“Enamels in stained-glass windows : preparation, chemical composition, microstructure and causes of deterioration”. Caen J, Schalm O, van der Snickt G, van der Linden V, Frederickx P, Schryvers D, Janssens K, Cornelis E, van Dyck D, Schreiner M, , 121 (2005)
Keywords: P3 Proceeding; Art; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
|
|
|
“Enamels in stained glass windows: preparation, chemical composition, microstructure and causes of deterioration”. Schalm O, van der Linden V, Frederickx P, Luyten S, van der Snickt G, Caen J, Schryvers D, Janssens K, Cornelis E, van Dyck D, Schreiner M, Spectrochimica acta: part B : atomic spectroscopy 64, 812 (2009). http://doi.org/10.1016/j.sab.2009.06.005
Abstract: Stained glass windows incorporating dark blue and purple enamel paint layers are in some cases subject to severe degradation while others from the same period survived the ravages of time. A series of dark blue, greenblue and purple enamel glass paints from the same region (Northwestern Europe) and from the same period (16early 20th centuries) has been studied by means of a combination of microscopic X-ray fluorescence analysis, electron probe micro analysis and transmission electron microscopy with the aim of better understanding the causes of the degradation. The chemical composition of the enamels diverges from the average chemical composition of window glass. Some of the compositions appear to be unstable, for example those with a high concentration of K2O and a low content of CaO and PbO. In other cases, the deterioration of the paint layers was caused by the less than optimal vitrification of the enamel during the firing process. Recipes and chemical compositions indicate that glassmakers of the 1617th century had full control over the color of the enamel glass paints they made. They mainly used three types of coloring agents, based on Co (dark blue), Mn (purple) and Cu (light-blue or greenblue) as coloring elements. Bluepurple enamel paints were obtained by mixing two different coloring agents. The coloring agent for redpurple enamel, introduced during the 19th century, was colloidal gold embedded in grains of lead glass.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
Impact Factor: 3.241
Times cited: 28
DOI: 10.1016/j.sab.2009.06.005
|
|
|
“Editorial”. van Grieken R, Bogaerts A, Janssens K, Spectrochimica acta: part A: molecular spectroscopy 64, 1089 (2006). http://doi.org/10.1016/j.saa.2006.05.011
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.536
DOI: 10.1016/j.saa.2006.05.011
|
|
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
|
|
van Grieken R, Gijbels R, Speecke A, Hoste J (1971) Determination of oxygen, silicon, phosphorus and copper in iron and steel by 14 MeV neutron activation analysis. S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of synchrotron X-ray spectromicroscopy and related methods : 1 : artificially aged model samples”. Monico L, van der Snickt G, Janssens K, de Nolf W, Miliani C, Verbeeck J, Tian H, Tan H, Dik J, Radepont M, Cotte M, Analytical chemistry 83, 1214 (2011). http://doi.org/10.1021/ac102424h
Abstract: On several paintings by artists of the end of the 19th century and the beginning of the 20th Century a darkening of the original yellow areas, painted with the chrome yellow pigment (PbCrO4, PbCrO4·xPbSO4, or PbCrO4·xPbO) is observed. The most famous of these are the various Sunflowers paintings Vincent van Gogh made during his career. In the first part of this work, we attempt to elucidate the degradation process of chrome yellow by studying artificially aged model samples. In view of the very thin (1−3 μm) alteration layers that are formed, high lateral resolution spectroscopic methods such as microscopic X-ray absorption near edge (μ-XANES), X-ray fluorescence spectrometry (μ-XRF), and electron energy loss spectrometry (EELS) were employed. Some of these use synchrotron radiation (SR). Additionally, microscopic SR X-ray diffraction (SR μ-XRD), μ-Raman, and mid-FTIR spectroscopy were employed to completely characterize the samples. The formation of Cr(III) compounds at the surface of the chrome yellow paint layers is particularly observed in one aged model sample taken from a historic paint tube (ca. 1914). About two-thirds of the chromium that is present at the surface has reduced from the hexavalent to the trivalent state. The EELS and μ-XANES spectra are consistent with the presence of Cr2O3·2H2O (viridian). Moreover, as demonstrated by μ-XANES, the presence of another Cr(III) compound, such as either Cr2(SO4)3·H2O or (CH3CO2)7Cr3(OH)2 [chromium(III) acetate hydroxide], is likely.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 113
DOI: 10.1021/ac102424h
|
|
|
“Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of spectromicroscopic methods : 3 : synthesis, characterization, and detection of different crystal forms of the chrome yellow pigment”. Monico L, Janssens K, Miliani C, Brunetti BG, Vagnini M, Vanmeert F, Falkenberg G, Abakumov A, Lu Y, Tian H, Verbeeck J, Radepont M, Cotte M, Hendriks E, Geldof M, van der Loeff L, Salvant J, Menu M;, Analytical chemistry 85, 860 (2013). http://doi.org/10.1021/ac302158b
Abstract: The painter, Vincent van Gogh, and some of his contemporaries frequently made use of the pigment chrome yellow that is known to show a tendency toward darkening. This pigment may correspond to various chemical compounds such as PbCrO4 and PbCr1-xSxO4, that may each be present in various crystallographic forms with different tendencies toward degradation. Investigations by X-ray diffraction (XRD), mid-Fourier Transform infrared (FTIR), and Raman instruments (benchtop and portable) and synchrotron radiation-based micro-XRD and X-ray absorption near edge structure spectroscopy performed on oil-paint models, prepared with in-house synthesized PbCrO4 and PbCr1-xSxO4, permitted us to characterize the spectroscopic features of the various forms. On the basis of these results, an extended study has been carried out on historic paint tubes and on embedded paint microsamples taken from yellow-orange/pale yellow areas of 12 Van Gogh paintings, demonstrating that Van Gogh effectively made use of different chrome yellow types. This conclusion was also confirmed by in situ mid-FTIR investigations on Van Goghs Portrait of Gauguin (Van Gogh Museum, Amsterdam).
