“A Benzocaine‐Induced Local Near‐Surface pH Effect: Influence on the Accuracy of Voltammetric Cocaine Detection”. de Jong M, Sleegers N, Schram J, Daems D, Florea A, De Wael K, Analysis &, Sensing , anse.202000012 (2020). http://doi.org/10.1002/anse.202000012
Abstract: This work reports on a local induced near-surface pH effect (pHS), due to the presence of one analyte, leading to an influence or even suppression of redox signals of a second analyte present in solution. This concept and its impact on voltammetric sensing is illustrated by focusing on the detection of cocaine in the presence of the common adulterant benzocaine. An in-depth study on the occurring interference mechanism and why it occurs for benzocaine specifically and not for other adulterants was performed through the use of multiple electrochemical strategies. It was concluded that the potential shift and loss of intensity of the squarewave voltammetric cocaine signal in the presence of benzocaine was caused by a local pHS effect. A cathodic pretreatment strategy was developed to nonetheless allow accurate cocaine detection. The gathered insights are useful to explain unidentified phenomena involving compounds with properties similar to benzocaine in voltammetric electroanalysis.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/anse.202000012
|
“A message in the dust”. Jambers W, Van Grieken R, Analysis Europe , 25 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Electrochemical Analysis of Speedball-like Polydrug Samples”. de Jong M, Florea A, Daems D, Van Loon J, Samyn N, De Wael K, Analyst (2020). http://doi.org/10.1039/D0AN01097A
Abstract: Increasing global production, trafficking and consumption of drugs of abuse cause an emerging threat to people’s health and safety. Electrochemical approaches have proven to be useful for on-site analysis of drugs of abuse. However, few attention has been focused on the analysis of polydrug samples, despite these samples causing severe health concerns, certainly when stimulants and depressants are combined, as is the case for Speedball, a mixture of cocaine and heroin. In this work, we provide solutions for the selective detection of cocaine (stimulant) in polydrug samples adulterated with heroin and codeine (depressants). The presence of either one of these compounds in cocaine street samples leads to an overlap with the cocaine signal in square-wave voltammetry measurements at unmodified carbon screen-printed electrodes, leading to inconclusive screening results in the field. The provided solutions to this problem consist of two parallel approaches: (i) cathodic pretreatment of the carbon screen-printed electrode surface prior to measurement in both alkaline and neutral conditions; (ii) electropolymerization of orthophenylenediamine on graphene modified carbon screen-printed electrodes prior to measurement in neutral conditions. Both strategies allow simultaneous detection of cocaine and heroin in speedball samples as well as simultaneous detection of cocaine and codeine. Implementing these strategies in portable devices holds great potential for significantly improved accuracy of on-site cocaine screening in polydrug samples.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Product development
Impact Factor: 4.2
DOI: 10.1039/D0AN01097A
|
“Gold-sputtered microelectrodes with built-in gold reference and counter electrodes for electrochemical DNA detection”. Thiruvottriyur Shanmugam S, Trashin S, De Wael K, Analyst (2020). http://doi.org/10.1039/D0AN01387K
Abstract: Gold-sputtered microelectrodes with built-in gold reference and counter electrodes represent a promising platform for the development of disposable DNA sensors. Pretreating gold electrode surfaces and immobilization of DNA thereon is commonly employed in biosensing applications. However, with no scientific or practical guidelines to prepare a DNA sensor using these miniature gold-sputtered microelectrodes, cleaning and immobilization steps need to be systematically optimized and updated. In this work, we present efficient cleaning and modification of miniaturized gold-sputtered microelectrodes with thiolated DNA probes for DNA detection. Additional discussions on subtleties and nuances involved at each stage of pretreating and modifying gold-sputtered microelectrodes are included to present a robust, well-founded protocol. It was evident that the insights on cleaning polycrystalline gold disk electrodes with a benchmark electrode surface for DNA sensors, cannot be transferred to clean these miniature gold-sputtered microelectrodes. Therefore, a comparison between five different cleaning protocols was made to find the optimal one for gold-sputtered microelectrodes. Additionally, two principally different immobilization techniques for gold-sputtered microelectrode modification with thiolated ssDNA were compared i.e., immobilization through passive chemisorption and potential perturbation were compared in terms of thiol-specific attachment and thiol-unspecific adsorption through nitrogenous bases. The hybridization performance of these prepared electrodes was characterized by their sensitive complementary DNA capturing ability, detected by a standard alkaline phosphatase assay. Immobilization through passive chemisorption proved to be efficient in capturing the complementary target DNA with a detection limit of 0.14 nM and sensitivity of 9.38 A M−1 cm2. In general, this work presents a comprehensive understanding of cleaning, modification and performance of gold-sputtered microelectrodes with built-in gold reference and counter electrodes for both fundamental investigations and practical DNA sensing applications.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.2
