|
Amelinckx S, van Dyck D, van Landuyt J, Van Tendeloo G (1997) Electron microscopy: principles and fundamentals. Vch, Weinheim
Keywords: ME1 Book as editor or co-editor; Electron microscopy for materials research (EMAT); Vision lab
|
|
|
“Electron microscopy, nanoscopy, and scanning micro- and nanoanalysis”. Oleshko VP, Gijbels R, Amelinckx S Wiley, Chichester, page 1 (2013).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Electron microscopy on nanoparticles: structure of C60 and C70 nanopraticles”. Pauwels B, Van Tendeloo G, Joutsensaari J, Kauppinen EI, (1999)
Keywords: P3 Proceeding; Electron microscopy for materials research (EMAT)
|
|
|
“Electron microscopy of interfaces in new materials”. Van Tendeloo G, Goessens C, Schryvers D, van Haverbergh J, de Veirman A, van Landuyt J s.l., page 200 (1991).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
Hu Z-Y (2016) Electron microscopy of hierarchically structured nanomaterials : linking structure to properties and synthesis. Antwerpen
Keywords: Doctoral thesis; Electron microscopy for materials research (EMAT)
|
|
|
“Electron microscopy of fullerenes and related materials”. Van Tendeloo G, Amelinckx S Wiley-VCH, Weinheim, page 353 (2000).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Electron microscopy of fullerenes and fullerene related structures”. Van Tendeloo G, van Landuyt J, Amelinckx S, , 498 (1994)
Keywords: P3 Proceeding; Electron microscopy for materials research (EMAT)
|
|
|
“Electron microscopy of C60 and C70 fullerites”. Van Tendeloo G, Amelinckx S Springer, Berlin, page 182 (1993).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Electron microscopy and scanning microanalysis”. Oleshko V, Gijbels R, Amelinckx S Wiley, Chichester, page 9088 (2000).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Electron microscopic study of long period ordering in complex oxides”. Amelinckx S, Nistor LC, Van Tendeloo G s.l., page 1 (1994).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Electron microprobe observations of recrystallization affecting PIXE-analysis of marine aerosol deposits”. Storms H, Van Dyck P, Van Grieken R, Maenhaut W, Journal of trace and microprobe techniques 2, 103 (1985)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Electron microprobe characterization of individual aerosol particles collected by aircraft above the Southern Bight of the North Sea”. Rojas CM, Van Grieken RE, Atmospheric environment : an international journal 26a, 1231 (1992). http://doi.org/10.1016/0960-1686(92)90384-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(92)90384-W
|
|
|
“Electron microprobe analysis of suspended matter in the Angola Basin”. Bernard P, Eisma D, Van Grieken R, Journal of sea research 41, 19 (1999). http://doi.org/10.1016/S1385-1101(98)00043-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1385-1101(98)00043-4
|
|
|
“Electron energy-loss spectroscopy and its application to individual particle analysis”. Xhoffer C, Jacob W, Van Grieken R, Broekaert JAC, Buseck P, (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Lu Y (2013) Electron energy-loss spectroscopy (EELS) characterization of diamond and related materials. Antwerpen
Keywords: Doctoral thesis; Electron microscopy for materials research (EMAT)
|
|
|
Guzzinati G, Das PP, Zompra A A., Nicopoulos S, Verbeeck J (2020) Electron energy loss spectra of several organic compounds
Abstract: We placed crystals of different compounds to explore the possibility of fingerprinting them through EELS. Here are representative datasets of 7 different compounds: b-cyclodextrin hexacarboxy cyclohexane tannin TH-15 peptide TH-27 peptide two different forms of piroxicam The datasets were collected at EMAT, using a monochromated FEI Titan3 TEM, within the scope of an EUSMI request. More information as well as analysis methodologies adopted for the data are detailed in the paper: Das et al. “Reliable Characterization of Organic & Pharmaceutical Compounds with High Resolution Monochromated EEL Spectroscopy”, Polymers 2020, 12(7), 1434.
