“Use of solid-phase microextraction for the detection of acetic acid by ion-trap gas chromatography-mass spectrometry and application to indoor levels in museums”. Godoi AFL, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1067, 331 (2005). http://doi.org/10.1016/J.CHROMA.2004.12.054
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2004.12.054
|
“Methods, fluxes and sources of gas phase alkyl nitrates in the coastal air”. Dirtu AC, Buczyńska AJ, Godoi AFL, Favoreto R, Bencs L, Potgieter-Vermaak SS, Godoi RHM, Van Grieken R, Van Vaeck L, Environmental monitoring and assessment 186, 6445 (2014). http://doi.org/10.1007/S10661-014-3866-7
Abstract: The daily and seasonal atmospheric concentrations, deposition fluxes and emission sources of a few C3C9 gaseous alkyl nitrates (ANs) at the Belgian coast (De Haan) on the Southern North Sea were determined. An adapted sampler design for low- and high-volume air-sampling, optimized sample extraction and clean-up, as well as identification and quantification of ANs in air samples by means of gas chromatography mass spectrometry, are reported. The total concentrations of ANs ranged from 0.03 to 85 pptv and consisted primarily of the nitro-butane and nitro-pentane isomers. Air mass backward trajectories were calculated by the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model to determine the influence of main air masses on AN levels in the air. The shorter chain ANs have been the most abundant in the Atlantic/Channel/UK air masses, while longer chain ANs prevailed in continental air. The overall mean N fluxes of the ANs were slightly higher for summer than those for winter-spring, although their contributions to the total nitrogen flux were low. High correlations between AN and HNO2 levels were observed during winter/spring. During summer, the shorter chain ANs correlated well with precipitation. Source apportionment by means of principal component analysis indicated that most of the gas phase ANs could be attributed to traffic/combustion, secondary photochemical formation and biomass burning, although marine sources may also have been present and a contributing factor.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
DOI: 10.1007/S10661-014-3866-7
|
“The feasibility of Fourier transform laser microprobe mass spectrometry for applications of local and surface analysis”. Struyf H, van Roy W, Van Vaeck L, Van Grieken R, Caravatti P, Proceedings of the European FTMS Workshop (1994)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Fast chromatographic determination of polycyclic aromatic hydrocarbons in aerosol samples from sugar cane burning”. Godoi AFL, Ravindra K, Godoi RHM, Andrade SJ, Santiago-Silva M, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1027, 49 (2004). http://doi.org/10.1016/J.CHROMA.2003.10.048
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2003.10.048
|
“Desorption-ionization of inorganic compounds in Fourier transform laser microprobe mass spectrometry with external ion source”. Struyf H, Van Vaeck L, Van Grieken R, Rapid communications in mass spectrometry 10, 551 (1996). http://doi.org/10.1002/(SICI)1097-0231(19960331)10:5<551::AID-RCM414>3.0.CO;2-S
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-0231(19960331)10:5<551::AID-RCM414>3.0.CO;2-S
|
“Assessment of local analysis by Fourier transform laser microprobe mass spectrometry with external ion source”. van Roy W, Struyf H, Kennis P, Van Vaeck L, Van Grieken R, Andrle C, Microchimica acta 120, 121 (1995). http://doi.org/10.1007/BF01244426
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01244426
|
“Application of low-pressure gas chromatography-io-trap mass spectrometry to the analysis of the eseential oil of Turnera diffusa (Ward.) Urb”. Godoi AFL, Vilegas W, Godoi RHM, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1027, 127 (2004). http://doi.org/10.1016/J.CHROMA.2003.08.079
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2003.08.079
|
“The analysis of volatile siloxanes in waste activated sludge”. Dewil R, Appels L, Baeyens J, Van Vaeck L, Buczyńska A, Talanta 74, 14 (2007). http://doi.org/10.1016/J.TALANTA.2007.05.041
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.05.041
|
“TOF-SIMS analysis of carbocyanine dyes adsorbed on silver substrates”. Lenaerts J, Verlinden G, van Vaeck L, Gijbels R, Geuens I, , 115 (2000)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Structural characterization of organic molecules by laser mass spectrometry”. van Vaeck L, van Roy W, Gijbels R, Adams F Wiley, New York, page 177 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Static secondary ion mass spectrometry (S-SIMS): part 1: methodology and structural interpretation”. van Vaeck L, Adriaens A, Gijbels R, Mass spectrometry reviews 18, 1 (1999)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 9.373
Times cited: 112
|
“Secondary ion formation of low molecular weight organic dyes in time-of-flight static secondary ion mass spectrometry”. Lenaerts J, van Vaeck L, Gijbels R, Rapid communications in mass spectrometry 17, 2115 (2003). http://doi.org/10.1002/rcm.1160
Abstract: Time-of-flight static secondary ion mass spectrometry (TOF-S-SIMS) was used to characterize thin layers of oxy- and thiocarbocyanine dyes on Ag and Si. Apart from adduct ions a variety of structural fragment ions were detected for which a fragmentation pattern is proposed. Peak assignments were confirmed by comparing spectra of dyes with very similar structures. All secondary ions were assigned with a mass accuracy better than 50 ppm. The intensity of molecular ions as well as fragment ions has been studied as a function of the type of organic dye, the substrate, the layer thickness and the type of primary ion. A large yield difference of two orders of magnitude was observed between the precursor ions of cationic carbocyanine dyes and the protonated molecules of the anionic dyes. Fragment ions, on the other hand, yielded similar intensities for both types of dye. As the dye layers deposited on an Ag substrate yielded higher secondary ion intensities than those deposited on a Si substrate, the Ag metal clearly acts as a promoting agent for secondary ion formation. The effect was more pronounced for precursor signals than for fragment ions. The promoting effect decreased as the deposited layer thickness of the organic dye layer was increased. Copyright (C) 2003 John Wiley Sons, Ltd.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.998
