“ID18F: a new X-ray microprobe end station”. Somogyi A, Drakopoulos M, Vincze L, Vekemans B, Camerani C, Janssens K, Snigirev A, Adams F, ESRF highlights 2001 , 96 (2002)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Williams CT, Radtke M, Haller M, Knöchel A, Fresenius' journal of analytical chemistry 363, 413 (1999). http://doi.org/10.1007/S002160051212
Abstract: The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051212
|
|
|
“The preparation and preliminary characterisation of eight geological MPI-DING reference glasses for in-site microanalysis”. Jochum KP, Dingwell DB, Rocholl A, Janssens K, Vincze L, et al, Geostandards newsletter 24, 87 (2000). http://doi.org/10.1111/J.1751-908X.2000.TB00590.X
Abstract: Eight silicate glasses were prepared by directly fusing and stirring 50-100 g each of basalt, andesite, komatiite, peridotite, rhyolite, and quartz-diorite. These are referred to as MPI-DING glasses and were made for the purpose of providing reference materials for geochemical, in-situ microanalytical work. Results from various analytical techniques indicate that individual glass fragments are well homogenised with respect to major and trace elements at the mu m to mm scale. Heterogeneities due to quench crystallisation of olivine have been observed in small and limited areas of the two komatiitic glasses. In order to obtain concentration values for as many elements as possible, the glasses were analysed by a variety of bulk and microanalytical methods in a number of laboratories. From the analytical data, preliminary reference values for more than sixty elements were calculated. The analytical uncertainties of most elements are estimated to be between 1% and 10%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1751-908X.2000.TB00590.X
|
|
|
“Fluorescent tomography of phantom samples at the beamline L”. Vekemans B, Vincze L, Vittiglio G, Janssens K, Adams F, HASYLAB Jahresbericht (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Provenance analysis of Roman glass from the 1st-6th century A.D”. Aerts A, Janssens K, Vincze L, Vekemans B, Adams F, Haller M, Radtke M, Knöchel A, HASYLAB Jahresbericht , 918 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Quantification of SY-XRF measurements at the X-ray microprobe”. Haller M, Radtke M, Knöchel A, Clöck W, Sutton S, Janssens K, Vincze L, HASYLAB Jahresbericht , 956 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Composition of 15-17th century archaeological glass vessels excavated in Antwerp, Belgium”. Janssens K, de Raedt I, Vincze L, Vekemans B, Adams F, Haller M, Knöchel A, HASYLAB Jahresbericht 1997 1, 937 (1998)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Evaluation of a Monte Carlo simulation for EDXRF spectrometers at beamline BW5, HASYLAB”. Vincze L, Vekemans B, Janssens K, Adams F, Lippmann T, HASYLAB Jahresbericht 1997 1, 1043 (1998)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Fluorescent tomography of metals in fly-ash particles at beamline L”. Vincze L, Vekemans B, Janssens K, Adams F, Haller M, HASYLAB Jahresbericht 1997 1, 959 (1998)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray optics for synchrotron-radiation-induced X-ray micro fluorescence at the european synchrotron-radiation facility, Grenoble”. Vincze L, Janssens K, Adams F, Institute of physics conference series , 613 (1993)
Abstract: Different optical designs for generating synchrotron x-ray micro beams suitable for use in an X-ray fluorescence microscope using an ESRF bending magnet X-ray source are compared. Attention is devoted to the spatial and energy distribution of the photons in the micro beam and to the minimum detection limits that are achievable with each alternative optical system.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Modeling of photon scattering at high X-ray energies : experiment versus simulation”. Vincze L, Vekemans B, Janssens K, Adams F, Journal of analytical atomic spectrometry
T2 –, 15th International Congress on X-Ray Optics and Microanalysis (ICXOM), AUG 24-27, 1998, ANTWERP, BELGIUM 14, 529 (1999). http://doi.org/10.1039/A808040B
Abstract: The use of a detailed Monte Carlo simulation code for X-ray fluorescence spectrometers is demonstrated for calculating the outcome of X-ray scattering experiments in the incident energy range 40-80 keV. The code was validated by comparisons of experimental and simulated spectral distributions in the case of thick, homogeneous samples in which multiple photon scattering occurs with high probability. The experimental spectral distributions were collected at beamline BW5 of HASYLAB, Germany, where a highly energetic, monochromatic synchrotron beam is available. With respect to heterogeneous samples, the code was employed to evaluate the use of Rayleigh and Compton scatter signals for obtaining three dimensional information on the sample dark matrix composition.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A808040B
|
|
|
“Micro-heterogeneity study of trace elements in USGS, MPI-DING and glass reference materials by means of synchrotron micro-XRF”. Kempenaers L, Janssens K, Jochum KP, Vincze L, Vekemans B, Somogyi A, Drakopoulos M, Adams F, Journal of analytical atomic spectrometry 18, 350 (2003). http://doi.org/10.1039/B212196D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 38
