|
“Secondary ion formation of low molecular weight organic dyes in time-of-flight static secondary ion mass spectrometry”. Lenaerts J, van Vaeck L, Gijbels R, Rapid communications in mass spectrometry 17, 2115 (2003). http://doi.org/10.1002/rcm.1160
Abstract: Time-of-flight static secondary ion mass spectrometry (TOF-S-SIMS) was used to characterize thin layers of oxy- and thiocarbocyanine dyes on Ag and Si. Apart from adduct ions a variety of structural fragment ions were detected for which a fragmentation pattern is proposed. Peak assignments were confirmed by comparing spectra of dyes with very similar structures. All secondary ions were assigned with a mass accuracy better than 50 ppm. The intensity of molecular ions as well as fragment ions has been studied as a function of the type of organic dye, the substrate, the layer thickness and the type of primary ion. A large yield difference of two orders of magnitude was observed between the precursor ions of cationic carbocyanine dyes and the protonated molecules of the anionic dyes. Fragment ions, on the other hand, yielded similar intensities for both types of dye. As the dye layers deposited on an Ag substrate yielded higher secondary ion intensities than those deposited on a Si substrate, the Ag metal clearly acts as a promoting agent for secondary ion formation. The effect was more pronounced for precursor signals than for fragment ions. The promoting effect decreased as the deposited layer thickness of the organic dye layer was increased. Copyright (C) 2003 John Wiley Sons, Ltd.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.998
Times cited: 10
DOI: 10.1002/rcm.1160
|
|
|
“Static secondary ion mass spectrometry (S-SIMS): part 1: methodology and structural interpretation”. van Vaeck L, Adriaens A, Gijbels R, Mass spectrometry reviews 18, 1 (1999)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 9.373
Times cited: 112
|
|
|
“Structural characterization of organic molecules by laser mass spectrometry”. van Vaeck L, van Roy W, Gijbels R, Adams F Wiley, New York, page 177 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“The analysis of volatile siloxanes in waste activated sludge”. Dewil R, Appels L, Baeyens J, Van Vaeck L, Buczyńska A, Talanta 74, 14 (2007). http://doi.org/10.1016/J.TALANTA.2007.05.041
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.05.041
|
|
|
“The feasibility of Fourier transform laser microprobe mass spectrometry for applications of local and surface analysis”. Struyf H, van Roy W, Van Vaeck L, Van Grieken R, Caravatti P, Proceedings of the European FTMS Workshop (1994)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“TOF-SIMS analysis of carbocyanine dyes adsorbed on silver substrates”. Lenaerts J, Verlinden G, van Vaeck L, Gijbels R, Geuens I, , 115 (2000)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Use of solid-phase microextraction for the detection of acetic acid by ion-trap gas chromatography-mass spectrometry and application to indoor levels in museums”. Godoi AFL, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1067, 331 (2005). http://doi.org/10.1016/J.CHROMA.2004.12.054
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2004.12.054
|
|