Times cited: 10
DOI: 10.1002/rcm.1160
|
“Observation of Sb203 nanocrystals in SiO2 after Sb ion implantation”. Ignatova VA, Lebedev OI, Wätjen U, van Vaeck L, van Landuyt J, Gijbels R, Adams F, Microchimica acta 139, 77 (2002). http://doi.org/10.1007/s006040200043
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.58
Times cited: 3
DOI: 10.1007/s006040200043
|
“A new electrostatic transfer line for improved transmission in Fourier transform laser microprobe mass spectrometry with external ion source”. van Vaeck L, van Espen P, Gijbels R, Baykut G, Laukien FH, European mass spectrometry 6, 277 (2000). http://doi.org/10.1255/ejms.342
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Times cited: 10
DOI: 10.1255/ejms.342
|
“Molecular speciation of inorganic mixtures by Fourier transform laser microprobe mass sepctrometry”. Ignatova VA, van Vaeck L, Gijbels R, Adams F, International journal of mass spectrometry 225, 213 (2003). http://doi.org/10.1016/S1387-3806(02)01116-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.702
Times cited: 9
DOI: 10.1016/S1387-3806(02)01116-8
|
“Molecular information in static SIMS for the speciation of inorganic compounds”. van Ham R, Adriaens A, van Vaeck L, Gijbels R, Adams F, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 161/163, 245 (2000). http://doi.org/10.1016/S0168-583X(99)00750-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.109
Times cited: 19
DOI: 10.1016/S0168-583X(99)00750-8
|
“Modeling of the sputtering process of cubic silver halide microcrystals and its relevance in depth profiling by secondary ion-mass spectrometry (SIMS)”. Lenaerts J, Verlinden G, Ignatova VA, van Vaeck L, Gijbels R, Geuens I, Fresenius' journal of analytical chemistry 370, 654 (2001). http://doi.org/10.1007/s002160100880
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 3
DOI: 10.1007/s002160100880
|
“Microprobe speciation analysis of inorganic solids by Fourier transform laser mass spectrometry”. Poels K, van Vaeck L, Gijbels R, Analytical chemistry 70, 504 (1998). http://doi.org/10.1021/ac9709108
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 32
DOI: 10.1021/ac9709108
|
“Metal and composite nanocluster precipitate formation in silicon dioxide implanted with Sb+ ions”. Ignatova VA, Lebedev OI, Watjen U, van Vaeck L, van Landuyt J, Gijbels R, Adams F, Journal of applied physics 92, 4336 (2002). http://doi.org/10.1063/1.1508425
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 5
DOI: 10.1063/1.1508425
|
“Lasers in mass spectrometry: organic and inorganic instrumentation”. van Vaeck L, van Roy W, Gijbels R, Adams F Wiley, New York, page 7 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Laser microprobe mass spectrometry: principle and applications in biology and medicine”. van Vaeck L, Poels K, de Nollin S, Hachimi A, Gijbels R, Cell biology international 21, 635 (1997). http://doi.org/10.1006/cbir.1997.0198
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.831
Times cited: 6
DOI: 10.1006/cbir.1997.0198
|
“Laser microprobe mass spectrometry: local surface analysis of organic and inorganic compounds”. van Vaeck L, van Roy W, Struyf H, Poels K, Gijbels R Vch, Weinheim, page 354 (1997).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Laser microprobe mass spectrometry in biology and biomedicine”. Eeckhaoudt S, van Vaeck L, Gijbels R, van Grieken RE, Scanning microscopy S8, 335 (1994)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, van Grieken R, Gijbels R, Caravatti P, Analytica chimica acta 283, 139 (1993). http://doi.org/10.1016/0003-2670(93)85216-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 17
DOI: 10.1016/0003-2670(93)85216-7
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, Gijbels R, Caravatti P San Francisco Press, San Francisco, Calif., page 595 (1993).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Laser ionization mass-spectrometry for the characterization of solid materials”. van Vaeck L, Vanroy W, Gijbels R, Analusis : chimie analytique, méthodes physiques d'analyse, composition de la matière 20, S29 (1992)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Laser ionization mass spectrometry for the characterization of solid materials”. van Vaeck L, van Roy W, Gijbels R, Analusis : chimie analytique, méthodes physiques d'analyse, composition de la matière 21, 53 (1993)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 10
|
“Imaging TOF-SIMS for the surface analysis of silver halide microcrystals”. Lenaerts J, Gijbels R, van Vaeck L, Verlinden G, Geuens I, Applied surface science 203/204, 614 (2003). http://doi.org/10.1016/S0169-4332(02)00777-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 7
DOI: 10.1016/S0169-4332(02)00777-8
|
“Identification des substances inorganiques et organiques en surface des solides par la microsonde laser”. van Vaeck L, Gijbels R Eyrolles, Paris, page 27 (1992).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“A Fourier transform laser microprobe mass spectrometer with external ion source for organic and inorganic surface and micro-analysis”. van Roy W, Struyf H, van Vaeck L, Gijbels R, Caravatti P Wiley, Chichester, page 463 (1994).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|