“X-ray spectrometry”. Török SB, Van Grieken RE, Analytical chemistry 64r, 180 (1992)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 62, 101r (1990). http://doi.org/10.1021/AC00211A001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00211A001
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 60, 28r (1988). http://doi.org/10.1021/AC00163A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00163A002
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 58, 279r (1986). http://doi.org/10.1021/AC00296A019
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00296A019
|
|
|
“Micro to nano : multiscale IR analyses reveal zinc soap heterogeneity in a 19th-century painting by Corot”. Ma X, Pavlidis G, Dillon E, Beltran V, Schwartz JJ, Thoury M, Borondics F, Sandt C, Kjoller K, Berrie BH, Centrone A, Analytical chemistry 94, 3103 (2022). http://doi.org/10.1021/ACS.ANALCHEM.1C04182
Abstract: Formation and aggregation of metal carboxylates (metal soaps) can degrade the appearance and integrity of oil paints, challenging efforts to conserve painted works of art. Endeavors to understand the root cause of metal soap formation have been hampered by the limited spatial resolution of Fourier transform infrared microscopy (mu-FTIR). We overcome this limitation using optical photothermal infrared spectroscopy (O-PTIR) and photothermal-induced resonance (PTIR), two novel methods that provide IR spectra with approximate to 500 and approximate to 10 nm spatial resolutions, respectively. The distribution of chemical phases in thin sections from the top layer of a 19th-century painting is investigated at multiple scales (mu-FTIR approximate to 10(2) mu m(3), O-PTIR approximate to 10(-1) mu m(3), PTIR approximate to 10(-5) mu m(3)). The paint samples analyzed here are found to be mixtures of pigments (cobalt green, lead white), cured oil, and a rich array of intermixed, small (often << 0.1 mu m(3)) zinc soap domains. We identify Zn stearate and Zn oleate crystalline soaps with characteristic narrow IR peaks (approximate to 1530-1558 cm(-1)) and a heterogeneous, disordered, water-permeable, tetrahedral zinc soap phase, with a characteristic broad peak centered at approximate to 1596 cm(-1). We show that the high signal-to-noise ratio and spatial resolution afforded by O-PTIR are ideal for identifying phase-separated (or locally concentrated) species with low average concentration, while PTIR provides an unprecedented nanoscale view of distributions and associations of species in paint. This newly accessible nanocompositional information will advance our knowledge of chemical processes in oil paint and will stimulate new art conservation practices.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1021/ACS.ANALCHEM.1C04182
|
|
|
“Chemical mapping of the degradation of geranium lake in paint cross sections by MALDI-MSI”. Alvarez-Martin A, Quanico J, Scovacricchi T, Avranovich Clerici E, Baggerman G, Janssens K, Analytical chemistry 95, 18215 (2023). http://doi.org/10.1021/ACS.ANALCHEM.3C03992
Abstract: Matrix assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) has become a powerful method to extract spatially resolved chemical information in complex materials. This study provides the first use of MALDI-MSI to define spatial–temporal changes in oil paints. Due to the highly heterogeneous nature of oil paints, the sample preparation had to be optimized to prevent molecules from delocalizing. Here, we present a new protocol for the layer-specific analysis of oil paint cross sections achieving a lateral resolution of 10 μm and without losing ionization efficiency due to topographic effects. The efficacy of this method was investigated in oil paint samples containing a mixture of two historic organic pigments, geranium lake and lead white, a mixture often employed in the work of painter Vincent Van Gogh. This methodology not only allows for spatial visualization of the molecules responsible for the pink hue of the paint but also helps to elucidate the chemical changes behind the discoloration of paintings with this composition. The results demonstrate that this approach provides valuable molecular compositional information about the degradation pathways of pigments in specific paint layers and their interaction with the binding medium and other paint components and with light over time. Since a spatial correlation between molecular species and the visual pattern of the discoloration pattern can be made, we expect that mass spectrometry imaging will become highly relevant in future degradation studies of many more historical pigments and paints.
