|
“Determination of selenium in blood components by X-ray emission spectrometry”. Robberecht H, Deelstra H, Van Grieken R, Biological trace element research 25, 149 (1990). http://doi.org/10.1007/BF02990412
Abstract: Sampling, storing, sample pretreatment, and experimental conditions for selenium (Se) determination in human serum, plasma, and whole blood by X-ray emission spectrometric (XRS) methods are described. Concentration levels in these biological fluids, found by this technique, are discussed and compared to values found by other techniques for the same healthy population group in the same area. XRS analysis of blood from patients with various pathological conditions is reviewed, with special attention to the relation of Se with the concentration level of other essential or nonessential trace elements.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02990412
|
|
|
“Determination of trace selenium in biological material by preconcentration and X-ray emission spectrometry”. Robberecht H, Van Grieken R, Analytica chimica acta 147, 113 (1983). http://doi.org/10.1016/0003-2670(83)80077-4
Abstract: Selenium is determined in the ng g−1 to μg g−1 range in biological and environmental samples. A wet digestion procedure was optimized with respect to volatility losses and recovery yields, by using 75Se metabolically incorporated into rat organs. Selenium is preconcentrated from the digestion liquid by a two-step reduction with 4 M HCl and ascorbic acid. The colloidal selenium formed is adsorbed on activated carbon and filtered on a Nucleopore membrane for measurement by energy-dispersive x-ray fluorescence. Almost complete recovery was obtained, and the detection limit was 20 ng, corresponding to 10 ng g−1 for a 2-g sample. Biological reference materials were analyzed with satisfactory results, and the accuracy of the method was good.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(83)80077-4
|
|
|
“Energy-dispersive X-ray fluorescence for direct trace analysis of biomedical and environmental samples”. Van Grieken R, Robberecht H, Shani J, Van Dyck P, Vos L page 159 (1982).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Evaluation of multi-element analysis of blood serum by energy-dispersive x-ray spectrometry”. Robberecht H, Van Grieken R, Shani J, Barak S, Analytica chimica acta 136, 285 (1982). http://doi.org/10.1016/S0003-2670(01)95388-7
Abstract: Conventional energy-dispersive x-ray fluorescence is applied in the analysis of blood serum to give the concentrations of 710 elements simultaneously with minimal manipulation of the samples. Simple spotting onto a Mylar carrier of 250 μl of serum, doped with two internal standards, was chosen as the sample preparation step. Some 200 serum samples, analyzed in replicate (n = 26), were used to evaluate this procedure. The detection limits are 4 μg ml-1 for K and Ca, 0.50.2 μg ml-1 for Fe, Cu, Pb and Zn, and less than 0.1 μg ml-1 for Se, Rb and Sr. Well above these limits, the standard deviation is around 10%. Comparison with the results of other measurements on the same samples indicates an accuracy of that order. The simplicity and high throughput, and the possibility of automating the x.r.f. measurements, make the proposed procedure suitable for screening large numbers of sera.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95388-7
|
|
|
“Increased erythrocyte glutathione peroxidase activity in psoriatics consuming high-selenium drinking water at the dead-sea psoriasis treatment center”. Shani J, Livshitz T, Robberecht H, Van Grieken R, Rubinstein N, Even-Paz Z, Pharmacological research communications 17, 479 (1985). http://doi.org/10.1016/0031-6989(85)90083-9
Abstract: Erythrocyte selenium-dependent glutathione peroxidase activity was measured in psoriatic Danes, before and after their four-week balneological therapy at the Ein-Bokek International Psoriasis Treatment Center, on the Dead-Sea shore in Israel. The drinking water in Ein-Bokek was found to be rich in selenium, a trace element with anticarcinogenic properties and of great importance in human nutrition and health. The most reliable biological parameter for increase in selenium bioavailability is the erythrocytes' glutathione-peroxidase activity. As psoriasis is a proliferative skin disease, the activity of this enzyme was assayed in 35 psoriatic Danes and in 25 long-term local hotel workers, as well as in 34 volunteers drinking low-selenium water. The glutathione peroxidase activity in the psoriatic patients increased significantly during their four-week stay in Ein-Bokek. Erythrocyte glutathione peroxidase activity in the hotel workers was 50% higher than that in the healthy volunteers consuming low-selenium water. A possible role of selenium in psoriasis is suggested.
