“Determination of BTEX by GCMS in air of offset printing plants: comparison between conventional and ecological inks”. Godoi AFL, Sawada EY, de Marchi MRR, Van Grieken R, Godoi RHM, Water, air, and soil pollution : focus 9, 163 (2009). http://doi.org/10.1007/S11267-009-9219-9
Abstract: The use of inks containing organic solvents by the offset printing process implies in the release of volatile organic compounds to the work environment. Many of these compounds such as benzene, toluene, ethylbenzene, and the xylene isomers (well known by the acronym BTEX) are extremely toxic. In this study, the BTEX concentrations were determined in two different printing plants that use distinct types of inks: the conventional and the so-called ecological, which is manufactured based on vegetal oil. Concentration ranges were 4384, 153,480, 2133, 5459, and 2236 μg m−3 for benzene, toluene, ethylbenzene, m + p-xylene, and o-xylene, respectively, for the conventional printing plant. At the ecological printing plant, concentration ranges were below limit of detection (<LD)-31, <LD-618, <LD-1,690, <LD-10,500, <LD-3,360 μg m−3 for benzene, toluene, ethylbenzene, m + p-xylene, and o-xylene, respectively. BTEX concentrations are lower at the ecological printing environment than in the conventional, where mineral oil-based inks are used. However, the worker who cleans the printing matrices is exposed to high concentrations of ethylbenzene and xylenes, due probably to the cleaning products composition (containing high amounts of BTEX). Although the BTEX concentrations found in both printing work environments were below the limits considered by the Brazilian Law for Activities and Unhealthy Operations (NR-15), the exposure to such vapors characterizes risk to the workers health for some of the evaluated samples, mainly the personal ones.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S11267-009-9219-9
|
|
|
“Determination of chemical composition of individual airborne particles by SEM/EDX and micro-Raman spectrometry : a review”. Stefaniak EA, Buczyńska A, Novakovic V, Kuduk R, Van Grieken R, Journal of physics : conference series 162, 012019 (2009). http://doi.org/10.1088/1742-6596/162/1/012019
Abstract: The strategies for sampling and analysis by SEM/EDX and micro-Raman spectrometry for individual airborne particles analysis as applied at the University of Antwerp (Belgium) by the MITAC group have been reviewed. Microbeam techniques provide detailed information concerning the origin, formation, transport, reactivity, transformation reactions and environmental impact of particulate matter. Moreover, some particles of certain chemical properties have been recognized as a threat for human health and cultural heritage objects. However, the small sizes of particles result in specific problems with respect to single particle analysis. Development of equipment and software for improvement of analysis and quantification are reported.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1088/1742-6596/162/1/012019
|
|
|
“Determination of chemical species in individual aerosol particles using ultrathin window EPMA”. Ro C-U, Osán J, Szalóki I, Oh K-Y, Kim H, Van Grieken R, Environmental science and technology 34, 3023 (2000). http://doi.org/10.1021/ES9910661
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES9910661
|
|
|
“Determination of fluorine in uranium oxyfluoride particles as an indicator of particle age”. Kips R, Pidduck AJ, Houlton MR, Leenaers A, Mace JD, Marie O, Pointurier F, Stefaniak EA, Taylor PDP, van den Berghe S, van Espen P, Van Grieken R, Wellum R, Spectrochimica acta: part B : atomic spectroscopy 64, 199 (2009). http://doi.org/10.1016/J.SAB.2008.12.001
Abstract: As swipe samples from enrichment activities typically contain uranium particles with a detectable amount of fluorine, the question was raised whether the analysis of fluorine in particles could complement the information on the uranium isotope ratios. For this, uranium oxyfluoride particles were prepared from the controlled hydrolysis of uranium hexafluoride (UF6). The relative amount of fluorine was characterized by scanning electron microscopy combined with energy-dispersive X-ray spectrometry (SEM-EDX), as well as ion-microprobe secondary ion mass spectrometry (IM-SIMS). Of particular interest was the assessment of the reduction of the amount of fluorine over time, and after exposure to UV-light and high temperatures. Micro-Raman spectrometry (MRS) was applied to look for differences in molecular structure between these various sample types. Both SEM-EDX and IM-SIMS showed a general reduction of the fluorine-to-uranium ratio after 12 years of storage. The exposure to UV-light and high temperatures was found to have accelerated the loss of fluorine. A distinct peak at 865 cm− 1 Raman shift was detected for the majority of particles analyzed by MRS. For the particles that were heat-treated, the Raman spectra were similar to the spectrum of U3O8. Although often large variations were observed between particles from the same sample, the three particle measurement techniques (IM-SIMS, SEM-EDX and MRS) showed some consistent trends. They therefore appear promising in terms of the ability to place bounds on particle age, as well as shedding light on the complex processes involved in UO2F2 particle ageing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/J.SAB.2008.12.001
|
