“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
“Determination of barium, lanthanum, cerium and neodymium in lateritic materials by various energy-dispersive X-ray fluorescence techniques and neutron activation analysis”. Labrecque JJ, Beusen JM, Van Grieken RE, X-ray spectrometry 15, 13 (1986). http://doi.org/10.1002/XRS.1300150105
Abstract: A comparison of four methods for the determination of barium, lanthanum, cerium and neodymium in lateritic materials from Brazil is presented. Three of the methods were based on x-ray fluorescence (XRF) spectroscopy: two by radioisotope excitation (Co-57 and Am-241) and one by secondary target XRF (a molybdenum target with a tungsten anode). The other method was based on neutron activation analysis employing both a Ge(Li) coaxial detector and a high-purity germanium detector. The results from these four methods were similar for lanthanum, cerium and neodymium, but for barium at low concentrations (<500 ppm) the neutron activation and the secondary target XRF methods were not suitable. Data on the precision and accuracy of these methods using a series of standard reference rocks are given. The advantages and limitations of each of these methods with respect to the analysis of lateritic materials are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150105
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
“Damage functions and mechanism equations derived from limestone weathering in field exposure”. Delalieux F, Cardell-Fernandez C, Torfs K, Vleugels G, Van Grieken RE, Water, air and soil pollution 139, 75 (2002). http://doi.org/10.1023/A:1015827031669
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/A:1015827031669
|
“Effects of titanium dioxide industry waste dumping on sea water chemistry”. Roekens EJ, Van Grieken RE, Water research 17, 1385 (1983). http://doi.org/10.1016/0043-1354(83)90268-3
Abstract: An investigation was made to determine the influence of the dumping of a 1000 ton day−1, on the average, of acid-iron waste from the titanium dioxide industry into the shallow but turbulent Southern Bight of the North Sea. This waste contains some 20% sulfuric acid and 2% iron. After the passage of the barge that discharges 10 ton of waste min−1 into its wake, the vertical and horizontal distributions of the pH, iron-concentration and turbidity were measured as a function of time. It appeared that a few seconds after the discharge and for a very brief period, the pH was down to approx. 4 and the Fe-concentration was 13 mg l−1. More than 1 min after the discharge a pH below 6 and an iron-level above 3 mg l−1 could not be detected anywhere. The measured factor for waste dilution by sea water, based on the observed acid and iron concentration in the waste and in the discharge track, were around 5000 after 5 min, 9000 after 10 min and 80,000 after 20 min. Before and long after the dumping, the total iron-concentration in this Southern Bight area was around 100 μg l−1, but this high level might be due to natural causes.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0043-1354(83)90268-3
|
“Elemental analysis of aerosol-size fractions by proton-induced X-ray-emission”. Johansson TB, Nelson JW, Van Grieken RE, Winchester JW, Transactions of the American Nuclear Society 17, 103 (1973)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“The elemental composition of airborne particulate matter in the Atacama desert, Chile”. Rojas CM, Figueroa L, Janssens KH, Van Espen PE, Adams FC, Van Grieken RE, The science of the total environment 91, 251 (1990). http://doi.org/10.1016/0048-9697(90)90302-B
Abstract: Air particulate samples were collected at Chapiquiña near Arica (Chile) with a six-stage cascade impactor for about 17-day periods during a 31 month interval. Sixteen elements were determined by energy dispersive X-ray fluorescence analysis, and the elemental concentrations were subjected to principal factor analysis. The variability with time of the coarse particles was described by two factors both related to soil dispersion, whereas the fine particle variations could be explained by a third factor related to marine influence. Enrichment factors were compared with those obtained in other remote continental areas, in particular those of air particulate matter sampled at Chacaltaya, Bolivia. Results point to a negligible anthropogenic influence.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90302-B
|
“Characterization of the weathering crust of various historical buildings in Belgium”. Leysen LA, Roekens EJ, Van Grieken RE, De Geyter G, The science of the total environment 90, 117 (1990). http://doi.org/10.1016/0048-9697(90)90190-6
