|
“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
|
|
“EXRS2022 : the 2022 edition of the European X-ray Spectrometry conference, held in Bruges, Belgium”. Janssens K, X-ray spectrometry 52, 276 (2023). http://doi.org/10.1002/XRS.3386
Keywords: Editorial; Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 1.2
DOI: 10.1002/XRS.3386
|
|
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
|
|
“Grazing-exit electron probe x-ray microanalysis of light elements in particles”. Spolnik Z, Tsuji K, Van Grieken R, X-ray spectrometry 33, 16 (2004). http://doi.org/10.1002/XRS.656
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.656
|
|
|
“Heavy metal analysis around Iskenderun Bay in Turkey”. Čevik U, Koz B, Makarovska Y, X-ray spectrometry 39, 202 (2010). http://doi.org/10.1002/XRS.1250
Abstract: The heavy metal analysis around Iskenderun Bay in Turkey was carried out using mosses, soils, mussels, and sediments. This region is one of the most industrial areas of Turkey, including iron-steel plants, beverage, liquefied petroleum gas (LPG) plants, and oil transfer docks. Energy dispersive X-ray fluorescence spectrometry (Epsilon 5, PANalytical, Almelo, The Netherlands) was used to analyze all samples. V, Cr, Mn, Fe, Ni, Cu, Zn, As, and Pb elements were observed in all samples studied. Although Ce was detected in some mosses and soils, Sn was detected only in some moss samples. Pb concentrations in the moss samples are higher than the soil, the mussel, and the sediment samples. This can be attributed to the mosses that absorb heavy metals such as Pb easily from the air. As the aim of this study was to analyze heavy metals, the evaluation of these elements with their potential hazards for ecology and humans is briefly discussed
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1250
|
|
|
“Heterogeneity effects in direct X-ray fluorescence analysis of hair”. Török S, Van Dyck P, Van Grieken R, X-ray spectrometry 13, 27 (1984). http://doi.org/10.1002/XRS.1300130106
Abstract: The methodology of direct hair analysis by energy-dispersive x-ray fluorescence was studied. The effect on the XRF result of having a non-homogeneous radial distribution of the analyte in a single hair strand and the macroscopic effects in a bundle of hairs were calculated to evaluate possible systematic errors. The detection limits were mapped as a function of the target thickness and surface fraction. It appeared that a 10 mg cm−2 sample thickness, i. e. a target with about four layers of hair strands, is recommended. The standard deviation of this simple direct analytical method is 619% for some important elements. Discrepancies with neutron activation analysis had a mean value of around 15%. About twelve elements can be determined simultaneously on a routine basis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300130106
|
|
|
“Heterogeneity effects in direct XRF analysis of traces of heavy metals preconcentrated on polyurethane foam sorbents”. Török S, Braun T, Van Dyck P, Van Grieken R, X-ray spectrometry 15, 7 (1986). http://doi.org/10.1002/XRS.1300150104
Abstract: Trace amounts of heavy metals were preconcentrated on discs of polyurethane (PU) foam loaded with ammonium diethyldithiocarbamate (DDTC), to increase the sensitivity of XRF. Since the diameter of the cavities in the open-cell PU foams reaches 30300 μm, considerable heterogeneity effects might occur, which could reduce the accuracy of the method. The possible systematic error introduced by considering the sample to be homogeneous is calculated using the Berry et al. model. The calculations show that the underestimation of the absorption correction factor when considering the sample as being homogeneous is less than 2% for high-Z elements when the sample thickness is at least 2 mm. The detection limits are also around the minima for this thickness.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150104
|
|
|
“High-energy polarized-beam EDXRF for trace metal analysis of vegetation samples in environmental studies”. Marguí, E, Padilla R, Hidalgo M, Queralt I, Van Grieken R, X-ray spectrometry 35, 169 (2006). http://doi.org/10.1002/XRS.890
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.890
|
|
|
“ID18F: a new micro-X-ray fluorescence end-station at the European Synchrotron Radiation Facility (ESRF): preliminary results”. Somogyi A, Drakopoulos M, Vincze L, Vekemans B, Camerani C, Janssens K, Snigirev A, Adams F, X-ray spectrometry 30, 242 (2001). http://doi.org/10.1002/XRS.494.ABS
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 76
DOI: 10.1002/XRS.494.ABS
|
|
|
“Individual particle characterization of Siberian aerosols by micro-PIXE and backscattering spectrometry”. van Malderen H, Hoornaert S, Injuk J, Przybylowicz WJ, Pineda CA, Prozesky VM, Van Grieken R, X-ray spectrometry 30, 320 (2001). http://doi.org/10.1002/XRS.505
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.505
|
|
|
“Influence of sample thickness, excitation energy and geometry on particle size effects in XRF”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 14, 183 (1985). http://doi.org/10.1002/XRS.1300140409
