“Computer simulations of a dielectric barrier discharge used for analytical spectrometry”. Martens T, Bogaerts A, Brok W, van Dijk J, Analytical and bioanalytical chemistry 388, 1583 (2007). http://doi.org/10.1007/s00216-007-1269-0
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.431
Times cited: 28
DOI: 10.1007/s00216-007-1269-0
|
“Computer simulations of plasmabiomolecule and plasmatissue interactions for a better insight in plasma medicine”. Neyts EC, Yusupov M, Verlackt CC, Bogaerts A, Journal of physics: D: applied physics 47, 293001 (2014). http://doi.org/10.1088/0022-3727/47/29/293001
Abstract: Plasma medicine is a rapidly evolving multidisciplinary field at the intersection of chemistry, biochemistry, physics, biology, medicine and bioengineering. It holds great potential in medical, health care, dentistry, surgical, food treatment and other applications. This multidisciplinary nature and variety of possible applications come along with an inherent and intrinsic complexity. Advancing plasma medicine to the stage that it becomes an everyday tool in its respective fields requires a fundamental understanding of the basic processes, which is lacking so far. However, some major advances have already been made through detailed experiments over the last 15 years. Complementary, computer simulations may provide insight that is difficultif not impossibleto obtain through experiments. In this review, we aim to provide an overview of the various simulations that have been carried out in the context of plasma medicine so far, or that are relevant for plasma medicine. We focus our attention mostly on atomistic simulations dealing with plasmabiomolecule interactions. We also provide a perspective and tentative list of opportunities for future modelling studies that are likely to further advance the field.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 28
DOI: 10.1088/0022-3727/47/29/293001
|
“Detailed numerical investigation of a DC sputter magnetron”. Kolev I, Bogaerts A, IEEE transactions on plasma science 34, 886 (2006). http://doi.org/10.1109/TPS.2006.875843
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 28
DOI: 10.1109/TPS.2006.875843
|
“The influence of impurities on the performance of the dielectric barrier discharge”. Martens T, Bogaerts A, Brok WJM, van Dijk J, Applied physics letters 96, 091501 (2010). http://doi.org/10.1063/1.3327800
Abstract: In this letter, we investigate the effect of various levels of nitrogen impurity on the electrical performance of an atmospheric pressure dielectric barrier discharge in helium. We illustrate the different current profiles that are obtained, which exhibit one or more discharge pulses per half cycle and evaluate their performance in ionizing the discharge and dissipating the power. It is shown that flat and broad current profiles perform the best in ionizing the discharge and use the least amount of power per generated charged particle.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.411
Times cited: 28
DOI: 10.1063/1.3327800
|
“Multi-element model for the simulation of inductively coupled plasmas : effects of helium addition to the central gas stream”. Lindner H, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 66, 421 (2011). http://doi.org/10.1016/j.sab.2011.04.007
Abstract: A model for an atmospheric pressure inductively coupled plasma (ICP) is developed which allows rather easy extension to a variable number of species and ionisation degrees. This encompasses an easy calculation of transport parameters for mixtures, ionisation and heat capacity. The ICP is modeled in an axisymmetric geometry, taking into account the gas streaming into a flowing ambient gas. A mixture of argon and helium is applied in the injector gas stream as it is often done in laser ablation ICP spectrometry. The results show a strong influence of the added helium on the center of the ICP, which is important for chemical analysis. The length of the central channel is significantly increased and the temperature inside is significantly higher than in the case of pure argon. This means that higher gas volume flow rates can be applied by addition of helium compared to the use of pure argon. This has the advantage that the gas velocity in the transport system towards the ICP can be increased, which allows shorter washout-times. Consequently, shorter measurement times can be achieved, e.g. for spatial mapping analyses in laser ablation ICP spectrometry. Furthermore, the higher temperature and the longer effective plasma length will increase the maximum size of droplets or particles injected into the ICP that are completely evaporated at the detection site. Thus, we expect an increase of the analytical performance of the ICP by helium addition to the injector gas.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 28
