|
“Determining the molecular orientation on the metal nanoparticle surface through surface-enhanced Raman spectroscopy and density functional theory simulations”. Akbali B, Yagmurcukardes M, Peeters FM, Lin H-Y, Lin T-Y, Chen W-H, Maher S, Chen T-Y, Huang C-H, Journal Of Physical Chemistry C 125, 16289 (2021). http://doi.org/10.1021/ACS.JPCC.1C03931
Abstract: We report here the efficacy of surface-enhanced Raman spectroscopy (SERS) measurements as a probe for molecular orientation. 4-Aminobenzoic acid (PABA) on a surface consisting of silver (Ag) nanoparticles (NPs) is investigated. We find that the orientation of the PABA molecule on the SERS substrate is estimated based on the relative change in the magnitude of the C-H stretching bands on the SERS substrate, and it is found that the molecule assumes a horizontal orientation on the Ag-NP surface. The strong molecule-metal interaction is determined by an abnormal enhanced SERS band appearing at 980 cm(-1), and the peak is assigned to an out-of-plane amine vibrational mode, which is supported by our ab initio calculations. DFT-based Raman activity calculations corroborate the SERS results, revealing that (i) the PABA molecule attaches to the surface of Ag-NPs with its alpha dimers rather than single-molecule binding and (ii) the molecule preserves its alpha dimers in an aqueous environment. Our results demonstrate that SERS can be used to gain deeper insights into the molecular orientation on metal nanoparticle surfaces.
Keywords: A1 Journal article; Engineering sciences. Technology; Condensed Matter Theory (CMT)
Impact Factor: 4.536
Times cited: 9
DOI: 10.1021/ACS.JPCC.1C03931
|
|
|
“Determining stoichiometry and kinetics of two thermophilic nitrifying communities as a crucial step in the development of thermophilic nitrogen removal”. Vanderkerckhove TGL, Kerckhof F-M, De Mulder C, Vlaeminck SE, Boon N, Water research 156, 34 (2019). http://doi.org/10.1016/J.WATRES.2019.03.008
Abstract: Nitrification and denitrification, the key biological processes for thermophilic nitrogen removal, have separately been established in bioreactors at 50 °C. A well-characterized set of kinetic parameters is essential to integrate these processes while safeguarding the autotrophs performing nitrification. Knowledge on thermophilic nitrifying kinetics is restricted to isolated or highly enriched batch cultures, which do not represent bioreactor conditions. This study characterized the stoichiometry and kinetics of two thermophilic (50 °C) nitrifying communities. The most abundant ammonia oxidizing archaea (AOA) were related to the Nitrososphaera genus, clustering relatively far from known species Nitrososphaera gargensis (95.5% 16S rRNA gene sequence identity). The most abundant nitrite oxidizing bacteria (NOB) were related to Nitrospira calida (97% 16S rRNA gene sequence identity). The nitrification biomass yield was 0.200.24 g VSS g−1 N, resulting mainly from a high AOA yield (0.160.20 g VSS g−1 N), which was reflected in a high AOA abundance in the community (5776%) compared to NOB (511%). Batch-wise determination of decay rates (AOA: 0.230.29 d−1; NOB: 0.320.43 d−1) rendered an overestimation compared to in situ estimations of overall decay rate (0.0260.078 d−1). Possibly, the inactivation rate rather than the actual decay rate was determined in batch experiments. Maximum growth rates of AOA and NOB were 0.120.15 d−1 and 0.130.33 d−1 respectively. NOB were susceptible to nitrite, opening up opportunities for shortcut nitrogen removal. However, NOB had a similar growth rate and oxygen affinity (0.150.55 mg O2 L−1) as AOA and were resilient towards free ammonia (IC50 > 16 mg NH3-N L−1). This might complicate NOB outselection using common practices to establish shortcut nitrogen removal (SRT control; aeration control; free ammonia shocks). Overall, the obtained insights can assist in integrating thermophilic conversions and facilitate single-sludge nitrification/denitrification.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1016/J.WATRES.2019.03.008
|
|
|
“Determining potential locations for biomass valorization using a macro screening approach”. Van Dael M, Van Passel S, Pelkmans L, Guisson R, Swinnen G, Schreurs E, Biomass &, Bioenergy 45, 175 (2012). http://doi.org/10.1016/J.BIOMBIOE.2012.06.001
