“Selecting optimal carbon inks for fabricating high-performance screen-printed electrodes for diverse electroanalytical applications”. Barich H, Voet O, Sleegers N, Schram J, Montiel FN, Beltran V, Nuyts G, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 971, 118585 (2024). http://doi.org/10.1016/J.JELECHEM.2024.118585
Abstract: Carbon-based screen-printed electrodes (SPEs) are extensively employed in electrochemistry due to their reproducibility, low-cost production, disposability and versatility. It is commonly accepted that batch to batch variations may occur due to variations in the ink formulation or the use of a different ink to print the electrodes. In this paper, three different commercial carbon-based inks (DuPont, Loctite and SunChemical) were used to manufacture SPEs, referred to respectively as Dup-SPE, Loc-SPE and Sun-SPE, using a semi-automated screen-printing technology. This study focuses on evaluating the quality, characteristics and electrochemical performance of the fabricated SPEs. Furthermore, the study aimed to investigate potential correlations between the ink composition and the nature of different target molecules, as well as their electroanalytical responses. Specifically, phenolic compounds and cocaine cutting agents are tested in alkaline conditions, while benzodiazepines and cephalosporine antibiotics are investigated in acidic media using square wave voltammetry (SWV). This aims to extract insights for the proper selection of inks and SPEs in both conditions. Additionally, a scan rate study of cephalosporine antibiotics using linear sweep voltammetry (LSV) is performed confirming the ion-exchange polymer layer on the electrode surface of Loc-SPE, which impact surface and electrochemical properties, leading to drawbacks in alkaline SWV sensing, but strategic benefits in reductive sensing resulting in an enhanced selective detection of specific targets. The insights on ink-specific influences on the surface and electrochemical properties of the SPEs obtained, may be useful for facilitating the electrode selection in diverse electrochemical applications, emphasizing the critical role of ink composition in achieving desired sensing capabilities.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab); Antwerp engineering, PhotoElectroChemistry & Sensing (A-PECS)
Impact Factor: 4.5
DOI: 10.1016/J.JELECHEM.2024.118585
|
|
|
“Singlet oxygen-based photoelectrochemical detection of miRNAs in prostate cancer patients&rsquo, plasma : a novel diagnostic tool for liquid biopsy”. Thiruvottriyur Shanmugam S, Campos R, Trashin S, Daems E, Carneiro D, Fraga A, Ribeiro R, De Wael K, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 158, 108698 (2024). http://doi.org/10.1016/J.BIOELECHEM.2024.108698
Abstract: Dysregulation of miRNA expression occurs in many cancers, making miRNAs useful in cancer diagnosis and therapeutic guidance. In a clinical context using methods such as polymerase chain reaction (PCR), the limited amount of miRNAs in circulation often limits their quantification. Here, we present a PCR-free and sensitive singlet oxygen (1O2)-based strategy for the detection and quantification of miRNAs in untreated human plasma from patients diagnosed with prostate cancer. A target miRNA is specifically captured by functionalised magnetic beads and a detection oligonucleotide probe in a sandwich-like format. The formed complex is concentrated at the sensor surface via magnetic beads, providing an interface for the photoinduced redox signal amplification. The detection oligonucleotide probe bears a molecular photosensitiser, which produces 1O2 upon illumination, oxidising a redox reporter and creating a redox cycling loop, allowing quantification of pM level miRNA in diluted human plasma within minutes after hybridisation and without target amplification.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2024.108698
|
|
|
“The organo-metal-like nature of long-range conduction in cable bacteria”. Pankratov D, Hidalgo Martinez S, Karman C, Gerzhik A, Gomila G, Trashin S, Boschker HTS, Geelhoed JS, Mayer D, De Wael K, Meysman FJR, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 157, 108675 (2024). http://doi.org/10.1016/J.BIOELECHEM.2024.108675
Abstract: Cable bacteria are filamentous, multicellular microorganisms that display an exceptional form of biological electron transport across centimeter-scale distances. Currents are guided through a network of nickel-containing protein fibers within the cell envelope. Still, the mechanism of long-range conduction remains unresolved. Here, we characterize the conductance of the fiber network under dry and wet, physiologically relevant, conditions. Our data reveal that the fiber conductivity is high (median value: 27 S cm−1; range: 2 to 564 S cm−1), does not show any redox signature, has a low thermal activation energy (Ea = 69 ± 23 meV), and is not affected by humidity or the presence of ions. These features set the nickel-based conduction mechanism in cable bacteria apart from other known forms of biological electron transport. As such, conduction resembles that of an organic semi-metal with a high charge carrier density. Our observation that biochemistry can synthesize an organo-metal-like structure opens the way for novel bio-based electronic technologies.
