|
“Advantages of combined mu-XRF and mu-XRD for phase characterization of Ti-B-C ceramics compared with conventional X-ray diffraction”. Jaroszewicz J, de Nolf W, Janssens K, Michalski A, Falkenberg G, Analytical and bioanalytical chemistry 391, 1129 (2008). http://doi.org/10.1007/S00216-008-2097-6
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 7
DOI: 10.1007/S00216-008-2097-6
|
|
|
“mu-X-ray fluorescence and mu-X-ray diffraction investigations of sediment from the Ruprechtov nuclear waste disposal natural analog site”. Denecke MA, de Nolf W, Janssens K, Brendebach B, Falkenberg G, Noseck U, Rothkirch A, Spectrochimica acta: part B : atomic spectroscopy 63, 484 (2008). http://doi.org/10.1016/J.SAB.2008.01.001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2008.01.001
|
|
|
“Possibilities and limitations of synchrotron X-ray powder diffraction with double crystal and double multilayer monochromators for microscopic speciation studies”. de Nolf W, Jaroszewicz J, Terzano R, Lind OC, Salbu B, Vekemans B, Janssens K, Falkenberg G, Spectrochimica acta: part B : atomic spectroscopy 64, 775 (2009). http://doi.org/10.1016/J.SAB.2009.06.003
Abstract: The performance of a combined microbeam X-ray fluorescence/X-ray powder diffraction (XRF/XRPD) measurement station at Hamburger Synchrotronstrahlungslabor (HASYLAB) Beamline L is discussed in comparison to that at European Synchrotron Radiation Facility (ESRF) ID18F/ID22. The angular resolution in the X-ray diffractograms is documented when different combinations of X-ray source, optics and X-ray diffraction detectors are employed. Typical angular resolution values in the range 0.30.5° are obtained at the bending magnet source when a pink beam form of excitation is employed. A similar setup at European Synchrotron Radiation Facility beamlines ID18F and ID22 allows to reach angular resolution values of 0.10.15°. In order to document the possibilities and limitations for speciation of metals in environmental materials by means of Hamburger Synchrotronstrahlungslabor Beamline L X-ray fluorescence/X-ray powder diffraction setup, two case studies are discussed, one involved in the identification of the crystal phases in which heavy metals such as chromium, iron, barium and lead are present in polluted soils of an industrial site (Val Basento, Italy) and another involved in the speciation of uranium in depleted uranium particles (Ceja Mountains, Kosovo). In the former case, the angular resolution is sufficient to allow identification of most crystalline phases present while in the latter case, it is necessary to dispose of an angular resolution of ca. 0.2° to distinguish between different forms of oxidized uranium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2009.06.003
|
|
|
“Simplex Volume Maximization (SiVM): a matrix factorization algorithm with non-negative constrains and low computing demands for the interpretation of full spectral X-ray fluorescence imaging data”. Alfeld M, Wahabzada M, Bauckhage C, Kersting K, van der Snickt G, Noble P, Janssens K, Wellenreuther G, Falkenberg G, Microchemical journal 132, 179 (2017). http://doi.org/10.1016/J.MICROC.2017.02.001
Abstract: Technological progress allows for an ever-faster acquisition of hyperspectral data, challenging the users to keep up with interpreting the recorded data. Matrix factorization, the representation of data sets by bases (or loads) and coefficient (or score) images is long used to support the interpretation of complex data sets. We propose in this publication Simplex Volume Maximization (SiVM) for the analysis of X-ray fluorescence (XRF) imaging data sets. SiVM selects archetypical data points that represents the data set and thus provides easily understandable bases, preserves the non-negative character of XRF data sets and has low demands concerning computing resources. We apply SiVM on an XRF data set of Hans Memling's Portrait of a man from the Lespinette family from the collection of the Mauritshuis (The Hague, NL) and discuss capabilities and shortcomings of SiVM. (C) 2017 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.034
Times cited: 8
DOI: 10.1016/J.MICROC.2017.02.001
|
|
|
“The use of full-field XRF for simultaneous elemental mapping”. Alfeld M, Janssens K, Sasov A, Liu X, Kostenko A, Rickers-Appel K, Falkenberg G, , 111 (2010). http://doi.org/10.1063/1.3399236
Abstract: The characteristics of a Full-Field X-ray Fluorescence (FF-XRF) set-up for element-specific imaging, installed at the HASYLAB synchrotron radiation source, were determined. A lateral resolution of 10 μm and limits of detection in the percentage range were found. Further potential developments in CCDs available for FF-XRF are discussed and the use of polycapillary lenses as image transfer optics is illustrated in some explorative experiments.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 8
DOI: 10.1063/1.3399236
|
|
|