DOI: 10.1016/j.sab.2011.04.007
|
“Routes to increase the conversion and the energy efficiency in the splitting of CO2by a dielectric barrier discharge”. Ozkan A, Bogaerts A, Reniers F, Journal of physics: D: applied physics 50, 084004 (2017). http://doi.org/10.1088/1361-6463/aa562c
Abstract: Here, we present routes to increase CO2 conversion into CO using an atmospheric pressure dielectric-barrier discharge. The change in conversion as a function of simple plasma parameters, such as power, flow rate, but also frequency, on-and-off power pulse, thickness and the chemical nature of the dielectric, wall and gas temperature, are described. By means of an in-depth electrical characterization of the discharge (effective plasma voltage, dielectric voltage, plasma current, number and lifetime of the microdischarges), combined with infrared analysis of the walls of the reactor, optical emission spectroscopy for the gas temperature, and mass spectrometry for the CO2 conversion, we propose a global interpretation of the effect of all the experimental parameters on the conversion and efficiency of the reaction.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 28
DOI: 10.1088/1361-6463/aa562c
|
“Modeling Plasma-based CO2and CH4Conversion in Mixtures with N2, O2, and H2O: The Bigger Plasma Chemistry Picture”. Wang W, Snoeckx R, Zhang X, Cha MS, Bogaerts A, The journal of physical chemistry: C : nanomaterials and interfaces 122, 8704 (2018). http://doi.org/10.1021/acs.jpcc.7b10619
Abstract: Because of the unique properties of plasma technology, its use in gas conversion applications is gaining significant interest around the globe. Plasma-based CO2 and CH4 conversion has become a major research area. Many investigations have already been performed regarding the single-component gases, that is, CO2 splitting and CH4 reforming, as well as for two-component mixtures, that is, dry reforming of methane
(CO2/CH4), partial oxidation of methane (CH4/O2), artificial photosynthesis (CO2/H2O), CO2 hydrogenation (CO2/H2), and even first steps toward the influence of N2 impurities have been taken, that is, CO2/N2 and CH4/N2. In this Feature Article we briefly discuss the advances made in literature for these different steps from a plasma chemistry modeling point of view. Subsequently, we present a comprehensive plasma chemistry set, combining the knowledge gathered in this field so far and supported with extensive experimental data. This set can be used for chemical kinetics plasma modeling for all possible combinations of CO2, CH4, N2, O2, and H2O to investigate the bigger picture of the underlying plasmachemical pathways for these mixtures in a dielectric barrier discharge plasma. This is extremely valuable
for the optimization of existing plasma-based CO2 conversion and CH4 reforming processes as well as for investigating the influence of N2, O2, and H2O on these processes and even to support plasma-based multireforming processes.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.536
Times cited: 28
DOI: 10.1021/acs.jpcc.7b10619
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 85, 670 (2013). http://doi.org/10.1021/ac3031459
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 29
DOI: 10.1021/ac3031459
|
“Fluid modelling of an atmospheric pressure dielectric barrier discharge in cylindrical geometry”. Petrović, D, Martens T, van Dijk J, Brok WJM, Bogaerts A, Journal of physics: D: applied physics 42, 205206 (2009). http://doi.org/10.1088/0022-3727/42/20/205206