Keywords: A1 Journal article
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2024.108675
|
|
|
“Synergism of the initial stage of removal of dielectric materials during electrical erosion processing in electrolytes”. Zaripov AA, Khalilov UB, Ashurov KB, Surface engineering and applied electrochemistry 59, 712 (2023). http://doi.org/10.3103/S1068375523060194
Abstract: Ceramics and composites, many of whose physicochemical properties significantly exceed similar properties of metals and their alloys, are processed qualitatively mainly by the electroerosion method. Despite the existing works, the mechanism of the initial stage of the removal of materials has not yet been identified. For a comprehensive understanding of the mechanism of the removal of dielectrics, a new model is proposed based on the experimental results obtained on an improved electroerosion installation. It was revealed that the initial stage of the removal of a dielectric material consists of three successive stages that are associated with the synergistic effect on the process of the anionic group of electrolytes, plasma flare, and the cavitation shock. This makes it possible to better understand the mechanism of the removal of composite and ceramic materials, which should contribute to ensuring the machinability of those materials and their wide use in promising technologies.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.3103/S1068375523060194
|
|
|
“CO₂, electrochemical reduction with Zn-Al layered double hydroxide-loaded gas-diffusion electrode”. Nakazato R, Matsumoto K, Yamaguchi N, Cavallo M, Crocella V, Bonino F, Quintelier M, Hadermann J, Rosero-navarro NC, Miura A, Tadanaga K, Electrochemistry 91, 097003 (2023). http://doi.org/10.5796/ELECTROCHEMISTRY.23-00080
Abstract: Carbon dioxide electrochemical reduction (CO2ER) has attracted considerable attention as a technology to recycle CO2 into raw materials for chemicals using renewable energies. We recently found that Zn-Al layered double hydroxides (Zn-Al LDH) have the CO-forming CO2ER activity. However, the activity was only evaluated by using the liquid-phase CO2ER. In this study, Ni-Al and Ni-Fe LDHs as well as Zn-Al LDH were synthesized using a facile coprecipitation process and the gas-phase CO2ER with the LDH-loaded gas-diffusion electrode (GDE) was examined. The products were characterized by XRD, STEM-EDX, BF-TEM and ATR-IR spectroscopy. In the ATR-IR results, the interaction of CO2 with Zn-Al LDH showed a different carbonates evolution with respect to other LDHs, suggesting a different electrocatalytic activity. The LDH-loaded GDE was prepared by simple drop-casting of a catalyst ink onto carbon paper. For gas-phase CO2ER, only Zn-Al LDH exhibited the CO2ER activity for carbon monoxide (CO) formation. By using different potassium salt electrolytes affording neutral to strongly basic conditions, such as KCl, KHCO3 and KOH, the gas-phase CO2ER with Zn-Al LDH-loaded GDE showed 1.3 to 2.1 times higher partial current density for CO formation than the liquid-phase CO2ER.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
DOI: 10.5796/ELECTROCHEMISTRY.23-00080
|
|
|
“Haem-mediated albumin biosensing : towards voltammetric detection of PFOA”. Moro G, Campos R, Daems E, Moretto LM, De Wael K, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 152, 108428 (2023). http://doi.org/10.1016/J.BIOELECHEM.2023.108428
Abstract: The haem group is a promising redox probe for the design of albumin-based voltammetric sensors. Among the endogenous ligands carried by human serum albumin (hSA), haem is characterised by a reversible redox behaviour and its binding kinetics strongly depend on hSA’s conformation, which, in turn, depends on the presence of other ligands. In this work, the potential applicability of haem, especially hemin, as a redox probe was first tested in a proof-of-concept study using perfluorooctanoic acid (PFOA) as model analyte. PFOA is known to bind hSA by occupying Sudlow’s I site (FA7) which is spatially related to the haem-binding site (FA1). The latter undergoes a conformational change, which is expected to affect hemin’s binding kinetics. To verify this hypothesis, hemin:albumin complexes in the presence/absence of PFOA were first screened by UV–Vis spectroscopy. Once the complex formation was verified, haem was further characterised via electrochemical methods to estimate its electron transfer kinetics. The hemin:albumin:PFOA system was studied in solution, with the aim of describing the multiple equilibria at stake and designing an electrochemical assay for PFOA monitoring. This latter could be integrated with protein-based bioremediation approaches for the treatment of per- and polyfluoroalkyl substances polluted waters. Overall, our preliminary results show how hemin can be applied as a redox probe in albumin-based voltammetric sensing strategies.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2023.108428