DOI: 10.1039/B212196D
|
|
|
“Microscopic X-ray fluorescence analysis”. Janssens K, Vincze L, Rubio J, Bernasconi G, Adams F, Journal of analytical atomic spectrometry 9, 151 (1994). http://doi.org/10.1039/JA9940900151
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/JA9940900151
|
|
|
“Suitability of polycapillary optics for focusing of monochromatic synchrotron radiation as used in trace level micro-XANES measurements”. Vincze L, Wei F, Proost K, Vekemans B, Janssens K, He Y, Yan Y, Falkenberg G, Journal of analytical atomic spectrometry 17, 177 (2002). http://doi.org/10.1039/B110210A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/B110210A
|
|
|
“Trace analysis allows to distinguish between Venetian and facon-de-Venise glass vessels of the 16th and 17th century”. de Raedt I, Janssens K, Veeckman J, Vincze L, Vekemans B, Jeffries T, Journal of analytical atomic spectrometry 16, 1012 (2001). http://doi.org/10.1039/B102597J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 49
DOI: 10.1039/B102597J
|
|
|
“The use of lead-glass capillaries for microfocusing of highly energetic (0-60 KeV) synchrotron radiation”. Janssens K, Vincze L, Vekemans B, Adams F, Haller M, Knöchel A, Journal of analytical atomic spectrometry 13, 339 (1998). http://doi.org/10.1039/A707700I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A707700I
|
|
|
“Processing of three-dimensional microscopic X-ray fluorescence data”. Vekemans B, Vincze L, Brenker FE, Adams F, Journal of analytical atomic spectrometry 19, 1302 (2004). http://doi.org/10.1039/B404300F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B404300F
|
|
|
“Reclaiming the image of daguerreotypes: Characterization of the corroded surface before and after atmospheric plasma treatment”. Grieten E, Schalm O, Tack P, Bauters S, Storme P, Gauquelin N, Caen J, Patelli A, Vincze L, Schryvers D, Journal of cultural heritage (2017). http://doi.org/10.1016/j.culher.2017.05.008
Abstract: Technological developments such as atmospheric plasma jets for industry can be adapted for the conservation of cultural heritage. This application might offer a potential method for the removal or transformation of the corrosion on historical photographs. We focus on daguerreotypes and present an in-depth study of the induced changes by a multi-analytical approach using optical microscopy, scanning electron microscopy, different types of transmission electron microscopy and X-ray absorption fine structure. The H2-He afterglow removes S from an Ag2S or Cu2S layer which results in a nano-layer of metallic Ag or Cu on top of the deteriorated microstructure. In case the corrosion layer is composed of Cu-Ag-S compounds, our proposed setup can be used to partially remove the corrosion. These alterations of the corrosion results in an improvement in the readability of the photographic image.
Keywords: A1 Journal article; Art; History; Electron microscopy for materials research (EMAT); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 1.838
Times cited: 9
DOI: 10.1016/j.culher.2017.05.008
|
|
|
“Parameters influencing focussing capabilities of capillary optics”. Vincze L, Janssens K, Adams F, Larsson S, Rindby A, Engstrom P, Microbeam Analysis 1995: Proceedings Of The 29th Annual Conference Of The Microbeam Analysis Society , 161 (1995)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Quantitative mu-XRF analysis of heterogeneous samples”. Vincze L, Janssens K, Adams F, Jones K, Microbeam Analysis 1995: Proceedings Of The 29th Annual Conference Of The Microbeam Analysis Society , 175 (1995)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Synchrotron radiation induced X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Aerts A, Adams F, Jones KW, Knöchel A, Microchimica acta
T2 –, 4th Workshop of the European-Microanalysis-Society on Modern, Developments and Applications in Microbeam Analysis, MAY, 1995, ST MALO, FRANCE , 87 (1996)
Abstract: mu-XRF is the microscopic equivalent of the well-established multielement analytical technique. In this paper, after comparing the interaction of X-ray photons, electrons and protons with matter and an introduction to synchrotron rings and microfocussing of X-rays, the instrumentation for mu-XRF is discussed, both for laboratory source and synchrotron based setups and the analytical characteristics of mu-XRF are contrasted to that of other microanalytical techniques, Also, this issue of quantification of mu-XRF data is addressed; the applicability of the method in archeological and geological analysis is illustrated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“PXRF, \mu-XRF, vacuum \mu-XRF, and EPMA analysis of Email Champlevé, objects present in Belgian museums”. van der Linden V, Meesdom E, Devos A, van Dooren R, Nieuwdorp H, Janssen E, Balace S, Vekemans B, Vincze L, Janssens K, Microscopy and microanalysis 17, 674 (2011). http://doi.org/10.1017/S1431927611011950
