|
“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
|
|
“Evaluation of secondary cathodes for glow discharge mass spectrometry analysis of different nonconducting sample types”. Schelles W, de Gendt S, Müller V, Van Grieken R, Applied spectroscopy 49, 939 (1995). http://doi.org/10.1366/0003702953964741
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/0003702953964741
|
|
|
“Evaluation of multi-element analysis of blood serum by energy-dispersive x-ray spectrometry”. Robberecht H, Van Grieken R, Shani J, Barak S, Analytica chimica acta 136, 285 (1982). http://doi.org/10.1016/S0003-2670(01)95388-7
Abstract: Conventional energy-dispersive x-ray fluorescence is applied in the analysis of blood serum to give the concentrations of 710 elements simultaneously with minimal manipulation of the samples. Simple spotting onto a Mylar carrier of 250 μl of serum, doped with two internal standards, was chosen as the sample preparation step. Some 200 serum samples, analyzed in replicate (n = 26), were used to evaluate this procedure. The detection limits are 4 μg ml-1 for K and Ca, 0.50.2 μg ml-1 for Fe, Cu, Pb and Zn, and less than 0.1 μg ml-1 for Se, Rb and Sr. Well above these limits, the standard deviation is around 10%. Comparison with the results of other measurements on the same samples indicates an accuracy of that order. The simplicity and high throughput, and the possibility of automating the x.r.f. measurements, make the proposed procedure suitable for screening large numbers of sera.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95388-7
|
|
|
“Evaluation of energy-dispersive x-ray spectra of low-Z elements from electron-probe microanalysis of individual particles”. Osán J, de Hoog J, van Espen P, Szalóki I, Ro C-U, Van Grieken R, X-ray spectrometry 30, 419 (2001). http://doi.org/10.1002/XRS.523
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.523
|
|
|
“Evaluation of different techniques used to determine aluminium in patients with chronic renal failure”. Visser WJ, Van de Vyver FL, Verbueken AH, d'Haese P, Bekaert AB, Van Grieken RE, Duursma SA, de Broe ME, (1985)
Keywords: P3 Proceeding; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
|
|
“Evaluation of airborne particles at the Alhambra monument in Granada, Spain”. Horemans B, Cardell C, Bencs L, Kontozova-Deutsch V, De Wael K, Van Grieken R, Microchemical journal 99, 429 (2011). http://doi.org/10.1016/J.MICROC.2011.06.018
Abstract: As a part of an ongoing investigation regarding the air quality at the Alhambra monument (UNESCO World Cultural Heritage), indoor and outdoor atmospheric aerosols (PM1 and PM10-1) and pollutant gases (O3, NO2, SO2 and NH3) were studied during summer and winter. Bulk elements, ionic compounds and black carbon (BC) in aerosols were analyzed with X-ray fluorescence spectrometry, ion chromatography and aethalometry/reflectometry, respectively. Natural PM10-1 aerosols, such as carbonate-rich soil and sea salts, reacted with a typical urban atmosphere, producing a mixture of particulates with diverse chemical composition. The content/formation of secondary inorganic aerosols depended on the air temperature and absolute humidity. Ratios of typical mineral elements (i.e., Ti/Fe and Si/Fe) showed that Saharan dust events contribute to the composition of the observed mineral aerosol content. BC, V and Ni originated from diesel exhaust, while Cu, Cr, Pb and Zn came mainly from non-exhaust vehicular emissions. Weathering phenomena, such as blackening and pigment discoloration, which could arise from gradual aerosol deposition indoors, are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.034
Times cited: 39
DOI: 10.1016/J.MICROC.2011.06.018
|
|
|
“Estudio de la contaminacion del aire urbano en cuatro museos de Argentina”. Vazquez C, Boeykens S, Palacios O, Caracciolo N, Kontozova-Deutsch V, Krupińska B, Van Grieken R page 271 (2013).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Equilibrium constants for trace elements in natural waters”. Van 't dack L, Blommaert W, Vandelannoote R, Gijbels R, van Grieken R, Reviews in analytical chemistry 7, 297 (1983)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“EPXMA survey of shelf sediments (Southern Bight, North Sea): a glance beyond the XRD-invisible”. de Maeyer-Worobiec A, Dekov VM, Laane RWPM, Van Grieken R, Microchemical journal 91, 21 (2009). http://doi.org/10.1016/J.MICROC.2008.07.001