Abstract: Expressions are presented for calculating the matrix effect and the pure particle size effect in the XRF analysis of particulate samples with a discrete particle size. The equations are based on the absorption-weighted radiometric diameter concept. Two excitationdetection geometries are considered, with the angles between the sample plane and both the incident and emerging radiation being either 90° (π geometry) or 45° (π/2 geometry). Calculations were made for different sample loadings and exciting radiation energies. The influence of these parameters on the matrix and pure particle size effects is shown. From the results, it is possible to predict the performances of alternative experimental correction procedures for the particle size effect, involving dual measurements at different excitation energies or in different excitationdetection geometries.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300140409
|
|
|
“Interpreting technical evidence from spectral imaging of paintings by Edouard Manet in the Courtauld Gallery”. Amato SR, Burnstock A, Cross M, Janssens K, Rosi F, Cartechini L, Fontana R, Dal Fovo A, Paolantoni M, Grazia C, Romani A, Michelin A, Andraud C, Tournie A, Dik J, X-ray spectrometry
T2 –, MA-XRF Workshop on Developments and Applications of Macro-XRF in, Conservation, Art, and Archeology, SEP 24-25, 2017, Trieste, ITALY 48, 282 (2019). http://doi.org/10.1002/XRS.2828
Abstract: The paintings by edouard Manet in The Courtauld Gallery Dejeuner sur l'herbe (1863-68), Marguerite de Conflans en Toilette de Bal (1870-1880), Banks of the Seine at Argenteuil (1874), and A Bar at the Folies-Bergere (1882) were investigated for the first time using a range of non-invasive in situ analyses. The aims of the study were to investigate the painting techniques and materials used for this group of works and to critically evaluate the technical evidence derived from the integrated use of imaging techniques and portable spectroscopic methods in this context. The paintings were investigated by means of macro X-ray fluorescence (MA-XRF), reflection spectral imaging, portable UV-Vis-NIR spectroscopy, portable Raman spectroscopy, and reflection FTIR. MA-XRF and reflection spectral imaging allowed visualising elements in the compositions that were not visible using traditional methods of technical study. For example, MA-XRF analysis of Dejeuner sur l'herbe revealed elements of the development of the composition that provided new evidence to consider its relationship to other versions of the composition. The study also highlighted questions about the interpretation of elemental distribution maps and spectral images that did not correspond to the reworking visible in X-radiographs. For example, in A Bar at the Folies-Bergere Manet made numerous changes during painting, which were not clearly visualised with any of the techniques used. The research has wider implications for the study of Impressionist paintings, as the results will support technical studies of works by other artists of the period who used similar materials and painting methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/XRS.2828
|
|
|
“Introducing four new members of the editorial board of X-ray spectrometry”. Van Grieken R, X-ray spectrometry 44, 1 (2015). http://doi.org/10.1002/XRS.2577
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2577
|
|
|
“Introducing John Campbell, the new regional editor for North America of X-Ray Spectrometry”. Van Grieken R, X-ray spectrometry 43, 67 (2014). http://doi.org/10.1002/XRS.2534
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2534
|
|
|
“Investigation of heavy metal distributions along 15m soil profiles using EDXRF, XRD, SEM-EDX, and ICP-MS techniques”. Ozen SA, Ozkalayci F, Cevik U, Van Grieken R, X-ray spectrometry 47, 231 (2018). http://doi.org/10.1002/XRS.2832
Abstract: The research of soil contamination by heavy metal is an important field due to its environmental and health implications. The goal was to study the elemental mobility as a function of depth. For this reason, the distribution of heavy metals (V, Cr, Co, Ni, Cu, Zn, As, Sn, and Pb) was investigated along soil profiles up to a depth of 15m at 9 sampling sites in the Nilufer industrial district (Bursa, Turkey). Elemental analyses were done with the Epsilon 5 energy dispersive X-ray fluorescence and inductively coupled plasma mass spectrometry equipment. Particle analysis was performed with a JEOL scanning electron microscope equipped with a Si(Li) X-ray detector. The crystallographic compositions of oxide compounds in soil samples were identified by a Rigaku X-ray diffraction instrument. Different parameters such as the soil's chemical (mineralogical structure, pH, and electrical conductivity) and physical properties (the number of blows, the stiffness index, the liquidity index, the plasticity index, and the water content) were analyzed. To assess the mobility of the heavy metals, diffusion (D) and convection coefficients (?) were calculated with the finite difference method. Convection was determined to dominate the studied region. In addition, the mobility coefficient was determined for each metal. High mobilities were determined for Zn and V, moderate mobilities for Cr, Ni, Cu, and As, and low mobilities were determined for Co and Pb. The results revealed that elements had reached depths of up to 15m, causing irreversible soil contamination that may lead to environmental health issues.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2832