Abstract: European policy states that by 2020 at least 20% of final energy consumption should come from renewable energy sources. Biomass as a renewable energy source cannot be disregarded in order to attain this target. In this study a macro screening approach is developed to determine potential locations for biomass valorization in a specified region. The approach consists of five steps: (1) criteria determination, (2) data gathering, (3) weight assignment, (4) final score, (5) spatial representation. The resulting outcome provides a first well balanced scan of the possibilities for energy production using regional biomass. This way policy makers and investors can be supported and motivated to study the possibilities of building energy production plants at specific locations in more detail, which can be described as a 'micro-screening'. In our case study the approach is applied to determine the potentially interesting locations to establish a biomass project. The region has been limited to the forty-four communities in the province of Limburg (Belgium). The macro screening approach has shown to be very effective since the amount of interesting locations has been reduced drastically. (c) 2012 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; Engineering Management (ENM)
Impact Factor: 3.219
Times cited: 23
DOI: 10.1016/J.BIOMBIOE.2012.06.001
|
|
|
“Determining oxygen relaxations at an interface: A comparative study between transmission electron microscopy techniques”. Gauquelin N, van den Bos KHW, Béché, A, Krause FF, Lobato I, Lazar S, Rosenauer A, Van Aert S, Verbeeck J, Ultramicroscopy 181, 178 (2017). http://doi.org/10.1016/j.ultramic.2017.06.002
Abstract: Nowadays, aberration corrected transmission electron microscopy (TEM) is a popular method to characterise nanomaterials at the atomic scale. Here, atomically resolved images of nanomaterials are acquired, where the contrast depends on the illumination, imaging and detector conditions of the microscope. Visualization of light elements is possible when using low angle annular dark field (LAADF) STEM, annular bright field (ABF) STEM, integrated differential phase contrast (iDPC) STEM, negative spherical aberration imaging (NCSI) and imaging STEM (ISTEM). In this work, images of a NdGaO3-La0.67Sr0.33MnO3 (NGO-LSMO) interface are quantitatively evaluated by using statistical parameter estimation theory. For imaging light elements, all techniques are providing reliable results, while the techniques based on interference contrast, NCSI and ISTEM, are less robust in terms of accuracy for extracting heavy column locations. In term of precision, sample drift and scan distortions mainly limits the STEM based techniques as compared to NCSI. Post processing techniques can, however, partially compensate for this. In order to provide an outlook to the future, simulated images of NGO, in which the unavoidable presence of Poisson noise is taken into account, are used to determine the ultimate precision. In this future counting noise limited scenario, NCSI and ISTEM imaging will provide more precise values as compared to the other techniques, which can be related to the mechanisms behind the image recording.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 34
DOI: 10.1016/j.ultramic.2017.06.002
|
|
|
“Determining groundwater-surface water exchange from temperature-time series : combining a local polynomial method with a maximum likelihood estimator”. Vandersteen G, Schneidewind U, Anibas C, Schmidt C, Seuntjens P, Batelaan O, Water resources research 51, 922 (2015). http://doi.org/10.1002/2014WR015994