“Combined computed nanotomography and nanoscopic x-ray fluorescence imaging of cobalt nanoparticles in caenorhabditis elegans”. Cagno S, Brede DA, Nuyts G, Vanmeert F, Pacureanu A, Tucoulou R, Cloetens P, Falkenberg G, Janssens K, Salbu B, Lind OC, Analytical chemistry 89, 11435 (2017). http://doi.org/10.1021/ACS.ANALCHEM.7B02554
Abstract: Synchrotron radiation phase-contrast computed nanotomography (nano-CT) and two-and three-dimensional (2D and 3D) nanoscopic X-ray fluorescence (nano-XRF) were used to investigate the internal distribution of engineered-cobalt nanoparticles (Co NPs) in exposed individuals of the nematode Caenorhabditis elegans. Whole-nematodes and selected tissues and organs were 3D-rendered: anatomical 3D renderings with 50 nm voxel size enabled the visualization of spherical nanoparticle aggregates. with size tip to 200 nm within intact C. elegans. A 20 X 37 nm(2) high-brilliance beam was employed to obtain XRF elemental distribution maps of entire nematodes or anatomical details such as embryos, which could be compared with the CT data, These maps showed Co NPs to be predominantly present within the intestine and the epithelium, and they were not colocalized with Zn granules found in the lysosonie-containing vesicles or Fe agglomerates in the intestine. Iterated XRF scanning of a specimen at 0 degrees and 90 degrees angles suggested that NP aggregates were translocated into tissues outside of the intestinal lumen. Virtual-slicing by means of 2D XRF tomography, combined with holotomography, indicated presumable presence of individual NP aggregates inside the uterus and within embryos.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 13
DOI: 10.1021/ACS.ANALCHEM.7B02554
|
|
|
“Spatially resolved micro-X-ray fluorescence and micro-X-ray absorption fine structure study of a fractured granite bore core following a radiotracer experiment”. Denecke MA, Brendebach B, de Nolf W, Falkenberg G, Janssens K, Simon R, Spectrochimica acta: part B : atomic spectroscopy 64, 791 (2009). http://doi.org/10.1016/J.SAB.2009.05.025
Abstract: Spatially resolved X-ray absorption and fluorescence investigation with a micrometer-scale resolution on actinide-containing samples provide information necessary for safety assessment of nuclear waste disposal. In this paper one example of such an experiment is presented. This example entails neptunium speciation in a fractured granite bore core from the Swedish Äspö Hard Rock Laboratory following a radiotracer experiment using µ-XAFS and µ-XRF. In order to probe micro-volumes below the surface in the granite samples and thereby avoid potential changes in the Np speciation during cutting of the bore core, a confocal irradiationdetection geometry is employed. µ-XAFS results for a selected granite bore core cross section with ~ 3 nmol Np/g reveal that Np, originally introduced as Np(V) in the tracer cocktail, is present in the granite in its reduced Np(IV) form. The Np(IV) is often present as particles, tens of µm in size. Elemental distribution maps show the tracer Np to be located in fissures and permeable channels not larger than 100 µm. The Np distribution appears often correlated with Zn also present in some fissures. We observe small granite fissures containing Fe (presumably Fe(II)), where we do not detect any Np. It is feasible that inflowing Np(V) has a shorter residence time in large fractures, while in the smaller fissures migration is slower, leading to longer residence times, i.e., reaction times, where it is reduced to less soluble Np(IV) and becomes thereby immobilized.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 21
DOI: 10.1016/J.SAB.2009.05.025
|
|
|
“Suitability of polycapillary optics for focusing of monochromatic synchrotron radiation as used in trace level micro-XANES measurements”. Vincze L, Wei F, Proost K, Vekemans B, Janssens K, He Y, Yan Y, Falkenberg G, Journal of analytical atomic spectrometry 17, 177 (2002). http://doi.org/10.1039/B110210A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/B110210A
|
|
|
“Evidence for degradation of the chrome yellows in Van Gogh's sunflowers : a study using noninvasive in situ methods and synchrotron-radiation-based x-ray techniques”. Monico L, Janssens K, Hendriks E, Vanmeert F, van der Snickt G, Cotte M, Falkenberg G, Brunetti BG, Miliani C, Angewandte Chemie: international edition in English 54, 13923 (2015). http://doi.org/10.1002/ANIE.201505840
Abstract: This paper presents firm evidence for the chemical alteration of chrome yellow pigments in Van Gogh's Sunflowers (Van Gogh Museum, Amsterdam). Noninvasive in situ spectroscopic analysis at several spots on the painting, combined with synchrotron-radiation-based X-ray investigations of two microsamples, revealed the presence of different types of chrome yellow used by Van Gogh, including the lightfast PbCrO4 and the sulfur-rich PbCr1-xSxO4 (x approximate to 0.5) variety that is known for its high propensity to undergo photoinduced reduction. The products of this degradation process, i.e., Cr-III compounds, were found at the interface between the paint and the varnish. Selected locations of the painting with the highest risk of color modification by chemical deterioration of chrome yellow are identified, thus calling for careful monitoring in the future.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 11.994