|
|
|
“Development of an electrochemiluminescent oligonucleotide-based assay for the quantification of prostate cancer associated miR-141-3p in human serum”. Campos R, Thiruvottriyur Shanmugam S, Daems E, Ribeiro R, De Wael K, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 153, 108495 (2023). http://doi.org/10.1016/J.BIOELECHEM.2023.108495
Abstract: MicroRNAs (miRNAs) are small oligonucleotides (18–25 bases), biologically relevant for epigenetic regulation of key processes, particularly in association with cancer. Research effort has therefore been directed towards the monitoring and detection of miRNAs to progress (early) cancer diagnoses. Traditional detection strategies for miRNAs are expensive, with a lengthy time-to-result. In this study we develop an oligonucleotide-based assay using electrochemistry for the specific, selective and sensitive detection of a circulating miRNA (miR-141) associated with prostate cancer. In the assay, the excitation and readout of the signal are independent: an electrochemical stimulation followed by an optical readout. A ‘sandwich’ approach is incorporated, consisting of a biotinylated capture probe immobilised on streptavidin-functionalised surfaces and a detection probe labelled with digoxigenin. We show that the assay allows the detection of miR-141 in human serum, even in the presence of other miRNAs, with a LOD of 0.25 pM. The developed electrochemiluminescent assay has, therefore, the potential for efficient universal oligonucleotide target detection via the redesign of capture and detection probes.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2023.108495
|
|
|
“Impedimetric sensing of the immuno-enzymatic reaction of gliadin with a collagen-modified electrode”. Bottari F, Moretto LM, Ugo P, Electrochemistry communications 97, 51 (2018). http://doi.org/10.1016/J.ELECOM.2018.10.011
Abstract: This paper presents a previously unexplored biosensing strategy for detecting gliadin which exploits the crosslinking of gliadin with collagen, catalyzed by transglutaminase at the interfacial electron transfer rate, on a modified electrode. The process is monitored by electrochemical impedance spectroscopy using a glassy carbon electrode coated with a collagen layer. To validate the specificity of the response as well as to eliminate possible interferences from other proteins, such as soy protein or casein, the captured gliadin is further reacted with a specific anti-gliadin antibody. Changes in charge transfer resistance, measured from the Nyquist plots, scale linearly with the gliadin concentration in the range 5-20 mg/L, a range suitable for testing the gliadin concentration in gluten-free food commodities.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ELECOM.2018.10.011
|
|
|
“Electrochemical identification of hazardous phenols and their complex mixtures in real samples using unmodified screen-printed electrodes”. Barich H, Cánovas R, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 904, 115878 (2022). http://doi.org/10.1016/J.JELECHEM.2021.115878
Abstract: The electrochemical behavior of some of the most relevant endocrine-disrupting phenols using unmodified carbon screen-printed electrodes (SPEs) is described for the first time. Experiments were made to assess the electrochemical behavior of phenol (PHOH), pentachlorophenol (PCP), 4-tert octylphenol (OP) and bisphenol A (BPA) and their determination in the most favorable conditions, using voltammetric methods such as cyclic voltammetry (CV), linear sweep voltammetry (LSV) and square wave voltammetry (SWV) in Britton Robinson (BR) buffer. Further, the usefulness of the electrochemical approach was validated with real samples from a local river and was compared to commercial phenols test kit, which is commonly used for on-site screening in industrial streams and wastewaters. Finally, the approach was compared with a lab-bench standard method using real samples, i.e., high-performance liquid chromatography with a photodiode array detector (HPLC-DAD).