Keywords: A1 Journal article; Antwerp X-ray Imaging and Spectroscopy (AXIS); Ecosphere
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.3C03992
|
|
|
“Dual microfluidic sensor system for enriched electrochemical profiling and identification of illicit drugs on-site”. Steijlen ASM, Parrilla M, Van Echelpoel R, De Wael K, Analytical chemistry 96, 590 (2024). http://doi.org/10.1021/ACS.ANALCHEM.3C05039
Abstract: Electrochemical sensors have emerged as a new analytical tool for illicit drug detection to facilitate ultrafast and accurate identification of suspicious compounds on-site. Drugs of abuse can be identified using their unique voltammetric fingerprint at a given pH. Today, the right buffer solution is manually selected based on drug appearance, and in some cases, a consecutive analysis in two different pH solutions is required. In this work, we present a disposable microfluidic multichannel sensor system that automatically records fingerprints in two pH solutions (e.g., pH 5 and pH 12). This system has two advantages. It will overcome the manual selection of a buffer solution at the right pH, decrease analysis time, and minimize the risk of human errors. Second, the combination of two fingerprints, the superfingerprint, contains more detailed information about the samples, which enhances the selectivity of the analytical technique. First, real-time pH measurements proved that the sample can be brought to the desired pH within a minute. Subsequently, an electrochemical study on the microfluidic platform with 1 mM illicit drug standards of MDMA, cocaine, heroin, and methamphetamine showed that the characteristic voltammetric fingerprints and peak potentials are reproducible, also in the presence of common cutting agents. Finally, the microfluidic concept was validated with real confiscated samples, showing promising results for the user-friendly identification of drugs of abuse. In short, this paper presents a successful proof-of-concept study of a multichannel microfluidic sensor system to enrich the fingerprints of illicit drugs at pH 5 and pH 12, thus providing a low-cost, portable, and rapid identification system of illicit drugs with minimal user intervention.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.3C05039
|
|
|
“A 96-well LED array for multiplexed photoelectrochemical detection of nucleic acids”. Thiruvottriyur Shanmugam S, Steijlen A, Laurijssen D, Campos R, Steckel J, Daems W, Bassini S, Daems E, De Wael K, Analytical chemistry 96, 15091 (2024). http://doi.org/10.1021/ACS.ANALCHEM.4C01998
Abstract: Photoelectrochemical detection of nucleic acid-based cancer biomarkers offers opportunities for highly sensitive, selective, and fast quantitative detection using low-cost measurement instruments. In order to establish itself as a standard method for identifying and quantifying nucleic acids, we have developed a multiplexing strategy using LED technology for photoelectrochemical detection in 96 samples simultaneously. A dedicated setup based on the 96-well plate configuration with a custom-made 96-well LED array was developed. Subsequently, a proof-of-concept study was performed for three miRNAs that are associated with prostate cancer, i.e., miRNA-141, miRNA-145, and miRNA-375. First, measurements with photosensitizer chlorin e6 and redox reporter hydroquinone free in solution proved the proper functioning of the multiplexed detection. Second, the photoelectrochemical detection of the three miRNAs at 24 nM levels was successfully demonstrated. Thereafter, linear calibration curves (R2 > 0.9 for all analytes) were made with plasma spiked with 8–500 pM miRNA. This work presents the first system for multiplexed high-throughput photoelectrochemical detection, allowing it potentially to become a cost-effective and faster alternative to RT-qPCR and gene sequencing techniques in the future.
Keywords: A1 Journal article; Co-Design of Cyber-Physical Systems (Cosys-Lab); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab); Antwerp engineering, PhotoElectroChemistry & Sensing (A-PECS)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.4C01998
|
|
|
“Computer simulations of a dielectric barrier discharge used for analytical spectrometry”. Martens T, Bogaerts A, Brok W, van Dijk J, Analytical and bioanalytical chemistry 388, 1583 (2007). http://doi.org/10.1007/s00216-007-1269-0
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.431
Times cited: 28
DOI: 10.1007/s00216-007-1269-0
|
|
|
“Advantages of combined mu-XRF and mu-XRD for phase characterization of Ti-B-C ceramics compared with conventional X-ray diffraction”. Jaroszewicz J, de Nolf W, Janssens K, Michalski A, Falkenberg G, Analytical and bioanalytical chemistry 391, 1129 (2008). http://doi.org/10.1007/S00216-008-2097-6
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 7
DOI: 10.1007/S00216-008-2097-6
|
|
|
“Compositional analysis of Tuscan glass samples: in search of raw materials fingerprints”. Cagno S, Janssens K, Mendera M, Analytical and bioanalytical chemistry 391, 1389 (2008). http://doi.org/10.1007/S00216-008-1945-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 26
DOI: 10.1007/S00216-008-1945-8
|
|
|
