|
“Patterns of iron storage in patients with severe renal failure”. van de Vijver FL, Vanheule AO, Verbueken AH, Van Grieken R, d'Haese P, Visser WJ, Bekaert AB, Buyssens N, de Broe ME, Contributions to nephrology 38, 153 (1984)
Keywords: A1 Journal article; Pharmacology. Therapy; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Penetration of atmospheric aerosols during collection in cellulose filters, studied by secondary ion mass spectrometry”. Rojas CM, Goossens D, Van Grieken R, Journal of aerosol science 20, 569 (1989). http://doi.org/10.1016/0021-8502(89)90103-1
Abstract: The penetration of aerosol particles in a Whatman-41 cellulose filter has been studied via the depth profiles of different elements present in the aerosol. Depth profiles were obtained by analyzing both fine and coarse fractions from a dichotomous sampler by secondary ion mass spectrometry. The fine particles had an aerodynamic diameter dae of less than 2.5 μm, whereas the coarse fraction had 2.5 ≤ dae ≤ 15 μm. Elements such as Al, Si, Ca, Ti and Fe were associated with coarse airborne particles, while S, Cl, Zn, and Br were more abundant in the fine fraction. Results showed that particle size plays an important role in the distribution of particulate matter throughout the filter. SiTi-containing particles were mostly deposited near the surface of the filter, and their profiles can be estimated using a polynomial function, whereas the profile of AlCaFe-containing particles can be approached by an exponential decay function. Elements associated with fine fraction aerosols mainly originating from combustion processes, can penetrate up to about 25% of the total filter thickness, and their profiles are better represented by a diffusion function.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0021-8502(89)90103-1
|
|
|
“Percentage selenium in consumed belgian feeding”. Robberecht H, Deelstra H, vanden Berghe D, Van Grieken R, Revue des fermentations et des industries alimentaires 37, 188 (1982)
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Performance and characteristics of two total-reflection X-ray fluorescence and a particle induced X-ray emission setup for aerosol analysis”. Injuk J, Van Grieken R, Klockenkämper R, von Bohlen A, Kump P, Spectrochimica acta: part B : atomic spectroscopy 52, 977 (1997). http://doi.org/10.1016/S0584-8547(97)00028-1
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(97)00028-1
|
|
|
“Performance of a new compact EDXRF spectrometer for aerosol analysis”. Samek L, Injuk J, van Espen P, Van Grieken R, X-ray spectrometry 31, 84 (2002). http://doi.org/10.1002/XRS.551
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.551
|
|
|
“Performance of total reflection and grazing emission X-ray fluorescence spectrometry for the determination of trace metals in drinking water in relation to other analytical techniques”. Hołynska B, Olko M, Ostachowicz B, Ostachowicz J, Wegrzynek D, Claes M, Van Grieken R, de Bokx P, Kump P, Necemer M, Fresenius' journal of analytical chemistry 362, 294 (1998). http://doi.org/10.1007/S002160051077
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051077
|
|
|
Brunekreef B, Janssen N A.H., de Hartog J J., Oldenwening M, Meliefste K, Hoek G, Lanki T, Timonen K L., Vallius M, Pekkanen J, Van Grieken R (2005) Personal, indoor, and outdoor exposures to PM2.5 and its components for groups of cardiovascular patients in Amsterdam and Helsinki
Keywords: Minutes and reports; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Perspectieven voor energie-dispersieve X-stralen fluorescentie bij de wateranalyse”. Vanderborght B, Van Grieken R, Hydrographica 1, 19 (1975)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Phosphorus, calcium and lead distribution in collagen in lead induced soft tissue calcification : an ultrastructural and X-ray microanalytical study”. Vandeputte DF, Jacob WA, Van Grieken RE, Matrix 10, 33 (1990). http://doi.org/10.1016/S0934-8832(11)80135-6
Abstract: Repeated intraperitoneal injections of lead acetate in rats caused a calcification of the skin of the abdomen near the site of the injections. In the lead-induced calcifications, electron dense collagen bundles could be observed. On the surface of the collagen fibrils, needle-like crystals were visible. With energy-dispersive X-ray analysis, phosphorus, calcium and lead were detected in the electron dense collagen bundles. X-ray maps of the P-Kα, Ca-Kα, and Pb-Lα plus Pb-Lβ lines showed an equivalent distribution along the collagen fibrils for phosphorus and calcium. The occurrence of the most electron dense areas in the STEM-image was comparable to the lead distribution. A good correlation existed between the structural and the elemental images of the same area. Although the medicinal use of preparations containing lead is no longer recommended, some are still prescribed. From our results we can conclude that they should not be applied to injured or inflamed skin.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0934-8832(11)80135-6
|
|
|
“Physico-chemical fate of chromium compounds in the lung sheep model”. Perrault G, Dufresne A, Strati G, McNeil M, Michaud D, Baril M, Bégin R, Labbé, J, Larivière P, Eeckhaoudt S, Van Grieken R, Journal of toxicology and environmental health 44, 247 (1995). http://doi.org/10.1080/15287399509531958