Abstract: A numerical parameter study has been performed for a cylindrical atmospheric pressure dielectric barrier discharge (DBD) in helium with nitrogen impurities using a two-dimensional time-dependent fluid model. The calculated electric currents and gap voltages as a function of time for a given applied potential are presented, as well as the number densities of the various plasma species. This study shows that for the geometry under consideration the applied voltage parameters have a large impact on the electric current profiles and that the discharge current is always determined by the electron and ion conduction currents while the displacement current is nearly negligible. A relative broadening of the current profiles (compared with the duration of the half cycle of the applied voltage) with an increase in the applied frequency is obtained. Nearly sinusoidal current wave forms, usually typical for radio frequency DBDs, are observed while still operating at the frequencies of tens of kilohertz. For the setup under investigation, the Townsend mode of the DBD is observed in the entire range of applied voltage amplitudes and frequencies. It is shown that the average power density dissipated in the discharge increases with rising applied voltage and frequency. An increase in applied voltage frequency leads to an increase in the electron density and a decrease in electron energy, while increasing the voltage amplitude has the opposite effect.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 29
DOI: 10.1088/0022-3727/42/20/205206
|
“The glow discharge: an exciting plasma”. Bogaerts A, Journal of analytical atomic spectrometry 14, 1375 (1999). http://doi.org/10.1039/a900772e
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 29
DOI: 10.1039/a900772e
|
“The importance of an external circuit in a particle-in-cell/Monte Carlo collisions model for a direct current planar magnetron”. Bultinck E, Kolev I, Bogaerts A, Depla D, Journal of applied physics 103, 013309 (2008). http://doi.org/10.1063/1.2828155
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 29
DOI: 10.1063/1.2828155
|
“In-situ chemical trapping of oxygen in the splitting of carbon dioxide by plasma”. Aerts R, Snoeckx R, Bogaerts A, Plasma processes and polymers 11, 985 (2014). http://doi.org/10.1002/ppap.201400091
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.846
Times cited: 29
DOI: 10.1002/ppap.201400091
|
“Influence of electron recapture by the cathode upon the discharge characteristics in dc planar magnetrons”. Kolev I, Bogaerts A, Gijbels R, Physical review : E : statistical physics, plasmas, fluids, and related interdisciplinary topics 72, 056402 (2005). http://doi.org/10.1103/PhysRevE.72.056402
Abstract: In dc magnetrons the electrons emitted from the cathode may return there due to the applied magnetic field. When that happens, they can be recaptured or reflected back into the discharge, depending on the value of the reflection coefficient (RC). A 2d3v (two-dimensional in coordinate and three-dimensional in velocity space) particle-in-cellMonte Carlo model, including an external circuit, is developed to determine the role of the electron recapture in the discharge processes. The detailed discharge structure as a function of RC for two pressures (4 and 25mtorr) is studied. The importance of electron recapture is clearly manifested, especially at low pressures. The results indicate that the discharge characteristics are dramatically changed with varying RC between 0 and 1. Thus, the electron recapture at the cathode appears to be a significant mechanism in magnetron discharges and RC a very important parameter in their correct quantitative description that should be dealt with cautiously.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 29
DOI: 10.1103/PhysRevE.72.056402
|
“Investigation of growth mechanisms of clusters in a silane discharge with the use of a fluid model”. de Bleecker K, Bogaerts A, Goedheer W, Gijbels R, IEEE transactions on plasma science 32, 691 (2004). http://doi.org/10.1109/TPS.2004.826095
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 29
DOI: 10.1109/TPS.2004.826095
|
“Numerical analysis of the effect of nitrogen and oxygen admixtures on the chemistry of an argon plasma jet operating at atmospheric pressure”. Van Gaens W, Iseni S, Schmidt-Bleker A, Weltmann K-D, Reuter S, Bogaerts A, New journal of physics 17, 033003 (2015). http://doi.org/10.1088/1367-2630/17/3/033003
Abstract: In this paper we study the cold atmospheric pressure plasma jet, called kinpen, operating in Ar with different admixture fractions up to 1% pure , and + . Moreover, the device is operating with a gas curtain of dry air. The absolute net production rates of the biologically active ozone () and nitrogen dioxide () species are measured in the far effluent by quantum cascade laser absorption spectroscopy in the mid-infrared. Additionally, a zero-dimensional semi-empirical reaction kinetics model is used to calculate the net production rates of these reactive molecules, which are compared to the experimental data. The latter model is applied throughout the entire plasma jet, starting already within the device itself. Very good qualitative and even quantitative agreement between the calculated and measured data is demonstrated. The numerical model thus yields very useful information about the chemical pathways of both the and the generation. It is shown that the production of these species can be manipulated by up to one order of magnitude by varying the amount of admixture or the admixture type, since this affects the electron kinetics significantly at these low concentration levels.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.786