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 4.5
DOI: 10.1016/J.JELECHEM.2021.115878
|
|
|
“Size-controlled electrodeposition of Cu nanoparticles on gas diffusion electrodes in methanesulfonic acid solution”. Pacquets L, Irtem E, Neukermans S, Daems N, Bals S, Breugelmans T, Journal Of Applied Electrochemistry 51 (2020). http://doi.org/10.1007/S10800-020-01474-5
Abstract: In this paper electrodeposition is used to obtain Cu nanoparticles, as it allows good control over particle size and distribution. These Cu particles were deposited onto a gas diffusion electrode which increased the resulting surface area. Prior to deposition, the surface was pre-treated with NaOH, HNO3, MQ and TX100 to investigate the influence on the electrodeposition of Cu on the gas diffusion electrode (GDE). When using HNO3, the smallest particles with the most homogeneous distribution and high particle roughness were obtained. Once the optimal substrate was determined, we further demonstrated that by altering the electrodeposition parameters, the particle size and density could be tuned. On the one hand, increasing the nucleation potential led to a higher particle density resulting in smaller particles because of an increased competition between particles. Finally, the Cu particle size increased when applying a greater growth charge and growth potential. This fundamental study thus opens up a path towards the synthesis of supported Cu materials with increased surface areas, which is interesting from a catalytic point of view. Larger surface areas are generally correlated with a better catalyst performance and thus higher product yields. This research can contributed in obtaining new insides into the deposition of metallic nanoparticles on rough surfaces. [GRAPHICS] .
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 2.9
Times cited: 3
DOI: 10.1007/S10800-020-01474-5
|
|
|
“Integration of a photoelectrochemical cell in a flow system for quantification of 4-aminophenol with titanium dioxide”. Mendonça CD, Rahemi V, Hereijgers J, Breugelmans T, Machado SAS, De Wael K, Electrochemistry Communications 117, 106767 (2020). http://doi.org/10.1016/J.ELECOM.2020.106767
Abstract: The photoelectrochemical quantification of phenolic compounds such as hydroquinone (HQ) and 4-aminophenol (4-AP) is accomplished by integrating a photoelectrochemical cell into a flow injection analysis (FIA) setup. It is a well-known fact that during the electroanalysis of phenolic compounds, the electrode surface is susceptible to poisoning. However, electrode fouling can be reduced significantly by using the FIA system with periodic washing of the electrode. Reactive oxygen species (ROS), which are generated on the surface of TiO2 under UV light, can oxidize phenolic compounds such as 4-AP. The oxidized form of 4-AP is reduced back at the electrode surface, generating a measurable signal proportional to its concentration. The factors influencing the perfor-mance of the sensor, such as flow rate, applied potential for back reduction and pH, are investigated in detail. In the concentration range 0.0125-1.0 mu M, a linear correlation between the photocurrent and the concentration of 4-AP was observed with a sensitivity of 0.6 A M-1 cm(-2) and a limit of detection of 18 nM. A straightforward analytical methodology for the on-site, highly sensitive and low-cost quantification of phenolic compounds is presented, based on the use of TiO2 in a photoelectrochemical flow cell.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 5.4
Times cited: 1
DOI: 10.1016/J.ELECOM.2020.106767
|
|
|
“Covalent immobilization of delipidated human serum albumin on poly(pyrrole-2-carboxylic) acid film for the impedimetric detection of perfluorooctanoic acid”. Moro G, Bottari F, Liberi S, Covaceuszach S, Cassetta A, Angelini A, De Wael K, Moretto LM, Bioelectrochemistry 134, 107540 (2020). http://doi.org/10.1016/J.BIOELECHEM.2020.107540