DOI: 10.1039/D0AN01387K
|
“Native mass spectrometry for the design and selection of protein bioreceptors for perfluorinated compounds”. Daems E, Moro G, Berghmans H, Moretto LM, Dewilde S, Angelini A, Sobott F, De Wael K, Analyst 146, 2065 (2021). http://doi.org/10.1039/D0AN02005B
Abstract: Biosensing platforms are answering the increasing demand for analytical tools for environmental monitoring of small molecules, such as per- and polyfluoroalkyl substances (PFAS). By transferring toxicological findings in bioreceptor design we can develop innovative pathways for biosensor design. Indeed, toxicological studies provide fundamental information about PFAS-biomolecule complexes that can help evaluate the applicability of the latter as bioreceptors. The toolbox of native mass spectrometry (MS) can support this evaluation, as shown by the two case studies reported in this work. The analysis of model proteins’ (i.e. albumin, haemoglobin, cytochrome c and neuroglobin) interactions with well-known PFAS, such as perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS), demonstrated the potential of this native MS screening approach. In the first case study, untreated albumin and delipidated albumin were compared in the presence and absence of PFOA confirming that the delipidation step increases albumin affinity for PFOA without affecting protein stability. In the second case study, the applicability of our methodology to identify potential bioreceptors for PFOS/PFOA was extended to other proteins. Structurally related haemoglobin and neuroglobin revealed a 1 : 1 complex, whereas no binding was observed for cytochrome c. These studies have value as a proof-of-concept for a general application of native MS to identify bioreceptors for toxic compounds.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.885
DOI: 10.1039/D0AN02005B
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
“Internal standard activation analysis of silicon in steel”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 381 (1968). http://doi.org/10.1016/S0003-2670(00)89235-1
Abstract: Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 14
DOI: 10.1016/S0003-2670(00)89235-1
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, van Grieken R, Gijbels R, Caravatti P, Analytica chimica acta 283, 139 (1993). http://doi.org/10.1016/0003-2670(93)85216-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 17
DOI: 10.1016/0003-2670(93)85216-7
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 64, 187 (1973). http://doi.org/10.1016/S0003-2670(01)82436-3
Abstract: A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 11
DOI: 10.1016/S0003-2670(01)82436-3
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 65, 1 (1973). http://doi.org/10.1016/S0003-2670(01)80158-6
Abstract: A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 12
DOI: 10.1016/S0003-2670(01)80158-6
|
“Evaluation of energy-dispersive x-ray-spectra with the aid of expert systems”. Janssens K, van Espen P, Analytica chimica acta 191, 169 (1986). http://doi.org/10.1016/S0003-2670(00)86306-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86306-0
|
“Implementation of an expert system for the qualitative interpretation of x-ray-fluorescence spectra”. Janssens K, van Espen P, Analytica chimica acta 184, 117 (1986). http://doi.org/10.1016/S0003-2670(00)86475-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86475-2
|
“Microanalytical characterization of surface decoration in Majolica pottery”. Padilla R, Schalm O, Janssens K, Arrazcaeta R, van Espen P, Analytica chimica acta 535, 201 (2005). http://doi.org/10.1016/J.ACA.2004.11.082
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 4.95
Times cited: 20
DOI: 10.1016/J.ACA.2004.11.082
|
“Surface microanalysis”. Adams F, Adriaens A, Berghmans P, Janssens K, Analytica chimica acta 283, 19 (1993). http://doi.org/10.1016/0003-2670(93)85207-Z
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(93)85207-Z
|
“Synchrotron radiation-induced X-ray microanalysis”. Janssens K, Vincze L, Adams F, Jones KW, Analytica chimica acta 283, 98 (1993). http://doi.org/10.1016/0003-2670(93)85213-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(93)85213-4
|
“Analysis of rain water by differential-pulse stripping voltammetry in nitric acid medium”. Komy Z, Roekens E, Van Grieken R, Analytica chimica acta 204, 179 (1988). http://doi.org/10.1016/S0003-2670(00)86357-6