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 79
DOI: 10.1021/ac302158b
|
|
|
“Controlled formation of amine-templated mesostructured zirconia with remarkably high thermal stability”. Cassiers K, Linssen T, Aerts K, Cool P, Lebedev O, Van Tendeloo G, van Grieken R, Vansant EF, Journal of materials chemistry 13, 3033 (2003). http://doi.org/10.1039/b310200a
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 26
DOI: 10.1039/b310200a
|
|
|
“Compositional analysis of 17-18th century archaeological glass fragments, excavated in Mechelen, Belgium: comparison with data from neighboring cities in the Low Countries”. van der Linden V, Bultinck E, de Ruytter J, Schalm O, Janssens K, Devos W, Tiri W, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 239, 100 (2005). http://doi.org/10.1016/j.nimb.2005.06.219
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.109
Times cited: 15
DOI: 10.1016/j.nimb.2005.06.219
|
|
|
“The colour of silver stained glass : analytical investigations carried out with XRF, SEM/EDX, TEM and IBA”. Jembrih-Simbürger D, Neelmeijer C, Schalm O, Fredrickx P, Schreiner M, De Vis K, Mäder M, Schryvers D, Caen J, Journal of analytical atomic spectrometry 17, 321 (2002). http://doi.org/10.1039/b111024c
Abstract: Glass treated on its surface with silver compounds and an aluminosilicate, such as ochre or clay, at higher temperatures (between 550 and 650 °C) accepts a wide variety of a yellow colour. It is the aim of this study to investigate the parameters of the manufacturing process affecting the final colour of silver stained glass and to correlate them with the final colour and colour intensity. Therefore, defined mixtures of ochre and a silver compound (AgCl, AgNO3, Ag2SO4, Ag3PO4, Ag2O) were prepared and applied on soda-lime glass. The firing process was modified within the range from 563 to 630 °C and glass samples were analysed after treatment with energy dispersive X-ray fluorescence analysis (EDXRF), scanning electron microscopy (SEM/EDX), transmission electron microscopy (TEM), as well as ion beam analysis (IBA) with an external beam. Within the scope of IBA simultaneous measurements using particle-induced X-ray emission (PIXE), particle-induced gamma-ray emission (PIGE), and Rutherford backscattering spectrometry (RBS) were carried out in order to obtain the thickness of the Ag-rich surface layer and the depth distribution of Ag. By means of TEM the microstructure of the silver particles was visualised. XRF results show that the lowest amount of Ag could be detected on glass samples treated with silver stain mixtures containing AgCl and Ag2O. A low kiln temperature (e.g. 563 °C) results in a higher silver concentration at the surface and lower penetration depths. Furthermore, the results obtained with SEM/EDX at cross-sections of the glass samples could be confirmed by PIXE, PIGE, RBS, and TEM.