Abstract: A variety of samples, collected from different historical buildings and monuments throughout Belgium, were thoroughly studied, using several trace- and micro-analysis techniques. Thin sections of stones and mortar joints were characterized by means of electron probe X-ray microanalysis (EPXMA). The morphological appearance of the surface weathering crust and the possible presence of non-innate particles in the crust were elucidated using petrographical and electron microscopy. Quantitative characterization of the total chemical composition of the crust surface layer and underlying layer was performed by energy-dispersive X-ray fluorescence, and by ion chromatography and atomic absorption spectrometry for the leachable components. Special attention was also paid to the chemical composition of rain and air at the particular sampling sites. The element distribution in the transition zone between the weathering crust and the original stone material was found to vary greatly amongst the different samples analyzed. Detailed EPXMA measurements on pieces of the weathering crust showed remarkable differences in morphology and composition between the surface and the underlying layer, and provided information about the presence of fly-ash and soil dust particles in the crust. Except for crusts from the city of Brussels, which were all very high in sulphate, the samples appeared to contain very variable sulphate contents; very local micro-climate and environmental conditions at a particular site are more important in determining the weathering condition of the building stones than the local air pollution situation. Bulk analytical characterization further showed, in all the crust samples studied, a very small contribution of nitrogen- and chlorine-containing weathering products, in contrast to sulphur-containing weathering salts.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90190-6
|
“Iron, copper, zinc and lead in hair from Sudanese populations of different age groups”. Eltayeb MAH, Van Grieken RE, The science of the total environment 95, 157 (1990). http://doi.org/10.1016/0048-9697(90)90061-X
Abstract: Energy-dispersive X-ray fluorescence was used for the analysis of hair samples from three different age groups of the Sudanese population. Hair samples were digested in a mixture of nitric and perchloric acids and the metals were then precipitated with ammonium pyrrolidine dithiocarbamate. The variations of the Fe, Cu, Zn and Pb content of hair with age were investigated. The averages of the elemental concentrations in each age group were compared with the other age groups and with literature values. The correlation of each pair of elements in the hair samples was also investigated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90061-X
|
“Size-differentiated composition of aerosols in Khartoum, Sudan”. Eltayeb MAH, van Espen PJ, Cafmeyer J, Van Grieken RE, Maenhaut W, The science of the total environment 120, 281 (1992). http://doi.org/10.1016/0048-9697(92)90062-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0048-9697(92)90062-W
|
“Influence of fixation procedures on the microanalysis of lead-induced intranuclear inclusions in rat kidney”. Vandeputte DF, Jacob WA, Van Grieken RE, The journal of histochemistry and cytochemistry 38, 331 (1990). http://doi.org/10.1177/38.3.2154517
Abstract: Using Laser Microprobe Mass Analysis (LAMMA), we studied the chemical composition of lead-induced intranuclear inclusions in rat kidney tissue prepared by three different wet chemical fixation procedures for transmission electron microscopy. Fixation with glutaraldehyde-Na2S gave the same results as fixation with glutaraldehyde only: a high lead concentration could be detected. Therefore, for lead strongly bound to proteins, precipitation procedures are not essential. Post-fixation with osmium tetroxide drastically changed the composition of the inclusions: the lead concentration decreased substantially, while sodium, calcium, and barium were introduced. The osmium tetroxide fixative was found to be the source of the contamination. It also contained aluminum, and we suggest that other proteins (e.g., in neurofibrillary tangles) might be able to take up Al out of solution and that care must be exercised in interpreting the microanalytical results of osmium-fixed material. For the microanalysis of the lead inclusions, fixation with glutaraldehyde only provides a good compromise between preservation of the ultrastructure and maintenance of the element distribution.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1177/38.3.2154517