Abstract: The immobilization of biomolecules at screen printed electrodes for biosensing applications is still an open challenge. To enrich the toolbox of bioelectrochemists, graphite screen printed electrodes (G-SPE) were modified with an electropolymerized film of pyrrole-2-carboxilic acid (Py-2-COOH), a pyrrole derivative rich in carboxylic acid functional groups. These functionalities are suitable for the covalent immobilization of biomolecular recognition layers. The electropolymerization was first optimized to obtain stable and conductive polymeric films, comparing two different electrolytes: sodium dodecyl sulphate (SDS) and sodium perchlorate. The G-SPE modified with Py-2-COOH in 0.1 M SDS solution showed the required properties and were further tested. A proof-of-concept study for the development of an impedimetric sensor for perfluorooctanoic acid (PFOA) was carried out using the delipidated human serum albumin (hSA) as bioreceptor. The data interpretation was supported by size exclusion chromatography and small-angle X-ray scattering (SEC-SAXS) analysis of the bioreceptor-target complex and the preliminary results suggest the possibility to further develop this biosensing strategy for toxicological and analytical studies.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 5
DOI: 10.1016/J.BIOELECHEM.2020.107540
|
|
|
“A new multisine-based impedimetric aptasensing platform”. Pauwels D, Pilehvar S, Geboes B, Hubin A, De Wael K, Breugelmans T, Electrochemistry communications 71, 23 (2016). http://doi.org/10.1016/J.ELECOM.2016.07.010
Abstract: In this work an aptamer-based biosensor is combined with a multisine electrochemical impedance spectroscopy sensing methodology into a novel and promising biosensing strategy. Employing a multisine instead of a traditional single sine measuring method allows the detection and quantification of parameters that provide information about the accuracy and reliability of the results, such as noise and distortions. This does not only lead to a shorter measurement time, but it also enables an easy and fast evaluation of the quality of the data and fitting, leading to more accurate results.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 4.396
Times cited: 1
DOI: 10.1016/J.ELECOM.2016.07.010
|
|
|
“Influence of the deposition method, temperature and deposition time on the corrosion inhibition of lead dodecanoate coatings deposited on lead surfaces”. De Keersmaecker M, De Wael K, Adriaens A, Journal of solid state electrochemistry 17, 1259 (2013). http://doi.org/10.1007/S10008-012-1964-4
Abstract: Electrochemical impedance measurements have been used to investigate the influence of the deposition method, including time and temperature, upon the corrosion inhibition characteristics of lead dodecanoate coatings on lead electrodes. The results were analysed using multivariate statistics and show that, in general, these easily prepared coatings are very protective against corrosion. The temperature proves to be an important parameter for the quality and the corrosion inhibition efficiency of the coating. A comparison between two different electrochemically assisted deposition methods, immersion using a reduction pretreatment and cyclic voltammetry, does not show significant differences. Using the immersion technique at room temperature, the deposition time was tested as the third influencing parameter for the corrosion inhibition efficiency of the deposited lead dodecanoate coatings. A longer deposition time of the lead into the sodium dodecanoate solution provides a layer with a somewhat higher corrosion resistance.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.316
Times cited: 4
DOI: 10.1007/S10008-012-1964-4
|
|
|
“Electrodeposition of gold nanoparticles on boron doped diamond electrodes for the enhanced reduction of small organic molecules”. Bottari F, De Wael K, Journal of electroanalytical chemistry : an international journal devoted to all aspects of electrode kynetics, interfacial structure, properties of electrolytes, colloid and biological electrochemistry. 801, 521 (2017). http://doi.org/10.1016/J.JELECHEM.2017.07.053
Abstract: The performance of gold nanoparticles electrodeposited on boron doped diamond (BDD) electrodes was investigated in respect to the reduction of chloramphenicol (CAP), an antibiotic of the phenicols family. The chosen deposition protocol, three nucleation-growing pulses, shows a remarkable surface coverage, with an even distribution of average-sized gold particles (~ 50 nm), and it was proven capable of generating a three-fold increase in the CAP reduction current. A calibration plot for CAP detection was obtained in the micromolar range (535 μM) with good correlation coefficient (0.9959) and an improved sensitivity of 0.053 μA μM− 1 mm− 2 compared to the electrochemistry of CAP at a bare BDD electrode.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.012