Keywords: Dataset; Electron microscopy for materials research (EMAT)
DOI: 10.5281/zenodo.3975761
|
|
|
“Electron diffraction and microscopy of single-walled carbon nanotube bundles”. Colomer J-F, Van Tendeloo G Kluwer, Boston, Mass., page 45 (2003).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Electron correlation effects in quantum dots”. Matulis A, Peeters FM, , 1875 (1995)
Keywords: P3 Proceeding; Condensed Matter Theory (CMT)
|
|
|
Guzzinati G, Ghielens W, Mahr C, Bé,ché, A, Rosenauer A, Calders T, Verbeeck J (2019) Electron Bessel beam diffraction patterns, line scan of Si/SiGe multilayer
Keywords: Dataset; ADReM Data Lab (ADReM); Electron microscopy for materials research (EMAT)
DOI: 10.5281/ZENODO.2566137
|
|
|
“Electromagnetic modeling and design of a novel class of complementary split‐ring resonators”. Martínez-Dueñas EJR, de Jong van Coevorden CM, Stukach OV, Panokin NV, Gielis J, Caratelli D, International journal of RF and microwave computer-aided engineering 29, e21582 (2019). http://doi.org/10.1002/MMCE.21582
Abstract: This research study reports the assessment of complementary split ring resonators based on Gielis transformation as basic elements for the design of high‐performance microwave components in printed technology. From the electromagnetic simulation of said structures, suitable equivalent circuit models are extracted and analyzed. Physical prototypes are fabricated and tested for design validation. The obtained results confirm that the adoption of supershaped geometries enables the synthesis of very compact scalable microwave filters.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1002/MMCE.21582
|
|
|
“Electromagnetic mathematical modeling of 3D supershaped dielectric lens antennas”. Mescia L, Bia P, Caratelli D, Chiapperino MA, Stukach O, Gielis J, Mathematical problems in engineering: theory, methods, and applications , 8130160 (2016). http://doi.org/10.1155/2016/8130160
Abstract: The electromagnetic analysis of a special class of 3D dielectric lens antennas is described in detail. This new class of lens antennas has a geometrical shape defined by the three-dimensional extension of Gielis formula. The analytical description of the lens shape allows the development of a dedicated semianalytical hybrid modeling approach based on geometrical tube tracing and physical optic. In order to increase the accuracy of the model, the multiple reflections occurring within the lens are also taken into account.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1155/2016/8130160
|
|
|
“Electromagnetic characterization of supershaped lens antennas for high-frequency applications”. Bia P, Caratelli D, Mescia L, Gielis J page 1679 (2013).
Keywords: H1 Book chapter; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
|
|
“Electrochemistry of intact versus degraded cephalosporin antibiotics facilitated by LC–MS analysis”. Sleegers N, van Nuijs ALN, van den Berg M, De Wael K, Analytical Chemistry 93, 2394 (2021). http://doi.org/10.1021/ACS.ANALCHEM.0C04286
Abstract: The electrochemical detection of cephalosporins is a promising approach for the monitoring of cephalosporin levels in process waters. However, this class of antibiotics, like penicillins, is composed of chemically active molecules and susceptible to hydrolysis and aminolysis of the four membered β-lactam ring present. In order to develop a smart monitoring strategy for cephalosporins, the influence of degradation (hydrolysis and aminolysis) on the electrochemical fingerprint has to be taken into account. Therefore, an investigation was carried out to understand the changes of the voltammetric fingerprints upon acidic and alkaline degradation. Changes in fingerprints were correlated to the degradation pathways through the combination of square wave voltammetry and liquid chromatography quadrupole time-of-flight analysis. The characteristic electrochemical signals of the β-lactam ring disappeared upon hydrolysis. Additional oxidation signals that appeared after degradation were elucidated and linked to different degradation products, and therefore, enrich the voltammetric fingerprints with information of the state of the cephalosporins. The applicability of the electrochemical monitoring system was explored by the analysis of the intact and degraded industrial process waters containing the key intermediate 7-aminodeacetoxycephalosporanic acid (7-ADCA). Clearly, the intact process samples exhibited the expected core signals of 7-ADCA and could be quantified, while the degraded samples only showed the newly formed degradation products.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 6.32
DOI: 10.1021/ACS.ANALCHEM.0C04286
|
|
|
Schram J (2024) Electrochemical sensing strategies for multiple illicit drugs. 290 p
Abstract: Today, illicit drugs are omnipresent in society. Clandestine markets are growing faster than ever before, record amounts of cocaine are seized in seaports and airports, while the associated violence is spiralling out of control. In addition, drug monitoring centres worldwide are warning for the increasing complexity of the drug markets, as the traditionally popular drugs are joined by countless new synthetic variants, while medical drugs are also increasingly being abused. In order to provide services confronted with illicit drug samples (police, customs, forensic scientists, first responders, …) with important information on the identity of an unknown sample, suitable analytical tests are required. While these exist for laboratory environments, on-site applicable tests are important to accelerate the decision-making process. Electrochemical sensors have all the advantages required for such on-site tests: they are fast, portable, easy-to-use and reliable. Furthermore, they are not influenced by colours, which are frequently added to drug samples to deceive the existing tests. Previous work has mainly focussed on the detection of a single drug per analysis. However, many drugs could be encountered due to the diversity of the drug markets. Therefore, this project developed electrochemical strategies for the detection of multiple drugs simultaneously. First, the electrochemical behaviour of the individual drugs was studied in different measuring conditions (assessing the influence of pH, concentration and temperature). Then, all findings and strategies were combined to detect multiple targets simultaneously. An electrochemical sensor was developed for the four most popular drugs at music festivals: cocaine, MDMA, amphetamine and ketamine. This sensor generates a so-called ‘superfingerprint’ of the sample, which is then automatically interpreted by a developed algorithm in order to produce a straightforward output. Finally, a pill analysis sensor was developed in the context of drug checking services, where a consumer can anonymously have a sample chemically analysed to obtain information on the composition, dose and potentially harmful additives. The sensor achieved an outstanding accuracy in identifying the main component and provided the option to quantify, as well as an indication on the presence of other substances in the sample. The project’s findings demonstrate the potential for electrochemistry in illicit drug detection and provide a basis for the development of new sensors, targeting other drug combinations.