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/15287399509531958
|
|
|
“Pixe analysis of aerosol samples collected over the atlantic-ocean from a sailboat”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester WJ, Nuclear instruments and methods 181, 399 (1981). http://doi.org/10.1016/0029-554X(81)90640-6
Abstract: Size-fractionated aerosol samples, collected over the Atlantic Ocean, were analyzed for up to 20 elements by PIXE. Using a sailboat as sampling platform, duplicate samples were taken for two-day periods by means of battery operated 6-stage cascade impactors, positioned about 8 m above the sea surface. In the PIXE analysis of the fine particle stages (stages 3 to 5) a 5 times smaller beam size was used than for stages 1 and 2. This led to significant improvement in the detection limits for the former stages. The results from the duplicate impactor samples were normally in good agreement, indicating that the combined uncertainty of sampling and PIXE analysis was of the order of 20%. The precision of the PIXE analysis alone was investigated by rebombarding some samples six months after the first analysis. The trends with time of the fine particle sulfur and the coarse particle iron concentrations are discussed in some detail.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0029-554X(81)90640-6
|
|
|
“Platinum : environmental pollution and health effects”. Bencs L, Ravindra K, Van Grieken R page 580 (2011).
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Platinum group elements in the environment and their health risk”. Ravindra K, Bencs L, Van Grieken R, The science of the total environment 318, 1 (2004). http://doi.org/10.1016/S0048-9697(03)00372-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0048-9697(03)00372-3
|
|
|
“Polarized-beam high-energy EDXRF in geological samples”. Čevik U, Akbulut S, Makarovska Y, Van Grieken R, Spectroscopy letters 46, 36 (2013). http://doi.org/10.1080/00387010.2012.661015
Abstract: Certified reference materials (NIST 1645, BCR 143, IAEA 7, BCR 141, NIESCRM02, and IAEA 375) were used for determining the performance of a secondary target energy-dispersive X-ray fluorescence (EDXRF) spectrometer, Epsilon 5 (PANalytical, Almelo, the Netherlands). For the evaluation of the EDXRF spectra with polarized-beam high-energy excitation, the WinAxil software package has been applied. The results showed that Epsilon 5, EDXRF spectrometry is favorable for the determination of elemental concentrations in geological samples, but the sample preparation has the largest influence on the precision. However, they presented good agreement with certified values for most of the elements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/00387010.2012.661015
|
|
|
“Precise gamma ray measurement of the radial distribution of a cracking catalyst at diluted concentrations in a glass riser”. Dantas CC, Dos Santos VA, Melo ACBA, Van Grieken R, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 251, 201 (2006). http://doi.org/10.1016/J.NIMB.2006.05.009
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2006.05.009
|
|
|
“Preconcentration and XRF-determination of heavy metals in hair from Sudanese populations”. Eltayeb MAH, Van Grieken RE, Journal of radioanalytical and nuclear chemistry 131, 331 (1989). http://doi.org/10.1007/BF02060598
Abstract: Energy-dispersive X-ray fluorescence analysis was applied for the analysis of hair. The hair samples were digested in a mixture of nitric and perchloric acid and the heavy metals were precipitated with ammonium pyrrolidine dithiocarbamate. The accuracy, precision and recovery of the method for the elements Fe, Ni, Cu, Zn and Pb were evaluated through the analysis of a standard hair sample. The procedure was applied to the analysis of hair from an occupationally exposed group of Sudanese workers and a control group. The hair of the exposed group showed a range of 80550 ppm Fe, 612 ppm Cu, 57190 ppm Zn and 703700 ppm Pb, while that of the control group had a range of 60310 ppm Fe, 722 ppm Cu, 89170 ppm Zn and 317 ppm Pb.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02060598
|
|
|
“Preconcentration methods for the analysis of liquid samples by X-ray fluorescence techniques”. Marguí, E, Van Grieken R, Fontàs C, Hidalgo M, Queralt I, Applied spectroscopy reviews 45, 179 (2010). http://doi.org/10.1080/05704920903584198
Abstract: This article gives an overview of the state-of-the-art of multi-element and single-element preconcentration procedures prior to X-ray fluorescence (XRF) analysis of liquid samples. Many of these preconcentration methods were developed long ago and the purpose of this review is to present some new efficient variations of these methods and new techniques extending the possibilities of XRF for liquid solutions analysis. In addition, trends and future perspectives in this domain are also commented on and discussed in the last section of the review.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/05704920903584198
|
|
|
“Preconcentration methods for the analysis of water by X-ray spectrometric techniques”. Van Grieken R, Analytica chimica acta 143, 3 (1982). http://doi.org/10.1016/S0003-2670(01)95486-8
