|
“Optimization of operating parameters for inductively coupled plasma mass spectrometry : a computational study”. Aghaei M, Lindner H, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 76, 56 (2012). http://doi.org/10.1016/j.sab.2012.06.006
Abstract: An inductively coupled plasma, connected to a mass spectrometer interface, is computationally investigated. The effect of pressure behind the sampler, injector gas flow rate, auxiliary gas flow rate, and applied power is studied. There seems to be an optimum range of injector gas flow rate for each setup which guaranties the presence and also a proper length of the central channel in the torch. Moreover, our modeling results show that for any specific purpose, it is possible to control that either only the central gas flow passes through the sampler orifice or that it is accompanied by the auxiliary gas flow. It was also found that depending on geometry, the variation of outgoing gas flow rate is much less than the variation of the injector gas flow rate and this causes a slightly higher pressure inside the torch. The general effect of increasing the applied power is a rise in the plasma temperature, which results in a higher ionization in the coil region. However, the negative effect is reducing the length of the cool central channel which is important to transfer the sample substances to the sampler. Using a proper applied power can enhance the efficiency of the system. Indeed, by changing the gas path lines, the power can control which flow (i.e., only from injector gas or also from the auxiliary gas) goes to the sampler orifice. Finally, as also reported from experiments in literature, the pressure behind the sampler has no dramatic effect on the plasma characteristics.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 18
DOI: 10.1016/j.sab.2012.06.006
|
|
|
“Behavior of the sputtered copper atoms, ions and excited species in a radio-frequency and direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 55, 279 (2000). http://doi.org/10.1016/S0584-8547(00)00142-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 17
DOI: 10.1016/S0584-8547(00)00142-7
|
|
|
“Comparison of modeling calculations with experimental results for direct current glow discharge optical emission spectrometry”. Bogaerts A, Wilken L, Hoffmann V, Gijbels R, Wetzig K, Spectrochimica acta: part B : atomic spectroscopy 56, 551 (2001). http://doi.org/10.1016/S0584-8547(01)00220-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 16
DOI: 10.1016/S0584-8547(01)00220-8
|
|
|
“Comparison of modeling calculations with experimental results for rf glow discharge optical emission spectrometry”. Bogaerts A, Wilken L, Hoffmann V, Gijbels R, Wetzig K, Spectrochimica acta: part B : atomic spectroscopy 57, 109 (2002). http://doi.org/10.1016/S0584-8547(01)00357-3
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 14
DOI: 10.1016/S0584-8547(01)00357-3
|
|
|
“Computer simulations of crater profiles in glow discharge optical emission spectrometry: comparison with experiments and investigation of the underlying mechanisms”. Bogaerts A, Verscharen W, Steers E, Spectrochimica acta: part B : atomic spectroscopy 59, 1403 (2004). http://doi.org/10.1016/j.sab.2004.06.005
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 14
DOI: 10.1016/j.sab.2004.06.005
|
|
|
“Comparison of argon and neon as discharge gases in a direct current glow discharge: a mathematical simulation”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 52, 553 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 13
|
|
|
“The influence of laser-particle interaction in laser induced breakdown spectroscopy and laser ablation inductively coupled plasma spectrometry”. Lindner H, Loper KH, Hahn DW, Niemax K, Spectrochimica acta: part B : atomic spectroscopy 66, 179 (2011). http://doi.org/10.1016/j.sab.2011.01.002
Abstract: Particles produced by previous laser shots may have significant influence on the analytical signal in laser-induced breakdown spectroscopy (LIBS) and laser ablation inductively coupled plasma (LA-ICP) spectrometry if they remain close to the position of laser sampling. The effects of these particles on the laser-induced breakdown event are demonstrated in several ways. LIBS-experiments were conducted in an ablation cell at atmospheric conditions in argon or air applying a dual-pulse arrangement with orthogonal pre-pulse, i.e., plasma breakdown in a gas generated by a focussed laser beam parallel and close to the sample surface followed by a delayed crossing laser pulse in orthogonal direction which actually ablates material from the sample and produces the LIBS plasma. The optical emission of the LIBS plasma as well as the absorption of the pre-pulse laser was measured. In the presence of particles in the focus of the pre-pulse laser, the plasma breakdown is affected and more energy of the pre-pulse laser is absorbed than without particles. As a result, the analyte line emission from the LIBS plasma of the second laser is enhanced. It is assumed that the enhancement is not only due to an increase of mass ablated by the second laser but also to better atomization and excitation conditions favored by a reduced gas density in the pre-pulse plasma. Higher laser pulse frequencies increase the probability of particle-laser interaction and, therefore, reduce the shot-to-shot line intensity variation as compared to lower particle loadings in the cell. Additional experiments using an aerosol chamber were performed to further quantify the laser absorption by the plasma in dependence on time both with and without the presence of particles. The overall implication of laser-particle interactions for LIBS and LA-ICP-MS/OES are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 12