|
|
“Determination of light elements in marine aerosols by grazing-emission X-ray fluorescence”. Schmeling M, Van Grieken R, (1999)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of low-Z elements in individual environmental particles using windowless EPMA”. Ro C-U, Osán J, Van Grieken R, Analytical chemistry 71, 1521 (1999). http://doi.org/10.1021/AC981070F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC981070F
|
|
|
“Determination of methanesulfonic acid and non-sea-salt sulfate in single marine aerosol particles”. Kolaitis LN, Bruynseels FJ, Van Grieken RE, Andreae MO, Environmental science and technology 23, 236 (1989). http://doi.org/10.1021/ES00179A018
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES00179A018
|
|
|
van Grieken R, Gijbels R, Speecke A, Hoste J (1971) Determination of oxygen, silicon, phosphorus and copper in iron and steel by 14 MeV neutron activation analysis. S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of platinum, palladium, and rhodium in automotive catalysts using high-energy secondary target X-ray fluorescence spectrometry”. van Meel K, Smekens A, Behets M, Kazandjian P, Van Grieken R, Analytical chemistry 79, 6383 (2007). http://doi.org/10.1021/AC070815R
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC070815R
|
|
|
“Determination of protein-bound copper and zinc in some organs of the cuttlefish Sepia officinalis L”. Decleir W, Vlaeminck A, Geladi P, Van Grieken R, Comparative biochemistry and physiology : B : biochemistry and molecular biology 60, 347 (1978). http://doi.org/10.1016/0305-0491(78)90057-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0305-0491(78)90057-3
|
|
|
“Determination of rare earth elements in geological materials by total reflection X-ray fluorescence”. Muia LM, Van Grieken R, Analytica chimica acta 251, 177 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of sample thickness via scattered radiation in X-ray fluorescence spectrometry with filtered continuum excitation”. Araujo MF, van Espen P, Van Grieken R, X-ray spectrometry 19, 29 (1990). http://doi.org/10.1002/XRS.1300190107
Abstract: A semi-empirical approach is described for determining the mass per unit area of a sample being analysed. The method can be used to estimate the concentration of minor and trace elements in matrices containing a substantial amount of light elements. The procedure utilizes the coherently and incoherently scattered radiation induced in the sample by the filtered continuum radiation of a rhodium x-ray tube. The relationship between the intensity of the scattered radiation per unit mass and the average atomic number of the sample is established via calibration graphs, which can be applied for different x-ray tube voltages and for different primary beam filters. The overall procedure was validated by the analysis of several geological standards, deposited as thin slurries of unknown thickness either on Mylar foil or on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300190107
|
|
|
“Determination of selenium in blood components by X-ray emission spectrometry”. Robberecht H, Deelstra H, Van Grieken R, Biological trace element research 25, 149 (1990). http://doi.org/10.1007/BF02990412
Abstract: Sampling, storing, sample pretreatment, and experimental conditions for selenium (Se) determination in human serum, plasma, and whole blood by X-ray emission spectrometric (XRS) methods are described. Concentration levels in these biological fluids, found by this technique, are discussed and compared to values found by other techniques for the same healthy population group in the same area. XRS analysis of blood from patients with various pathological conditions is reviewed, with special attention to the relation of Se with the concentration level of other essential or nonessential trace elements.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02990412
|
|
|
“Determination of silicon in organic matrices with grazing-emission X-ray fluorescence spectrometry”. Claes M, van Dyck K, Deelstra H, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 54, 1517 (1999). http://doi.org/10.1016/S0584-8547(99)00098-1
Abstract: The potential of a prototype grazing-emission X-ray fluorescence spectrometer for reliable analysis of sample solutions, obtained by pressurized microwave oven digestion of Si-spiked organic and biological materials, was investigated as part of an inter-laboratory study. The fact that this grazing-emission technique is based on the total reflection phenomenon and wavelength-dispersive detection, gives it the benefit to determine light elements in a sensitive way. Results of the determination of silicon in pork liver, cellulose, urine, serum, spinach, beer, mineral water and horsetail (dry plant extract) samples are presented. Some of the results are compared with those obtained with other analytical techniques. The study proved that determination of silicon traces in biological matrices represents an extremely difficult task, however, measurements of silicon are achieved with acceptable precision. The most important problems still arise when sample pre-treatment is needed prior to analysis. (C) 1999 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00098-1
|
|
|
“Determination of trace elements in organic matrices by grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken R, Analytica chimica acta 401, 293 (1999). http://doi.org/10.1016/S0003-2670(99)00471-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(99)00471-7
