|
Buczyń,ska AJ (2014) Analytical methodology for combined stable carbon isotope ratio and concentration measurement of polycyclic aromatic hydrocarbons in air particulate matter. 186 p
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analytical electron microscopy of single particles”. Markowicz A, Raeymaekers B, Van Grieken R, Adams F page 173 (1986).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks”. Margui E, Hidalgo M, Queralt I, van Meel K, Fontas C, Spectrochimica acta: part B : atomic spectroscopy 67, 17 (2012). http://doi.org/10.1016/J.SAB.2011.12.004
Abstract: We aimed to achieve improved instrumental sensitivity and detection limits for the analysis of several elements (Cu, Ni, Zn, Pb and Cd) in aqueous samples with energy dispersive X-ray fluorescence spectrometry (EDXRF). The metals were pre-concentrated from aqueous solutions using commercially available organic-based solid-phase extraction (SPE) disks functionalized with iminodiacetate groups. These thin-layer organic materials provide an ideal support for XRF analysis. The elements were collected on the SPE extraction disks using a simple filtration procedure (starting with 1 L of aqueous sample) that allows direct XRF measurements to be performed in the field (in situ). We evaluated the analytical possibilities and drawbacks of using this pre-concentration procedure in combination with the following XRF configurations: a handheld unit, a benchtop EDXRF system and a high-energy polarized-beam EDXRF instrument (HE-P-EDXRF). Using the HE-P-EDXRF system, the detection limits for all metals were more than one order of magnitude lower than those attained using handheld and benchtop EDXRF instrumentation. For the detection of metal concentrations higher than similar to 20 mu g/L, however, handheld or benchtop systems remain a very good option due to their extreme simplicity of operation and low-cost, compact design. We demonstrate the application of these methodologies, using the three equipment systems, to the analysis of trace concentrations of metals in different types of aqueous samples, including tap water and waste water. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2011.12.004
|
|
|
“Analysis of X-ray spectra excited by X rays, electrons, and protons in monazite”. Annegarn HJ, Madiba CCP, Sellschop JPF, Genz H, Hoffmann DHH, Low W, Richter A, Van Grieken RE, Physical review : C : nuclear physics 16, 379 (1977). http://doi.org/10.1103/PHYSREVC.16.379
Abstract: Mineral monazite from Malaysia has been investigated by energy dispersive x-ray analysis employing three different methods: x-ray, relativistic electron and proton induced excitation. An upper limit of 15 ppm has been placed on the possible concentration of the superheavy element with Z=126.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1103/PHYSREVC.16.379
|
|
|
“Analysis of X-ray spectra by iterative least squares (AXIL): new developments”. Vekemans B, Janssens K, Vincze L, Adams F, van Espen P, X-ray spectrometry 23, 278 (1994). http://doi.org/10.1002/XRS.1300230609
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300230609
|
|
|
“Analysis of the composition of glass objects from Qumran, Israel and the comparison with other Roman glass from western Europe”. Aerts A, Janssens K, Velde B, Adams F, Wouters H page 113 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of speleothems by electron and X-ray microprobes”. Kuczumow A, Vekemans B, Schalm O, Gysels K, Ro C-U, Van Grieken R, Journal of analytical atomic spectrometry 16, 90 (2001). http://doi.org/10.1039/B007725I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B007725I
|
|
|
“Analysis of rain water by differential-pulse stripping voltammetry in nitric acid medium”. Komy Z, Roekens E, Van Grieken R, Analytica chimica acta 204, 179 (1988). http://doi.org/10.1016/S0003-2670(00)86357-6
Abstract: Differential-pulse anodic stripping voltammetry is applied to determine cadmium, lead and copper in rain water acidified with nitric acid to pH 1.5, and zinc after partial neutralization to pH 4.5. Subsequently, cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The effects of pH on the stripping peaks for Zn, Cd, Pb and Cu and of chloride on the stripping peak of copper are reported. Good agreement is found with d.p.s.v. determinations in hydrochloric acid medium and with a.a.s. measurements in most cases. Excellent accuracy is demonstrated; the average relative standard deviation per measurement appears to be between 12 and 22% for the overall analytical procedure for concentrations of 0.1550 μgl−1 of the various metals in the samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)86357-6
|
|
|
“Analysis of nonconducting materials by dc glow discharge spectrometry”. Bogaerts A, Schelles W, van Grieken R Wiley, Chichester, page 293 (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of micro computed tomography images, a look inside historic enamelled metal objects”. van der Linden V, Van de Casteele E, Thomas MS, de Vos A, Janssen E, Janssens K, Applied physics A : materials science &, processing 98, 385 (2010). http://doi.org/10.1007/S00339-009-5394-9
Abstract: In this study the usefulness of micro-Computed Tomography (µ-CT) for the in-depth analysis of enamelled metal objects was tested. Usually investigations of enamelled metal artefacts are restricted to non-destructive surface analysis or analysis of cross sections after destructive sampling. Radiography, a commonly used technique in the field of cultural heritage studies, is limited to providing two-dimensional information about a three-dimensional object (Lang and Middleton, Radiography of Cultural Material, pp. 6061, Elsevier-Butterworth-Heinemann, Amsterdam-Stoneham-London, 2005). Obtaining virtual slices and information about the internal structure of these objects was made possible by CT analysis. With this technique the underlying metal work was studied without removing the decorative enamel layer. Moreover visible defects such as cracks were measured in both width and depth and as of yet invisible defects and weaker areas are visualised. All these features are of great interest to restorers and conservators as they allow a view inside these objects without so much as touching them.