DOI: 10.1016/j.sab.2011.01.002
|
|
|
“Comparison between a radio-frequency and direct current glow discharge in argon by a hybrid Monte Carlo-fluid model for electrons, argon ions and fast argon atoms”. Bogaerts A, Gijbels R, Goedheer W, Spectrochimica acta: part B : atomic spectroscopy 54, 1335 (1999). http://doi.org/10.1016/S0584-8547(99)00080-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 11
DOI: 10.1016/S0584-8547(99)00080-4
|
|
|
“Monte Carlo analysis of the electron thermalization process in the afterglow of a microsecond dc pulsed glow discharge”. Martín A, Bordel N, Pereiro R, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 63, 1274 (2008). http://doi.org/10.1016/j.sab.2008.09.012
Abstract: A Monte Carlo model is utilized for studying the behavior of electrons in the afterglow of an analytical microsecond dc pulsed glow discharge. This model uses several quantities as input data, such as electric field and potential, ion flux at the cathode, the fast argon ion and atom impact ionization rates, slow electron density, the electrical characterization of the pulse (voltage and current profiles) and temperature profile. These quantities were obtained by earlier Monte Carlo fluid calculations for a pulsed discharge. Our goal is to study the behavior of the so-called Monte Carlo electrons (i.e., those electrons created at the cathode or by ionization collisions in the plasma which are followed by using the Monte Carlo model) from their origin to the moment when they are absorbed at the cell walls or when they have lost their energy by collisions (being transferred to the group of slow electrons) in the afterglow of the pulsed discharge. The thermalization of the electrons is a phenomenon where the electron-electron Coulomb collisions acquire a special importance. Indeed, in the afterglow the cross sections of the other electron reactions taken into account in the model are very low, because of the very low electron energy. We study the electron energy distributions at several times during and after the pulse and at several positions in the plasma cell, focusing on the thermalization and on the behavior of the electrons in the afterglow. Also, the time evolution of the rates of the various collision processes, the average electron energy, the densities of Monte Carlo and slow electrons and the ionization degree are investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 9
DOI: 10.1016/j.sab.2008.09.012
|
|
|
“mu-X-ray fluorescence and mu-X-ray diffraction investigations of sediment from the Ruprechtov nuclear waste disposal natural analog site”. Denecke MA, de Nolf W, Janssens K, Brendebach B, Falkenberg G, Noseck U, Rothkirch A, Spectrochimica acta: part B : atomic spectroscopy 63, 484 (2008). http://doi.org/10.1016/J.SAB.2008.01.001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2008.01.001
|
|
|
“Possibilities and limitations of synchrotron X-ray powder diffraction with double crystal and double multilayer monochromators for microscopic speciation studies”. de Nolf W, Jaroszewicz J, Terzano R, Lind OC, Salbu B, Vekemans B, Janssens K, Falkenberg G, Spectrochimica acta: part B : atomic spectroscopy 64, 775 (2009). http://doi.org/10.1016/J.SAB.2009.06.003
Abstract: The performance of a combined microbeam X-ray fluorescence/X-ray powder diffraction (XRF/XRPD) measurement station at Hamburger Synchrotronstrahlungslabor (HASYLAB) Beamline L is discussed in comparison to that at European Synchrotron Radiation Facility (ESRF) ID18F/ID22. The angular resolution in the X-ray diffractograms is documented when different combinations of X-ray source, optics and X-ray diffraction detectors are employed. Typical angular resolution values in the range 0.30.5° are obtained at the bending magnet source when a pink beam form of excitation is employed. A similar setup at European Synchrotron Radiation Facility beamlines ID18F and ID22 allows to reach angular resolution values of 0.10.15°. In order to document the possibilities and limitations for speciation of metals in environmental materials by means of Hamburger Synchrotronstrahlungslabor Beamline L X-ray fluorescence/X-ray powder diffraction setup, two case studies are discussed, one involved in the identification of the crystal phases in which heavy metals such as chromium, iron, barium and lead are present in polluted soils of an industrial site (Val Basento, Italy) and another involved in the speciation of uranium in depleted uranium particles (Ceja Mountains, Kosovo). In the former case, the angular resolution is sufficient to allow identification of most crystalline phases present while in the latter case, it is necessary to dispose of an angular resolution of ca. 0.2° to distinguish between different forms of oxidized uranium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2009.06.003
|
|
|
“Colloquium Spectroscopicum Internationale 34, Antwerp (Belgium), 4-9 September 2005: preface”. Bogaerts A, Janssens K, van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 61, 373 (2006). http://doi.org/10.1016/j.sab.2006.04.011
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 2
DOI: 10.1016/j.sab.2006.04.011
|
|
|
“Computer simulations of sample chambers for laser ablation-inductively coupled plasma spectrometry”. Bleiner D, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 62, 155 (2007). http://doi.org/10.1016/j.sab.2007.02.010
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
DOI: 10.1016/j.sab.2007.02.010
|
|
|