Times cited: 29
DOI: 10.1088/1367-2630/17/3/033003
|
“Comparison of electrostatic and electromagnetic simulations for very high frequency plasmas”. Zhang Y-R, Xu X, Zhao S-X, Bogaerts A, Wang Y-N, Physics of plasmas 17, 113512 (2010). http://doi.org/10.1063/1.3519515
Abstract: A two-dimensional self-consistent fluid model combined with the full set of Maxwell equations is developed to investigate an argon capacitively coupled plasma, focusing on the electromagnetic effects on the discharge characteristics at various discharge conditions. The results indicate that there exist distinct differences in plasma characteristics calculated with the so-called electrostatic model (i.e., without taking into account the electromagnetic effects) and the electromagnetic model (which includes the electromagnetic effects), especially at very high frequencies. Indeed, when the excitation source is in the high frequency regime and the electromagnetic effects are taken into account, the plasma density increases significantly and meanwhile the ionization rate evolves to a very different distribution when the electromagnetic effects are dominant. Furthermore, the dependence of the plasma characteristics on the voltage and pressure is also investigated, at constant frequency. It is observed that when the voltage is low, the difference between these two models becomes more obvious than at higher voltages. As the pressure increases, the plasma density profiles obtained from the electromagnetic model smoothly shift from edge-peaked over uniform to a broad maximum in the center. In addition, the edge effect becomes less pronounced with increasing frequency and pressure, and the skin effect rather than the standing-wave effect becomes dominant when the voltage is high.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.115
Times cited: 30
DOI: 10.1063/1.3519515
|
“Space charge corrected electron emission from an aluminum surface under non-equilibrium conditions”. Wendelen W, Mueller BY, Autrique D, Rethfeld B, Bogaerts A, Journal of applied physics 111, 113110 (2012). http://doi.org/10.1063/1.4729071
Abstract: A theoretical study has been conducted of ultrashort pulsed laser induced electron emission from an aluminum surface. Electron emission fluxes retrieved from the commonly employed Fowler-DuBridge theory were compared to fluxes based on a laser-induced non-equilibrium electron distribution. As a result, the two-and three-photon photoelectron emission parameters for the Fowler-DuBridge theory have been approximated. We observe that at regimes where photoemission is important, laser-induced electron emission evolves in a more smooth manner than predicted by the Fowler-DuBridge theory. The importance of the actual electron distribution decreases at higher laser fluences, whereas the contribution of thermionic emission increases. Furthermore, the influence of a space charge effect on electron emission was evaluated by a one dimensional particle-in-cell model. Depending on the fluences, the space charge reduces the electron emission by several orders of magnitude. The influence of the electron emission flux profiles on the effective electron emission was found to be negligible. However, a non-equilibrium electron velocity distribution increases the effective electron emission significantly. Our results show that it is essential to consider the non-equilibrium electron distribution as well as the space charge effect for the description of laser-induced photoemission. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4729071]
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 30
DOI: 10.1063/1.4729071
|
“Grain size tuning of nanocrystalline chemical vapor deposited diamond by continuous electrical bias growth : experimental and theoretical study”. Mortet V, Zhang L, Eckert M, D'Haen J, Soltani A, Moreau M, Troadec D, Neyts E, De Jaeger JC, Verbeeck J, Bogaerts A, Van Tendeloo G, Haenen K, Wagner P, Physica status solidi : A : applications and materials science 209, 1675 (2012). http://doi.org/10.1002/pssa.201200581