Keywords: A1 Journal article; Vision lab; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.455
Times cited: 3
DOI: 10.1007/S00339-009-5394-9
|
|
|
“Analysis of Malagasy medical herbs by X-ray fluorescence in total reflectivity”. Razafindramisa FL, Andriambololona R, Brunel M, Van Grieken RE, Journal de physique: 4 6, 833 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of lateritic material from Cerro impacto by instrumental neutron activation employing a low-energy photon semiconductor and a high-energy Ge(Li) detector”. LaBrecque JJ, Beusen JM, Van Grieken RE, Applied spectroscopy 40, 140 (1986). http://doi.org/10.1366/0003702864509600
Abstract: Nineteen elements were determined in four different grain size fractions of a bulk geological material from Cerro Impacto for a study of the physical (mechanical) concentration process of different elements based upon the hardness of the different minerals. The analysis was performed by excitation of the sample with a high, slow neutron flux followed by gamma-ray spectroscopy with both a conventional Ge(Li) high-energy detector and a low-energy photon detector (LEPD). The accuracy of this method was studied with the use of two standard reference materials, SY-2 and SY-3, which are similar to the real samples. The values determined were also compared with a secondary target x-ray fluorescence method for all the elements that were suitable to both methods. Actually, the x-ray fluorescence method was found to be more complementary than competitive.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/0003702864509600
|
|
|
“Analysis of indoor gaseous formic and acetic acid, using radial diffusive samplers”. Stranger M, Potgieter-Vermaak S, Sacco P, Quaglio F, Pagani D, Cocheo C, Godoi AFL, Van Grieken R, Environmental monitoring and assessment 149, 411 (2009). http://doi.org/10.1007/S10661-008-0217-6
Abstract: A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 ìg m−3 and 1248 ìg m−3 were determined to be 91.2 ± 3.9 ml min−1 and 111.6 ± 2.8 ml min−1, respectively. The acetic acid sampling rate was independent of the concentration in the range 160 ìg m−31564 ìg m−3, and amounted to 97.3 ± 3.1 ml min−1. Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 321% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 ± 0.07 ìg for formic acid and 1.21 ± 0.14 ìg for acetic acid, and detection limits lower than 0.5 ìg m−3 could be achieved, which is an improvement of 9899% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10661-008-0217-6
|
|
|
“Analysis of individual microscopic particles by means of synchrotron radiation induced X-ray micro fluorescence”. Janssens K, Adams F, Rivers ML, Jones KW, Proceedings 27th MAS (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of individual environmental particles using ultra-thin window EPXMA”. Ro C-U, Osán J, Van Grieken R, (1998)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of individual aerosol particles in Siberian region: provisional results”. van Malderen H, Van Grieken R, Khodzher TV, Bufetov NS, Koutsenogii KP, Atmospheric and oceanic optics 7, 622 (1994)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of heterogeneous CaCO3-CaSO4 single particles using ultra-thin window EPMA”. Ro C-U, Oh K-Y, Van Grieken RE, (2000)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of geothermal waters by spark source mass spectrometry”. Vandelannoote R, Blommaert W, Gijbels R, van Grieken R, Fresenius' Zeitschrift für analytische Chemie 309, 291 (1981). http://doi.org/10.1007/BF00488604
Abstract: Although the analysis of thermal water by spark-source mass spectrometry (SSMS) is rather timeconsuming, it allows the detection of about 20 elements of geochemical interest down to the ppb-level. A physical preconcentration is proposed in order to collect elements having quite different chemical properties, e.g. alkalis, transition elements, and elements occurring in anionic form. The relative sensitivity factors appear to be rather independent of the salt content of the graphite electrodes. Contrary to neutron activation analysis, SSMS has a quite uniform elemental sensitivity, and allows to determine elements for which neutron activation is not suitable, e.g. Sn and Pb. The precision of SSMS is however by a factor of about 2 worse than that obtained for neutron activation.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 8
DOI: 10.1007/BF00488604
|
|
|