Times cited: 4
DOI: 10.1016/J.JELECHEM.2017.07.053
|
|
|
“Electrochemical strategies for the detection of forensic drugs”. Florea A, De Jong M, De Wael K, Current opinion in electrochemistry 11, 34 (2018). http://doi.org/10.1016/J.COELEC.2018.06.014
Abstract: Illicit drugs consumption and trafficking is spread worldwide and remains an increasing challenge for local authorities. Forensic drugs and their metabolites are released into wastewaters due to human excretion after illegal consumption of drugs and occasionally due to disposal of clandestine laboratory wastes into sewage systems, being recently classified as the latest group of emerging pollutants. Hence, it is essential to have efficient and accurate methods to detect these type of compounds in seized street samples, biological fluids and wastewaters in order to reduce and prevent trafficking and consumption and negative effects on aquatic systems. Electrochemical strategies offer a fast, portable, low-cost and accurate alternative to chromatographic and spectrometric methods, for the analysis of forensic drugs and metabolites in different matrices. Recent electrochemical strategies applied to the detection of illicit drugs in wastewaters, biological fluids and street samples are presented in this review, together with the impact of drug consumption on the environment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 7
DOI: 10.1016/J.COELEC.2018.06.014
|
|
|
“Electrochemical determination of hydrogen peroxide with cytochrome c peroxidase and horse heart cytochrome c entrapped in a gelatin hydrogel”. De Wael K, Bashir Q, van Vlierberghe S, Dubruel P, Heering HA, Adriaens A, Bioelectrochemistry: an international journal devoted to electrochemical aspects of biology and biological aspects of electrochemistry 83, 15 (2012). http://doi.org/10.1016/J.BIOELECHEM.2011.07.001
Abstract: A novel and versatile method, based on a membrane-free enzyme electrode in which both the enzyme and a mediator protein are entrapped in a gelatine hydrogel was developed for the fabrication of biosensors. As a proof of principle, we prepared a hydrogen peroxide biosensor by successfully entrapping both horse heart cytochrome c (HHC) and Saccharomyces cerevisae cytochrome c peroxidase (CCP) in a gelatin matrix which is immobilized on a gold electrode. This electrode was first pretreated with 6-mercaptohexanol. The biosensor displayed a rapid response and an expanded linear response range from 0 to 0.3 mM (R = 0.987) with a detection limit of 1 × 10− 5 M in a HEPES buffer solution (pH 7.0). This method of encapsulation is now further investigated for industrial biosensor applications.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.346
Times cited: 31
DOI: 10.1016/J.BIOELECHEM.2011.07.001
|
|
|
“Electrochemical deposition of a copper carboxylate layer on copper as potential corrosion inhibitor”. Elia A, De Wael K, Dowsett M, Adriaens A, Journal of solid state electrochemistry 16, 143 (2011). http://doi.org/10.1007/S10008-010-1283-6
Abstract: Carboxylic acids and sodium carboxylates are used to protect metals against aqueous and atmospheric corrosion. In this paper, we describe the application of a layer of copper carboxylate on the surface of a copper electrode by means of cyclic voltammetry technique and tests which measure the corresponding resistance to aqueous corrosion. Unlike the soaking process, which also forms a film on the surface, the use of cyclic voltammetry allows one to follow the deposition process of the copper carboxylates onto the electrode. The modified electrodes have been characterised with infrared spectroscopy. In addition, the corrosion resistance of the film has been investigated using polarisation resistance and Tafel plot measurements.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.316
Times cited: 8
DOI: 10.1007/S10008-010-1283-6
|
|
|
“Challenges in the electrochemical (bio)sensing of non-electroactive food and environmental contaminants”. Moro G, De Wael K, Moretto LM, Current opinion in electrochemistry 16, 57 (2019). http://doi.org/10.1016/J.COELEC.2019.04.019