|
“Co-crystallization with 1-(2-pyridylazo)-2-naphthol, and X-ray fluorescence, for trace metal analysis of water”. Vanderstappen MG, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 25, 653 (1978). http://doi.org/10.1016/0039-9140(78)80166-0
Abstract: Adding 20mg of 1-(2-pyridylazo)-2-naphthol (PAN) to a water sample at 70°, and filtering off the precipitate after cooling, gives efficient preconcentration prior to X-ray fluorescence analysis of water. Up to the capacity of about 100 μeq of PAN used, the trace metal recoveries are around 90% or higher for Cr3+, Mn2+, Ni2+, Cu2+, Zn2+, Hg2+ and Eu3+, and above 70% for many other ions. The recovery yields usually do not vary critically with pH in the neutral pH-range, and are practically independent of the sample salinity, sample volume and trace-metal concentration. Enrichment factors as high as 2 × 105 can be achieved. Counting statistics would then allow detection limits of 0.03 ppM. The blank levels in commercial PAN, however, lead to typical detection limits of about 1 ppm. The coefficient of variation is typically in the 510% range at the 10-ppM level. The accuracy and applicability of the procedure are illustrated by comparative analyses on samples of synthetic solutions, river and drinking water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(78)80166-0
|
“Losses of metabolically incorporated selenium in common digestion procedures for biological material”. Robberecht HJ, Van Grieken RE, Van den Bosch PA, Deelstra H, vanden Berghe D, Talanta : the international journal of pure and applied analytical chemistry 29, 1025 (1982). http://doi.org/10.1016/0039-9140(82)80244-0
Abstract: Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80244-0
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
“Laser microprobe mass analysis (LAMMA) to verify the aluminon staining of bone”. Verbueken AH, van de Vijver FL, Visser WJ, Van Grieken RE, de Broe ME, Stain technology 61, 287 (1986). http://doi.org/10.3109/10520298609109955
Abstract: Triammonium aurin tricarboxylate (aluminon) has been used to localize aluminum in 2 μm sections of undecalcified, methyl methacrylate embedded bone obtained from patients with terminal chronic renal failure. Aluminum appeared in four cases as bright red lines at the mineralized-bone boundary. In two cases, however, purplish lines were found and one patient showed red as well as purplish lines. Laser microprobe mass analysis (LAMMA) identified aluminum at the location of the red lines and both aluminum and iron at the purplish lines. Furthermore, both iron and aluminum were found in histiocytic bone marrow cells, which showed brownish aluminon staining. It appears that when aluminum and iron occur together, aluminon staining may yield aberrant results. This study shows that LAMMA can be used for the identification of elements sought by histochemical methods and thus permits the evaluation of their staining effects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.3109/10520298609109955
|
“Comparison of grazing-exit particle-induced X-ray emission with other related methods”. Tsuji K, Huisman M, Spolnik Z, Wagatsuma K, Mori Y, Van Grieken RE, Vis RD, Spectrochimica acta: part B : atomic spectroscopy 55, 1009 (2000). http://doi.org/10.1016/S0584-8547(00)00148-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(00)00148-8
|
“Enhancement of electron-induced X-ray intensity for single particles under grazing-exit conditions”. Tsuji K, Spolnik Z, Wagatsuma K, Zhang J, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1243 (1999). http://doi.org/10.1016/S0584-8547(99)00073-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00073-7
|
“Enhancement of X-ray fluorescence intensity from an ultra-thin sandwiched layer at grazing-emission angles”. Tsuji K, Takenaka H, Wagatsuma K, de Bokx PK, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1881 (1999). http://doi.org/10.1016/S0584-8547(99)00143-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00143-3
|
“Molecular ion distributions in laser microprobe mass-spectrometry of calcium-oxide and calcium salts”. Bruynseels FJ, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 38, 853 (1983). http://doi.org/10.1016/0584-8547(83)80184-0