Abstract: In this work, a detailed structural and spectroscopic study of nanocrystalline diamond (NCD) thin films grown by a continuous bias assisted CVD growth technique is reported. This technique allows the tuning of grain size and phase purity in the deposited material. The crystalline properties of the films are characterized by SEM, TEM, EELS, and Raman spectroscopy. A clear improvement of the crystalline structure of the nanograined diamond film is observed for low negative bias voltages, while high bias voltages lead to thin films consisting of diamond grains of only ∼10 nm nanometer in size, showing remarkable similarities with so-called ultrananocrystalline diamond. These layers arecharacterized by an increasing amount of sp2-bonded carbon content of the matrix in which the diamond grains are embedded. Classical molecular dynamics simulations support the observed experimental data, giving insight in the underlying mechanism for the observed increase in deposition rate with bias voltage. Furthermore, a high atomic concentration of hydrogen has been determined in these films. Finally, Raman scattering analyses confirm that the Raman line observed at ∼1150 cm−1 cannot be attributed to trans-poly-acetylene, which continues to be reported in literature, reassigning it to a deformation mode of CHx bonds in NCD.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.775
Times cited: 31
DOI: 10.1002/pssa.201200581
|
“Hybrid model for a cylindrical hollow cathode glow discharge and comparison with experiments”. Baguer N, Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 57, 311 (2002). http://doi.org/10.1016/S0584-8547(01)00385-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 31
DOI: 10.1016/S0584-8547(01)00385-8
|
“Laser-induced plasmas from the ablation of metallic targets: the problem of the onset temperature, and insights on the expansion dynamics”. Bleiner D, Bogaerts A, Belloni F, Nassisi V, Journal of applied physics 101, 083301 (2007). http://doi.org/10.1063/1.2721410
Abstract: Laser-induced plasmas are transient systems rapidly aging in few nanoseconds of evolution. Time-of-flight spectrometry allowed studying initial plasma characteristics based on frozen translational degrees of freedom, hence overcoming intrinsic limitations of optical spectroscopy. Experimental ion velocity distributions were reconstructed as developed during the longitudinal plasma expansion. The obtained onset plasma temperatures are in the range of similar to 18-45 eV depending on the ablated metals. Also the ion angular spreads were found to be a function of ablated metal, e.g., the narrowest for Fe, the broadest for Al, due to different collisional coupling in the plasma population. (c) 2007 American Institute of Physics.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 31
DOI: 10.1063/1.2721410
|
“Modeling of the formation and transport of nanoparticles in silane plasmas”. de Bleecker K, Bogaerts A, Goedheer W, Physical review : E : statistical physics, plasmas, fluids, and related interdisciplinary topics 70, 056407 (2004). http://doi.org/10.1103/PhysRevE.70.056407
Abstract: The behavior of nanoparticles in a low-pressure silane discharge is studied with the use of a self-consistent one-dimensional fluid model. Nanoparticles of a given (prescribed) radius are formed in the discharge by the incorporation of a dust growth mechanism, i.e., by including a step in which large anions (typically Si12H−25), produced in successive chemical reactions of anions with silane molecules, are transformed into particles. Typically a few thousand anions are used for one nanoparticle. The resulting particle density and the charge on the particles are calculated with an iterative method. While the spatial distribution and the charge of the particles are influenced by the plasma, the presence of the nanoparticles will in turn influence the plasma properties. Several simulations with different particle radii are performed. The resulting density profile of the dust will greatly depend on the particle size, as it reacts to the shift of the balance of the different forces acting on the particles.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 31
DOI: 10.1103/PhysRevE.70.056407
|
“The role of mass removal mechanisms in the onset of ns-laser induced plasma formation”. Autrique D, Clair G, L'Hermite D, Alexiades V, Bogaerts A, Rethfeld B, Journal of applied physics 114, 023301 (2013). http://doi.org/10.1063/1.4812577