“Euroanalysis 14: the European Conference on Analytical Chemistry”. Janssens K, van Espen P, Van 't dack L, Analytical and bioanalytical chemistry 391, 1107 (2008). http://doi.org/10.1007/S00216-008-2114-9
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 3.431
DOI: 10.1007/S00216-008-2114-9
|
|
|
“Investigating morphological changes in treated vs. untreated stone building materials by x-ray micro-CT”. Bugani S, Camaiti M, Morselli L, Van de Casteele E, Janssens K, Analytical and bioanalytical chemistry 391, 1343 (2008). http://doi.org/10.1007/S00216-008-1946-7
Keywords: A1 Journal article; Vision lab; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 25
DOI: 10.1007/S00216-008-1946-7
|
|
|
“Spatially resolved (semi)quantitative determination of iron (Fe) in plants by means of synchrotron micro X-ray fluorescence”. Terzano R, Alfeld M, Janssens K, Vekemans B, Schoonjans T, Vincze L, Tomasi N, Pinton R, Cesco S, Analytical and bioanalytical chemistry 405, 3341 (2013). http://doi.org/10.1007/S00216-013-6768-6
Abstract: Iron (Fe) is an essential element for plant growth and development; hence determining Fe distribution and concentration inside plant organs at the microscopic level is of great relevance to better understand its metabolism and bioavailability through the food chain. Among the available microanalytical techniques, synchrotron mu-XRF methods can provide a powerful and versatile array of analytical tools to study Fe distribution within plant samples. In the last years, the implementation of new algorithms and detection technologies has opened the way to more accurate (semi)quantitative analyses of complex matrices like plant materials. In this paper, for the first time the distribution of Fe within tomato roots has been imaged and quantified by means of confocal mu-XRF and exploiting a recently developed fundamental parameter-based algorithm. With this approach, Fe concentrations ranging from few hundreds of ppb to several hundreds of ppm can be determined at the microscopic level without cutting sections. Furthermore, Fe (semi)quantitative distribution maps were obtained for the first time by using two opposing detectors to collect simultaneously the XRF radiation emerging from both sides of an intact cucumber leaf.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 27
DOI: 10.1007/S00216-013-6768-6
|
|
|
“Study on the impregnation of archaeological waterlogged wood with consolidation treatments using synchrotron radiation microtomography”. Bugani S, Modugno F, Lucejko JJ, Giachi G, Cagno S, Cloetens P, Janssens K, Morselli L, Analytical and bioanalytical chemistry 395, 1977 (2009). http://doi.org/10.1007/S00216-009-3101-5
Abstract: In favourable conditions of low temperature and low oxygen concentration, archaeological waterlogged wooden artefacts, such as shipwrecks, can survive with a good state of preservation. Nevertheless, anaerobic bacteria can considerably degrade waterlogged wooden objects with a significant loss in polysaccharidic components. Due to these decay processes, wood porosity and water content increase under ageing. In such conditions, the conservation treatments of archaeological wooden artefacts often involve the replacement of water with substances which fill the cavities and help to prevent collapse and stress during drying. The treatments are very often expensive and technically difficult, and their effectiveness very much depends on the chemical and physical characteristics of the substances used for impregnation. Also important are the degree of cavity-filling, penetration depth and distribution in the structure of the wood. In this study, the distribution in wood cavities of some mixtures based on polyethylene glycols and colophony, used for the conservation of waterlogged archaeological wood, was investigated using synchrotron radiation X-ray computed microtomography (SR-A mu CT). This non-destructive imaging technique was useful for the study of the degraded waterlogged wood and enabled us to visualise the morphology of the wood and the distribution of the materials used in the wood treatments. The study has shown how deposition is strictly related to the dimension of the wooden cavities. The work is currently proceeding with the comparison of synchrotron observations with the data of the solutions viscosity and with those of the properties imparted to the wood by the treatments.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 30
DOI: 10.1007/S00216-009-3101-5
|
|
|
“Modeling plasmas in analytical chemistry—an example of cross-fertilization”. Bogaerts A, Analytical And Bioanalytical Chemistry 412, 6059 (2020). http://doi.org/10.1007/s00216-020-02587-8
