“Water quality assessment in Pangani river basin, Tanzania : natural and anthropogenic influences on concentrations of nutrients and inorganic ions”. Hellar-Kihampa H, De Wael K, Lugwisha E, Van Grieken R, International journal of river basin management 11, 55 (2013). http://doi.org/10.1080/15715124.2012.759119
Abstract: The ongoing rapid expansions of human activities and population dynamics have potential impact on the environmental quality of the Pangani river basin, one of the largest water resources in Tanzania, including possible loadings of different kinds of micro-contaminants. However, specific extents of the impacts are rather not well investigated. In this work, we assessed the environmental quality of the basin, based on seasonal characterisation of physicochemical water and sediments parameters, dissolved inorganic ions and nutrient loads. The contributions of geochemical processes and land-use practices were evaluated by multivariate correlations and principal component analysis (PCA). Hierarchical cluster analysis was used to classify similar water quality stations and identify the most and least enriched ones. Surface waters were slightly alkaline, characterised by low total dissolved solids (48652 mg/L). Extremely low oxygen concentration (2.0 mg/L) was also a cause of concern at one station. The Na+ and HCO3 − ions provided the dominant cation and anion, respectively. PCA identified weathering of carbonate and Na+ bearing rocks, gypsum dissolution and atmospheric deposition of sea-salt as the major factors controlling the ionic composition, contributing more than 60% of the spatial variance. Concentration profiles of the chemical species showed a generally low level of anthropogenic inputs, except at a few locations where nitrate and nitrite were significantly enriched above the limits of safe exposure, with patterns indicating influences of farming and livestock keeping. A seasonal difference was observed, with lower ion concentrations during the rainy season, likely due to the dilution effect of increased water discharge. The study provides new insights into the environmental quality of the basin, and indicates the need for continuous monitoring and assessment of the chemical species in the area.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/15715124.2012.759119
|
|
|
“Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs”. Teymourian H, Parrilla M, Sempionatto JR, Montiel NF, Barfidokht A, Van Echelpoel R, De Wael K, Wang J, Acs Sensors 5, 2679 (2020). http://doi.org/10.1021/acssensors.0c01318
Abstract: Wearable electrochemical sensors capable of noninvasive monitoring of chemical markers represent a rapidly emerging digital-health technology. Recent advances toward wearable continuous glucose monitoring (CGM) systems have ignited tremendous interest in expanding such sensor technology to other important fields. This article reviews for the first time wearable electrochemical sensors for monitoring therapeutic drugs and drugs of abuse. This rapidly emerging class of drug-sensing wearable devices addresses the growing demand for personalized medicine, toward improved therapeutic outcomes while minimizing the side effects of drugs and the related medical expenses. Continuous, noninvasive monitoring of therapeutic drugs within bodily fluids empowers clinicians and patients to correlate the pharmacokinetic properties with optimal outcomes by realizing patient-specific dose regulation and tracking dynamic changes in pharmacokinetics behavior while assuring the medication adherence of patients. Furthermore, wearable electrochemical drug monitoring devices can also serve as powerful screening tools in the hands of law enforcement agents to combat drug trafficking and support on-site forensic investigations. The review covers various wearable form factors developed for noninvasive monitoring of therapeutic drugs in different body fluids and toward on-site screening of drugs of abuse. The future prospects of such wearable drug monitoring devices are presented with the ultimate goals of introducing accurate real-time drug monitoring protocols and autonomous closed-loop platforms toward precise dose regulation and optimal therapeutic outcomes. Finally, current unmet challenges and existing gaps are discussed for motivating future technological innovations regarding personalized therapy. The current pace of developments and the tremendous market opportunities for such wearable drug monitoring platforms are expected to drive intense future research and
commercialization efforts.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.9
DOI: 10.1021/acssensors.0c01318
|
|
|
“Wearable self‐powered electrochemical devices for continuous health management”. Parrilla M, De Wael K, Advanced Functional Materials 31, 2107042 (2021). http://doi.org/10.1002/ADFM.202107042