Abstract: Laser Microprobe Mass Spectrometry (LAMMA) is used to examine micrometric particles of calcium oxyanion salts (CaCO3, CaSO4, CaSO4·2H2O) and calcium oxide, in both the positive and negative ion mode. The major molecular ions, appearing in the positive mass spectrum, can be divided into three series, namely CamOm-1+, (CaO)m+ and (CaO)mH+ (m = 1-4). In the case of the former two series the relative intensities of the mass peaks as a function of the fragment valence K = (1 + 2n)/m, for CamOn+, can be fitted to a Gaussian distribution curve, as was earlier demonstrated for secondary ion mass spectrometry. The high stability of the (CaO)mH+ series can be explained by the favourable fragment valence of +2 corresponding to the usual oxidation state of calcium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0584-8547(83)80184-0
|
“Quantification in grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken RE, de Bokx PK, Urbach HP, Spectrochimica acta: part B : atomic spectroscopy 54, 1525 (1999). http://doi.org/10.1016/S0584-8547(99)00051-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00051-8
|
“Micro-analysis of individual aerosol particles using electron, proton and laser beams”. de Bock LA, Jambers W, Van Grieken RE, South African journal of chemistry = Suid-Afrikaanse tydskrif vir chemie 49, 65 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Study of the Antarctic aerosol using X-ray fluorescence and single particle analysis”. Rojas CM, Van Grieken RE, Cantillano ME, Scientific series of the Chilean Antarctic Institute (Ser. Cinet. INACH) 42, 37 (1992)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Laser microprobe mass spectrometry in biology and biomedicine”. Eeckhaoudt S, van Vaeck L, Gijbels R, van Grieken RE, Scanning microscopy S8, 335 (1994)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Electron probe micro-analysis and laser microprobe mass analysis of material, leached from a limestone cathedral”. Leysen LA, De Waele JK, Roekens EJ, Van Grieken RE, Scanning microscopy 1, 1617 (1987)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Reviews in analytical chemistry 56, 241r (1984)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Localization of lead in cultured tooth germs by laser microprobe micro-analysis”. Ameloot PC, Vandeputte DF, Van Grieken RE, Coomans D, Proceedings of the Finnish Dental Society 83, 225 (1987)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Analysis of X-ray spectra excited by X rays, electrons, and protons in monazite”. Annegarn HJ, Madiba CCP, Sellschop JPF, Genz H, Hoffmann DHH, Low W, Richter A, Van Grieken RE, Physical review : C : nuclear physics 16, 379 (1977). http://doi.org/10.1103/PHYSREVC.16.379
Abstract: Mineral monazite from Malaysia has been investigated by energy dispersive x-ray analysis employing three different methods: x-ray, relativistic electron and proton induced excitation. An upper limit of 15 ppm has been placed on the possible concentration of the superheavy element with Z=126.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1103/PHYSREVC.16.379
|
“Trace element composition of Zaire suspended sediments”. Martin J-M, Thomas AJ, Van Grieken RE, Netherlands journal of sea research 12, 414 (1978). http://doi.org/10.1016/0077-7579(78)90043-1
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(78)90043-1
|
“Composition and size of individual particles from a gold mine atmosphere”. Annegarn HJ, Storms H, Van Grieken RE, Booth-Jones PA, Mining science &, technology 5, 111 (1987). http://doi.org/10.1016/S0167-9031(87)90345-8
Abstract: Airborne dust particles were collected in a return airway of a South African gold mine using a 7-stage, single-orifice cascade impactor. Between 70 and 130 individual particles were analysed on each stage using automated electron-probe x-ray microanalysis (EPXMA). Particle size and shape parameters are given for different classes of particles sorted by elemental composition. Silicon-rich particles are the most abundant overall, while chlorine-rich particles dominate (up to 80%) in the range 0.21.0 μm. It is shown that EPXMA characterisation of particles can be used to infer relative contributions of various particle sources and dust generating processes to the total dust concentrations in mine atmospheres. An understanding of the nature and source of particles is essential for any source control strategy. We conclude that the EPXMA technique merits inclusion in the repertoire of techniques used for characterising underground dust.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0167-9031(87)90345-8
|
“Applying digital image processing to SEM-EDX and BSE images to determine and quantify porosity and salts with depth in porous media”. Cardell C, Yebra A, Van Grieken RE, Microchimica acta 140, 9 (2002). http://doi.org/10.1007/S006040200063
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040200063
|