Abstract: The use of temperature-time series measured in streambed sediments as input to coupled water flow and heat transport models has become standard when quantifying vertical groundwater-surface water exchange fluxes. We develop a novel methodology, called LPML, to estimate the parameters for 1-D water flow and heat transport by combining a local polynomial (LP) signal processing technique with a maximum likelihood (ML) estimator. The LP method is used to estimate the frequency response functions (FRFs) and their uncertainties between the streambed top and several locations within the streambed from measured temperature-time series data. Additionally, we obtain the analytical expression of the FRFs assuming a pure sinusoidal input. The estimated and analytical FRFs are used in an ML estimator to deduce vertical groundwater-surface water exchange flux and its uncertainty as well as information regarding model quality. The LPML method is tested and verified with the heat transport models STRIVE and VFLUX. We demonstrate that the LPML method can correctly reproduce a priori known fluxes and thermal conductivities and also show that the LPML method can estimate averaged and time-variable fluxes from periodic and nonperiodic temperature records. The LPML method allows for a fast computation of exchange fluxes as well as model and parameter uncertainties from many temperature sensors. Moreover, it can utilize a broad frequency spectrum beyond the diel signal commonly used for flux calculations.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1002/2014WR015994
|
|
|
“Determination of Zn distribution inside edible plants grown on a polluted soil amended with compost by XRF microtomography”. Terzano R, al Chami Z, Vekemans B, Janssens K, Miano T, Ruggiero P (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of ultra-trace levels of palladium in environenmental samples by graphite furnace atomic spectrometry techniques”. Bencs L, Ravindra K, Van Grieken R page 173 (2006).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of ultimate leakage through rutile TiO2 and tetragonal ZrO2 from ab initio complex band calculations”. Clima S, Kaczer B, Govoreanu B, Popovici M, Swerts J, Verhulst AS, Jurczak M, De Gendt S, Pourtois G, IEEE electron device letters 34, 402 (2013). http://doi.org/10.1109/LED.2013.2238885
Abstract: First-principle complex band structures have been computed for rutile TiO2 and tetragonal ZrO2 insulating materials that are of current technological relevance to dynamic random accessmemorymetal-insulator-metal (MIM) capacitors. From the magnitude of the complex wave vectors in different orientations, the most penetrating orientations have been identified. Tunneling effective masses m(tunnel) have been extracted, are shown to be a crucial parameter for the intrinsic leakage, and are identified to be an important parameter in further scaling of MIM capacitors.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.048
Times cited: 3
DOI: 10.1109/LED.2013.2238885
|
|
|
“Determination of trace selenium in biological material by preconcentration and X-ray emission spectrometry”. Robberecht H, Van Grieken R, Analytica chimica acta 147, 113 (1983). http://doi.org/10.1016/0003-2670(83)80077-4
Abstract: Selenium is determined in the ng g−1 to μg g−1 range in biological and environmental samples. A wet digestion procedure was optimized with respect to volatility losses and recovery yields, by using 75Se metabolically incorporated into rat organs. Selenium is preconcentrated from the digestion liquid by a two-step reduction with 4 M HCl and ascorbic acid. The colloidal selenium formed is adsorbed on activated carbon and filtered on a Nucleopore membrane for measurement by energy-dispersive x-ray fluorescence. Almost complete recovery was obtained, and the detection limit was 20 ng, corresponding to 10 ng g−1 for a 2-g sample. Biological reference materials were analyzed with satisfactory results, and the accuracy of the method was good.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(83)80077-4
|
|
|
“Determination of trace metals in rain water by differential-pulse stripping voltammetry”. Vos L, Komy G, Reggers G, Roekens E, Van Grieken R, Analytica chimica acta 184, 271 (1986). http://doi.org/10.1016/S0003-2670(00)86491-0
Abstract: Differential-pulse stripping voltammetry is applied to measure zinc, cadmium, lead and copper by anodic stripping and selenium(IV) by cathodic stripping in rain water at pH 2; subsequently, at pH 9,1, manganese is measured by anodic stripping on the same portion, and cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The instrumental parameters are optimized. The linear ranges, mutual interferences and detection limits are studied. Excellent accuracy is demonstrated; the standard deviation is around 15% at 2.550 μg l−1 levels. The method is shown to be applicable for rain water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)86491-0