Abstract: Differential-pulse anodic stripping voltammetry is applied to determine cadmium, lead and copper in rain water acidified with nitric acid to pH 1.5, and zinc after partial neutralization to pH 4.5. Subsequently, cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The effects of pH on the stripping peaks for Zn, Cd, Pb and Cu and of chloride on the stripping peak of copper are reported. Good agreement is found with d.p.s.v. determinations in hydrochloric acid medium and with a.a.s. measurements in most cases. Excellent accuracy is demonstrated; the average relative standard deviation per measurement appears to be between 12 and 22% for the overall analytical procedure for concentrations of 0.1550 μgl−1 of the various metals in the samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)86357-6
|
“Application of chemometric methods for classification of atmospheric particles based on thin-window electron probe microanalysis data”. Osán J, de Hoog J, Worobiec A, Ro C-U, Oh K-Y, Szalóki I, Van Grieken R, Analytica chimica acta 446, 211 (2001)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Assessment of homogeneity of candidate reference material at the nanogram level and investigation on representativeness of single particle analysis using electron probe X-ray microanalysis”. Ro C-U, Hoornaert S, Van Grieken R, Analytica chimica acta 389, 151 (1999). http://doi.org/10.1016/S0003-2670(99)00160-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(99)00160-9
|
“Automated evaluation of photographically recorded spark-source mass spectra”. Vanderborght B, Van Grieken R, Analytica chimica acta 103, 223 (1978). http://doi.org/10.1016/S0003-2670(01)84041-1
Abstract: A computer routine was developed for qualitative and quantitative analysis of photographically recorded spark-source mass spectra. Particular attention is given to the case of a graphite matrix. The program starts from the line intensities (expressed as Seidel values) and isotope masses calculated from the densitometer readings by a commercially available routine. From the intensities in the different exposures (typically 15 stages), it computes the parameters for the linear parts of the density curves for each ion. Taking into account mutual interferences of multivalent ions, isotope or C-clusters, oxide, carbide and dicarbide ions, the program automatically identifies and then quantifies the elements present. The precision of the results is around 5%. Reading and complete processing of one photoplate is achieved within 23 h.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84041-1
|
“CAC-2010 : Twelfth international conference on chemometrics in analytical chemistry”. Buydens L, van Espen P, Rutan S, Analytica chimica acta 705, 1 (2011). http://doi.org/10.1016/J.ACA.2011.08.001
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ACA.2011.08.001
|
“Comparison and evaluation of hierarchical cluster techniques applied to automated electron probe X-ray microanalysis data”. Bernard PC, Van Grieken RE, Analytica chimica acta 267, 81 (1992). http://doi.org/10.1016/0003-2670(92)85009-U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(92)85009-U
|
“Comparison of preconcentration procedures for trace metals in natural waters”. Smits J, Nelissen J, Van Grieken R, Analytica chimica acta 111, 215 (1979). http://doi.org/10.1016/S0003-2670(01)93264-7
Abstract: The relative merits of eight procedures for preconcentrations of trace metal ions from natural water samples and synthetic solutions are evaluated. Spikes (100 μg l−1 ) of Mn, Co, Zn, Eu, Cs and Ba and the corresponding radioactive tracers were added to batches of drinking water, estuarine water, sea water, ground water, twice-distilled water and ahumic material solution. After equilibration for 25 months, the following techniques were applied: passage through columns of Dowex Al chelating resin and ofsilylated silica gel, filtration through laminate membrane filters and chelating diethylenetriamine cellulose filters, precipitation with sodium diethyldithiocarbamate and l-(2-pyridylazo)-2-naphthol, extraction with ammonium pyrrolidinedithiocarbamate, and chelation by 8-quinolinol (oxine) followed by adsorption on activated carbon. The quantitative characteristics of these techniques and the influence of the water matrix effects are discussed, as well as the applicability for x-ray fluorescence analysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93264-7
|
“Controlling the mixed potential of polyelectrolyte-coated platinum electrodes for the potentiometric detection of hydrogen peroxide”. Baez JF, Compton M, Chahrati S, Cánovas R, Blondeau P, Andrade FJ, Analytica Chimica Acta 1097, 204 (2020). http://doi.org/10.1016/J.ACA.2019.11.018
