top and base of plants, and between different seaweed specimens and sampling seasons, are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300080405
|
“Trace analysis of environmental samples by X-ray emission spectroscopy”. Van Grieken RE, LaBrecque JJ page 101 (1985).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace analysis of benzene, toluene, ethylbenzene and xylene isomers in environmental samples by low-pressure gas chromatography-ion trap mass spectrometry”. Joos PE, Godoi AFL, de Jong R, de Zeeuw J, Van Grieken R, Journal of chromatography: A: bibliography section 985, 191 (2003). http://doi.org/10.1016/S0021-9673(02)01843-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0021-9673(02)01843-5
|
“Trace analysis allows to distinguish between Venetian and facon-de-Venise glass vessels of the 16th and 17th century”. de Raedt I, Janssens K, Veeckman J, Vincze L, Vekemans B, Jeffries T, Journal of analytical atomic spectrometry 16, 1012 (2001). http://doi.org/10.1039/B102597J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 49
DOI: 10.1039/B102597J
|
“Towards developing a screening strategy for ecstasy : revealing the electrochemical profile”. Thiruvottriyur Shanmugam S, Van Echelpoel R, Boeye G, Eliaerts J, Samanipour M, Ching HYV, Florea A, Van Doorslaer S, Van Durme F, Samyn N, Parrilla M, De Wael K, Chemelectrochem 8, 4826 (2021). http://doi.org/10.1002/CELC.202101198
Abstract: This article describes the development of an electrochemical screening strategy for 3,4-methylenedioxymethamphetamine (MDMA), the regular psychoactive compound in ecstasy (XTC) pills. We have investigated the specific electrochemical profile of MDMA and its electro-oxidation mechanisms at disposable graphite screen-printed electrodes. We have proved that the formation of a radical cation and subsequent reactions are indeed responsible for the electrode surface passivation, as evidenced by using electron paramagnetic resonance spectroscopy and electrochemistry. Thereafter, pure cutting agents and MDMA as well as simulated binary mixtures of compounds with MDMA were subjected to square wave voltammetry at pH 7 to understand the characteristic electrochemical profile. An additional measurement at pH 12 was able to resolve false positives and negatives occurring at pH 7. Finally, validation of the screening strategy was done by measuring a set of ecstasy street samples. Overall, our proposed electrochemical screening strategy has been demonstrated for the rapid, sensitive, and selective detection of MDMA, resolving most of the false positives and negatives given by the traditional Marquis color tests, thus exhibiting remarkable promises for the on-site screening of MDMA.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Organic synthesis (ORSY); Applied Electrochemistry & Catalysis (ELCAT); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.136
DOI: 10.1002/CELC.202101198
|