|
|
|
“Determination of trace elements in organic matrices by grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken R, Analytica chimica acta 401, 293 (1999). http://doi.org/10.1016/S0003-2670(99)00471-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(99)00471-7
|
|
|
“Determination of total selenium content in cereals and bakery products by flow injection hydride generation graphite furnace atomic absorption spectrometry applying in-situ trapping on iridium-treated graphite platforms”. Ajtony Z, Szoboszlai N, Bella Z, Bolla S, Szakál P, Bencs L, Microchimica acta 150, 1 (2005). http://doi.org/10.1007/S00604-005-0330-Y
Abstract: A flow injection hydride generation graphite furnace atomic absorption spectrometric (FI-HG-GFAAS) method was applied to the determination of Se in Se-doped and undoped cereals and bakery products. For the purpose of doping, the soils used for the cultivation of the cereals were dosed with Se- doped foliar fertilizers. The samples were dissolved in a mixture of HNO(3) and H(2)O(2) solutions using micro-waveassisted digestion. The decomposition of H(2)Se generated from the sample solutions and the trapping of elemental Se were performed at a temperature of 300 degrees C on an Ir-pretreated integrated graphite platform of a transversally heated graphite atomizer(THGA). For release of the trapped Se within a fairly short atomization time (5s), an atomization temperature of 2200 degrees C was observed to be optimal. The overall efficiency of hydride generation, transport and trapping was similar to 86%. The upper limit of the linear dynamic range of calibration was 10 mu gL(-1), which corresponds to 0.5 mu g g(-1) for solid samples. Recovery of the samples spiked with Se(VI) solutions was found to be 93 +/- 6% on average. The relative standard deviation of the determinations was less than 8%. The limit of detection was found to be 0.06 mu gL(-1), corresponding to 3 ng g(-1) for solid samples. The accuracy of the method was verified with the use of IAEA-155 ( whey powder) certified reference material. End-capped THGA tubes resulted in an extension of the linear calibration range compared to that of standard THGAs. The Se content in bakery products made of undoped cereals ranged from 7.7 to 68 ng g(-1) ( wet weight) in 18 samples, whereas the Se content of the corresponding cereals was found to be below 100 ng g(-1) ( wet weight). The Se level of cereals grown on soils treated with Se- doped fertilizers ranged from 128 to 1046 ng g(-1) ( wet weight), and it depended linearly on the Se concentration of the corresponding foliar fertilizer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-005-0330-Y
|
|
|
“Determination of the silver sulphide cluster size distribution via computer simulations”. Charlier E, Gijbels R, Van Doorselaer M, De Keyzer R page 85 (2000).
Abstract: Addition of a labile sulphur donor to light sensitive silver halide microcrystals results in the formation of a distribution of silver sulphide clusters on the crystal surface. These silver sulphide clusters enhance the efficiency of image formation during the photographic process. Their activity towards the capturing of light photons, however, is very critical to their size (aggregation number) and concentration. By incorporating gold ions into silver sulphide clusters it was possible to monitor the size distribution by measuring the amount of gold reacted. From these experiments, no evidence was found for aggregation of the reacted sulphur entities on the surface. The uptake of gold ions at different sulphur concentrations could well be fitted with a simulated size distribution when a catalyzed deposition of sulphur was assumed, with a reactivity of the surface equal to 1.0 % for the microcrystals studied. From a simulation of the silver sulphide cluster size distribution a correlation could also be found between increasing aggregation numbers and the absorption at increasing wavelengths in diffuse reflectance spectroscopy.