Abstract: All published procedures for multi-element preconcentration of trace elements, prior to x-ray fluorescence analysis of water, are reviewed and critically evaluated. Most preconcentration methods applied to the determination of single elements in water are also listed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95486-8
|
|
|
“Prediction of Mα/L&alpha, intensity ratios and the use in the spectra evaluation”. Trincavelli J, Montoro S, Van Grieken R, van Espen P, (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Preliminary evaluation of micro-Raman spectrometry for the characterization of individual aerosol particles”. Potgieter-Vermaak SS, Van Grieken R, Applied spectroscopy 60, 39 (2006). http://doi.org/10.1366/000370206775382848
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/000370206775382848
|
|
|
“Preliminary experiment of total reflection x-ray fluorescence using two glancing x-ray beams excitation”. Tsuji K, Sato T, Wagatsuma K, Claes M, Van Grieken R, The review of scientific instruments 70, 1621 (1999). http://doi.org/10.1063/1.1149687
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1063/1.1149687
|
|
|
“Preliminary experiments on grazing-exit electron probe microanalysis (GE-EPMA)”. Tsuji K, Spolnik Z, Wagatsuma K, Nullens R, Van Grieken RE, , 119 (1999)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Preliminary LAMMA investigations on healthy and acid rain affected spruce needles”. Goossenaerts C, Verbueken A, Van Grieken R, (1986)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Preliminary studies on the geochemistry of the Cauvery river basin”. Subramanian V, Van 't dack L, Van Grieken R, Proceedings of the Indian Academy of Sciences: earth and planetary sciences 94, 99 (1985). http://doi.org/10.1007/BF02871942
Abstract: Samples of water and sediments were collected over a three year period from the entire region of Cauvery river basin excluding the estuary. On the basis of our observations, we have calculated the average composition of the Cauvery river at several locations from the catchment to the river mouth, the downstream profile of sediment load, annual erosion rates, solute and sediment fluxes and have predicted on long term changes. The sediment chemistry was determined by x-ray fluorescence (xrf) technique, and calculated mean compositions of the Cauvery and its tributary bed and the suspended sediment were compared to those of world average river sediments. Downstream profiles of some of the elements appear to be controlled by size and mineralogical characteristics besides local factors specific to the location of the samples. Interelemental relationships indicated good correlation among the transition elements indicating their co-genetic behaviour within the drainage basin.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02871942
|
|
|
“Preparation of conducting electrodes from biological samples for multi-element trace analysis by spark-source mass spectrometry or emission spectrometry”. Vos L, Van Grieken R, Analytica chimica acta 164, 83 (1984). http://doi.org/10.1016/S0003-2670(00)85619-6
Abstract: Four decomposition procedures frequently used for biological material (dry ashing, open wet digestion, wet digestion in a teflon bomb and low-temperature ashing) are optimized for the conversion of biological samples to conducting electrodes suitable for multi-element trace determinations by spark-source mass spectrometry or emission spectrometry. The optimized procedures are evaluated with respect to contamination, retention and preconcentration of the trace elements, homogeneity of the electrodes and precision of the final results. Both dry-ashing methods are prone to losses by volatilization; simple dry ashing suffers from contamination problems during electrode preparation. Wet digestion gives better precision; digestion with nitric/sulfuric acids in an open flask is the method of choice for most elements being simpler and giving lower blanks than the bomb method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85619-6
|
|
|
“Present and future applications of beam techniques in environmental microanalysis”. Jambers W, Van Grieken R, Trends in analytical chemistry 15, 114 (1996). http://doi.org/10.1016/0165-9936(95)00098-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0165-9936(95)00098-4
|
|
|
“The processes dominating Ca dissolution of limestone when exposed to ambient atmospheric conditions as determined by comparing dissolution models”. Cardell Fernandez C, Cardell-Fernandez C, Vleugels G, Torfs K, Van Grieken R, Environmental geology 43, 160 (2002). http://doi.org/10.1007/S00254-002-0640-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00254-002-0640-X
|
|
|
“Progress in Belgian oceanographic research : proceedings of symposium, Brussels, 3-5 March 1985”. Van Grieken R, Wollast R page 479 p. (1985).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Progress in laboratory grazing emission X-ray fluorescence spectrometry”. Claes M, de Bokx P, Van Grieken R, X-ray spectrometry 28, 224 (1999). http://doi.org/10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199907/08)28:4<224::AID-XRS337>3.3.CO;2-W
|
|
|
“Quantification in grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken RE, de Bokx PK, Urbach HP, Spectrochimica acta: part B : atomic spectroscopy 54, 1525 (1999). http://doi.org/10.1016/S0584-8547(99)00051-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00051-8
|
|