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0031-6989(85)90083-9
|
|
|
“Losses of metabolically incorporated selenium in common digestion procedures for biological material”. Robberecht HJ, Van Grieken RE, Van den Bosch PA, Deelstra H, vanden Berghe D, Talanta : the international journal of pure and applied analytical chemistry 29, 1025 (1982). http://doi.org/10.1016/0039-9140(82)80244-0
Abstract: Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80244-0
|
|
|
“Metal pollution and selenium distributions in soils and grass near a non-ferrous plant”. Robberecht H, Deelstra H, vanden Berghe D, Van Grieken R, The science of the total environment 29, 229 (1983). http://doi.org/10.1016/0048-9697(83)90093-1
Abstract: Multi-element analysis results of direct energy-dispersive X-ray fluorescence of soil samples taken in the vicinity of a non-ferrous plant in Antwerp are reported. High concentrations of Pb, Cu, Zn, As and Se are found in nearby residential areas, especially in top-soil layers. Selenium pollution appears not to be leached significantly to lower soil horizons, but it is available for uptake by rye-grass, in which toxic levels are found. Results are compared to literature data. Hydride generation atomic absorption spectrometry proved to be unsuitable for direct analysis of the heavily contaminated soils.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(83)90093-1
|
|
|
“Multi-element analysis of urine by energy-dispersive x-ray fluorescence spectrometry”. Vos L, Robberecht H, Van Dyck P, Van Grieken R, Analytica chimica acta 130, 167 (1981). http://doi.org/10.1016/S0003-2670(01)84161-1
Abstract: For multi-element analysis of human urine, 25-ml samples doped with yttrium as internal standard are evaporated gently and then ashed up to 460°C overnight. The residue is pelletized and analysed by energy-dispersive x-ray fluorescence. Acid addition to facilitate the digestion is not mandatory. Recoveries are nearly quantitative for traces of Fe, Ni, Cu, Zn and Sr, to a lesser extent for lead, but not for arsenic or selenium. The standard deviation per measurement is typically around 6%. The detection limits are such that some 10 elements can be determined simultaneously in normal urine, and possibly more in cases of importance to toxicology or industrial hygiene.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84161-1
|
|
|
“OPtimized selenite determination in environmental waters by X-ray fluorescence”. Robberecht H, Van Grieken R, Van der Sloot HA page 463 (1980).
Keywords: H3 Book chapter; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Percentage selenium in consumed belgian feeding”. Robberecht H, Deelstra H, vanden Berghe D, Van Grieken R, Revue des fermentations et des industries alimentaires 37, 188 (1982)
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Sample contamination from a commercial grinding unit”. Van Grieken R, Van de Velde R, Robberecht H, Analytica chimica acta 118, 137 (1980). http://doi.org/10.1016/S0003-2670(01)93724-9
Abstract: The contamination of ground samples by a commercially available Lovibond McCrone Micronizing Mill is discussed. Tracer and weighing experiments showed that abrasion of corundum grinding elements was important, introducing 620 mg of abrasion products per minute of wet grinding. Agate grinding elements were abraded at ⩽6 mg min-1. The abrasion products and grinding elements were analyzed by x-ray fluorescence, spark-source mass spectrometry and neutron activation analysis. Contamination in trace element analysis of geological materials is likely to be negligible for agate grinding elements and, except for a few transition metals, also for corundum grinding elements. Contamination of typical biological samples is significant for a few elements even when agate elements are used, and is absolutely prohibitive for trace analysis when corundum elements are used.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93724-9
|
|
|
“Selenium content and speciation in environmental waters determied by X-ray fluorescence spectroscopy”. Robberecht H, Van Grieken R page 362 (1980).
Keywords: H3 Book chapter; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Selenium content of soils and rye grass (Lolium multiflorum) in Belgium”. vanden Berghe D, Deelstra H, Robberecht H, Van Grieken R page 85 (1981).
Keywords: H3 Book chapter; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Selenium gehalten van levensmiddelen geconsumeerd in België”. Robberecht H, Deelstra H, vanden Berghe D, Van Grieken R, Revue des fermentations et des industries alimentaires 37, 188 (1983)
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Selenium in environmental and drinking waters of Belgium”. Robberecht H, Van Grieken R, van Sprundel M, vanden Berghe D, Deelstra H, The science of the total environment 26, 163 (1983). http://doi.org/10.1016/0048-9697(83)90109-2
Abstract: The tetravalent and hexavalent selenium content of water samples can be determined by conventional energy-dispersive X-ray fluorescence after different preconcentration steps. Selenium values of nearly three-hundred different environmental and drinking water samples in Belgium are reported. The results are quite low, ranging from the detection limits up to 1 μg l−1. The concentration levels are compared to literature data and the speciation is discussed. The contribution of drinking water to the daily intake of selenium in Belgium ranges from less than 0.2 to 5%.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(83)90109-2
|
|
|
“Selenium in environmental waters : determination, speciation and concentration levels”. Robberecht H, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 29, 823 (1982). http://doi.org/10.1016/0039-9140(82)80252-X
Abstract: This article reviews the different methods used for the determination of selenium species in all types of environmental waters. Basic difficulties are discussed and the efficiency of the methods is explained in view of the sub-μg/1. concentration levels. Special attention is paid to preconcentration steps. Published data on speciation and concentration levels in various water samples are critically reviewed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80252-X