Keywords: H1 Book chapter; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Determination of the mean inner potential in III-V semiconductors, Si and Ge by density functional theory and electron holography”. Kruse P, Schowalter M, Lamoen D, Rosenauer A, Gerthsen D, Ultramicroscopy 106, 105 (2006). http://doi.org/10.1016/j.ultramic.2005.06.057
Keywords: A1 Journal article; Electron Microscopy for Materials Science (EMAT);
Impact Factor: 2.843
Times cited: 50
DOI: 10.1016/j.ultramic.2005.06.057
|
|
|
“Determination of the electron effective band mass in amorphous carbon from density-functional theory calculations”. Titantah JT, Lamoen D, Physical review : B : condensed matter and materials physics 70, 033101 (2004). http://doi.org/10.1103/PhysRevB.70.033101
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 3.836
Times cited: 24
DOI: 10.1103/PhysRevB.70.033101
|
|
|
“Determination of the cd-bearing phases in municipal solid waste and Biomass single fly ash particles using SR-mu XRF Spectroscopy”. Camerani MC, Somogyi A, Vekemans B, Ansell S, Simionovici AS, Steenari B-M, Panas I, Analytical chemistry 79, 6496 (2007). http://doi.org/10.1021/AC070206J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC070206J
|
|
|
“Determination of the atomic width of an APB in ordered CoPt using quantified HAADF-STEM”. Akamine H, Van den Bos KHW, Gauquelin N, Farjami S, Van Aert S, Schryvers D, Nishida M, Journal of alloys and compounds 644, 570 (2015). http://doi.org/10.1016/j.jallcom.2015.04.205
Abstract: Anti-phase boundaries (APBs) in an ordered CoPt alloy are planar defects which disturb the ordered structure in their vicinity and decrease the magnetic properties. However, it has not yet been clarified to what extend the APBs disturb the ordering. In this study, high-resolution HAADF-STEM images are statistically analysed based on the image intensities estimated by the statistical parameter estimation theory. In the procedure, averaging intensities, fitting the intensity profiles to specific functions, and assessment based on a statistical test are performed. As a result, the APBs in the stable CoPt are found to be characterised by two atomic planes, and a contrast transition range as well as the centre of an inclined APB is determined. These results show that the APBs are quite sharp and therefore may have no notable effect on the net magnetic properties due to their small volume fraction. (C) 2015 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 3.133
Times cited: 12
DOI: 10.1016/j.jallcom.2015.04.205
|
|
|
“Determination of spinel content in cycled Li1.2Ni0.13Mn0.54Co0.13O2 using three-dimensional electron diffraction and precession electron diffraction”. Quintelier M, Perkisas T, Poppe R, Batuk M, Hendrickx M, Hadermann J, Symmetry-Basel 13, 1989 (2021). http://doi.org/10.3390/SYM13111989
Abstract: Among lithium battery cathode materials, Li1.2Ni0.13Mn0.54Co0.13O2 (LR-NMC) has a high theoretical capacity, but suffers from voltage and capacity fade during cycling. This is partially ascribed to transition metal cation migration, which involves the local transformation of the honeycomb layered structure to spinel-like nano-domains. Determination of the honeycomb layered/spinel phase ratio from powder X-ray diffraction data is hindered by the nanoscale of the functional material and the domains, diverse types of twinning, stacking faults, and the possible presence of the rock salt phase. Determining the phase ratio from transmission electron microscopy imaging can only be done for thin regions near the surfaces of the crystals, and the intense beam that is needed for imaging induces the same transformation to spinel as cycling does. In this article, it is demonstrated that the low electron dose sufficient for electron diffraction allows the collection of data without inducing a phase transformation. Using calculated electron diffraction patterns, we demonstrate that it is possible to determine the volume ratio of the different phases in the particles using a pair-wise comparison of the intensities of the reflections. Using this method, the volume ratio of spinel structure to honeycomb layered structure is determined for a submicron sized crystal from experimental three-dimensional electron diffraction (3D ED) and precession electron diffraction (PED) data. Both twinning and the possible presence of the rock salt phase are taken into account. After 150 charge-discharge cycles, 4% of the volume in LR-NMC particles was transformed irreversibly from the honeycomb layered structure to the spinel structure. The proposed method would be applicable to other multi-phase materials as well.
