Li B (2012) Aharonov-Bohm effect in semiconductor quantum rings. Antwerpen
Keywords: Doctoral thesis; Condensed Matter Theory (CMT)
|
Kirilenko D (2012) Characterization of graphene by electron diffraction. Antwerpen
Keywords: Doctoral thesis; Electron microscopy for materials research (EMAT)
|
Leroux F (2012) Characterization of soft-hard matter composite materials by advanced transmission electron microscopy. Universiteit Antwerpen, EMAT, Antwerpen
Keywords: Doctoral thesis; Electron microscopy for materials research (EMAT)
|
Carrillo Nuñ,ez H (2012) Combining the modified local density approach with variational calculus : a flexible tandem for studying electron transport in nano-devices. Antwerpen
Keywords: Doctoral thesis; Condensed Matter Theory (CMT)
|
Lin N (2012) Dynamics of interacting clusters in low-dimensional superconductors. Antwerpen
Keywords: Doctoral thesis; Condensed Matter Theory (CMT)
|
Biermans E (2012) Electron tomography : from qualitative to quantitative. Antwerpen
Keywords: Doctoral thesis; Electron microscopy for materials research (EMAT)
|
Masir MR (2012) Electronic properties of graphene in inhomogeneous magnetic fields. Antwerpen
Keywords: Doctoral thesis; Condensed Matter Theory (CMT)
|
Dixit H (2012) First-principles electronic structure calculations of transparent conducting oxide materials. Antwerpen
Keywords: Doctoral thesis; Condensed Matter Theory (CMT)
|
Tan H (2012) From EELS to oxidation state mapping : an investigation into oxidation state mapping of transition metals with electron energy-loss spectroscopy. Antwerpen
Keywords: Doctoral thesis; Electron microscopy for materials research (EMAT)
|
“High-resolution visualization techniques : structural aspects”. Schryvers D, Van Aert S Springer, Berlin, page 135 (2012).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
“Investigation of the elementary mechanisms controlling dislocation/twin boundary interactions in fcc metals and alloys : from conventional to advanced TEM characterization”. Idrissi H, Schryvers D Formatex Research Center, S.l., page 1213 (2012).
Keywords: H2 Book chapter; Electron microscopy for materials research (EMAT)
|
“Modeling aspects of plasma-enhanced chemical vapor deposition of carbon-based materials”. Neyts E, Mao M, Eckert M, Bogaerts A CRC Press, Boca Raton, Fla, page 245 (2012).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
Heidari Mezerji H (2012) Quantitative electron tomography of nanoparticles. Antwerpen
Keywords: Doctoral thesis; Electron microscopy for materials research (EMAT)
|
“Recent results on characterization of detonation nanodiamonds”. Vlasov II, Turner S, Van Tendeloo G, Shiryaev AA Elsevier, Amsterdam, page 291 (2012).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
“Statistical parameter estimation theory : a tool for quantitative electron microscopy”. Van Aert S Wiley-VCH, Weinheim, page 281 (2012).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
Chen Y (2012) Superconductivity in nanofilms and nanocylinders. Antwerpen
Keywords: Doctoral thesis; Condensed Matter Theory (CMT)
|
Barbier M (2012) Transport properties of nanostructures and superlattices on single-layer and bilayer graphene. Antwerpen
Keywords: Doctoral thesis; Condensed Matter Theory (CMT)
|
Zhao H (2012) Vortex matter in superconductors with competing interactions : formation of vortex patterns and vortex dynamics. Antwerpen
Keywords: Doctoral thesis; Condensed Matter Theory (CMT)
|
De Vis K, Cagno S, Van Mol W, Schalm O, Janssens K, Caen J (2012) The decolourization of manganese-stained glass : the conversion reaction and evaluation of its effectiveness. 463–468
Keywords: P2 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Enzyme-gelatin electrochemical biosensors : scaling down”. De Wael K, De Belder S, Pilehar S, Van Steenberge G, Herrebout W, Heering HA, Biosensors 2, 101 (2012). http://doi.org/10.3390/BIOS2010101
Abstract: In this article we investigate the possibility of scaling down enzyme-gelatin modified electrodes by spin coating the enzyme-gelatin layer. Special attention is given to the electrochemical behavior of the selected enzymes inside the gelatin matrix. A glassy carbon electrode was used as a substrate to immobilize, in the first instance, horse heart cytochrome c (HHC) in a gelatin matrix. Both a drop dried and a spin coated layer was prepared. On scaling down, a transition from diffusion controlled reactions towards adsorption controlled reactions is observed. Compared to a drop dried electrode, a spin coated electrode showed a more stable electrochemical behavior. Next to HHC, we also incorporated catalase in a spin coated gelatin matrix immobilized on a glassy carbon electrode. By spincoating, highly uniform sub micrometer layers of biocompatible matrices can be constructed. A full electrochemical study and characterization of the modified surfaces has been carried out. It was clear that in the case of catalase, gluteraldehyde addition was needed to prevent leaking of the catalase from the gelatin matrix.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Molecular Spectroscopy (MolSpec)
DOI: 10.3390/BIOS2010101
|
Bruijnen Y, Caen JMA, Cagno S, Janssens K, et al. (2012) Getekend Jan R. : Jan Rombouts, een renaissancemeester herontdekt. 207 p
Keywords: ME2 Book as editor or co-editor; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Development and validation of optical detection methods to screen photocatalytic materials for soot oxidation”. Smits M, Tytgat T, Hauchecorne B, Lenaerts S, (2012)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
“Diatom silica-titania materials for photocatalytic air purification”. Van Eynde E, Lenaerts S page 240 (2012).