Abstract: This paper gives an overview of the modeling work developed in our group in the last 25 years for various plasmas used in analytical spectrochemistry, i.e., glow discharges (GDs), inductively coupled plasmas (ICPs), and laser ablation (LA) for sample introduction in the ICP and for laser-induced breakdown spectroscopy (LIBS). The modeling approaches are briefly presented, which are different for each case, and some characteristic results are illustrated. These plasmas are used not only in analytical chemistry but also in other applications, and the insights obtained in these other fields were quite helpful for us to develop models for the analytical plasmas. Likewise, there is now a huge interest in plasma–liquid interaction, atmospheric pressure glow discharges (APGDs), and dielectric barrier discharges (DBDs) for environmental, medical, and materials applications of plasmas. The insights obtained in these fields are also very relevant for ambient desorption/ionization sources and for liquid sampling, which are nowadays very popular in analytical chemistry, and they could be very helpful in developing models for these sources as well.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.3
DOI: 10.1007/s00216-020-02587-8
|
|
|
“Unlocking the full power of electrochemical fingerprinting for on-site sensing applications”. Moro G, Barich H, Driesen K, Montiel NF, Neven L, Mendonca CD, Thiruvottriyur Shanmugam S, Daems E, De Wael K, Analytical And Bioanalytical Chemistry , 1 (2020). http://doi.org/10.1007/S00216-020-02584-X
Abstract: Electrochemical sensing for the semi-quantitative detection of biomarkers, drugs, environmental contaminants, food additives, etc. shows promising results in point-of-care diagnostics and on-site monitoring. More specifically, electrochemical fingerprint (EF)-based sensing strategies are considered an inviting approach for the on-site detection of low molecular weight molecules. The fast growth of electrochemical sensors requires defining the concept of direct electrochemical fingerprinting in sensing. The EF can be defined as the unique electrochemical signal or pattern, mostly recorded by voltammetric techniques, specific for a certain molecule that can be used for its quantitative or semi-quantitative identification in a given analytical context with specified circumstances. The performance of EF-based sensors can be enhanced by considering multiple features of the signal (i.e., oxidation or reduction patterns), in combination with statistical data analysis or sample pretreatments or by including electrode surface modifiers to enrich the EF. In this manuscript, some examples of EF-based sensors, strategies to improve their performances, and open challenges are discussed to unlock the full power of electrochemical fingerprinting for on-site sensing applications.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.3
Times cited: 3
DOI: 10.1007/S00216-020-02584-X
|
|
|
“Investigation of inclusions trapped inside Libyan desert glass by Raman microscopy”. Swaenen M, Stefaniak EA, Frost R, Worobiec A, Van Grieken R, Analytical and bioanalytical chemistry 397, 2659 (2010). http://doi.org/10.1007/S00216-009-3351-2
Abstract: Several specimens of Libyan desert glass (LDG), an enigmatic natural glass from Egypt, were subjected to investigation by micro-Raman spectroscopy. The spectra of inclusions inside the LDG samples were successfully measured through the layers of glass and the mineral species were identified on this basis. The presence of cristobalite as typical for high-temperature melt products was confirmed, together with co-existing quartz. TiO2 was determined in two polymorphic species rutile and anatase. Micro-Raman spectroscopy proved also the presence of minerals unusual for high-temperature glasses such as anhydrite and aragonite.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S00216-009-3351-2
|
|
|
“Particulate matter analysis at elementary schools in Curitiba, Brazil”. Avigo D, Godoi AFL, Janissek PR, Makarovska Y, Krata A, Potgieter-Vermaak S, Alfoldy B, Van Grieken R, Godoi RHM, Analytical and bioanalytical chemistry 391, 1459 (2008). http://doi.org/10.1007/S00216-008-2031-Y
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-008-2031-Y
|
|
|
“Possibilities of energy-resolved X-ray radiography for the investigation of paintings”. Cabal Rodríguez AE, Leyva Pernia D, Schalm O, van Espen PJM, Analytical and bioanalytical chemistry 402, 1471 (2012). http://doi.org/10.1007/S00216-011-5230-X
Abstract: X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-011-5230-X
|
|
|
“Unraveling the effect of the aptamer complementary element on the performance of duplexed aptamers : a thermodynamic study”. Dillen A, Vandezande W, Daems D, Lammertyn J, Analytical And Bioanalytical Chemistry 413, 4739 (2021). http://doi.org/10.1007/S00216-021-03444-Y
Abstract: Duplexed aptamers (DAs) are widespread aptasensor formats that simultaneously recognize and signal the concentration of target molecules. They are composed of an aptamer and aptamer complementary element (ACE) which consists of a short oligonucleotide that partially inhibits the aptamer sequence. Although the design principles to engineer DAs are straightforward, the tailored development of DAs for a particular target is currently based on trial and error due to limited knowledge of how the ACE sequence affects the final performance of DA biosensors. Therefore, we have established a thermodynamic model describing the influence of the ACE on the performance of DAs applied in equilibrium assays and demonstrated that this relationship can be described by the binding strength between the aptamer and ACE. To validate our theoretical findings, the model