“Performance and characteristics of two total-reflection X-ray fluorescence and a particle induced X-ray emission setup for aerosol analysis”. Injuk J, Van Grieken R, Klockenkämper R, von Bohlen A, Kump P, Spectrochimica acta: part B : atomic spectroscopy 52, 977 (1997). http://doi.org/10.1016/S0584-8547(97)00028-1
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(97)00028-1
|
“Plasma diagnostics of an analytical Grimm-type glow discharge in argon and in neon: Langmuir probe and optical emission spectroscopy measurements”. Bogaerts A, Quentmeier A, Jakubowski N, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 50, 1337 (1995). http://doi.org/10.1016/0584-8547(95)01356-5
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.176
Times cited: 37
DOI: 10.1016/0584-8547(95)01356-5
|
“Polarized-beam high-energy EDXRF in geological samples”. Čevik U, Akbulut S, Makarovska Y, Van Grieken R, Spectroscopy letters 46, 36 (2013). http://doi.org/10.1080/00387010.2012.661015
Abstract: Certified reference materials (NIST 1645, BCR 143, IAEA 7, BCR 141, NIESCRM02, and IAEA 375) were used for determining the performance of a secondary target energy-dispersive X-ray fluorescence (EDXRF) spectrometer, Epsilon 5 (PANalytical, Almelo, the Netherlands). For the evaluation of the EDXRF spectra with polarized-beam high-energy excitation, the WinAxil software package has been applied. The results showed that Epsilon 5, EDXRF spectrometry is favorable for the determination of elemental concentrations in geological samples, but the sample preparation has the largest influence on the precision. However, they presented good agreement with certified values for most of the elements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/00387010.2012.661015
|
“Possibilities and limitations of synchrotron X-ray powder diffraction with double crystal and double multilayer monochromators for microscopic speciation studies”. de Nolf W, Jaroszewicz J, Terzano R, Lind OC, Salbu B, Vekemans B, Janssens K, Falkenberg G, Spectrochimica acta: part B : atomic spectroscopy 64, 775 (2009). http://doi.org/10.1016/J.SAB.2009.06.003
Abstract: The performance of a combined microbeam X-ray fluorescence/X-ray powder diffraction (XRF/XRPD) measurement station at Hamburger Synchrotronstrahlungslabor (HASYLAB) Beamline L is discussed in comparison to that at European Synchrotron Radiation Facility (ESRF) ID18F/ID22. The angular resolution in the X-ray diffractograms is documented when different combinations of X-ray source, optics and X-ray diffraction detectors are employed. Typical angular resolution values in the range 0.30.5° are obtained at the bending magnet source when a pink beam form of excitation is employed. A similar setup at European Synchrotron Radiation Facility beamlines ID18F and ID22 allows to reach angular resolution values of 0.10.15°. In order to document the possibilities and limitations for speciation of metals in environmental materials by means of Hamburger Synchrotronstrahlungslabor Beamline L X-ray fluorescence/X-ray powder diffraction setup, two case studies are discussed, one involved in the identification of the crystal phases in which heavy metals such as chromium, iron, barium and lead are present in polluted soils of an industrial site (Val Basento, Italy) and another involved in the speciation of uranium in depleted uranium particles (Ceja Mountains, Kosovo). In the former case, the angular resolution is sufficient to allow identification of most crystalline phases present while in the latter case, it is necessary to dispose of an angular resolution of ca. 0.2° to distinguish between different forms of oxidized uranium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2009.06.003
|
“Preconcentration methods for the analysis of liquid samples by X-ray fluorescence techniques”. Marguí, E, Van Grieken R, Fontàs C, Hidalgo M, Queralt I, Applied spectroscopy reviews 45, 179 (2010). http://doi.org/10.1080/05704920903584198
Abstract: This article gives an overview of the state-of-the-art of multi-element and single-element preconcentration procedures prior to X-ray fluorescence (XRF) analysis of liquid samples. Many of these preconcentration methods were developed long ago and the purpose of this review is to present some new efficient variations of these methods and new techniques extending the possibilities of XRF for liquid solutions analysis. In addition, trends and future perspectives in this domain are also commented on and discussed in the last section of the review.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/05704920903584198