|
|
|
“Determination of trace metals in rain water by differential-pulse stripping voltammetry”. Vos L, Komy G, Reggers G, Roekens E, Van Grieken R, Analytica chimica acta 184, 271 (1986). http://doi.org/10.1016/S0003-2670(00)86491-0
Abstract: Differential-pulse stripping voltammetry is applied to measure zinc, cadmium, lead and copper by anodic stripping and selenium(IV) by cathodic stripping in rain water at pH 2; subsequently, at pH 9,1, manganese is measured by anodic stripping on the same portion, and cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The instrumental parameters are optimized. The linear ranges, mutual interferences and detection limits are studied. Excellent accuracy is demonstrated; the standard deviation is around 15% at 2.550 μg l−1 levels. The method is shown to be applicable for rain water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)86491-0
|
|
|
“Determination of trace selenium in biological material by preconcentration and X-ray emission spectrometry”. Robberecht H, Van Grieken R, Analytica chimica acta 147, 113 (1983). http://doi.org/10.1016/0003-2670(83)80077-4
Abstract: Selenium is determined in the ng g−1 to μg g−1 range in biological and environmental samples. A wet digestion procedure was optimized with respect to volatility losses and recovery yields, by using 75Se metabolically incorporated into rat organs. Selenium is preconcentrated from the digestion liquid by a two-step reduction with 4 M HCl and ascorbic acid. The colloidal selenium formed is adsorbed on activated carbon and filtered on a Nucleopore membrane for measurement by energy-dispersive x-ray fluorescence. Almost complete recovery was obtained, and the detection limit was 20 ng, corresponding to 10 ng g−1 for a 2-g sample. Biological reference materials were analyzed with satisfactory results, and the accuracy of the method was good.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(83)80077-4
|
|
|
“Determination of ultra-trace levels of palladium in environenmental samples by graphite furnace atomic spectrometry techniques”. Bencs L, Ravindra K, Van Grieken R page 173 (2006).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Die risikoprofiel van Pb en Cr in stedelike padstof”. Potgieter-Vermaak S, Van Grieken R, Potgieter H, Litnet akademies : 'n joernaal vir die geesteswetenskappe 9, 1 (2012)
Abstract: The risk profile of Cr and Pb in urban road deposited sediment Exponential urbanisation and industrial growth occur on a global scale and result in an ecological burden, of which one important part is pollution. It is well known that the extent of air pollution has escalated over the past two decades in several parts of the world, despite mitigating measures and legislation. Current research points to the fact that air pollution in urban and industrial areas is substantially different from that found in rural areas. Road dust (RD) contributes up to 35% of airborne particulate matter due to resuspension thereof, and poses a health concern due to carcinogenic and toxic components potentially present in the micron-sized fractions. Although literature does report on the concentrations of trace, toxic metals and metalloids present in RD (Hooker and Nathanail 2006), the molecular make-up of particulates generated due to the resuspension of the RD is not well documented. In vitro and animal toxicological studies have confirmed that the chemical composition of inhaled particles plays a major role in its toxic, genotoxic and carcinogenic mechanisms, but the component-specific toxic effects are still not understood. Transition metals binding to air particle matter can result in reactive oxygen species in the human body (particularly in the lungs), and this is a significant risk, especially for vulnerable population groups like elderly people, children and terminally ill patients. The characterisation of the molecular composition of the fine fraction is evidently of importance for public health. During an earlier study, road dust from an inner-city environment in the UK was collected and partially characterised (Barrett e.a. 2010). These same-size fractions were analysed for their elemental concentrations, using X-ray Fluorescence Spectrometry (XRFS) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). In addition, single-particle analysis was performed on the different fractions by means of Computer Controlled Electron Probe X-ray Micro Analysis (CC-EPXMA) and their molecular structure probed by studying elemental associations. These findings were correlated with Micro Raman Spectroscopy (MRS) results. It was found that the fine fraction (<38 μm) had the highest Pb (238 ppm) and Cr (171 ppm) concentrations. The CC-EPXMA data showed >50% association of Cr-rich particles with Pb and the MRS data showed that the Cr was mostly present as lead chromate and therefore in the Cr(VI) oxidation state. Concentrations of both Pb and Cr decreased substantially (279 (<38 mm) 13 ppm (<1mm); 171 (<38 mm) 91 ppm (<1mm) respectively) in the larger fractions. Apart from rather alarmingly high concentrations of oxidative stressors (Cu, Fe, Mn), the carcinogenic and toxic potential of the inhalable fraction is evident. Preliminary bioaccessibility data indicated that both Cr and Pb are readily