Keywords: Doctoral thesis; Pharmacology. Therapy; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
|
|
|
“Electrochemical sensing of amphetamine-type stimulants (pre)-precursors to fight against the illicit production of synthetic drugs”. Montiel FN, Parrilla M, Sleegers N, Van Durme F, van Nuijs ALN, De Wael K, Electrochimica acta 436, 141446 (2022). http://doi.org/10.1016/J.ELECTACTA.2022.141446
Abstract: The illicit drug precursor market for the manufacture of amphetamine-type stimulants (ATS), mainly amphetamine, methamphetamine and methylenedioxymethamphetamine (MDMA), has emerged quickly in the last years. The evidence of a more complex and sophisticated drug market underlines the pressing need for new on-site methods to quickly detect precursors of synthetic drugs, with electrochemical analysis as a promising technique. Herein, the electrochemical fingerprints of ten common ATS precursors-3-oxo-2-phenylbutanenitrile (APAAN), 3-oxo-2-phenylbutanamide (APAA), methyl 3-oxo-2-phenylbutanoate (MAPA), benzyl methyl ketone (BMK), 1-(1,3-benzodioxol-5-yl)propan-2-one (PMK), ephedrine, pseudoephedrine, safrole, sassafras oil and piperonal- are reported for the first time. The electrochemical screening disclosed the redox inactivity of BMK, which is an essential starting material for the production of ATS. Therefore, the local derivatization of BMK at an electrode surface by reductive amination is presented as a feasible solution to enrich its electrochemical fingerprint. To prove that, the resulting mixture was analyzed using a set of chromatographic techniques to understand the reaction mechanism and to identify possible electrochemical active products. Two reaction products (i.e. methamphetamine and 1-phenylpropan-2-ol) were found and characterized using mass spectrometry and electrochemical methods. Subsequently, the optimization of the reaction parameters was carefully addressed to set the portable electrochemical sensing strategy. Ultimately, the analysis concept was validated for the qualitative identification of ATS precursors in seizures from a forensic institute. Overall, the electrochemical approach demonstrates to be a useful and affordable analytical tool for the early identification of ATS precursors to prevent trafficking and drug manufacture in clandestine laboratories.
Keywords: A1 Journal article; Engineering sciences. Technology; Toxicological Centre; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.ELECTACTA.2022.141446
|
|
|
“Electrochemical rapid detection of methamphetamine from confiscated samples using a graphene-based printed platform”. Truta F, Drăgan A-M, Tertis M, Parrilla M, Slosse A, Van Durme F, De Wael K, Cristea C, Sensors 23, 6193 (2023). http://doi.org/10.3390/S23136193
Abstract: Methamphetamine (MAP) is a highly addictive and illegal stimulant drug that has a significant impact on the central nervous system. Its detection in biological and street samples is crucial for various organizations involved in forensic medicine, anti-drug efforts, and clinical diagnosis. In recent years, nanotechnology and nanomaterials have played a significant role in the development of analytical sensors for MAP detection. In this study, a fast, simple, and cost-effective electrochemical sensor is presented that is used for the sensitive detection of MAP in confiscated street samples with a complex matrix. The optimized screen-printed sensor based on a carbon working electrode modified with graphene demonstrated an excellent limit of detection, good sensitivity, and a wide dynamic range (1–500 μM) for the target illicit drug both for standard solutions and real samples (seized samples, tap water, and wastewater samples). It can detect MAP at concentrations as low as 300 nM in real samples. This limit of detection is suitable for the rapid preliminary screening of suspicious samples in customs, ports, airports, and on the street. Furthermore, the sensor exhibits a good recovery rate, indicating its reliability and repeatability. This quality is crucial for ensuring consistent and accurate results during screening processes.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.3390/S23136193
|
|
|
“Electrochemical profiling and liquid chromatography–mass spectrometry characterization of synthetic cathinones : from methodology to detection in forensic samples”. Schram J, Parrilla M, Sleegers N, Van Durme F, van den Berg J, van Nuijs ALN, De Wael K, Drug Testing And Analysis 13, 1282 (2021). http://doi.org/10.1002/DTA.3018
Abstract: The emergence of new psychoactive drugs in the market demands rapid and accurate tools for the on‐site classification of illegal and legal compounds with similar structures. Herein, a novel method for the classification of synthetic cathinones (SC) is presented based on their electrochemical profile. First, the electrochemical profile of five common SC (i.e., mephedrone, ethcathinone, methylone, butylone and 4‐chloro‐alpha‐pyrrolidinovalerophenone) is collected to build calibration curves using square wave voltammetry on graphite screen‐printed electrodes (SPE). Second, the elucidation of the oxidation pathways, obtained by liquid chromatography‐high resolution mass spectrometry, allows the pairing of the oxidation products to the SC electrochemical profile, providing a selective and robust classification. Additionally, the effect of common adulterants and illicit drugs on the electrochemical profile of the SC is explored. Interestingly, a cathodic pretreatment of the SPE allows the selective detection of each SC in presence of electroactive adulterants. Finally, the electrochemical approach is validated with gas‐chromatography‐mass spectrometry by analyzing 26 confiscated samples from seizures and illegal webshops. Overall, the electrochemical method exhibits a successful classification of SC including structural derivatives, a crucial attribute in an ever‐diversifying drug market.