Abstract: Shelf sediments of the southern North Sea, were studied with a microanalytical [electron probe X-ray microanalysis (EPXMA)] and two bulk [X-ray diffraction (XRD) and X-ray fluorescence (XRF)] techniques. The investigation proved that the promptness of the microanalytical method is combined with a reasonable analytical reliability. XRD studies of such a type of sediments with monotonous mineral composition are not able to provide mineralogical information beyond the main well-crystalline minerals and the mineralogical quantitative characteristic of the sediment based on XRD estimations are incorrect. The EPXMA mineralogical interpretations are based on the statistical evaluation of a huge data set (thousands of mineral particles) and provide a rather correct quantitative determination of the main minerals. The comparative EPXMAXRF study revealed that the Al, Si, K, Ca, Fe and to some extent Ti contents estimated by EPXMA are fairly reliable. In this respect the accuracy of the EPXMA-based mineral identification of the pure silicates, pure aluminosilicates, and Al-, Ca-, Fe- and Ti-containing minerals with simple composition is very high. Mg-calcite, augite and apatite determinations are assessed to be correct. The supposed accuracy of the clay mineral determinations is slightly lower (7080%) than that of the other main minerals due to the complex and varying composition of the clays. The identification of XRD-invisible accessory minerals and quantification of their presence in the sediments is an essential advantage of the EPXMA, which makes it a useful approach in tracing the origin of the sediments, the pathways of their transport and the geochemical processes they have undergone. However, the EPXMA has several flaws, which need to be solved in the future sediment investigations: (1) calibration with natural standards is needed in order to provide a higher accuracy of the mineral determinations; (2) any EPXMA study of sediments needs to be secured with XRF examinations of selected samples since EPXMA gives only semi-quantitative information about the abundance of the elements; (3) ultra-thin window EPXMA of low-Z elements has to be used since some of them (O, C) are always present in the main sediment components: silicates, aluminosilicates, carbonates and metal oxyhydroxides; (4) the interpretations of the clay fraction have to be supported with detailed XRD investigations of selected samples, while the mineralogy of the silt and sand fractions needs to be backed up with optical microscopy studies. The information from different analytical techniques (EPXMA with XRFXRD-optical microscopy of selected samples) combined with the knowledge about the most possible minerals in a given environment, would give the most reliable results in studying mineralogical composition of shelf sediments.
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MICROC.2008.07.001
|
|
|
“Environmental problems”. Jambers W, Van Grieken RE page 803 (1997).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Environmental monitoring in four European museums”. Camuffo D, Van Grieken R, Busse H-J, Sturaro G, Valentino A, Bernardi A, Blades N, Shooter D, Gysels K, Deutsch F, Wieser M, Kim O, Ulrych U, Atmospheric environment : an international journal 35, S127 (2001)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Environmental conditions controlling the chemical weathering of the Madara Horseman monument, NE Bulgaria”. Delalieux F, Cardell C, Todorov V, Dekov V, Van Grieken R, Journal of cultural heritage 2, 43 (2001)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Environmental aerosol characterization by single particle analysis techniques”. Xhoffer C, Van Grieken R page 207 (1993).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Enrichment procedures for water analysis by X-ray energy spectrometry”. Van Grieken R, Bresseleers K, Smits J, Vanderborght B, Vanderstappen M, (1976)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Enrichment of trace metals in water by adsorption on activated carbon”. Vanderborght BM, Van Grieken RE, Analytical chemistry 49, 311 (1977)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Enrichment of trace anions from water with 2,2'-diaminodiethylamine cellulose filters”. Smits J, Van Grieken R, Analytica chimica acta 123, 9 (1981). http://doi.org/10.1016/S0003-2670(01)83152-4
Abstract: Cellulose filters with immobilized 2,2'-diaminodiethylamine (DEN) functional groups are studied for trace anion preconcentration from aqueous solution, with subsequent x-ray fluorescence measurements. For most oxoanions with a central metal atom, nearly quantitative collection can be achieved by 10-cm2 DEN filters under the following optimized conditions: pH 36, filtration rate up to 0.5 ml cm-2 min-1, and sample volume up to 100 ml cm-2. The collection yield is independent of the trace oxoanion concentration up to at least 1.5 μmol cm-2. Although the DEN filter exhibits some selectivity towards oxoanions with a central metal atom, ionic strength affects the results; the collection efficiency is strongly depressed with salt (e.g. NaCl) concentrations above 0.01 M. The applicability of the DEN filter in anion collection is therefore limited to dilute solutions.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)83152-4
|
|
|
“Enhancement of X-ray fluorescence intensity from an ultra-thin sandwiched layer at grazing-emission angles”. Tsuji K, Takenaka H, Wagatsuma K, de Bokx PK, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1881 (1999). http://doi.org/10.1016/S0584-8547(99)00143-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00143-3
|
|
|