Times cited: 24
DOI: 10.1002/ANIE.201505840
|
|
|
“Full spectral XANES imaging using the Maia detector array as a new tool for the study of the alteration process of chrome yellow pigments in paintings by Vincent van Gogh”. Monico L, Janssens K, Alfeld M, Cotte M, Vanmeert F, Ryan CG, Falkenberg G, Howard DL, Brunetti BG, Miliani C, Journal of analytical atomic spectrometry 30, 613 (2015). http://doi.org/10.1039/C4JA00419A
Abstract: A combination of synchrotron radiation (SR) micro X-ray fluorescence (m-XRF) and XRF mode X-ray absorption near edge structure (XANES) measurements at the Cr K-edge already allowed us to establish that the photo-reduction of chromates to Cr(III) compounds is the cause of darkening of chrome yellow pigments (PbCr1-xSxO4, 0 <= x <= 0.8) in a number of paintings by Vincent van Gogh and in corresponding artificially aged paint models. A silicon drift detector (SDD) was employed to record the Cr-K XRF radiation in these X-ray micro beam-based measurements. However, in view of the limited count rate capabilities and collection solid angle of a single device, m-XRF and m-XANES employing single element SDDs (or similar) are primarily suited for collection of spectral data from individual points. Additionally, collection of XRF maps via point-by-point scanning with relatively long dwell times per point is possible but is usually confined to small areas. The development of the 384 silicon-diode array Maia XRF detector has provided valuable solutions in terms of data acquisition rate, allowing for full spectral (FS) XANES imaging in XRF mode, i.e., where spectroscopic information is available at each pixel in the scanned map. In this paper, the possibilities of SR Cr K-edge FS-XANES imaging in XRF mode using the Maia detector are examined as a new data collection strategy to study the speciation and distribution of alteration products of lead chromate-based pigments in painting materials. The results collected from two micro-samples taken from two Van Gogh paintings and an aged paint model show the possibility to perform FS-XANES imaging in practical time frames (from several minutes to a few hours) by scanning regions of sample sizes of the same order (more than 500 mm). The sensitivity and capabilities of FS-XANES imaging in providing representative chemical speciation information at the microscale (spatial resolution from similar to 2 to 0.6 mm) over the entire scanned area are demonstrated by the identification of Cr(OH) 3, Cr(III) sulfates and/or Cr(III) organometallic compounds in the corresponding phase maps, as alteration products. Comparable Cr-speciation results were obtained by performing equivalent higher spatial resolution SR m-XRF/single-point m-XANES analysis using a more conventional SDD from smaller regions of interest of each sample. Thus, large-area XRF mode FS-XANES imaging (Maia detector) is here proposed as a valuable and complementary data collection strategy in relation to “ zoomed-in” high-resolution m-XRF mapping and single-point m-XANES analysis (SDD).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 28
DOI: 10.1039/C4JA00419A
|
|
|
“Characterization of a polycapillary lens for use in micro-XANES experiments”. Proost K, Vincze L, Janssens K, Gao N, Bulska E, Schreiner M, Falkenberg G, X-ray spectrometry 32, 215 (2003). http://doi.org/10.1002/XRS.635
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 50
DOI: 10.1002/XRS.635
|
|
|
“In vivo investigation of the distribution and the local speciation of selenium in Allium cepa L. by means of microscopic X-ray absorption near-edge structure spectroscopy and confocal microscopic X-ray fluorescence analysis”. Bulska E, Wysocka IA, Wierzbicka MH, Proost K, Janssens K, Falkenberg G, Analytical chemistry 78, 7616 (2006). http://doi.org/10.1021/AC060380S
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 56
DOI: 10.1021/AC060380S
|
|
|
“Combined use of synchrotron radiation based micro-X-ray fluorescence, micro-X-ray diffraction, micro-X-ray absorption near-edge, and micro-fourier transform infrared spectroscopies for revealing an alternative degradation pathway of the pigment cadmium yellow in a painting by Van Gogh”. van der Snickt G, Janssens K, Dik J, de Nolf W, Vanmeert F, Jaroszewicz J, Cotte M, Falkenberg G, Van der Loeff L, Analytical chemistry 84, 10221 (2012). http://doi.org/10.1021/AC3015627