Abstract: The electrochemical detection of non-electroactive contaminants can be successfully faced via the use of indirect detection strategies. These strategies can provide sensitive and selective responses often coupled with portable and user-friendly analytical tools. Indirect detection strategies are usually based on the change in the signal of an electroactive probe, induced by the presence of the target molecule at a modified electrode. This critical review aims at addressing the developments in indirect electro-sensing strategies for non-electroactive contaminants in food and environmental analysis in the last years (2017-2019). Emphasis is given to the strategy design, the electrode modifiers used and the feasibility of technological transfer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 4
DOI: 10.1016/J.COELEC.2019.04.019
|
|
|
“Bio(inspired) strategies for the electro-sensing of β-lactam antibiotics”. Bottari F, Blust R, De Wael K, Current opinion in electrochemistry 10, 143 (2018). http://doi.org/10.1016/J.COELEC.2018.05.016
Abstract: The dire previsions of the WHO on the so-called “post-antibiotic era” and the continuous and global rise of anti-microbial resistance, spurs our research community to find better ways to fight these threats. In light of this severe threat to human health many attempts have been made to develop efficient methods to detect antibiotic residues in different streams. The use of electrochemistry seems an inviting approach for on-site and fast monitoring. In this critical review, recent developments in the field of (bio) electro-sensing of 19-lactam antibiotics will be presented, with a focus on aptamers and molecularly imprinted polymers, the two main promises of a new generation of biosensors, yet to be fulfilled.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 15
DOI: 10.1016/J.COELEC.2018.05.016
|
|
|
“Electrochemically activated MnO as a cathode material for sodium-ion batteries”. Zhang L, Batuk D, Chen G, Tarascon J-M, Electrochemistry communications 77, 81 (2017). http://doi.org/10.1016/J.ELECOM.2017.02.020
Abstract: Besides classical electrode materials pertaining to Li-ion batteries, recent interest has been devoted to pairs of active redox composites having a redox center and an intercalant source. Taking advantage of the NaPFG salt decomposition above 4.2 V. we extrapolate this concept to the electrochemical in situ preparation of F-based MnO composite electrodes for Na-ion batteries. Such electrodes exhibit a reversible discharge capacity of 145 mAh g(-1) at room temperature. The amorphization of pristine MnO electrode after activation is attributed to the electrochemical grinding effect caused by substantial atomic migration and lattice strain build-up upon cycling. (C) 2017 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 4.396
Times cited: 8
DOI: 10.1016/J.ELECOM.2017.02.020
|
|
|
“Lanthanum-strontium cuprate as a promising cathodic matreila for solid oxide fuel cells”. Mazo GN, Savvin SN, Abakumov AM, Hadermann J, Dobrovol'skii YA, Leonova LS, Russian journal of electrochemistry 43, 436 (2007). http://doi.org/10.1134/S1023193507040106
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.828
Times cited: 8
DOI: 10.1134/S1023193507040106
|
|
|
“Electrodeposition of Ag nanoparticles onto carbon coated TEM grids : a direct approach to study early stages of nucleation”. Ustarroz J, Gupta U, Hubin A, Bals S, Terryn H, Electrochemistry communications 12, 1706 (2010). http://doi.org/10.1016/j.elecom.2010.10.002
Abstract: An innovative experimental approach to study the electrodeposition of small nanoparticles and the early stages of electrochemical nucleation and growth is presented. Carbon coated gold TEM grids are used as substrates for the electrodeposition of silver nanoparticles so that electrochemical data, FESEM, HAADFSTEM and HRTEM data can be acquired from the same sample without the need to remove the particles from the substrate. It is shown that the real distribution of nanoparticles cannot be resolved by FESEM whereas HAADFSTEM analysis confirms that a distribution of small nanoparticles (d ≈ 12 nm) coexist with large nanoparticles corresponding to a bimodal size distribution. Besides, particles grown under the same conditions have been found to present different structures such as monocrystals, polycrystals or aggregates of smaller particles.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 4.396
Times cited: 52
DOI: 10.1016/j.elecom.2010.10.002
|
|