“Analysis of façon-de-Venise glass originating from Central and Western Europe”. Šmit Ž, Janssens K, Schalm O, Kos M page 165 (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of composite structure and primordial wood remains in petrified wood”. Nowak J, Nowak D, Chevallier P, Lekki J, Van Grieken R, Kuczumov A, Applied spectrsocopy 61, 889 (2007). http://doi.org/10.1366/000370207781540141
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/000370207781540141
|
|
|
“Analysis of biological materials from Tanzania by total reflection X-ray fluorescence (TXRF) analysis”. Koleleni YIA, Van Grieken R, Tanzania journal of science 16, 143 (1990)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analyses of petrified wood by electron, X-ray and optical microprobes”. Kuczumov A, Vekemans B, Schalm O, Dorriné, W, Chevallier P, Dillmann P, Ro C-U, Janssens K, Van Grieken R, Journal of analytical atomic spectroscopy 14, 435 (1999). http://doi.org/10.1039/A806748A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A806748A
|
|
|
Van Grieken R (1973) Analyse van ferro-metalen door activering met 14 MeV neutronen. 128 p
Keywords: MA3 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analiza pierwiastkowa zabytkowych obiektów szklanych”. Wagner B, Nowak A, Bulska E, Kunicki-Goldfinger J, Schalm O, Janssens K, Nauka i Zabytki , 71 (2008)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analisis cuantitativo sin estandares de particulas individuales mediante microsonda de electrones”. Trincavelli JC, Van Grieken R page 273 (1996).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analise de solos por meio de fluorescencia de raios-X nao-dispersiva”. Costa Dantas C, Da Silveira Dantas H, Van 't dack L, Van Grieken R, Química nova 4, 110 (1981)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“An overview of wet deposition of micropollutants to the North Sea”. Struyf H, Van Grieken R, Atmospheric environment: part A : general topics 27, 2669 (1993). http://doi.org/10.1016/0960-1686(93)90036-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(93)90036-X
|
|
|
“An N-myristoylated globin with a redox-sensing function that regulates the defecation cycle in Caenorhabditis elegans”. Tilleman L, De Henau S, Pauwels M, Nagy N, Pintelon I, Braeckman BP, De Wael K, Van Doorslaer S, Adriaensen D, Timmermans J-P, Moens L, Dewilde S, PLoS ONE 7, e48768 (2012). http://doi.org/10.1371/JOURNAL.PONE.0048768
Abstract: Globins occur in all kingdoms of life where they fulfill a wide variety of functions. In the past they used to be primarily characterized as oxygen transport/storage proteins, but since the discovery of new members of the globin family like neuroglobin and cytoglobin, more diverse and complex functions have been assigned to this heterogeneous family. Here we propose a function for a membrane-bound globin of C. elegans, GLB-26. This globin was predicted to be myristoylated at its N-terminus, a post-translational modification only recently described in the globin family. In vivo, this globin is found in the membrane of the head mesodermal cell and in the tail stomato-intestinal and anal depressor muscle cells. Since GLB-26 is almost directly oxidized when exposed to oxygen, we postulate a possible function as electron transfer protein. Phenotypical studies show that GLB-26 takes part in regulating the length of the defecation cycle in C. elegans under oxidative stress conditions.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.806
Times cited: 6
DOI: 10.1371/JOURNAL.PONE.0048768
|
|
|
“An intrusive portrait by Goya”. Bull D, Krekeler A, Alfeld M, Dik J, Janssens K, The Burlington magazine 153, 668 (2011)
Keywords: A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“An improved electrochemical aptasensor for chloramphenicol detection based on aptamer incorporated gelatine”. Hamidi-Asl E, Dardenne F, Blust R, De Wael K, Sensors 15, 7605 (2015). http://doi.org/10.3390/S150407605
Abstract: Because of the biocompatible properties of gelatine and the good affinity of aptamers for their targets, the combination of aptamer and gelatine type B is reported as promising for the development of biosensing devices. Here, an aptamer for chloramphenicol (CAP) is mixed with different types of gelatine and dropped on the surface of disposable gold screen printed electrodes. The signal of the CAP reduction is investigated using differential pulse voltammetry. The diagnostic performance of the sensor is described and a detection limit of 1.83 x 10(-10) M is found. The selectivity and the stability of the aptasensor are studied and compared to those of other CAP sensors described in literature.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.677
Times cited: 21
DOI: 10.3390/S150407605
|
|