“Platinum group elements in the environment and their health risk”. Ravindra K, Bencs L, Van Grieken R, The science of the total environment 318, 1 (2004). http://doi.org/10.1016/S0048-9697(03)00372-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0048-9697(03)00372-3
|
“Point defect reactions in silicon studies in situ by high flux electron irradiation in high voltage transmission electron microscope”. Vanhellemont J, Romano-Rodriguez A, Fedina L, van Landuyt J, Aseev A, Materials science and technology 11, 1194 (1995)
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 7
|
“Polarized-beam high-energy EDXRF in geological samples”. Čevik U, Akbulut S, Makarovska Y, Van Grieken R, Spectroscopy letters 46, 36 (2013). http://doi.org/10.1080/00387010.2012.661015
Abstract: Certified reference materials (NIST 1645, BCR 143, IAEA 7, BCR 141, NIESCRM02, and IAEA 375) were used for determining the performance of a secondary target energy-dispersive X-ray fluorescence (EDXRF) spectrometer, Epsilon 5 (PANalytical, Almelo, the Netherlands). For the evaluation of the EDXRF spectra with polarized-beam high-energy excitation, the WinAxil software package has been applied. The results showed that Epsilon 5, EDXRF spectrometry is favorable for the determination of elemental concentrations in geological samples, but the sample preparation has the largest influence on the precision. However, they presented good agreement with certified values for most of the elements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/00387010.2012.661015
|
“Polaron cyclotron resonance spectrum with interface optical phonon modes in GaAs/AlAs quantum wells”. Hai GQ, Peeters FM, Devreese JT Kluwer, Dordrecht, page 243 (1993).
Keywords: H3 Book chapter; Condensed Matter Theory (CMT); Theory of quantum systems and complex systems
|
“Polaron effects in heterostructures, quantum wells and superlattices”. Peeters FM, Devreese JT, , 99 (1994)
Keywords: P1 Proceeding; Condensed Matter Theory (CMT); Theory of quantum systems and complex systems
Times cited: 1
|
“Polycapillary X-ray optics”. Gao N, Janssens K page 89 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Polycyclodextrin and carbon nanotubes as composite for tyrosinase immobilization and its superior electrocatalytic activity towards butylparaben an endocrine disruptor”. Rather JA, Pilehvar S, De Wael K, Journal of nanoscience and nanotechnology 15, 3365 (2015). http://doi.org/10.1166/JNN.2015.10210
Abstract: We developed a protocol for the immobilization of tyrosinase (Tyr) on the composite of polycyclodextrin polymer (CDP) and carbon nanotubes for the detection of an endocrine disruptor, i.e., butylparaben (BP). The formation of the CDP polymer was characterized by UV-Vis spectrophotometry. The conducting film of cross-linked CDP and carbon nanotubes, displays excellent matrix capabilities for Tyr immobilization. The host-guest chemical reaction ability of CD and the ππ stacking interaction assure the bioactivity of Tyr towards butylparaben. The developed biosensor was characterized electrochemically by electrochemical impedance spectroscopy. The enzyme-substrate kinetic parameters such as the apparent Michaelis-Menten constant (K M app) was measured under saturated substrate concentration. The determination of butylparaben was carried out by using square wave voltammetry over the concentration range of 2.1 to 35.4 μM with a detection limit of 0.1 μM. The fabricated biosensor was successfully applied in real-life cosmetic samples with good recovery ranging from 98.5 to 102.8%.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 3
DOI: 10.1166/JNN.2015.10210
|
“Polydopamine-gelatin as universal cell-interactive coating for methacrylate-based medical device packaging materials : when surface chemistry overrules substrate bulk properties”. Van de Walle E, Van Nieuwenhove I, Vanderleyden E, Declercq H, Gellynck K, Schaubroeck D, Ottevaere H, Thienpont H, De Vos WH, Cornelissen M, Van Vlierberghe S, Dubruel P, Biomacromolecules 17, 56 (2016). http://doi.org/10.1021/ACS.BIOMAC.5B01094
Abstract: Despite its widespread application in the fields of ophthalmology, orthopedics and dentistry and the stringent need for polymer packagings that induce in vivo tissue integration, the full potential of poly(methyl methacrylate) (PMMA) and its derivatives as medical device packaging material has not been explored yet. We therefore elaborated on the development of a universal coating for methacrylate-based materials which ideally should reveal cell-interactivity irrespective of the polymer substrate bulk properties. Within this perspective, the present work reports on the UV-induced synthesis of PMMA and its more flexible poly(ethyleneglycol) (PEG)-based derivative (PMMAPEG) and its subsequent surface decoration using polydopamine (PDA) as well as PDA combined with gelatin B (Gel B). Successful application of both layers was confirmed by multiple surface characterization techniques. The cell interactivity of the materials was studied by performing live-dead assays and immunostainings of the cytoskeletal components of fibroblasts. It can be concluded that only the combination of PDA and Gel B yields materials posessing similar cell interactivities, irrespective of the physicochemical properties of the underlying substrate. The proposed coating outperforms both the PDA functionalized and the pristine polymer surfaces. A universal cell-interactive coating for methacrylate-based medical device packaging materials has thus been realized.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ACS.BIOMAC.5B01094