Keywords: H3 Book chapter; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
“Exhaust composition of a small diesel engine”. Smits M, Vanpachtenbeke F, Hauchecorne B, van Langenhove H, Demeestere K, Lenaerts S, Communications in agricultural and applied biological sciences 77, 85 (2012)
Keywords: A2 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
“Immobilisation of TiO2 into self-supporting photocatalytic foam : influence of acidity on porosity and light penetration”. Tytgat T, Lenaerts S, (2012)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
“Plasma assisted catalysis : an efficient and sustainable indoor air purification technology”. Van Wesenbeeck K, Hauchecorne B, Lenaerts S, (2012)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
“Acute changes in pulse pressure in relation to constituents of particulate air pollution in elderly persons”. Jacobs L, Buczyńska A, Walgraeve C, Potgieter-Vermaak S, Van Grieken R, et al, Environmental research 117, 60 (2012). http://doi.org/10.1016/J.ENVRES.2012.05.003
Abstract: An increased pulse pressure (difference between systolic and diastolic blood pressure) suggests aortic stiffening. The objective of this study was to examine the acute effects of both particulate matter (PM) mass and composition on blood pressure, among elderly persons. We carried out a panel study in persons living in elderly homes in Antwerp, Belgium. We recruited 88 non-smoking persons, 70% women with a mean age of 83 years (standard deviation: 5.2). Blood pressure was measured and a blood sample was collected on two time points, which were chosen so that there was an exposure contrast in ambient PM exposure. The elemental content of the collected indoor and outdoor PM2.5 (particulate matter with an aerodynamic diameter <2.5 μm) mass concentration was measured. Oxygenated polycyclic aromatic hydrocarbons (oxy-PAHs) on outdoor PM10 (particulate matter with an aerodynamic diameter <10 μm) were measured. Each interquartile range increase of 20.8 μg/m³ in 24-h mean outdoor PM2.5 was associated with an increase in pulse pressure of 4.0 mmHg (95% confidence interval: 1.86.2), in persons taking antihypertensive medication (n=57), but not in persons not using antihypertensive medication (n=31) (p for interaction: 0.02). Vanadium, iron and nickel contents of PM2.5 were significantly associated with systolic blood pressure and pulse pressure, among persons on antihypertensive medication. Similar results were found for indoor concentrations. Of the oxy-PAHs, chrysene-5,6-dione and benzo[a]pyrene-3,6-dione were significantly associated with increases in systolic blood pressure and pulse pressure. In elderly, pulse pressure was positively associated with acute increases in outdoor and indoor air pollution, among persons taking antihypertensive medication. These results might form a mechanistic pathway linking air pollution as a trigger of cardiovascular events.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ENVRES.2012.05.003
|
“Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks”. Margui E, Hidalgo M, Queralt I, van Meel K, Fontas C, Spectrochimica acta: part B : atomic spectroscopy 67, 17 (2012). http://doi.org/10.1016/J.SAB.2011.12.004
Abstract: We aimed to achieve improved instrumental sensitivity and detection limits for the analysis of several elements (Cu, Ni, Zn, Pb and Cd) in aqueous samples with energy dispersive X-ray fluorescence spectrometry (EDXRF). The metals were pre-concentrated from aqueous solutions using commercially available organic-based solid-phase extraction (SPE) disks functionalized with iminodiacetate groups. These thin-layer organic materials provide an ideal support for XRF analysis. The elements were collected on the SPE extraction disks using a simple filtration procedure (starting with 1 L of aqueous sample) that allows direct XRF measurements to be performed in the field (in situ). We evaluated the analytical possibilities and drawbacks of using this pre-concentration procedure in combination with the following XRF configurations: a handheld unit, a benchtop EDXRF system and a high-energy polarized-beam EDXRF instrument (HE-P-EDXRF). Using the HE-P-EDXRF system, the detection limits for all metals were more than one order of magnitude lower than those attained using handheld and benchtop EDXRF instrumentation. For the detection of metal concentrations higher than similar to 20 mu g/L, however, handheld or benchtop systems remain a very good option due to their extreme simplicity of operation and low-cost, compact design. We demonstrate the application of these methodologies, using the three equipment systems, to the analysis of trace concentrations of metals in different types of aqueous samples, including tap water and waste water. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2011.12.004
|
Bencs L, Horemans B, Van Grieken R, et al. (2012) Atmospheric deposition fluxes to the Belgian marine waters originating from ship emissions : SHIPFLUX : final report
Keywords: Minutes and reports; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Horemans B (2012) Chemical characterization of particulate air pollutants : case studies on indoor air quality, cultural heritage and the marine environment. 229 p
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|