“Enhancement of electron-induced X-ray intensity for single particles under grazing-exit conditions”. Tsuji K, Spolnik Z, Wagatsuma K, Zhang J, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1243 (1999). http://doi.org/10.1016/S0584-8547(99)00073-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00073-7
|
|
|
“Enhancement effect in X-ray fluorescence analysis of environmental samples of medium thickness”. Van Dyck PM, Török SB, Van Grieken RE, Analytical chemistry 58, 1761 (1986). http://doi.org/10.1021/AC00121A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00121A036
|
|
|
“Energy-dispersive X-ray spectrometry : present state and trends”. Van Grieken R, Markowicz A, Török S, Fresenius' Zeitschrift für analytische Chemie 324, 825 (1986). http://doi.org/10.1007/BF00473177
Abstract: Recent development, present state and expected future developments in energy-dispersive X-ray spectrometry are discussed. Attention is paid to the improvements in analytical selectivity, sensitivity, detection limit, quantitative character and applicability range, which are the result of new or better excitation sources, detectors, instrument design, automation, computer software and theoretical developments.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00473177
|
|
|
“Energy-dispersive X-ray fluorescence in geochemical mapping”. Civici N, Van Grieken R, X-ray spectrometry 26, 147 (1997). http://doi.org/10.1002/(SICI)1097-4539(199707)26:4<147::AID-XRS193>3.0.CO;2-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199707)26:4<147::AID-XRS193>3.0.CO;2-X
|
|
|
“Energy-dispersive X-ray fluorescence for trace metals analysis of water”. Vanderborght B, Van Grieken R page 1 (1975).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Energy-dispersive X-ray fluorescence for direct trace analysis of biomedical and environmental samples”. Van Grieken R, Robberecht H, Shani J, Van Dyck P, Vos L page 159 (1982).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Energy-dispersive X-ray fluorescence analysis of geological materials in borax beads using Tertian's binary coefficient approach combined with internal standard addition”. Muia LM, Van Grieken R, X-ray spectrometry 20, 179 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Endolithic cyanobacteria in Maastricht limestone”. Saiz-Jimenez C, Garcia-Rowe J, Garcia Del Cura MA, Ortega-Camvo JJ, Roekens E, Van Grieken R, The science of the total environment 94, 209 (1990). http://doi.org/10.1016/0048-9697(90)90171-P
Abstract: The Maastricht limestone used for the construction of the 14th century O.L. Basilica in Tongeren, Belgium, is a light yellowish, porous, soft rock of the Late Cretaceous age. The limestone has a high carbonate content (> 95%); quartz and glauconite occur rarely. On the north side of the building, there is extensive growth of epilithic algae. On the south side, an assemblage of organisms was observed beneath the abiotic surface. This community, developed as a green layer 1 mm below the surface, is dominated by cyanobacteria. A moss was also present. The organisms were studied by transmitted light, phase contrast and scanning electron microscopy, and isolated in cultures. The cyanobacteria belong to the genera Synechococcus and Chroococcidiopsis, and the moss was identified as Tortula muralis Hedw. The organic matter present in the green layer was characterized in terms of molecular components using analytical pyrolysis. Pyrolysis products from polysaccharides and proteins, and evaporation/pyrolysis products from lipids, comprise the vast majority of identified compounds. The identification of specific biomarkers such as 7-methylheptadecane is further evidence of the presence of cyanobacteria. Phytenes and phytadienes are indicative of phototrophic organisms, as they are pyrolysis products from chlorophylls.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90171-P
|
|
|
“Embedded ion exchange beads as standards for laser microprobe mass analysis of biological specimens”. Verbueken AH, Van Grieken RE, Paulus GJ, De Bruijn WC, Analytical chemistry 56, 1362 (1984). http://doi.org/10.1021/AC00272A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00272A036
|
|
|
“Elucidating the composition of atmospheric aerosols through the combined hierarchical, non-hierarchical and fuzzy clustering of large electron probe microanalysis data sets”. Treiger B, Bondarenko I, van Malderen H, Van Grieken R, Analytica chimica acta 317, 33 (1995). http://doi.org/10.1016/0003-2670(95)00405-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(95)00405-X
|
|
|
“Elemental x-ray images obtained by grazing-exit electron probe microanalysis (GE-EPMA)”. Tsuji K, Nullens R, Wagatsuma K, Van Grieken RE, Journal of analytical atomic spectrometry 14, 1711 (1999). http://doi.org/10.1039/A905301H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A905301H
|
|
|
“Elemental trace analysis of small samples by proton-induced X-ray-emission”. Johansson TB, Van Grieken RE, Nelson JW, Winchester JW, Analytical chemistry 47, 855 (1975). http://doi.org/10.1021/AC60356A035
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60356A035
|
|