|
|
|
“Investigation on porosity changes of Lecce stone due to conservation treatments by means of x-ray nano- and improved micro-computed tomography: preliminary results”. Bugani S, Camaiti M, Morselli L, Van de Casteele E, Janssens K, X-ray spectrometry 36, 316 (2007). http://doi.org/10.1002/XRS.976
Keywords: A1 Journal article; Vision lab; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 28
DOI: 10.1002/XRS.976
|
|
|
“James Ensor's pigment use: artistic and material evolution studied by means of portable X-ray fluorescence spectrometry”. van der Snickt G, Janssens K, Schalm O, Aibéo C, Kloust H, Alfeld M, X-ray spectrometry 39, 103 (2010). http://doi.org/10.1002/XRS.1235
Abstract: In this paper, portable X-ray fluorescence spectrometry (PXRF) was employed as a screening tool for determining and comparing the pigment use in a large series of paintings by the Belgian artist James Ensor (1860-1949). Benefits and drawbacks of PXRF as a method, and the instrument employed, are discussed from a practical, conservation and instrumental perspective. Regardless of several restrictions due to the set-up and/or the analytical method, it appeared feasible to document the evolution with time in Ensor's use of inorganic pigments and to correlate this technical evolution with stylistic developments, Nevertheless, it became clear that a full identification of all materials present can only be done by means of the analysis of (cross-sectioned) samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 25
DOI: 10.1002/XRS.1235
|
|
|
“Literature trends in x-ray emission spectrometry in the period 1990-2000: a review”. Injuk J, Van Grieken R, X-ray spectrometry 32, 35 (2003). http://doi.org/10.1002/XRS.606
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.606
|
|
|
“Monte Carlo simulation of backscattered peaks in secondary target energy-dispersive X-ray spectra”. Van Dyck P, Török S, Van Grieken R, X-ray spectrometry 15, 231 (1986). http://doi.org/10.1002/XRS.1300150403
Abstract: A Monte Carlo simulation has been developed to describe the incoherent and coherent scatter processes for the complex geometry of a secondary target energy-dispersive x-ray fluorescence system. Photons are followed from the x-ray tube anode until the detection of scattered secondary target photons in the active Si layer of the detector. The program quantitatively shows the broadening of the incoherent scatter peak with increasing atomic number, and it models the incoherent peak shape adequately. The incoherent-to-coherent scatter intensity ratios obtained differ by 1030% from the theoretical values, while their dependence on the sample atomic number corresponds to that expected from theory.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150403
|
|
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
|
|
“M\alpha/L\alpha intensity ratios for Ta, W, Pt, Au, Pb and Bi for electron energies in the 11-40 keV range”. Trincavelli J, Montoro S, van Espen P, Van Grieken R, X-ray spectrometry 22, 372 (1993). http://doi.org/10.1002/XRS.1300220510
Abstract: Both energy- and wavelength-dispersive systems were used to obtain Malpha/Lalpha intensity ratios for Ta, W, Pt, Au, Pb and Bi at various overvoltages. A table of these ratios corrected for matrix absorption and detector efficiency is presented, in addition to an interpolatory function of Malpha/Lalpha generated ratios vs. overvoltage, for each element. In addition, three different ZAF correction models were used to predict both detected and generated ratios. Finally, experimental Mbeta/Malpha ratios measured at different overvoltages are presented for the six elements considered.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220510
|
|
|
“New Chinese members of the Advisory Board of X-Ray Spectrometry”. Van Grieken R, X-ray spectrometry 35, 205 (2006)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“New insights in technology characterization of medieval Valencia glazes”. Romero-Pastor J, Garcia-Porras A, Van Grieken R, Potgieter-Vermaak S, Coll-Conesa J, Cardell C, X-ray spectrometry 44, 426 (2015). http://doi.org/10.1002/XRS.2613
Abstract: This study shows the first Raman microscopy (RM) and scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX) characterization of two 14th and 15th century lead-glazed and luster ceramics from the Manises and Paterna workshops (Valencia, Spain) produced after the Aragon Christian conquest of the Iberian Peninsula (14th century). According to experts, these coetaneous ceramics were most probably involved in a process of technological transfer from the Islamic area of Southeast Spain to the Christian area of Valencia (East Spain) at the beginning of the 14th century; later on, the celebrated Manises and Paterna workshops were formed. Although these ceramics have been studied widely in terms of production technology (ceramic body, glazes and luster) using an array of diverse analytical techniques, until now, an RM study has not been carried out. This paper presents results regarding the complex chemical composition of the glaze and luster coloring agents, and the quality of color manufacturing processes, elucidating firing conditions via spectral components analysis (i.e., Q(n) for stretching/bending components) and polymerization index (Ip), emphasizing chronology and pigment technology changes between both Valencian workshops. Coloring agents identified in glazes and lusters were cobalt present in blue glazes, copper in greenish glazes, copper and cobalt in the turquoise glaze, and pyrolusite in black glazes. Tin oxyde was used as an opacifier in white glazes. Two luster manufacture recipes were recognized mainly based on copper and silver compounds. Calculated firing temperatures were up to 1000 degrees C for white glazes and up to 600 degrees C for luster and color glazes. Copyright (c) 2015 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2613