|
“Populieren en hun bacteriën : een sanering hoeft niet altijd duur en ingrijpend te zijn”. Compernolle T, Van Passel S, Lebbe L, Vangronsveld J, Thewys T, Nieuwsbrief milieu &, economie 24, 15 (2010)
Keywords: A3 Journal article; Economics
|
Tavernier S, op de Beeck W, Ghekiere J-P, Van Tendeloo G (1996) Positively charged toner for use in electrostatography : US5532097 : 07/02/1996
Keywords: Patent; Electron microscopy for materials research (EMAT)
|
“Possibilities of energy-resolved X-ray radiography for the investigation of paintings”. Cabal Rodríguez AE, Leyva Pernia D, Schalm O, van Espen PJM, Analytical and bioanalytical chemistry 402, 1471 (2012). http://doi.org/10.1007/S00216-011-5230-X
Abstract: X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-011-5230-X
|
“Potential fields of self intersecting Gielis curves for modeling and generalized blending techniques”. Fougerolle Y, Truchetet F, Gielis J, Modeling In Mathematics 2, 67 (2017). http://doi.org/10.2991/978-94-6239-261-8_6
Abstract: The definition of Gielis curves allows for the representation of self intersecting curves. The analysis and the understanding of these representations is of major interest for the analytical representation of sectors bounded by multiple subsets of curves (or surfaces), as this occurs for instance in many natural objects. We present a construction scheme based on R-functions to build signed potential fields with guaranteed differential properties, such that their zero-set corresponds to the outer, the inner envelop, or combined subparts of the curve. Our framework is designed to allow for the definition of composed domains built upon Boolean operations between several distinct objects or some subpart of self-intersecting curves, but also provides a representation for soft blending techniques in which the traditional Boolean union and intersection become special cases of linear combinations between the objects' potential fields. Finally, by establishing a connection between R-functions and Lame curves, we can extend the domain of the p parameter within the R-p-function from the set of the even positive numbers to the real numbers strictly greater than 1, i.e. p is an element of]1, +infinity[.
Keywords: P1 Proceeding; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.2991/978-94-6239-261-8_6
|
“Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples”. Daems D, van Nuijs ALN, Covaci A, Hamidi-Asl E, Van Camp G, Nagels LJ, Biomedical chromatography 29, 1124 (2015). http://doi.org/10.1002/BMC.3400
Abstract: The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3ngmL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25ngmL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright (c) 2014 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
DOI: 10.1002/BMC.3400
|
De Wael K, Nagels L, Van Camp G (2013) Potentiometric sensors and method for measuring intermolecular interactions
Keywords: Patent; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Lu Q (2024) Precipitation behavior and heat resistance properties of Al-Cu-Mg-Ag-(Si) alloy. VIII, 212 p
Abstract: With the rapid increase in the speed of new-generation aerospace vehicles, conventional heat-resistant aluminum alloys cannot meet the long-term service of the equipment. Therefore, the development of new high-strength heat-resistant aluminum alloys is of great strategic for the sustainable and high-quality development of industries. Al-Cu-Mg-Ag alloy is an age-hardenable heat-resistant aluminum alloy and has high strength and heat resistance. The addition of alloying elements such as Si and Sc to Al-Cu-Mg-Ag alloy introduces a competitive relationship among the σ-Al5Cu6Mg2, θ′-Al2Cu, and Ω phases. Therefore, a systematic investigation of precipitation behavior and heat resistance of Al-Cu-Mg-Ag-(Si) is essential for guiding the design of high-strength heat-resistant aluminum alloys. Combined characterization testing methods such as scanning electron microscopy, transmission electron microscopy, atom probe tomography, microhardness testing, and tensile testing with simulation calculation methods such as calculation of phase diagram, first-principles calculations, and Ab initio molecular dynamics, the effects of heat