Abstract: Over the past years a number of studies have described the instability of the pigment cadmium yellow (CdS). In a previous paper we have shown how cadmium sulfide on paintings by James Ensor oxidizes to CdSO4 center dot H2O. The degradation process gives rise to the fading of the bright yellow color and the formation of disfiguring white crystals that are present on the paint surface in approximately 50 mu m sized globular agglomerations. Here, we study cadmium yellow in the painting “Flowers in a blue vase” by Vincent van Gogh. This painting differs from the Ensor case in the fact that (a) a varnish was superimposed onto the degraded paint surface and (b) the CdS paint area is entirely covered with an opaque crust. The latter obscures the yellow color completely and thus presents a seemingly more advanced state of degradation. Analysis of a cross-sectioned and a crushed sample by combining scanning microscopic X-ray diffraction (mu-XRD), microscopic X-ray absorption near-edge spectroscopy (mu-XANES), microscopic X-ray fluorescence (mu-XRF) based chemical state mapping and scanning microscopic Fourier transform infrared (mu-FT-IR) spectrometry allowed unravelling the complex alteration pathway. Although no crystalline CdSO4 compounds were identified on the Van Gogh paint samples, we conclude that the observed degradation was initially caused by oxidation of the original CdS pigment, similar as for the previous Ensor case. However, due to the presence of an overlying varnish containing lead-based driers and oxalate ions, secondary reactions took place. In particular, it appears that upon the photoinduced oxidation of its sulfidic counterion, the Cd2+ ions reprecipitated at the paint/varnish interface after having formed a complex with oxalate ions that themselves are considered to be degradation products of the resin and/or oil in the varnish. The SO42- anions, for their part, found a suitable reaction partner in Pb2+ ions stemming from a dissolved lead-based siccative that was added to the varnish to promote its drying. The resulting opaque anglesite compound in the varnish, in combination with the underlying CdC2O4 layer at the paint/varnish interface, account for the orange-gray crust that is disfiguring the painting on a macroscopic level. In this way, the results presented in this paper demonstrate how, through a judicious combined use of several microanalytical methods with speciation capabilities, many new insights can be obtained from two minute, but highly complex and heterogeneous paint samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 59
DOI: 10.1021/AC3015627
|
|
|
“Assessing the origin and fate of CR, Ni, Cu, Zn, Ph, and V in industrial polluted soil by combined microspectroscopic techniques and bulk extraction methods”. Terzano R, Spagnuolo M, Vekemans B, de Nolf W, Janssens K, Falkenberg G, Ruggiero P, Environmental science &, technology 41, 6762 (2007). http://doi.org/10.1021/ES070260H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 61
DOI: 10.1021/ES070260H
|
|
|
“Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of spectromicroscopic methods : 3 : synthesis, characterization, and detection of different crystal forms of the chrome yellow pigment”. Monico L, Janssens K, Miliani C, Brunetti BG, Vagnini M, Vanmeert F, Falkenberg G, Abakumov A, Lu Y, Tian H, Verbeeck J, Radepont M, Cotte M, Hendriks E, Geldof M, van der Loeff L, Salvant J, Menu M;, Analytical chemistry 85, 860 (2013). http://doi.org/10.1021/ac302158b
Abstract: The painter, Vincent van Gogh, and some of his contemporaries frequently made use of the pigment chrome yellow that is known to show a tendency toward darkening. This pigment may correspond to various chemical compounds such as PbCrO4 and PbCr1-xSxO4, that may each be present in various crystallographic forms with different tendencies toward degradation. Investigations by X-ray diffraction (XRD), mid-Fourier Transform infrared (FTIR), and Raman instruments (benchtop and portable) and synchrotron radiation-based micro-XRD and X-ray absorption near edge structure spectroscopy performed on oil-paint models, prepared with in-house synthesized PbCrO4 and PbCr1-xSxO4, permitted us to characterize the spectroscopic features of the various forms. On the basis of these results, an extended study has been carried out on historic paint tubes and on embedded paint microsamples taken from yellow-orange/pale yellow areas of 12 Van Gogh paintings, demonstrating that Van Gogh effectively made use of different chrome yellow types. This conclusion was also confirmed by in situ mid-FTIR investigations on Van Goghs Portrait of Gauguin (Van Gogh Museum, Amsterdam).
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 79
DOI: 10.1021/ac302158b
|
|
|
“Confocal microscopic X-ray fluorescence at the HASYLAB microfocus beamline: characteristics and possibilities”. Janssens K, Proost K, Falkenberg G, Spectrochimica acta: part A: molecular and biomolecular spectroscopy 59, 1637 (2004). http://doi.org/10.1016/J.SAB.2004.07.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.536
Times cited: 102
DOI: 10.1016/J.SAB.2004.07.025
|
|