Keywords: A2 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Direct current glow discharge mass spectrometric analysis of Macor ceramic using a secondary cathode”. Schelles W, Van Grieken R, Analytical chemistry 68, 3570 (1996). http://doi.org/10.1021/AC960441U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC960441U
|
|
|
“Direct current glow discharge mass spectrometry for elemental characterization of polymers”. Schelles W, Van Grieken R, Analytical chemistry 69, 2931 (1997). http://doi.org/10.1021/AC970186T
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC970186T
|
|
|
“Direct detection of sulfate and nitrate layers on sampled marine aerosols by laser microprobe mass analysis”. Bruynseels F, Van Grieken R, Atmospheric environment 19, 1969 (1985). http://doi.org/10.1016/0004-6981(85)90023-X
Abstract: The direct detection of sulfate and nitrate layers on sampled marine aerosols was carried out by laser microprobe mass analysts.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0004-6981(85)90023-X
|
|
|
“Discrimination between coprecipitated and adsorbed lead on individual calcite particles using laser microprobe mass analysis”. Wouters LC, Van Grieken RE, Linton RW, Bauer CF, Analytical chemistry 60, 2218 (1988). http://doi.org/10.1021/AC00171A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00171A011
|
|
|
“Dispersal of suspended matter in Makasar Strait and the Flores Basin”. Eisma D, Kalf J, Karmini M, Mook WG, Van Put A, Bernard P, Van Grieken R, Netherlands journal of sea research 24, 383 (1989). http://doi.org/10.1016/0077-7579(89)90116-6
Abstract: In November 1984 in Makasar and the Flores Basin water samples were collected (T, S, dissolved O2, total CO2), bottom samples (sediment composition) and suspended matter (particle composition, particle size). A sediment trap was moored in the Flores Basin at 4600 m depth for nearly four months, covering the dry season. In the Flores Basin there are indications for bottom flow resuspending bottom material or preventing suspended material from settling; in Makasar Strait there is probably inflow of deep water both from the south and from the north, resulting in a very slow bottom water flor. Bottom deposits in Makasar Strait and the Flores Basin are predominantly terrigenous, with an admixture of organic carbonate and silica (mostly coccoliths). Volcanic material is primarily present near to the volcanoes in the south and reaches the deeper basins by slumping. In the suspended matter no volcanic particles and little planktonic material were found, although the latter form 10 to 15% of the top sediment and of the material deposited in the sediment trap. In suspension particles with a large concentration of tin (Sn) were found associated mainly with iron. They probably come from northern Kalimantan or northern Sulawesi. Suspended matter concentrations were mainly less than 0.5 mg·dm−3, only off the Mahakam river mouth were concentrations higher than 1 mg·dm−3. Particle size was erratic because of the variable composition of the coarser particles in suspension. Organic matter concentrations in suspension (in mg·dm−3) roughly follow the distribution of total suspended matter but organic content (in %) of the suspended matter does not show any trends. All organic matter in suspension is of marine origin except in the Mahakam river and estuary. Deposition rates, as estimated from the sediment trap results, are 150 mg·cm−2·a−1 for the total sediment, 26 mg·cm−2·a−1 for carbonate and 13 mg·cm−2·a−1 for organic matter. Flocs and fibres in suspension were only found in and below the Mahakam river plume that reaches ca 400 km from the river mouth to the southeast, and in surface waters associated with plankton (diatoms). The formation of these flocs (broken-up macroflocs or marine snow) is primarily related to particle concentration, turbulence, and the presence of organisms that produce sticky material or glue particles together.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(89)90116-6
|
|
|
“Dispersion of heavy metals”. Van Grieken R page 319 (1998).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Distribution and composition of suspended matter around Sumbawa Island, Indonesia”. Eisma D, van Put A, Van Grieken R, Mitteilungen aus dem Geologisch-Paläontologischen Institut der Universität Hamburg 70, 137 (1992)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Distribution of atmospheric marine salt depositions over Continental Western Europe”. Delalieux F, Van Grieken R, Potgieter JH, Marine pollution bulletin 52, 606 (2006). http://doi.org/10.1016/J.MARPOLBUL.2005.08.018
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MARPOLBUL.2005.08.018
|
|
|
“Do gaseous pollutants and particulate matter endanger our world heritage? A study in the Museum Plantin-Moretus, Antwerp”. Janssen E, Kontozova-Deutsch V, Krupińska B, Moris H, Peckstadt A, van Bos M, Watteeuw L, Van Grieken R, (2010)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Doped albumin : stndardization possibilities for LAMMA-analysis of thin freeze-dried cryosections of biological tissue”. Verbueken AH, Jacob WA, Frederik PM, Busing WM, Hersten RC, Van Grieken RE, Journal de physique 45, 561 (1984)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Dry aerosol deposition over the North Sea estimated from aircraft measurements”. Rojas CM, Otten PM, Van Grieken RE, Laane R page 419 (1991).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|