treatment processes and element content on the precipitation behavior, mechanical properties, and heat resistance of Al-Cu-Mg-Ag-(Si) alloys were systematically investigated. Furthermore, a multiple interface segregation structure was constructed at the θ′/Al interface, and a new Al-Cu-Mg-Ag-Si-Sc alloy with synergistically improved strength and heat resistance was developed. The main conclusions are as follows: (1) Based on the Kampmann-Wagner-Numerical theory, the relationship between the coarsening rate of the Ω phase and the aging process was analyzed, revealing for the first time that the critical size of Ω phase ( ) under thermal exposure temperature was the key factor determining the coarsening rate of Ω phase during long time thermal exposure heat treatment. After artificial ageing, when the size of Ω phase was smaller than the critical size , the dissolution of smaller Ω phase leaded to a rapid decrease in the number density of Ω phases, thereby reducing the heat resistance of the alloy. When the size of Ω phase was greater than or equal to the critical size , the coarsening rate of Ω phase was consistent, but a larger initial size would result in a larger final size after long-term thermal exposure. Therefore, the closer the size of Ω phase in the alloy is to the critical size under heat exposure temperature, the better the heat resistance of the alloy. (2) A concept of constructing a multiple interface segregation structure at the precipitate/matrix interface was proposed, and based on this concept, a multiple interface segregation structure containing the C/L-AlMgSiCu interfacial phase, newly discovered χ-AgMg interfacial phase, and Sc segregation layer was successfully constructed at the θ′/Al interface. The existence of the multiple interface segregation structure ensured that the designed Al-Cu-Mg-Ag-Si-Sc alloy maintains a yield strength of 400 MPa after thermal exposure at 200 C for 100 h, with a strength retention rate of 97%, creating a new record for the synergistic improvement of strength and heat resistance in aluminum alloys. In addition, combining transmission electron microscopy ex-situ/in-situ characterization with first-principles calculations, it is shown that the χ-AgMg interface phase will be destroyed due to the diffusion of the outer Ag layer during thermal exposure, and gradually dissolve into the matrix, but it can still delay the coarsening behavior of θ′-Al2Cu phase. (3) The criteria for determining whether Ω phase can precipitate are updated in Al-Cu-Mg-Ag-Si alloys with low Mg/Si ratio based on phase diagram thermodynamic calculations and multi-scale structural characterization. When W(Mg)/W(Si) > 1.4 and X(Ag)/X(Mgexcess) > 1, Ω phase can precipitate in Al-Cu-Mg-Ag-Si alloys, where X(Mgexcess) represents the atomic percentage of residual Mg elements after the formation of the AlMgSiCu quaternary precipitate phase C/L phase in the supersaturated solid solution, and the W(Mg) is the mass fraction of Mg in the supersaturated solid solution before artificial ageing. (4) The effects of alloy element content on precipitation behavior and heat resistance of Al-Cu-Mg-Ag-Si alloys were systematically analyzed. Critical conditions for the precipitation of σ-Al5Cu6Mg2 and Ω phase in Al-Cu-Mg-Ag-Si alloys are revealed. Based on calculation of phase diagram results, the conditions for precipitating σ-Al5Cu6Mg2 phase in the alloy are: ① W(Mg)/W(Si) > 1.8; ② W(Cu) > 2.7W(Mg) – 5W(Si). When W(Mg)/W(Si) < 1.8, the alloy is mainly precipitated with C/L/Q′-AlMgSiCu. When W(Cu) < 2.7W(Mg) – 5W(Si), the alloy will generate GPB zone. In addition, W(Ag)/W(Si) > 4 is the critical condition which the Ω phase can the main precipitates in Al-Cu-Mg-Ag-Si alloys. Furthermore, the correlation between precipitate types and heat resistance was summarized, showing that Al-Cu-Mg-Ag-(Si) alloys with Ω phase as the main strengthening phase are more suitable for the preparation of structures with short service time but high temperature, while Al-Cu-Mg-Ag-(Si) alloys with low Mg content and multiple segregation structures are more suitable for structures requiring long-term service at medium to high temperatures. This study, for the first time, combines calculation of phase diagram with multi-scale microstructure characterization, systematically unraveling the effects of element content on precipitation behavior, strength, and heat resistance of Al-Cu-Mg-Ag-(Si) alloys. In addition, a concept of constructing a multiple interface segregation structure at the precipitate/matrix interface was proposed to synergistically improve alloy strength and heat resistance. This work provides theoretical guidance for optimizing the composition and processing of Al-Cu-Mg-Ag-(Si) alloy and regulating the microstructure. Furthermore, it also offers new ideas and theoretical guidance for the development of novel high-strength heat-resistant alloys in other systems.