Abstract: The enamel of 20 Email Champlevé objects dating between the 12th and 19th centuries was investigated by means of microscopic and portable X-ray fluorescence analysis (μ-XRF and PXRF). Seven of these objects were microsampled and the fragments were analyzed with electron probe microanalysis (EPMA) and vacuum μ-XRF to obtain quantitative data about the composition of the glass used to produce these enameled objects. As a result of the evolution of the raw materials employed to produce the base glass, three different compositional groups could be discriminated. The first group consisted of soda-lime-silica glass with a sodium source of mineral origin (with low K content) that was opacified by addition of calcium antimonate crystals. This type of glass was only used in objects made in the 12th century. Email Champlevé objects from the beginning of the 13th century onward were enameled with soda-lime-silica glass with a sodium source of vegetal origin. This type of glass, which has a higher potassium content, was opacified with SnO2 crystals. The glass used for 19th century Email Champlevé artifacts was produced with synthetic and purified components resulting in a different chemical composition compared to the other groups. Although the four analytical techniques employed in this study have their own specific characteristics, they were all found to be suitable for classifying the objects into the different chronological categories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.891
Times cited: 9
DOI: 10.1017/S1431927611011950
|
|
|
“Microscopic synchroton radiation induced X-ray fluorescence analysis”. Janssens K, Vincze L, Aerts A, Vekemans B, Adams F, Jones K, Knöchel A, Mikrochimica acta: supplementum , 87 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“3D extension of the Monte Carlo code MCSHAPE for photon-matter interactions in the heterogeneous media”. Scot V, Fernandez JE, Vincze L, Janssens K, Nuclear instruments &, methods in physics research section B-Beam interactions with materiala and atoms 263, 204 (2007). http://doi.org/10.1016/J.NIMB.2007.04.205
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 15
DOI: 10.1016/J.NIMB.2007.04.205
|
|
|
“A compact μ-XRF spectrometer for (in-situ) analyses of cultural heritage and forensic materials”. Vittiglio G, Bichlmeier S, Klinger P, Heckel J, Fuzhong W, Vincze L, Janssens K, Engström P, Rindby A, Dietrich K, Jembrih-Simbürger D, Schreiner M, Denis D, Lakdar A, Lamotte A, Nuclear instruments and methods in physics research B 213, 693 (2004)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Characterization of impact materials around Barringer meteor crater by micro-PIXE nd micro-SRXRF techniques”. Uzonyi I, Szöör G, Rozsa P, Vekemans B, Vincze L, Adams F, Drakopoulos M, Somogyi A, Kiss ÁZ, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 219/220, 555 (2004). http://doi.org/10.1016/J.NIMB.2004.01.119
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2004.01.119
|
|
|
“Effects of beamline components (undulators, monochromator, focusing devices) on the beam intensity at ID18F (ESRF)”. Somogyi A, Drakopoulos M, Vekemans B, Vincze L, Simionovici AS, Adams F, Nuclear instruments and methods: B 199, 559 (2003). http://doi.org/10.1016/S0168-583X(02)01535-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0168-583X(02)01535-5
|
|
|
“Quantitative X-ray fluorescence analysis at the ESRF ID18F microprobe”. Vekemans B, Vincze L, Somogyi A, Drakopoulos M, Kempenaers L, Simionovici AS, Adams F, Nuclear instruments and methods: B 199, 396 (2003). http://doi.org/10.1016/S0168-583X(02)01396-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0168-583X(02)01396-4
|
|
|
“Simulation of poly-capillary lenses for coherent and partially coherent x-rays”. Vincze L, Kukhlevsky SV, Janssens K, Proceedings of the Society of Photo-optical Instrumentation Engineers
T2 –, Conference on Advances in Computational Methods for X-Ray and Neutron, Optics, AUG 03-05, 2004, Denver, CO , 81 (2004). http://doi.org/10.1117/12.560740
Abstract: The intensity distributions of the coherent and partially coherent x-rays passed through a poly-capillary lens have been computed at the focal plane. The computations showed that at the appropriate experimental conditions the interference phenomenon does affect the intensity distribution. In the case of the coherent input radiation with the photon energy of 0.1 keV, the interference fringes were observed, while the non-coherent x-ray radiation produced no interference-like intensity distributions.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 6
DOI: 10.1117/12.560740
|
|
|
“A general Monte-Carlo simulation of energy-dispersive X-ray fluorescence spectrometers : 1 : unpolarized radiation, homogenious samples”. Vincze L, Janssens K, Adams F, Spectrochimica acta: part B : atomic spectroscopy 48, 553 (1993). http://doi.org/10.1016/0584-8547(93)80060-8
Abstract: A general Monte Carlo program for the simulation of X-ray fluorescence (XRF) spectrometers is presented. The global layout of the program is discussed and the way in which variance reduction techniques have been employed to improve the efficiency of the code is described. For the case of polychromatic excitation in a direct excitation energy-dispersive (ED) XRF instrument, experimentally collected ED-XRF spectra are compared with simulated spectral distributions. Applications of the software in the field of quantitative analysis and thickness estimation of samples of intermediate thickness illustrate the potential of the method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0584-8547(93)80060-8
|
|