Keywords: A1 Journal article; Pharmacology. Therapy; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 3.469
DOI: 10.1002/DTA.3018
|
|
|
“Electrochemical methods for on-site multidrug detection at festivals”. Van Echelpoel R, Schram J, Parrilla M, Daems D, Slosse A, Van Durme F, De Wael K, Sensors &, Diagnostics 1, 793 (2022). http://doi.org/10.1039/D2SD00043A
Abstract: Two electrochemical methodologies, i.e. flowchart and dual-sensor, were developed to aid law enforcement present at festivals to obtain a rapid indication of the presence of four illicit drugs in suspicious samples encountered.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1039/D2SD00043A
|
|
|
“Electrochemical in situ pH control enables chemical-free full urine nitrification with concomitant nitrate extraction”. De Paepe J, Clauwaert P, Gritti MC, Ganigue R, Sas B, Vlaeminck SE, Rabaey K, Environmental Science &, Technology 55, 8287 (2021). http://doi.org/10.1021/ACS.EST.1C00041
Abstract: Urine is a valuable resource for nutrient recovery. Stabilization is, however, recommended to prevent urea hydrolysis and the associated risk for ammonia volatilization, uncontrolled precipitation, and malodor. This can be achieved by alkalinization and subsequent biological conversion of urea and ammonia into nitrate (nitrification) and organics into CO2. Yet, without pH control, the extent of nitrification is limited as a result of insufficient alkalinity. This study explored the feasibility of an integrated electrochemical cell to obtain on-demand hydroxide production through water reduction at the cathode, compensating for the acidification caused by nitritation, thereby enabling full nitrification. To deal with the inherent variability of the urine influent composition and bioprocess, the electrochemical cell was steered via a controller, modulating the current based on the pH in the bioreactor. This provided a reliable and innovative alternative to base addition, enabling full nitrification while avoiding the use of chemicals, the logistics associated with base storage and dosing, and the associated increase in salinity. Moreover, the electrochemical cell could be used as an in situ extraction and concentration technology, yielding an acidic concentrated nitrate-rich stream. The make-up of the end product could be tailored by tweaking the process configuration, offering versatility for applications on Earth and in space.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
Impact Factor: 6.198
DOI: 10.1021/ACS.EST.1C00041
|
|
|
“Electrochemical identification of hazardous phenols and their complex mixtures in real samples using unmodified screen-printed electrodes”. Barich H, Cánovas R, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 904, 115878 (2022). http://doi.org/10.1016/J.JELECHEM.2021.115878
Abstract: The electrochemical behavior of some of the most relevant endocrine-disrupting phenols using unmodified carbon screen-printed electrodes (SPEs) is described for the first time. Experiments were made to assess the electrochemical behavior of phenol (PHOH), pentachlorophenol (PCP), 4-tert octylphenol (OP) and bisphenol A (BPA) and their determination in the most favorable conditions, using voltammetric methods such as cyclic voltammetry (CV), linear sweep voltammetry (LSV) and square wave voltammetry (SWV) in Britton Robinson (BR) buffer. Further, the usefulness of the electrochemical approach was validated with real samples from a local river and was compared to commercial phenols test kit, which is commonly used for on-site screening in industrial streams and wastewaters. Finally, the approach was compared with a lab-bench standard method using real samples, i.e., high-performance liquid chromatography with a photodiode array detector (HPLC-DAD).
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.5
DOI: 10.1016/J.JELECHEM.2021.115878
|
|