Keywords: A1 Journal article; Engineering sciences. Technology; Engineering Management (ENM); Electron microscopy for materials research (EMAT)
Impact Factor: 1.457
DOI: 10.3390/SYM13111989
|
|
|
“Determination of size, morphology, and nitrogen impurity location in treated detonation nanodiamond by transmission electron microscopy”. Turner S, Lebedev OI, Shenderova O, Vlasov II, Verbeeck J, Van Tendeloo G, Advanced functional materials 19, 2116 (2009). http://doi.org/10.1002/adfm.200801872
Abstract: Size, morphology, and nitrogen impurity location, all of which are all thought to be related to the luminescent properties of detonation nanodiamonds, are determined in several detonation nanodiamond samples using a combination of transmission electron microscopy techniques. Results obtained from annealed and cleaned detonation nanodiamond samples are compared to results from conventionally purified detonation nanodiamond. Detailed electron energy loss spectroscopy combined with model-based quantification provides direct evidence for the sp3 like embedding of nitrogen impurities into the diamond cores of all the studied nanodiamond samples. Simultaneously, the structure and morphology of the cleaned detonation nanodiamond particles are studied using high resolution transmission electron microscopy. The results show that the size and morphology of detonation nanodiamonds can be modified by temperature treatment and that by applying a special cleaning procedure after temperature treatment, nanodiamond particles with clean facets almost free from sp2 carbon can be prepared. These clean facets are clear evidence that nanodiamond cores are not necessarily in coexistence with a graphitic shell of non-diamond carbon.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 12.124
Times cited: 100
DOI: 10.1002/adfm.200801872
|
|
|
“Determination of silicon in organic matrices with grazing-emission X-ray fluorescence spectrometry”. Claes M, van Dyck K, Deelstra H, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 54, 1517 (1999). http://doi.org/10.1016/S0584-8547(99)00098-1
Abstract: The potential of a prototype grazing-emission X-ray fluorescence spectrometer for reliable analysis of sample solutions, obtained by pressurized microwave oven digestion of Si-spiked organic and biological materials, was investigated as part of an inter-laboratory study. The fact that this grazing-emission technique is based on the total reflection phenomenon and wavelength-dispersive detection, gives it the benefit to determine light elements in a sensitive way. Results of the determination of silicon in pork liver, cellulose, urine, serum, spinach, beer, mineral water and horsetail (dry plant extract) samples are presented. Some of the results are compared with those obtained with other analytical techniques. The study proved that determination of silicon traces in biological matrices represents an extremely difficult task, however, measurements of silicon are achieved with acceptable precision. The most important problems still arise when sample pre-treatment is needed prior to analysis. (C) 1999 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00098-1
|
|
|
“Determination of silicon in natural and pollution aerosols by 14-MeV neutron activation analysis”. Gijbels R, Dams R, Analytica chimica acta 63, 369 (1973). http://doi.org/10.1016/S0003-2670(01)82362-X
Abstract: The determination of silicon via the 28Si(n,p)28 Al reaction by means of 14-MeV neutrons is applied to the analysis of pollution and natural aerosols. A Whatman 41 filter (40 cm2) on which airborne particulate material has been collected is compressed into a 3 × 12.7 mm pellet. Standards are prepared in the same way from clean filters spiked with a silicate solution. After a 50-s irradiation and a 75-s decay time, the sample is counted for 2 min with 5 × 5 NaI(Tl) well detector. The 1.779-MeV photopeak of 28Al is measured with a single channel sealer chain or with a multichannel analyser. The reproducibility, sensitivity and liability to interference from other elements were investigated for both counting systems. The homogeneity of the pellets and the filters was checked. The overall precision of one single-channel determination was estimated to be 3.5% after a 24-h high-volume sampling time. Samples collected in urban, industrial and remote areas with concentrations ranging from 0.05 to 15 μg Si m-3 air were analysed and the results are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 16
DOI: 10.1016/S0003-2670(01)82362-X
|
|
|
“Determination of selenium in blood components by X-ray emission spectrometry”. Robberecht H, Deelstra H, Van Grieken R, Biological trace element research 25, 149 (1990). http://doi.org/10.1007/BF02990412