|
|
|
“New members of the editorial board of X-ray Spectrometry”. Van Grieken R, X-ray spectrometry 42, 1 (2013). http://doi.org/10.1002/XRS.2431
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2431
|
|
|
“Optimization of experimental conditions of thin-window EPMA for ligh-element analysis of individual environmental particles”. Szalóki I, Osán J, Worobiec A, de Hoog J, Van Grieken R, X-ray spectrometry 30, 143 (2001). http://doi.org/10.1002/XRS.473.ABS
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.473.ABS
|
|
|
“Optimized energy dispersive X-ray fluorescence analysis of atmospheric aerosols collected at pristine and perturbed Amazon Basin sites”. Arana A, Loureiro AL, Barbosa HMJ, Van Grieken R, Artaxo P, X-ray spectrometry 43, 228 (2014). http://doi.org/10.1002/XRS.2544
Abstract: Elemental composition of aerosols is important to source apportionment studies and to understand atmospheric processes that influence aerosol composition. Energy dispersive X-ray fluorescence spectroscopy was applied for measuring the elemental composition of Amazonian atmospheric aerosols. The instrument used was a spectrometer Epsilon 5, PANalytical B. V., with tridimensional geometry that reduces the background signal with a polarized X-ray detection. The measurement conditions were optimized for low-Z elements, e. g. Mg, Al, Si, that are present at very low concentrations in the Amazon. From Na to K, our detection limits are about 50% to 75% lower than previously published results for similar instrument. Calibration was performed using Micromatter standards, except for P whose standard was produced by nebulization of an aqueous solution of KH2PO4 at our laboratory. The multi-element reference material National Institute of Standards and Technology-2783 (air particulate filter) was used for evaluating the accuracy of the calibration procedure of the 22 elements in our standard analysis routine, and the uncertainty associated with calibration procedures was evaluated. The overall performance of the instrument and validation of our measurements were assessed by comparison with results obtained from parallel analysis using particle-induced X-ray emission and another Epsilon 5 spectrometer. The elemental composition in 660 samples collected at a pristine site in the Amazon Basin and of 1416 samples collected at a site perturbed by land use change was determined. Our measurements show trace elements associated with biogenic aerosols, soil dust, biomass burning, and sea-salt, even for the very low concentrations as observed in Amazonia. Copyright (C) 2014 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2544
|
|
|
“Performance of a new compact EDXRF spectrometer for aerosol analysis”. Samek L, Injuk J, van Espen P, Van Grieken R, X-ray spectrometry 31, 84 (2002). http://doi.org/10.1002/XRS.551
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.551
|
|
|
“Preface to the special issue on: MA-XRF “developments and applications of macro-XRF in conservation, art, and archeology&rdquo, (Trieste, Italy, 24 and 25 September 2017)”. Romano FP, Janssens K, X-ray spectrometry 48, 249 (2019). http://doi.org/10.1002/XRS.3047
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/XRS.3047
|
|
|
“Progress in laboratory grazing emission X-ray fluorescence spectrometry”. Claes M, de Bokx P, Van Grieken R, X-ray spectrometry 28, 224 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
|
|
|
“Radiometric diameter concept and exact intensities for spherical particles in x-ray fluorescence analysis”. Markowicz A, Van Dyck P, Van Grieken R, X-ray spectrometry 9, 52 (1980). http://doi.org/10.1002/XRS.1300090205
Abstract: In X-ray fluorescence analysis the concept of radiometric diameter, d, is often introduced in considerations of the fluorescent intensity from a particulate sample. It represents the mean geometric path of the X-rays through one particle and is usually simply taken to be equal to the volume-to-area ratio of the particle. The effective radiometric path is, however, itself dependent on geometry and absorption effects. Rigorous calculations of the fluorescent intensity from a particle in the π and π/2 geometries were carried out to evaluate the errors involved. It appears that, for π geometry, the discrepancy between these exact results and the intensity calculated via the use of d does not exceed 5.2%. For the π/2 geometry, the errors are much larger and can amount to 50% in realistic cases of X-ray fluorescence analysis. These conclusions are also applicable to monolayers. The effective radiometric diameter approaches d only when absorption effects become negligible, but is smaller in other cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300090205
|
|