|
“Preliminary evaluation of micro-Raman spectrometry for the characterization of individual aerosol particles”. Potgieter-Vermaak SS, Van Grieken R, Applied spectroscopy 60, 39 (2006). http://doi.org/10.1366/000370206775382848
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/000370206775382848
|
“Quantification in grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken RE, de Bokx PK, Urbach HP, Spectrochimica acta: part B : atomic spectroscopy 54, 1525 (1999). http://doi.org/10.1016/S0584-8547(99)00051-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00051-8
|
“Quantitative characterization of individual aerosol particles by thin-window electron probe microanalysis combined with iterative simulation”. Szalóki I, Osán J, Ro C-U, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 55, 1017 (2000). http://doi.org/10.1016/S0584-8547(00)00174-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(00)00174-9
|
“Raman spectroscopy for the analysis of coal : a review”. Potgieter-Vermaak S, Maledi N, Wagner N, van Heerden JHP, Van Grieken R, Potgieter JH, Journal of Raman spectroscopy 42, 123 (2011). http://doi.org/10.1002/JRS.2636
Abstract: The advances in the characterization of amorphous carbons by Raman spectroscopy over the last four decades are of interest to many industries, especially those involving the combustion, gasification and pyrolysis of coal. Many researchers report on the Raman character of the natural organic matter in carbon-containing compounds, such as coal, and relate the Raman bands to the structural order of the amorphous carbons. The basis of most of these studies evolved around the assignment of the G (graphitic, ∼1580 cm−1) band to crystalline graphite and any other bands, called D bands, (disorder, various from 1100 to 1500 cm−1) to any type of structural disorder in the graphitic structure. Concerning coal analysis, the information gained by Raman investigations has been used to describe char evolution as a function of temperature, the presence of catalysts and different gasification conditions. In addition, researchers looked at maturation, grade, doppleritization and many more aspects of interest. One aspect that has, however, not been addressed by most of the researchers is the natural inorganic matter (NIM) in the carbon-containing compounds. Micro-Raman spectroscopy (MRS) has many advantages over other characterization tools, i.e. in situ analysis, nondestructive, no sample preparation, low detection limit, micrometer-scale characterization, versatility and sensitivity to many amorphous compounds. With the distinct advantages it has over that of other molecular characterization tools, such as powder X-ray diffraction (PXRD), Fourier-transform infrared spectrometry (FT-IR) and scanning electron microscopy with X-ray detection (SEM/EDS), it is surprising that it has not yet been fully exploited up to this point for the characterization of the NIM in coal and other amorphous carbons. This paper reviews the work published on the Raman characterization of the natural organic matter (NOM) of coals and reports on preliminary results of the NIM character of various South African coals, whereby various inorganic compounds and minerals in the coal have been characterized.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/JRS.2636
|
“Raman study of different crystalline forms of PbCrO4 and PbCr1-xSxO4 solid solutions for the noninvasive identification of chrome yellows in paintings : a focus on works by Vincent van Gogh”. Monico L, Janssens K, Hendriks E, Brunetti BG, Miliani C, Journal of Raman spectroscopy 45, 1034 (2014). http://doi.org/10.1002/JRS.4548
Abstract: Chrome yellows, a class of pigments frequently used by painters of the Impressionism and Post-impressionism period, are known for their different chemical stability; the latter depends on the chemical composition (PbCrO4, PbCr1-xSxO4) and crystalline structure (monoclinic or orthorhombic) of the material. The possibility to distinguish among different forms of this pigment is therefore relevant in order to extend knowledge on the corresponding degradation process that is observed on several original paintings. For this purpose, three paintings conserved at the Van Gogh Museum (Amsterdam) were analyzed using noninvasive Raman spectroscopy, while equivalent investigations employing bench-top instrumentation were performed to obtain information from micro-samples originating from these works of art. In each painting, the chrome yellow was identified either as monoclinic PbCrO4 or in the form of