Keywords: Doctoral thesis; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
|
“Precise gamma ray measurement of the radial distribution of a cracking catalyst at diluted concentrations in a glass riser”. Dantas CC, Dos Santos VA, Melo ACBA, Van Grieken R, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 251, 201 (2006). http://doi.org/10.1016/J.NIMB.2006.05.009
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2006.05.009
|
“Precision magnetometry on a submicron scale”. Geim AK, Lok JGS, Maan JC, Dubonos SV, Li XQ, Peeters FM, Nazarov YV, , 3311 (1996)
Keywords: P3 Proceeding; Condensed Matter Theory (CMT)
|
“Preconcentration and XRF-determination of heavy metals in hair from Sudanese populations”. Eltayeb MAH, Van Grieken RE, Journal of radioanalytical and nuclear chemistry 131, 331 (1989). http://doi.org/10.1007/BF02060598
Abstract: Energy-dispersive X-ray fluorescence analysis was applied for the analysis of hair. The hair samples were digested in a mixture of nitric and perchloric acid and the heavy metals were precipitated with ammonium pyrrolidine dithiocarbamate. The accuracy, precision and recovery of the method for the elements Fe, Ni, Cu, Zn and Pb were evaluated through the analysis of a standard hair sample. The procedure was applied to the analysis of hair from an occupationally exposed group of Sudanese workers and a control group. The hair of the exposed group showed a range of 80550 ppm Fe, 612 ppm Cu, 57190 ppm Zn and 703700 ppm Pb, while that of the control group had a range of 60310 ppm Fe, 722 ppm Cu, 89170 ppm Zn and 317 ppm Pb.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02060598
|
“Preconcentration methods for the analysis of liquid samples by X-ray fluorescence techniques”. Marguí, E, Van Grieken R, Fontàs C, Hidalgo M, Queralt I, Applied spectroscopy reviews 45, 179 (2010). http://doi.org/10.1080/05704920903584198
Abstract: This article gives an overview of the state-of-the-art of multi-element and single-element preconcentration procedures prior to X-ray fluorescence (XRF) analysis of liquid samples. Many of these preconcentration methods were developed long ago and the purpose of this review is to present some new efficient variations of these methods and new techniques extending the possibilities of XRF for liquid solutions analysis. In addition, trends and future perspectives in this domain are also commented on and discussed in the last section of the review.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/05704920903584198
|
“Preconcentration methods for the analysis of water by X-ray spectrometric techniques”. Van Grieken R, Analytica chimica acta 143, 3 (1982). http://doi.org/10.1016/S0003-2670(01)95486-8
Abstract: All published procedures for multi-element preconcentration of trace elements, prior to x-ray fluorescence analysis of water, are reviewed and critically evaluated. Most preconcentration methods applied to the determination of single elements in water are also listed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95486-8
|
“Preconcentration of precious metals by tellurium sulphide fire-assay followed by instrumental neutron activation analysis”. Shazali I, Van 't dack L, Gijbels R, , 29 (1988)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Predicting longevity of iron permeable reactive barriers using multiple iron deactivation models”. Carniato L, Schoups G, Seuntjens P, Van Nooten T, Simons Q, Bastiaens L, Journal of contaminant hydrology 142, 93 (2012). http://doi.org/10.1016/J.JCONHYD.2012.08.012
Abstract: In this study we investigate the model uncertainties involved in predicting long-term permeable reactive barrier (PRB) remediation efficiency based on a lab-scale column experiment under accelerated flow conditions. A PRB consisting of 20% iron and 80% sand was simulated in a laboratory-scale column and contaminated groundwater was pumped into the column for approximately 1 year at an average groundwater velocity of 3.7E – 1 m d(-1). Dissolved contaminants (PCE. TCE, cis-DCE, trans-DCE and VC) and inorganic (Ca2+, Fe2+, TIC and pH) concentrations were measured in groundwater sampled at different times and at eight different distances along the column. These measurements were used to calibrate a multi-component reactive transport model, which subsequently provided predictions of long-term PRB efficiency under reduced flow conditions (i.e., groundwater velocity of 1.4E -3 m d(-1)), representative of a field site of interest in