Keywords: A1 Journal article; Art; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 42
DOI: 10.1039/b111024c
|
|
|
“Colloquium Spectroscopicum Internationale 34 (CSI 34), Antwerp, Belgium, 4-9 September 2005”. Bogaerts A, Janssens K, van Grieken R Elsevier, Amsterdam (2006).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Colloquium Spectroscopicum Internationale 34, Antwerp (Belgium), 4-9 September 2005: preface”. Bogaerts A, Janssens K, van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 61, 373 (2006). http://doi.org/10.1016/j.sab.2006.04.011
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 2
DOI: 10.1016/j.sab.2006.04.011
|
|
|
“Colloquium Spectroscopicum Internationale 34, Antwerp, Belgium, 4-9 September 2005: preface”. Janssens K, Bogaerts A, van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 70, 907 (2006). http://doi.org/10.1016/j.talanta.2006.05.044
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.162
DOI: 10.1016/j.talanta.2006.05.044
|
|
|
“Colloquium Spectroscopicum Internationale 34: a collection of papers presented at the Colloquium Spectroscopicum Internationale, Antwerp, Belgium, 4-9 September 2005”. Janssens K, Bogaerts A, van Grieken R Elsevier, Amsterdam (2006).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Chemical characterization of neo-ceramic powders by time-of-flight and Fourier transform laser microprobe mass spectrometry”. Struyf H, van Vaeck L, Kennis P, Gijbels R, van Grieken R, Rapid communications in mass spectrometry 10, 699 (1996). http://doi.org/10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
Abstract: Laser microprobe mass spectrometry (LMMS) aims at the identification of local organic and inorganic constituents at the surface of solids, The low mass resolution capabilities of the initially used time-of-flight (TOF) mass spectrometers have often proved to be insufficient for identification, Therefore, high mass resolution Fourier transform (ET) LMMS was developed, Neo-ceramic powders with oxide or carbide coatings were analyzed by both FT LMMS and TOF LMMS, The data are useful to compare the analytical information gained from both methods, Analytical results of these samples by electron microprobe x-ray analysis (EPXMA) and secondary ion mass spectrometry (SIMS) are discussed to assess the place of FT LMMS and TOF LMMS in the spectrum of microanalytical techniques.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.253
Times cited: 11
DOI: 10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
|
|
|
“Casting light on the darkening of colors in historical paintings”. da Pieve F, Hogan C, Lamoen D, Verbeeck J, Vanmeert F, Radepont M, Cotte M, Janssens K, Gonze X, Van Tendeloo G, Physical review letters 111, 208302 (2013). http://doi.org/10.1103/PhysRevLett.111.208302
Abstract: The degradation of colors in historical paintings affects our cultural heritage in both museums and archeological sites. Despite intensive experimental studies, the origin of darkening of one of the most ancient pigments known to humankind, vermilion (α-HgS), remains unexplained. Here, by combining many-body theoretical spectroscopy and high-resolution microscopic x-ray diffraction, we clarify the composition of the damaged paint work and demonstrate possible physicochemical processes, induced by illumination and exposure to humidity and air, that cause photoactivation of the original pigment and the degradation of the secondary minerals. The results suggest a new path for the darkening process which was never considered by previous studies and prompt a critical examination of their findings.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.462
Times cited: 30
DOI: 10.1103/PhysRevLett.111.208302
|
|
|
“Application of trace element analysis to geothermal waters”. Gijbels R, van Grieken R, Blommaert W, Vandelannoote R, Van 't dack L, , 429 (1977)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Gijbels R, van Grieken R, Blommaert W, Van 't dack L, van Espen P, Nullens H, Saelens R (1983) Application of analytical methods for trace elements in geothermal waters : part 2 : Plombières, Bains-les-Bains, Bourbonne (Vosges). S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
Gijbels R, van Grieken R (1977) Application of analytical methods for trace elements in geothermal waters : part 1 : Amélie-les-Bains (Eastern Pyrenees). S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of nonconducting materials by dc glow discharge spectrometry”. Bogaerts A, Schelles W, van Grieken R Wiley, Chichester, page 293 (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of geothermal waters by spark source mass spectrometry”. Vandelannoote R, Blommaert W, Gijbels R, van Grieken R, Fresenius' Zeitschrift für analytische Chemie 309, 291 (1981). http://doi.org/10.1007/BF00488604
Abstract: Although the analysis of thermal water by spark-source mass spectrometry (SSMS) is rather timeconsuming, it allows the detection of about 20 elements of geochemical interest down to the ppb-level. A physical preconcentration is proposed in order to collect elements having quite different chemical properties, e.g. alkalis, transition elements, and elements occurring in anionic form. The relative sensitivity factors appear to be rather independent of the salt content of the graphite electrodes. Contrary to neutron activation analysis, SSMS has a quite uniform elemental sensitivity, and allows to determine elements for which neutron activation is not suitable, e.g. Sn and Pb. The precision of SSMS is however by a factor of about 2 worse than that obtained for neutron activation.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 8
DOI: 10.1007/BF00488604
|
|
|
“L'analyse des eaux géothermales par spectrométrie de masse à, étincelles”. Vandelannoote R, Blommaert W, van Grieken R, Gijbels R, Spectra 2000: la revue de l'instrumentation 53, 66 (1979)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|