Abstract: The wearable revolution is already present in society through numerous gadgets. However, the contest remains in fully deployable wearable (bio)chemical sensing. Its use is constrained by the energy consumption which is provided by miniaturized batteries, limiting the autonomy of the device. Hence, the combination of materials and engineering efforts to develop sustainable energy management is paramount in the next generation of wearable self-powered electrochemical devices (WeSPEDs). In this direction, this review highlights for the first time the incorporation of innovative energy harvesting technologies with top-notch wearable self-powered sensors and low-powered electrochemical sensors toward battery-free and self-sustainable devices for health and wellbeing management. First, current elements such as wearable designs, electrochemical sensors, energy harvesters and storage, and user interfaces that conform WeSPEDs are depicted. Importantly, the bottlenecks in the development of WeSPEDs from an analytical perspective, product side, and power needs are carefully addressed. Subsequently, energy harvesting opportunities to power wearable electrochemical sensors are discussed. Finally, key findings that will enable the next generation of wearable devices are proposed. Overall, this review aims to bring new strategies for an energy-balanced deployment of WeSPEDs for successful monitoring of (bio)chemical parameters of the body toward personalized, predictive, and importantly, preventive healthcare.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 12.124
DOI: 10.1002/ADFM.202107042
|
|
|
“Weathering mechanism of Pentelic marble under ambient atmospheric conditions derived from runoff studies”. Delalieux F, Sweevers H, Van Grieken R, (1997)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Weathering of bare and treated limestones under ambient conditions using runoff water analysis and microanalysis”. Vleugels G, Van Grieken R, (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Weathering of dolomitic sandstone under ambient conditions”. Sweevers H, Delalieux F, Van Grieken R, Atmospheric environment : an international journal 32, 733 (1998). http://doi.org/10.1016/S1352-2310(97)00341-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1352-2310(97)00341-5
|
|
|
“Weathering of Leinster granite under ambient atmospheric conditions”. Sweevers E, Peeters A, Van Grieken R, The science of the total environment 167, 73 (1995). http://doi.org/10.1016/0048-9697(95)04571-H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(95)04571-H
|
|
|
“Weathering of treated and untreated limestones in atmospheric exposures”. Vleugels GJ, Van Grieken RE, Journal of preservation technology 23, 48 (1991)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Weathering products and surface recession rates for sandy limestones exposed to air pollution”. Roekens E, Van Raemdonck C, Leysen L, Chakravorty R, Van Grieken R page 707 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Van Grieken R (1998) Working close to the detection limits: XRF
Keywords: Minutes and reports; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Wpływ zwiedzajacych na zanieczyszczenia wnetrz muzealnych”. Samek L, Worobiec A, Van Grieken R, van Meel K, Kontozova V, Karaszkiewicz P, Wiłkojć E page 209 (2007).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“X ray fluorescence in member states: Belgium: integration of analysis techniques of different scales using X ray induced and electron induced X ray spectrometry for applications in preventive conservation and environmental monitoring”. Van Grieken R, Potgieter-Vermaak S, Darchuk L, Worobiec A, XRF newsletter , 9 (2009)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“X-ray analysis of riverbank sediment of the Tisza (Hungary): identification of particles from a mine pollution event”. Osán J, Kurunczi S, Török S, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 57, 413 (2002). http://doi.org/10.1016/S0584-8547(01)00405-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00405-0
|
|
|
“X-ray based methods of analysis”. Janssens K page 129 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray diffraction mapping for cultural heritage science : a review of experimental configurations and applications”. Gonzalez V, Cotte M, Vanmeert F, de Nolf W, Janssens K, Chemistry: a European journal 26, 1703 (2019). http://doi.org/10.1002/CHEM.201903284