this study. Iron reactive surface reduction due to mineral precipitation and iron dissolution was simulated using four different models. All models were able to reasonably well reproduce the column experiment measurements, whereas the extrapolated long-term efficiency under different flow rates was significantly different between the different models. These results highlight significant model uncertainties associated with extrapolating long-term PRB performance based on lab-scale column experiments. These uncertainties should be accounted for at the PRB design phase, and may be reduced by independent experiments and field observations aimed at a better understanding of reactive surface deactivation mechanisms in iron PRBs. (C) 2012 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1016/J.JCONHYD.2012.08.012
|
“Predicting saturated hydraulic conductivity in a sandy grassland using proximally sensed apparent electrical conductivity”. Rezaei M, Saey T, Seuntjens P, Joris I, Boenne W, Van Meirvenne M, Cornelis W, Journal of applied geophysics 126, 35 (2016). http://doi.org/10.1016/J.JAPPGEO.2016.01.010
Abstract: Finding a correspondence between soil hydraulic properties, such as saturated hydraulic conductivity (Ks) and apparent electrical conductivity (ECa) as an easily measurable parameter, may be a way forward to estimate the spatial distribution of hydraulic properties at the field scale. In this study, the spatial distributions of Ks, of soil ECa measured by a DUALEM-21S sensor and of soil physical properties were investigated in a sandy grassland. To predict field scale Ks, the statistical relationship between co-located soil Ks, and EMI-ECa was evaluated. Results demonstrated the large spatial variability of all studied properties with Ks being the most variable one (CV = 86.21%) followed by ECa (CV >= 53.77%). A significant negative correlation was found between In-transformed Ks and ECa (r = 0.83; P <= 0.01) at two depths of exploration (0-50 and 0-100 cm). This site specific relation between In Ks and ECa was used to predict saturated hydraulic conductivity over 0-50 cm depth for the whole field. The empirical relation was validated using an independent dataset of measured Ks. The statistical results demonstrate the robustness of this empirical relation with mean estimation error MEE = 0.46 (cm h(-1)), root-mean-square estimation errors RMSEE = 0.74 (cm h(-1)), coefficient of determination r(2) = 0.67 and coefficient of model efficiency Ce = 0.64. The relationship was then used to produce a detailed map of Ks for the whole field. The result will allow model predictions of spatially distributed water content in view of irrigation management. (C) 2016 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1016/J.JAPPGEO.2016.01.010
|
“Prediction of Mα/L&alpha, intensity ratios and the use in the spectra evaluation”. Trincavelli J, Montoro S, Van Grieken R, van Espen P, (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
“Prediction of the optical characteristics and analytical qualities of an X-ray fluorescence microprobe at the European Synchrotron Radiation Facility (Grenoble)”. van Langevelde F, Janssens KH, Adams FC, Vis RD, Nuclear instruments and methods in physics research : A: accelerators, spectrometers, detectors and associated equipment 317, 383 (1992). http://doi.org/10.1016/0168-9002(92)90632-E
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0168-9002(92)90632-E
|
“Preface”. Van Grieken R, Janssens K page vii-viii (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Preface”. Janssens K, Van Grieken R page xxvii-xxviii (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Preliminary evaluation of micro-Raman spectrometry for the characterization of individual aerosol particles”. Potgieter-Vermaak SS, Van Grieken R, Applied spectroscopy 60, 39 (2006). http://doi.org/10.1366/000370206775382848
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/000370206775382848
|
“Preliminary experiment of total reflection x-ray fluorescence using two glancing x-ray beams excitation”. Tsuji K, Sato T, Wagatsuma K, Claes M, Van Grieken R, The review of scientific instruments 70, 1621 (1999). http://doi.org/10.1063/1.1149687
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1063/1.1149687
|
“Preliminary experiments on grazing-exit electron probe microanalysis (GE-EPMA)”. Tsuji K, Spolnik Z, Wagatsuma K, Nullens R, Van Grieken RE, , 119 (1999)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|