|
|
|
“Selenium in the Belgian soils and its uptake by rye-grass”. Robberecht H, vanden Berghe D, Deelstra H, Van Grieken R, The science of the total environment 25, 61 (1982). http://doi.org/10.1016/0048-9697(82)90042-0
Abstract: Data obtained by atomic absorption spectroscopy showed a selenium concentration of only 0.11 ppm as an average value for the most representative agricultural soils in Belgium. The selenium content in rye-grass grown on different soil types was between 0.05 and 0.11 ppm, and positively correlated with the soil selenium level. Addition of selenium in the form of selenite to the different soil types resulted in an increased selenium uptake by the plant. The ultimate concentration in the plant depended on the structural and chemical composition of the soil. Twelve other elements were determined in the soils by energy-dispersive X-ray fluorescence; none showed a strong correlation with the soil selenium content or with the selenium uptake by ryegrass.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(82)90042-0
|
|
|
“Serum bromine levels in psoriasis”. Shani J, Barak S, Ram M, Levi D, Pfeifer Y, Schlesinger T, Avrach WW, Robberecht H, Van Grieken R, Pharmacology 25, 297 (1982). http://doi.org/10.1159/000137756
Abstract: Serum bromine levels in psoriatic Danes increased 2- to 3-fold during a 4-week bathing course in the Dead Sea. This increase correlated well with the improvement in their clinical and psychic condition. Serum bromine levels in psoriatic Danes were somewhat lower than those in healthy subjects residing in Denmark, but the difference was not significant. Israelis working in the open air in the Dead Sea area (air bromine 20-fold higher than in Jerusalem) had higher bromine levels than psoriatic or healthy Israelis residing in Jerusalem or healthy Israelis working in air-conditioned rooms in the Dead Sea area (p < 0.05), but those levels were still within the normal range. As our animal experimentation indicates that the skin is a major target organ for 82Br, applied either by bathing or as an aerosol, we conclude that the higher bromine levels noticed in the psoriatic Danes after their 4-week stay at the Dead Sea may be equally due to their contact with the bromine-containing aerosol and the high bromine level of the Dead Sea waters.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1159/000137756
|
|
|
“Skin penetration of minerals in psoriatics and guinea-pigs bathing in hypertonic salt solutions”. Shani J, Barak S, Levi D, Ram M, Schachner ER, Schlesinger T, Robberecht H, Van Grieken R, Avrach WW, Pharmacological research communications 17, 501 (1985). http://doi.org/10.1016/0031-6989(85)90123-7
Abstract: Penetration of electrolytes through the human skin was measured in healthy volunteers and in psoriatic patients after bathing in the Dead-Sea or in simulated bath-salt solutions. Significant increases in the levels of serum Br, Rb, Ca and Zn were noticed only in the psoriatic patients after daily bathing in the Dead-Sea for a 4-week regimen. Guinea-pigs bathed in simulated Dead-Sea bath-salt solutions containing radionuclides of Ca, Mg, K and Br. Traces of each radionuclide were detected in the blood and in some internal organs after 60 minutes of bathing. The radionuclides showed a physiological pattern in their organ distribution. Even though the whole investigation was carried out in hypertonic solutions, there is a definite penetration of salts through healthy (human and guinea-pigs) and damaged (psoriatic) epidermis. This finding suggests that improvement of the psoriatic condition after bathing in the Dead-Sea, may be partly attributed (in addition to ultraviolet irradiation) to the minerals' effect on the psoriatic skin.
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0031-6989(85)90123-7
|
|
|
“Spectrometric determination of silicon in food and biological samples: an interlaboratory trial”. van Dyck K, Robberecht H, van Cauwenbergh R, Deelstra H, Arnaud J, Willemyns L, Benijts F, Centeno JA, Taylor H, Soares ME, Bastos ML, Ferreira MA, d'Haese PC, Lamberts LV, Hoenig M, Knapp G, Lugowski SJ, Moens L, Riondato J, Van Grieken R, Claes M, Verheyen R, Clement L, Uytterhoeven M, Journal of analytical atomic spectrometry 15, 735 (2000). http://doi.org/10.1039/B000572J
Abstract: Accuracy and precision of silicon determination in biological matrices (serum, urine, water, beer and spinach) by spectrometric techniques (when necessary after acid destruction) were assessed by means of a collaborative interlaboratory trial. The trial was set up in accordance with ISO 5725-2 (1994). The relative overall repeatability standard deviation was acceptable. It varied between 4% for spinach powder (mean content: 176 mg kg(-1)) and 11% for serum (mean content: 5.33 mg L-1). On the other hand, the relative overall between-laboratory standard deviation was found to vary from a satisfactorily 15% for spinach after destruction (mean content: 3.32 mg L-1) to an unacceptable 107% for spinach powder (mean content: 176 mg kg(-1)). The overall conclusion of the trial was that silicon determination in biological matrices can properly be performed by spectrometric techniques. However, when sample pretreatment (i.e., acid destruction) is needed prior to silicon determination problems still remain.
Keywords: A1 Journal article; Behavioural Ecology & Ecophysiology; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B000572J
|
|
|
“Sub-part-per-billion determination of total dissolved selenium and selenite in environmental waters by X-ray fluorescence spectrometry”. Robberecht HJ, Van Grieken RE, Analytical chemistry 52, 449 (1980). http://doi.org/10.1021/AC50053A017
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50053A017
|
|