Abstract: X-ray diffraction (XRD) mapping consists in the acquisition of XRD patterns at each pixel (or voxel) of an area (or volume). The spatial resolution ranges from the micrometer (mu XRD) to the millimeter (MA-XRD) scale, making the technique relevant for tiny samples up to large objects. Although XRD is primarily used for the identification of different materials in (complex) mixtures, additional information regarding the crystallite size, their orientation, and their in-depth distribution can also be obtained. Through mapping, these different types of information can be located on the studied sample/object. Cultural heritage objects are usually highly heterogeneous, and contain both original and later (degradation, conservation) materials. Their structural characterization is required both to determine ancient manufacturing processes and to evaluate their conservation state. Together with other mapping techniques, XRD mapping is increasingly used for these purposes. Here, the authors review applications as well as the various configurations for XRD mapping (synchrotron/laboratory X-ray source, poly-/monochromatic beam, micro/macro beam, 2D/3D, transmission/reflection mode). On-going hardware and software developments will further establish the technique as a key tool in heritage science.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 5.317
DOI: 10.1002/CHEM.201903284
|
|
|
“X-ray fluorescence”. Injuk J, Van Grieken RE page 151 (2001).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray fluorescence analysis”. Janssens K (2003).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray fluorescence analysis, sample preparation for”. Margu'i' E, Queralt I, Van Grieken R page 1 (2009).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-Ray Fluorescence as an analytical tool for studying the copper matrices in the collection of the Museum Plantin-Moretus”. Storme P, Fransen E, De Wael K, Caen J, De gulden passer 95, 7 (2017)
Keywords: A1 Journal article; Engineering sciences. Technology; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
|
|
“X-ray fluorescence microtomography”. Chukalina M, Simionovici AS, Snigirev A, Drakopoulos M, Snigireva I, Adams F, Janssens K, Poverhnost 3, 40 (2001)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray fluorescence microtomography and polycapillary based confocal imaging using synchrotron radiation”. Vincze L, Vekemans B, Szaloki I, Brenker FE, Falkenberg G, Rickers K, Aerts K, Van Grieken R, Adams F, , 220 (2004). http://doi.org/10.1117/12.560416
Abstract: Ibis work illustrates the development of X-ray fluorescence tomography and polycapillary based confocal imaging towards a three-dimensional (313), quantitative analytical method with lateral resolution levels down to the 2-20 mum scale. Detailed analytical characterization is given for polycapillary based confocal XRF imaging, which is a new variant of the 3D micro-XRF technique. Applications for 2D/3D micro-XR-F are illustrated for the analysis of biological (zooplankton) and geological samples (microscopic inclusions in natural diamonds and fluid inclusions in quartz). Based on confocal imaging, fully three-dimensional distributions of trace elements could be obtained, representing a significant generalization of the regular 2D scanning technique for micro-XRF spectroscopy. The experimental work described in this paper has been carried out at the ESRF ID18F microfluorescence end-station and at HASYLAB Beam Line L.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.560416
|
|
|
“X-ray fluorescence microtomography: experiment and reconstruction”. Simionovici AS, Chukalina M, Drakopoulos M, Snigireva I, Snigirev A, Schroer C, Lengeler B, Janssens K, Adams F page 304 (1999).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Marguí, E, Van Grieken R (2013) X-ray fluorescence spectrometry and related techniques : an introduction. 148 p
Keywords: MA3 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray micro-analysis of aluminium in pumpkinseed gills”. Eeckhaoudt S, Jacob W, Witters H, Van Grieken R, European journal of morphology 31, 42 (1993)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray micro-analysis of aluminium in pumpkinseed gills”. Eeckhaoudt S, Jacob W, Witters H, Van Grieken R, European journal of morphology 30, 296 (1992)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray microanalysis: a new tool for environmental analysis”. Adams F, Janssens K page 183 (1996).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray optics for synchrotron-radiation-induced X-ray micro fluorescence at the european synchrotron-radiation facility, Grenoble”. Vincze L, Janssens K, Adams F, Institute of physics conference series , 613 (1993)
Abstract: Different optical designs for generating synchrotron x-ray micro beams suitable for use in an X-ray fluorescence microscope using an ESRF bending magnet X-ray source are compared. Attention is devoted to the spatial and energy distribution of the photons in the micro beam and to the minimum detection limits that are achievable with each alternative optical system.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 78, 4069 (2006). http://doi.org/10.1021/AC060688J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC060688J
|
|
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 76, 3445 (2004). http://doi.org/10.1021/AC0400820
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC0400820
|
|
|
“X-ray spectrometry”. Szalóki I, Török SB, Injuk J, Van Grieken RE, Analytical chemistry 74, 2895 (2002). http://doi.org/10.1021/AC020241K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC020241K
|
|