monoclinic PbCr1-xSxO4 (x<0.25) or S-rich orthorhombic PbCr1-xSxO4 (x similar to 0.5). Our ability to make this fairly subtle distinction is based on a Raman study of several oil paint model samples made up of monoclinic and/or orthorhombic crystalline forms of PbCrO4 and PbCr1-xSxO4 (0.1x0.8). These paints were studied using several excitation wavelengths (namely 785.0, 532.0, 514.5, and 488nm). Because of the absence of the resonance Raman effect, which strongly enhances the chromate symmetric stretching band, and the absence of any laser-induced photodecomposition, it is advantageous to acquire data at 785.0nm. The band-shape and the position of the chromate bending modes proved to be more sensitive to the solid solution composition and crystalline structure than the stretching modes and can be used as distinctive spectral markers to discriminate among the different chrome yellow forms that are present. Copyright (c) 2014 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.969
Times cited: 34
DOI: 10.1002/JRS.4548
|
“Rapid lignin quantification for fungal wood pretreatment by ATR-FTIR spectroscopy”. Wittner N, Slezsák J, Broos W, Geerts J, Gergely S, Vlaeminck SE, Cornet I, Spectrochimica acta: part A: molecular and biomolecular spectroscopy , 121912 (2023). http://doi.org/10.1016/J.SAA.2022.121912
Abstract: Lignin determination in lignocellulose with the conventional two-step acid hydrolysis method is highly laborious and time-consuming. However, its quantification is crucial to monitor fungal pretreatment of wood, as the increase of acid-insoluble lignin (AIL) degradation linearly correlates with the achievable enzymatic saccharification yield. Therefore, in this study, a new attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy method was developed to track fungal delignification in an easy and rapid manner. Partial least square regression (PLSR) with cross-validation (CV) was applied to correlate the ATR-FTIR spectra with the AIL content (19.9%–27.1%). After variable selection and normalization, a PLSR model with a high coefficient of determination (
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL); Biochemical Wastewater Valorization & Engineering (BioWaVE)
Impact Factor: 4.4
DOI: 10.1016/J.SAA.2022.121912
|
“Spatially resolved micro-X-ray fluorescence and micro-X-ray absorption fine structure study of a fractured granite bore core following a radiotracer experiment”. Denecke MA, Brendebach B, de Nolf W, Falkenberg G, Janssens K, Simon R, Spectrochimica acta: part B : atomic spectroscopy 64, 791 (2009). http://doi.org/10.1016/J.SAB.2009.05.025
Abstract: Spatially resolved X-ray absorption and fluorescence investigation with a micrometer-scale resolution on actinide-containing samples provide information necessary for safety assessment of nuclear waste disposal. In this paper one example of such an experiment is presented. This example entails neptunium speciation in a fractured granite bore core from the Swedish Äspö Hard Rock Laboratory following a radiotracer experiment using µ-XAFS and µ-XRF. In order to probe micro-volumes below the surface in the granite samples and thereby avoid potential changes in the Np speciation during cutting of the bore core, a confocal irradiationdetection geometry is employed. µ-XAFS results for a selected granite bore core cross section with ~ 3 nmol Np/g reveal that Np, originally introduced as Np(V) in the tracer cocktail, is present in the granite in its reduced Np(IV) form. The Np(IV) is often present as particles, tens of µm in size. Elemental distribution maps show the tracer Np to be located in fissures and permeable channels not larger than 100 µm. The Np distribution appears often correlated with Zn also present in some fissures. We observe small granite fissures containing Fe (presumably Fe(II)), where we do not detect any Np. It is feasible that inflowing Np(V) has a shorter residence time in large fractures, while in the smaller fissures migration is slower, leading to longer residence times, i.e., reaction times, where it is reduced to less soluble Np(IV) and becomes thereby immobilized.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 21
DOI: 10.1016/J.SAB.2009.05.025
|