Abstract: The use of a Pt electrode coated with a layer of Nafion has been described in previous works as an attractive way to perform the potentiometric detection of hydrogen peroxide. Despite of the attractive features of this approach, the nature of the non-Nernstian response of this system was not properly addressed. In this work, using a mixed potential model, the open circuit potential of the Pt electrode is shown to be under kinetic control of the oxygen reduction reaction (ORR). It is proposed that hydrogen peroxide acts as an oxygenated species that blocks free sites on the Pt surface, interfering with the ORR. Therefore, the effect of the polyelectrolyte coating can be understood in terms of the modulation of the factors that affects the kinetics of the ORR, such as an increase of the H+ concentration, minimization of the effect of the spectator species, etc. Because of the complexity and the lack of models that accurately describe systems with practical applications, this work is not intended to provide a mechanistic but rather a phenomenological view on problem. A general framework to understand the factors that affect the potentiometric response is provided. Experimental evidence showing that the use of polyelectrolyte coatings are a powerful way to control the mixed potential open new ways for the development of robust and simple potentiometric sensors.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.2
DOI: 10.1016/J.ACA.2019.11.018
|
“Coprecipitation with aluminium hydroxide and x-ray fluorescence determination of trace metals in water”. Eltayeb MAH, Van Grieken RE, Analytica chimica acta 268, 177 (1992). http://doi.org/10.1016/0003-2670(92)85262-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(92)85262-5
|
“The determination of copper in iron and steel by 14-Mev neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 51, 151 (1970). http://doi.org/10.1016/S0003-2670(01)95703-4
Abstract: A fast (10 min) non-destructive determination of copper in. steel and cast iron by 14-MeV neutron activation analysis is described. The 0.511-MeV annihilation radiation of62Cu (T1/2=9.8 min), induced by the reaction63Cu(n,2n)62Cu, is counted by two opposing NaI(Tl) detectors operating in coincidence. An oxygen flux monitor is used to normalise the irradiations. For high phosphorus contents, two measurements are made and the 9-min activity contribution is calculated. As the iron content of the samples is known, the use of pure iron samples allows correction for53Fe activity from the reaction54Fe(n,2n)53Fe(T1/2= 8.9 min). When the phosphorus and silicon activities are low, the procedure of counting and computing can be greatly simplified. Nuclear interferences of most common alloying and impurity elements were investigated.The precision is 23% for steels containing above 1% Cu, andCa. 10% for 0.1%Cu.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95703-4
|
“Determination of rare earth elements in geological materials by total reflection X-ray fluorescence”. Muia LM, Van Grieken R, Analytica chimica acta 251, 177 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Determination of trace elements in organic matrices by grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken R, Analytica chimica acta 401, 293 (1999). http://doi.org/10.1016/S0003-2670(99)00471-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(99)00471-7
|
“Determination of trace metals in rain water by differential-pulse stripping voltammetry”. Vos L, Komy G, Reggers G, Roekens E, Van Grieken R, Analytica chimica acta 184, 271 (1986). http://doi.org/10.1016/S0003-2670(00)86491-0
Abstract: Differential-pulse stripping voltammetry is applied to measure zinc, cadmium, lead and copper by anodic stripping and selenium(IV) by cathodic stripping in rain water at pH 2; subsequently, at pH 9,1, manganese is measured by anodic stripping on the same portion, and cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The instrumental parameters are optimized. The linear ranges, mutual interferences and detection limits are studied. Excellent accuracy is demonstrated; the standard deviation is around 15% at 2.550 μg l−1 levels. The method is shown to be applicable for rain water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)86491-0
|
“Determination of trace selenium in biological material by preconcentration and X-ray emission spectrometry”. Robberecht H, Van Grieken R, Analytica chimica acta 147, 113 (1983). http://doi.org/10.1016/0003-2670(83)80077-4
Abstract: Selenium is determined in the ng g−1 to μg g−1 range in biological and environmental samples. A wet digestion procedure was optimized with respect to volatility losses and recovery yields, by using 75Se metabolically incorporated into rat organs. Selenium is preconcentrated from the digestion liquid by a two-step reduction with 4 M HCl and ascorbic acid. The colloidal selenium formed is adsorbed on activated carbon and filtered on a Nucleopore membrane for measurement by energy-dispersive x-ray fluorescence. Almost complete recovery was obtained, and the detection limit was 20 ng, corresponding to 10 ng g−1 for a 2-g sample. Biological reference materials were analyzed with satisfactory results, and the accuracy of the method was good.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(83)80077-4
|
“Elucidating the composition of atmospheric aerosols through the combined hierarchical, non-hierarchical and fuzzy clustering of large electron probe microanalysis data sets”. Treiger B, Bondarenko I, van Malderen H, Van Grieken R, Analytica chimica acta 317, 33 (1995). http://doi.org/10.1016/0003-2670(95)00405-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(95)00405-X
|