|
“Metallic nanoparticles on plasma treated carbon nanotubes : $Nano2hybrids$”. Bittencourt C, Felten A, Douhard B, Colomer J-F, Van Tendeloo G, Drube W, Ghijsen J, Pireaux J-J, Surface science : a journal devoted to the physics and chemistry of interfaces
T2 –, International Conference on NANO-Structures Self Assembling, JUL 02-06, 2006, Aix en Provence, FRANCE 601, 2800 (2007). http://doi.org/10.1016/j.susc.2006.12.045
Abstract: Multi-wall carbon nanotubes (MWCNTs) were decorated with metal clusters by thermal evaporation. Transmission electron microscopy (TEM) shows that the nature and extent of metal coverage can be varied by plasma treating the MWCNT surface. The metal clusters on oxygen plasma treated arc-discharge MWCNTs have a more dense distribution than the clusters evaporated on as-synthesized are-discharge MWCNTs. In contrast, the plasma treatment did not affect the cluster distribution on CVD MWCNTs. Analyses of the valence band and the core levels by X-ray photoelectron spectroscopy suggest poor charge transfer between gold clusters and MWCNTs; on the contrary suggest good charge transfer between Ni clusters and MWCNTs. (c) 2007 Elsevier B. V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.062
Times cited: 44
DOI: 10.1016/j.susc.2006.12.045
|
|
|
“Atomic oxygen functionalization of vertically aligned carbon nanotubes”. Bittencourt C, Navio C, Nicolay A, Ruelle B, Godfroid T, Snyders R, Colomer J-F, Lagos MJ, Ke X, Van Tendeloo G, Suarez-Martinez I, Ewels CP, The journal of physical chemistry: C : nanomaterials and interfaces 115, 20412 (2011). http://doi.org/10.1021/jp2057699
Abstract: Vertically aligned multiwalled carbon nanotubes (v-MWCNTs) are functionalized using atomic oxygen generated in a microwave plasma. X-ray photoelectron spectroscopy depth profile analysis shows that the plasma treatment effectively grafts oxygen exclusively at the v-MWCNT tips. Electron microscopy shows that neither the vertical alignment nor the structure of v-MWCNTs were affected by the plasma treatment. Density functional calculations suggest assignment of XPS C 1s peaks at 286.6 and 287.5 eV, to epoxy and carbonyl functional groups, respectively.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 4.536
Times cited: 31
DOI: 10.1021/jp2057699
|
|
|
“Ultrasonication induces oxygenated species and defects onto exfoliated graphene”. Skaltsas T, Ke X, Bittencourt C, Tagmatarchis N, The journal of physical chemistry: C : nanomaterials and interfaces 117, 23272 (2013). http://doi.org/10.1021/jp4057048
Abstract: The effect of ultrasonication parameters, such as time and power applied, to exfoliate graphite in o-dichlorobenzene (o-DCB) and N-methyl-1,2-pyrrolidone (NMP) was examined. It was found that the concentration of graphene was higher in o-DCB, while its dispersibility was increased when sonication was applied for a longer period and/or at higher power. However, spectroscopic examination by X-ray photoelectron spectroscopy (XPS) revealed that ultrasonication causes defects and induces oxygen functional groups in the form of carboxylic acids and ethers/epoxides onto the graphene lattice. Additional proof for the latter arose from Raman, IR, and thermogravimetry studies. The carboxylic acids and ethers/epoxides onto exfoliated graphene were derived from air during ultrasonication and found independent of the solvent used for the exfoliation and the power and/or time ultrasonication applied. Quantitative evaluation of the amount of oxygenated species present on exfoliated graphene as performed by high-resolution XPS revealed that the relative oxygen percentage was higher when exfoliation was performed in NMP. Finally, the sonication time and/or power affected the oxygen content on exfoliated graphene, since extended ultrasonication resulted in a decrease in the oxygen content on exfoliated graphene, with a simultaneous increase of defected sp(3) carbon atoms.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 4.536
Times cited: 65
DOI: 10.1021/jp4057048
|
|
|
“Metal-decorated multi-wall carbon nanotubes for low temperature gas sensing”. Espinosa EH, Lonescu R, Bittencourt C, Felten A, Erni R, Van Tendeloo G, Pireaux J-J, Llobet E, Thin solid films : an international journal on the science and technology of thin and thick films 515, 8322 (2007). http://doi.org/10.1016/j.tsf.2007.03.017
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.879
Times cited: 86
DOI: 10.1016/j.tsf.2007.03.017
|
|