was applied to the 29-mer anti-thrombin aptamer as a case study, and an experimental relation between the aptamer-ACE binding strength and performance of DAs was established. The obtained results indicated that our proposed model could accurately describe the effect of the ACE sequence on the performance of the established DAs for thrombin detection, applied for equilibrium assays. Furthermore, to characterize the binding strength between the aptamer and ACEs evaluated in this work, a set of fitting equations was derived which enables thermodynamic characterization of DNA-based interactions through thermal denaturation experiments, thereby overcoming the limitations of current predictive software and chemical denaturation experiments. Altogether, this work encourages the development, characterization, and use of DAs in the field of biosensing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
DOI: 10.1007/S00216-021-03444-Y
|
|
|
“Can plasma spectrochemistry assist in improving the accuracy of chemical analysis?”.Adams F, Adriaens A, Bogaerts A, Analytica chimica acta 456, 63 (2002). http://doi.org/10.1016/S0003-2670(02)00010-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.95
Times cited: 6
DOI: 10.1016/S0003-2670(02)00010-7
|
|
|
“Determination of gold at the ultratrace level in natural waters”. Cidu R, Fanfani L, Shaud P, Edmunds WM, Van 't dack L, Gijbels R, Analytica chimica acta 296, 295 (1994). http://doi.org/10.1016/0003-2670(94)80249-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 20
DOI: 10.1016/0003-2670(94)80249-1
|
|
|
“Determination of precious metals in ores and rocks by thermal neutron activation/\gamma-spectrometry after preconcentration by nickel sulphide fire assay and coprecipitation with tellurium”. Shazali I, Van 't dack L, Gijbels R, Analytica chimica acta 196, 49 (1987). http://doi.org/10.1016/S0003-2670(00)83069-X
Abstract: The six platinum group elements (Ru, Rh, Pd, Os, Ir and Pt) can be determined in geological samples down to the μg kg−1 level, by using nickel sulphide fire assay and neutron activation of the residue ramaining after dissolution of the nickel sulphide button in concentrated hydrochloric acid. Losses for the platinum group elements during this dissolution step are usually insignificant, except when the elements are present at ultra-trace levels. The can be recovered from the filtrate by coprecipitation with tellerium. The latter approach also permits determination of silver, which is significantly lost in the hydrochloric acid treatment (recovery <98% instead of typically ≈ 10%). The coprecipitation with tellurium considerably improves the results for gold (recovery ≈ 95% instead of typically 75%).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 49
DOI: 10.1016/S0003-2670(00)83069-X
|
|
|
“Determination of silicon in natural and pollution aerosols by 14-MeV neutron activation analysis”. Gijbels R, Dams R, Analytica chimica acta 63, 369 (1973). http://doi.org/10.1016/S0003-2670(01)82362-X
Abstract: The determination of silicon via the 28Si(n,p)28 Al reaction by means of 14-MeV neutrons is applied to the analysis of pollution and natural aerosols. A Whatman 41 filter (40 cm2) on which airborne particulate material has been collected is compressed into a 3 × 12.7 mm pellet. Standards are prepared in the same way from clean filters spiked with a silicate solution. After a 50-s irradiation and a 75-s decay time, the sample is counted for 2 min with 5 × 5 NaI(Tl) well detector. The 1.779-MeV photopeak of 28Al is measured with a single channel sealer chain or with a multichannel analyser. The reproducibility, sensitivity and liability to interference from other elements were investigated for both counting systems. The homogeneity of the pellets and the filters was checked. The overall precision of one single-channel determination was estimated to be 3.5% after a 24-h high-volume sampling time. Samples collected in urban, industrial and remote areas with concentrations ranging from 0.05 to 15 μg Si m-3 air were analysed and the results are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 16
DOI: 10.1016/S0003-2670(01)82362-X
|
|
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
|
|
“Internal standard activation analysis of silicon in steel”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 381 (1968). http://doi.org/10.1016/S0003-2670(00)89235-1
Abstract: Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 14
DOI: 10.1016/S0003-2670(00)89235-1
|
|
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, van Grieken R, Gijbels R, Caravatti P, Analytica chimica acta 283, 139 (1993). http://doi.org/10.1016/0003-2670(93)85216-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 17
DOI: 10.1016/0003-2670(93)85216-7
|
|
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 64, 187 (1973). http://doi.org/10.1016/S0003-2670(01)82436-3
Abstract: A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 11
DOI: 10.1016/S0003-2670(01)82436-3
|
|
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 65, 1 (1973). http://doi.org/10.1016/S0003-2670(01)80158-6
Abstract: A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 12
DOI: 10.1016/S0003-2670(01)80158-6
|
|