“Laser-induced excitation mechanisms and phase transitions in spectrochemical analysis &ndash, Review of the fundamentals”. Vanraes P, Bogaerts A, Spectrochimica Acta Part B-Atomic Spectroscopy 179, 106091 (2021). http://doi.org/10.1016/j.sab.2021.106091
Abstract: Nowadays, lasers are commonly applied in spectrochemical analysis methods, for sampling, plasma formation or a combination of both. Despite the numerous investigations that have been performed on these applications, the underlying processes are still insufficiently understood. In order to fasten progress in the field and in honor of the lifework of professor Rick Russo, we here provide a brief overview of the fundamental mechanisms in lasermatter interaction as proposed in literature, and throw the spotlight on some aspects that have not received much attention yet. For an organized discussion, we choose laser ablation, laser desorption and the associated gaseous plasma formation as the central processes in this perspective article, based on a classification of the laserbased spectrochemical analysis techniques and the corresponding laser-matter interaction regimes. First, we put the looking glass over the excitation and thermalization mechanisms in the laser-irradiated condensed phase, for which we propose the so-called multi-plasma model. This novel model can be understood as an extension of the well-known two-temperature model, featuring multiple thermodynamic dimensions, each of which corresponds to a quasi-particle type. Next, the focus is placed on the mass transfer and ionization mechanisms, after which we shortly highlight the possible role of anisotropic and magnetic effects in the laser-excited material. We hope this perspective article motivates more fundamental research on laser-matter interaction, as a continuation of the lifework of Rick Russo.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
DOI: 10.1016/j.sab.2021.106091
|
|
|
“Change in silica sources in Roman and post Roman glass”. Aerts A, Janssens K, Velde B, Dijkman W, Spectrochimica acta: part B : atomic spectroscopy 58, 659 (2003). http://doi.org/10.1016/S0584-8547(02)00287-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(02)00287-2
|
|
|
“Characterization of the main causes of deterioration of grisaille paint layers in 19th C. stained-glass windows by J.-B. Capronnier”. Schalm O, Janssens K, Caen J, Spectrochimica acta: part B : atomic spectroscopy 58, 589 (2003). http://doi.org/10.1016/S0584-8547(02)00282-3
Abstract: Twenty-seven glass fragments containing dark coloured grisaille paint layers of different qualities were collected from ten windows of the cathedral St. Michael & St. Gudule in Brussels (Belgium). The windows were made by J.-B. Capronnier (18141891) and cover the period between 1843 and 1878. The samples were cross-sectioned and examined in an electron microscope. Grisaille paint layers are not homogeneous and therefore, it is not meaningful to characterize them in terms of their average composition. Instead, parameters such as granularity, the number of residual gas bubbles per running millimetre of paint, the type of pigments, and the thickness of the paint layer were used to characterize them. The microscopic morphology allows a classification of the grisaille paint layers in four groups, every group associated with a quality level. Moreover, the main causes of the accelerated degradation of some of these paint layers could be explained. The classification made it possible to distinguish two periods in the work of Capronnier: (1) the early period (18431848) is characterized by the presence of either single granular paint layers or of double-layered systems consisting of a granular paint layer on top of a well-melted paint layer. The granular grisaille paint layers tend to pulverize; (2) the later period (18481878) is characterized by the presence of only well-vitrified paint layers. No sign of deterioration was found on the well-vitrified paint layers.
Keywords: A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(02)00282-3
|
|
|
“A flexible and accurate quantification algorithm for EPXMA based on thin-film element yields”. Schalm O, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 58, 669 (2003). http://doi.org/10.1016/S0584-8547(02)00290-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(02)00290-2
|
|
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 1: theory”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 75 (2000). http://doi.org/10.1016/S0584-8547(99)00172-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00172-X
|
|
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 2: application”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 1039 (2000). http://doi.org/10.1016/S0584-8547(00)00220-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00220-2
|
|
|
“Localised and non-destructive analysis of metallic artefacts from ancient Egypt by means of a compact μ-XRF instrument”. Vittiglio G, Janssens K, Adams F, Oost A, Spectrochimica acta: part B : atomic spectroscopy 54, 1697 (1999). http://doi.org/10.1016/S0584-8547(99)00100-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00100-7
|
|
|
“Monte Carlo simulation of X-ray fluorescence spectra: part 4: photon scattering at high X-ray energies”. Vincze L, Janssens K, Vekemans B, Adams F, Spectrochimica acta: part B : atomic spectroscopy , 1711 (1999). http://doi.org/10.1016/S0584-8547(99)00094-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00094-4
|
|
|
“The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials”. Kempenaers L, Vincze L, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 55, 651 (2000). http://doi.org/10.1016/S0584-8547(00)00207-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00207-X
|
|