“Special issue: Proceedings of the 15th International Congress on X-ray Optics and Microanalysis”. Janssens K, Journal of analytical atomic spectroscopy 14, 357 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Spectroscopy and ion chromatography to study the effects of air pollution on historical buildings”. Van Grieken R, Roekens E, Sweevers H, Vleugels G, Spectroscopy 10, 70 (1989)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Study of a unique 16th century Antwerp majolica floor in the Rameyenhof castle's chapel by means of X-ray fluorescence and portable Raman analytical instrumentation”. Van de Voorde L, Vandevijvere M, Vekemans B, Van Pevenage J, Caen J, Vandenabeele P, van Espen P, Vincze L, Spectrochimica acta: part B : atomic spectroscopy 102, 28 (2014). http://doi.org/10.1016/J.SAB.2014.10.007
Abstract: The most unique and only known 16th century Antwerp majolica tile floor in Belgium is situated in a tower of the Rameyenhof castle (Gestel, Belgium). This exceptional work of art has recently been investigated in situ by using X-ray fluorescence (XRF) and Raman spectroscopy in order to study the material characteristics. This study reports on the result of the analyses based on the novel combination of non-destructive and portable instrumentation, including a handheld XRF spectrometer for obtaining elemental information and a mobile Raman spectrometer for retrieving structural and molecular information on the floor tiles in the Rameyenhof castle and on a second, similar medallion, which is stored in the Rubens House museum in Antwerp (Belgium). The investigated material, majolica, is a type of ceramic, which fascinated many people and potters throughout history by its beauty and colourful appearance. In this study the characteristic major/minor and trace element signature of 16th century Antwerp majolica is determined and the pigments used for the colourful paintings present on the floor are identified. Furthermore, based on the elemental fingerprint of the white glaze, and in particular on the presence of zinc in the tiles – an element that was not used for making 16th century majolica – valuable information about the originality of the chapel floor and the two central medallions is acquired. (C) 2014 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1016/J.SAB.2014.10.007
|
“Substrate selection for optimum qualitative and quantitative single atmospheric particles analysis using nano-manipulation, sequential thin-window electron probe X-ray microanalysis and micro-Raman spectrometry”. Godoi RHM, Potgieter-Vermaak S, de Hoog J, Kaegi R, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 61, 375 (2006). http://doi.org/10.1016/J.SAB.2006.02.004
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2006.02.004
|
“Substrates with a periodic surface structure in grazing-exit X-ray microanalysis”. Bekshaev A, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 57, 865 (2002). http://doi.org/10.1016/S0584-8547(02)00019-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(02)00019-8
|
“The anharmonic force field of thioformaldehyde, H2CS”. Martin JML, François JP, Gijbels R, Journal of molecular spectroscopy 168, 363 (1994)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.482
Times cited: 18
|
“The anharmonic-force field of thioformaldehyde, h2cs, by ab-initio methods”. Martin JML, Francois, Gijbels R, Journal of molecular spectroscopy 168, 363 (1994). http://doi.org/10.1006/jmsp.1994.1285
Abstract: The quartic force field of thioformaldehyde has been calculated ab initio using large basis sets and augmented coupled cluster methods. Calculated fundamentals are in excellent agreement with experiment, as is the most important Coriolis coupling constant. Computed values for the anharmonicity, rovibrational coupling, and centrifugal distortion constants of the four isotopomers (H2CS)-S-32, (H2CS)-S-34, (HDCS)-S-32, and (D2CS)-S-32 have been reported. Predictions have been made for all vibrational transitions from the ground state to excited states with at most two quanta for these isotopomers, both using second-order perturbation theory corrected for Darling-Dennison resonance and using vibrational SCF-CI calculations. For (D2CS)-S-32, perturbation theory performs quite well; for the other isotopomers, performance is poorer for states involving excitation of the out-of-plane bend and, for the (H2CS)-S-32 and (H2CS)-S-34 isotopomers, also for the antisymmetric bend that is in severe Coriolis resonance with it. A possible explanation has been suggested. (C) 1994 Academic Press, Inc.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.482
Times cited: 18
DOI: 10.1006/jmsp.1994.1285
|
“The influence of laser-particle interaction in laser induced breakdown spectroscopy and laser ablation inductively coupled plasma spectrometry”. Lindner H, Loper KH, Hahn DW, Niemax K, Spectrochimica acta: part B : atomic spectroscopy 66, 179 (2011). http://doi.org/10.1016/j.sab.2011.01.002