Abstract: The present study focuses on the role of mass removal mechanisms in ns-laser ablation. A copper sample is placed in argon, initially set at standard pressure and temperature. Calculations are performed for a 6 ns laser pulse with a wavelength of 532 nm and laser fluences up to 10 J/cm2. The transient behavior in and above the copper target is described by a hydrodynamic model. Transmission profiles and ablation depths are compared with experimental results and similar trends are found. Our calculations reveal an interesting self-inhibiting mechanism: volumetric mass removal in the supercritical region triggers plasma shielding and therefore stops proceeding. This self-limiting process indicates that volumetric mass removal does not necessarily result in large ablation depths.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 31
DOI: 10.1063/1.4812577
|
“Simulation of an Ar/Cl2 inductively coupled plasma: study of the effect of bias, power and pressure and comparison with experiments”. Tinck S, Boullart W, Bogaerts A, Journal of physics: D: applied physics 41, 065207 (2008). http://doi.org/10.1088/0022-3727/41/6/065207
Abstract: A hybrid model, called the hybrid plasma equipment model, was used to study Ar/Cl(2) inductively coupled plasmas used for the etching of Si. The effects of substrate bias, source power and gas pressure on the plasma characteristics and on the fluxes and energies of plasma species bombarding the substrate were observed. A comparison with experimentally measured etch rates was made to investigate how the etch process is influenced and which plasma species mainly account for the etch process. First, the general plasma characteristics are investigated at the following operating conditions: 10% Ar 90% Cl(2) gas mixture, 5mTorr total gas pressure, 100 sccm gas flow rate, 250W source power, -200V dc bias at the substrate electrode and an operating frequency of 13.56MHz applied to the coil and to the substrate electrode. Subsequently, the pressure is varied from 5 to 80mTorr, the substrate bias from -100 to -300V and the source power from 250 to 1000W. Increasing the total gas pressure results in a decrease of the etch rate and a less anisotropic flux to the substrate due to more collisions of the ions in the sheath. Increasing the substrate bias has an effect on the energy of the ions bombarding the substrate and to a lesser extent on the magnitude of the ion flux. When source power is increased, it was found that, not the energy, but the magnitude of the ion flux is increased. The etch rate was more influenced by a variation of the substrate bias than by a variation of the source power, at these operating conditions. These results suggest that the etch process is mainly affected by the energy of the ions bombarding the substrate and the magnitude of the ion flux, and to a lesser extent by the magnitude of the radical flux.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 31
DOI: 10.1088/0022-3727/41/6/065207
|
“Unprecedented shape selectivity in hydrogenation of triacylglycerol molecules with Pt/ZSM-5 zeolite”. Philippaerts A, Paulussen S, Breesch A, Turner S, Lebedev OI, Van Tendeloo G, Sels B, Jacobs P, Angewandte Chemie: international edition in English 50, 3947 (2011). http://doi.org/10.1002/anie.201007513
Abstract: Well tuned: ZSM-5 with platinum nanoparticles preferably hydrogenates trans fatty acids over cis isomers in model triacylglycerols for geometric reasons. The central fatty acid chain reacts faster, pointing to pore mouth adsorption in a tuning fork conformation (see picture). This conformation induces stepwise hydrogenation, resulting in fast removal of the unstable central triene, while formation of saturated chains is limited.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 11.994
Times cited: 31
DOI: 10.1002/anie.201007513
|
“Atomic spectroscopy”. Bings NH, Bogaerts A, Broekaert JAC, Analytical chemistry 76, 3313 (2004). http://doi.org/10.1021/ac040052x
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 32
DOI: 10.1021/ac040052x
|
“A comparative study for the inactivation of multidrug resistance bacteria using dielectric barrier discharge and nano-second pulsed plasma”. Hoon Park J, Kumar N, Hoon Park D, Yusupov M, Neyts EC, Verlackt CCW, Bogaerts A, Ho Kang M, Sup Uhm H, Ha Choi E, Attri P;, Scientific reports 5, 13849 (2015). http://doi.org/10.1038/srep13849