Abstract: Sampling, storing, sample pretreatment, and experimental conditions for selenium (Se) determination in human serum, plasma, and whole blood by X-ray emission spectrometric (XRS) methods are described. Concentration levels in these biological fluids, found by this technique, are discussed and compared to values found by other techniques for the same healthy population group in the same area. XRS analysis of blood from patients with various pathological conditions is reviewed, with special attention to the relation of Se with the concentration level of other essential or nonessential trace elements.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02990412
|
|
|
“Determination of scandium in high-purity titanium using inductively coupled plasma mass spectrometry and glow discharge mass spectrometry as part of its certification as a reference material”. Held A, Taylor P, Ingelbrecht C, de Bièvre P, Broekaert J, van Straaten M, Gijbels R, Journal of analytical atomic spectrometry 10, 849 (1995). http://doi.org/10.1039/ja9951000849
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.466
Times cited: 6
DOI: 10.1039/ja9951000849
|
|
|
“Determination of sample thickness via scattered radiation in X-ray fluorescence spectrometry with filtered continuum excitation”. Araujo MF, van Espen P, Van Grieken R, X-ray spectrometry 19, 29 (1990). http://doi.org/10.1002/XRS.1300190107
Abstract: A semi-empirical approach is described for determining the mass per unit area of a sample being analysed. The method can be used to estimate the concentration of minor and trace elements in matrices containing a substantial amount of light elements. The procedure utilizes the coherently and incoherently scattered radiation induced in the sample by the filtered continuum radiation of a rhodium x-ray tube. The relationship between the intensity of the scattered radiation per unit mass and the average atomic number of the sample is established via calibration graphs, which can be applied for different x-ray tube voltages and for different primary beam filters. The overall procedure was validated by the analysis of several geological standards, deposited as thin slurries of unknown thickness either on Mylar foil or on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300190107
|
|
|
“Determination of rare earth elements in geological materials by total reflection X-ray fluorescence”. Muia LM, Van Grieken R, Analytica chimica acta 251, 177 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of protein-bound copper and zinc in some organs of the cuttlefish Sepia officinalis L”. Decleir W, Vlaeminck A, Geladi P, Van Grieken R, Comparative biochemistry and physiology : B : biochemistry and molecular biology 60, 347 (1978). http://doi.org/10.1016/0305-0491(78)90057-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0305-0491(78)90057-3
|
|
|
“Determination of precious metals in ores and rocks by thermal neutron activation/\gamma-spectrometry after preconcentration by nickel sulphide fire assay and coprecipitation with tellurium”. Shazali I, Van 't dack L, Gijbels R, Analytica chimica acta 196, 49 (1987). http://doi.org/10.1016/S0003-2670(00)83069-X
Abstract: The six platinum group elements (Ru, Rh, Pd, Os, Ir and Pt) can be determined in geological samples down to the μg kg−1 level, by using nickel sulphide fire assay and neutron activation of the residue ramaining after dissolution of the nickel sulphide button in concentrated hydrochloric acid. Losses for the platinum group elements during this dissolution step are usually insignificant, except when the elements are present at ultra-trace levels. The can be recovered from the filtrate by coprecipitation with tellerium. The latter approach also permits determination of silver, which is significantly lost in the hydrochloric acid treatment (recovery <98% instead of typically ≈ 10%). The coprecipitation with tellurium considerably improves the results for gold (recovery ≈ 95% instead of typically 75%).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 49
DOI: 10.1016/S0003-2670(00)83069-X
|
|
|
“Determination of platinum, palladium, and rhodium in automotive catalysts using high-energy secondary target X-ray fluorescence spectrometry”. van Meel K, Smekens A, Behets M, Kazandjian P, Van Grieken R, Analytical chemistry 79, 6383 (2007). http://doi.org/10.1021/AC070815R
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC070815R
|
|
|
van Grieken R, Gijbels R, Speecke A, Hoste J (1971) Determination of oxygen, silicon, phosphorus and copper in iron and steel by 14 MeV neutron activation analysis. S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of methanesulfonic acid and non-sea-salt sulfate in single marine aerosol particles”. Kolaitis LN, Bruynseels FJ, Van Grieken RE, Andreae MO, Environmental science and technology 23, 236 (1989). http://doi.org/10.1021/ES00179A018
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES00179A018
|
|