Abstract: Particles produced by previous laser shots may have significant influence on the analytical signal in laser-induced breakdown spectroscopy (LIBS) and laser ablation inductively coupled plasma (LA-ICP) spectrometry if they remain close to the position of laser sampling. The effects of these particles on the laser-induced breakdown event are demonstrated in several ways. LIBS-experiments were conducted in an ablation cell at atmospheric conditions in argon or air applying a dual-pulse arrangement with orthogonal pre-pulse, i.e., plasma breakdown in a gas generated by a focussed laser beam parallel and close to the sample surface followed by a delayed crossing laser pulse in orthogonal direction which actually ablates material from the sample and produces the LIBS plasma. The optical emission of the LIBS plasma as well as the absorption of the pre-pulse laser was measured. In the presence of particles in the focus of the pre-pulse laser, the plasma breakdown is affected and more energy of the pre-pulse laser is absorbed than without particles. As a result, the analyte line emission from the LIBS plasma of the second laser is enhanced. It is assumed that the enhancement is not only due to an increase of mass ablated by the second laser but also to better atomization and excitation conditions favored by a reduced gas density in the pre-pulse plasma. Higher laser pulse frequencies increase the probability of particle-laser interaction and, therefore, reduce the shot-to-shot line intensity variation as compared to lower particle loadings in the cell. Additional experiments using an aerosol chamber were performed to further quantify the laser absorption by the plasma in dependence on time both with and without the presence of particles. The overall implication of laser-particle interactions for LIBS and LA-ICP-MS/OES are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 12
DOI: 10.1016/j.sab.2011.01.002
|
“The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials”. Kempenaers L, Vincze L, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 55, 651 (2000). http://doi.org/10.1016/S0584-8547(00)00207-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00207-X
|
“Thermal stability of beam sensitive atmospheric aerosol particles in electron probe microanalysis at liquid nitrogen temperature”. Worobiec A, de Hoog J, Osán J, Szalóki I, Ro C-U, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 58, 479 (2003). http://doi.org/10.1016/S0584-8547(03)00013-2
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(03)00013-2
|
“Three-dimensional density profiles of sputtered atoms and ions in a direct current glow discharge: experimental study and comparison with calculations”. Bogaerts A, Wagner E, Smith BW, Winefordner JD, Pollmann D, Harrison WW, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 52, 205 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 46
|
“Three-dimensional density profiles of the argon metastable atoms in a direct current glow discharge: experimental study and comparison with calculations”. Bogaerts A, Guenard RD, Smith BW, Winefordner JD, Harrison WW, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 52, 219 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 36
|
“What modeling reveals about the properties of an inductively coupled plasma”. Bogaerts A, Aghaei M, Spectroscopy 31, 52 (2016)
Abstract: To get better performance from inductively coupled plasma (ICP)-based methods, it is informative to study the properties of the ICP under different conditions. Annemie Bogaerts and Maryam Aghaei at the University of Antwerp, Belgium, are using computational modeling to examine how various properties of the ICP, such as gas flow path lines and velocity, temperature changes, and ionization effects, are affected by numerous factors, such as the gas flow rates of injector and auxiliary gas, applied power, and even the very presence of a mass spectrometry (MS) sampler. They have also applied their models to study particle transport through the ICP. Using their developed model, it is now possible to predict optimum conditions for specific analyses. Bogaerts and Aghaei spoke to us about this work.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 0.466
|
“X-ray analysis of riverbank sediment of the Tisza (Hungary): identification of particles from a mine pollution event”. Osán J, Kurunczi S, Török S, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 57, 413 (2002). http://doi.org/10.1016/S0584-8547(01)00405-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00405-0
|