Abstract: Bacteria can be inactivated through various physical and chemical means, and these have always been the focus of extensive research. To further improve the methodology for these ends, two types of plasma systems were investigated: nano-second pulsed plasma (NPP) as liquid discharge plasma and an Argon gas-feeding dielectric barrier discharge (Ar-DBD) as a form of surface plasma. To understand the sterilizing action of these two different plasma sources, we performed experiments with Staphylococcus aureus (S. aureus) bacteria (wild type) and multidrug resistant bacteria (Penicillum-resistant, Methicillin-resistant and Gentamicin-resistant). We observed that both plasma sources can inactivate both the wild type and multidrug-resistant bacteria to a good extent. Moreover, we observed a change in the surface morphology, gene expression and β-lactamase activity. Furthermore, we used X-ray photoelectron spectroscopy to investigate the variation in functional groups (C-H/C-C, C-OH and C=O) of the peptidoglycan (PG) resulting from exposure to plasma species. To obtain atomic scale insight in the plasma-cell interactions and support our experimental observations, we have performed molecular dynamics simulations to study the effects of plasma species, such as OH, H2O2, O, O3, as well as O2 and H2O, on the dissociation/formation of above mentioned functional groups in PG.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.259
Times cited: 32
DOI: 10.1038/srep13849
|
“Computer modelling of magnetron discharges”. Bogaerts A, Bultinck E, Kolev I, Schwaederlé, L, van Aeken K, Buyle G, Depla D, Journal of physics: D: applied physics 42, 194018 (2009). http://doi.org/10.1088/0022-3727/42/19/194018
Abstract: In this paper, some modelling approaches to describe direct current (dc) magnetron discharges developed in our research groups will be presented, including an analytical model, Monte Carlo simulations for the electrons and for the sputtered atoms, a hybrid Monte Carlo-fluid model and particle-in-cell-Monte Carlo collision simulations. The strengths and limitations of the various modelling approaches will be explained, and some characteristic simulation results will be illustrated. Furthermore, some other simulation methods related to the magnetron device will be briefly explained, more specifically for calculating the magnetic field distribution inside the discharge, and for describing the (reactive) sputtering.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 32
DOI: 10.1088/0022-3727/42/19/194018
|
“Phase explosion in atmospheric pressure infrared laser ablation from water-rich targets”. Chen Z, Bogaerts A, Vertes A, Applied physics letters 89, 041503 (2006). http://doi.org/10.1063/1.2243961
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.411
Times cited: 32
DOI: 10.1063/1.2243961
|
“Comparison of calculated and measured optical emission intensities in a direct current argon-copper glow discharge”. Bogaerts A, Donko Z, Kutasi K, Bano G, Pinhao N, Pinheiro M, Spectrochimica acta: part B : atomic spectroscopy 55, 1465 (2000). http://doi.org/10.1016/S0584-8547(00)00253-6
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 33
DOI: 10.1016/S0584-8547(00)00253-6
|
“Effect of small amounts of hydrogen added to argon glow discharges: hybrid Monte-Carlo-fluid model”. Bogaerts A, Gijbels R, Physical review : E : statistical, nonlinear, and soft matter physics 65, 056402 (2002). http://doi.org/10.1103/PhysRevE.65.056402
Abstract: A hybrid Monte Carlofluid modeling network is developed for an argon-hydrogen mixture, to predict the effect of small amounts of hydrogen added to a dc argon glow discharge. The species considered in the model include the Ar gas atoms, electrons, Ar+ ions and fast Ar atoms, ArH+, H+, H+2 and H+3 ions, and H atoms and H2 molecules, as well as Ar metastable atoms, sputtered Cu atoms, and the corresponding Cu+ ions. Sixty-five reactions between these species are incorporated in the model. The effect of hydrogen on various calculation results is investigated, such as the species densities, the relative role of different production and loss processes for the various species, the cathode sputtering rate and contributions by different bombarding species, and the dissociation degree of H2 and the ionization degree of Ar and Cu. The calculation results are presented and discussed for 1% H2 addition, and comparison is also made with a pure argon discharge and with only 0.1% H2 addition.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 33
DOI: 10.1103/PhysRevE.65.056402
|